Product Information
Technical Specifications
- Model: P6SD Series
- SEER: 13
- Phase: Three Phase
- Capacity: 3-5 Ton Units
- Refrigerant: R-410A
Features and Benefits
- High-efficiency self-contained cooling units
- Can be installed on a roof or on a slab
- Convertible unit design for easy installation
- ETL and ETLc listed
- Designed with the contractor and end user in mind
Warranty
The warranty information is not provided in the text extract.
Model Identification Code
- Application: Air Conditioning Packaged Unit
- Electrical Code: C = 208/230-60-3, D = 460-60-3
- Series: Square Duct
- D: 13 SEER Nominal Capacity x 1000 Btu
- R410A TXV
Dimensions
Top View
- A: 27.5 inches
- B: 26.5 inches
- C: 39.0 inches (with base rails)
Side View
- B: 13.5 inches
- C: 16 inches
- D: 47.5 inches
Back (Duct) View
- B: 13.5 inches
- C: 16 inches
- D: 11.75 inches
Specifications
P6SD Models – 208/230V Three Phase
- Model Number: P6SD-X36C
- Performance Capacity – Cooling BTUH: 34,200
- Efficiency – SEER: 13.30
- EER (Btuh/watt): 11.2
- Electrical Rating – 60Hz Phase: 3
- Operating Voltage Range: 187-253 Volts
- Compressor Data: Rated Load Amps – 11.6, Lock Rotor Amps – 73
- Indoor Blower Type: DD / 3 1/4 – 1075
- Motor – HP / RPM: 1/4 – 1100
- Motor – Amps: 1.2
- Outdoor Fan Motor – HP / RPM: 1/4 – 1100
- Outdoor Fan Motor – Amps: 1.2
- Fan Diameter / CFM: 20/3600
- Refrigerant Charge – Oz.: R-410A
- Net Weight: 110 lbs.
- Shipping Weight: 405 lbs.
- Filters (Field Installed): Disposable – Size (Qty): 16 x 25 x 1 (2)
P6SD Models – 460V Three Phase
- Model Number: P6SD-X36D
- Performance Capacity – Cooling BTUH: 34,200
- Efficiency – SEER: 13.30
- EER (Btuh/watt): 11.2
- Electrical Rating – 60Hz Phase: 3
- Operating Voltage Range: 414-506 Volts
- Compressor Data: Rated Load Amps – 6.4, Lock Rotor Amps – 38
- I ndoor Blower Type : DD / 3 1/4 – 1075
- Motor – HP / RPM: 1/4 – 1100
- Motor – Amps: 0.6
- Outdoor Fan Motor – HP / RPM: 1/4 – 1100
- Outdoor Fan Motor – Amps: 0.6
- Fan Diameter / CFM: 20/3600
- Refrigerant Charge – Oz.: R-410A
- Net Weight: 110 lbs.
- Shipping Weight: 405 lbs.
- Filters (Field Installed): Disposable – Size (Qty): 16 x 25 x 1 (2)
Product Usage Instructions
Installation
The P6SD Series packaged units can be installed on a roof or on a slab. The
convertible unit design makes installations simple in all applications.
- Choose a suitable location for the unit installation.
- Ensure that the installation location has proper ventilation and clearances as specified in the user manual.
- Follow the provided installation instructions for connecting electrical wiring.
- Connect the refrigerant lines as per the instructions.
- Install the unit securely using the appropriate mounting brackets or supports.
Operation
- Make sure the unit is connected to a suitable power source and the power supply is turned on.
- Set the desired temperature on the thermostat or control panel.
- The unit will start cooling and maintain the set temperature.
- Regularly clean and replace the air filters as per the maintenance instructions to ensure optimal performance.
Maintenance
Regular maintenance is essential to keep the unit functioning properly:
- Clean or replace the air filters regularly to prevent dust and debris buildup.
- Check and clean the condensing coil to ensure efficient heat transfer.
- Inspect and lubricate the fan motor as per the maintenance schedule.
- Keep the surrounding area of the unit clean and free from obstructions.
Frequently Asked Questions (FAQ)
-
Q: What is the warranty for the P6SD Series packaged units?
A: The warranty information is not provided in the text extract. Please refer to the product manual or contact the manufacturer for warranty details. -
Q: Can the P6SD Series units be installed indoors?
A: No, the P6SD Series units are designed for outdoor installation on a roof or a slab. -
Q: How often should I clean or replace the air filters?
A: It is recommended to clean or replace the air filters every 1-3 months, depending on usage and air quality.
The P6SD Series packaged units are high-efficiency self-contained cooling units that can be installed on a roof or a slab. The convertible unit design makes installations simple in all applications. Units are ETL and ETL listed. The unit is truly designed with the contractor and the end user in mind.
WARRANTY
- One-Year Commercial Parts Warranty
- 5-year limited Compressor Warranty
FEATURES and BENEFITS
- State-of-the-art Copeland Scroll compressor is standard equipment.
- R-410A Refrigerant Earth Friendly non-ozone depleting refrigerant.
- Proven, Industry Standard Components Easier service and availability.
- TXV Externally equalized. Provides precise refrigerant control under varying load conditions.
- High-Pressure Switch Protects against abnormally high system pressures.
- Liquid Line Filter/Drier Ensures clean and dry refrigeration system.
- Externally Accessible Service Ports Quick access to the refrigerant system without disrupting operation.
- Compact Footprint Easy to handle and transport.
- Convertible Air Delivery Horizontal or downflow to accommodate rooftop or horizontal application.
- Heavy-gauge, Full Perimeter Base Rails Facilitate forklift handling and curb mounting.
- A Galvanized Steel Cabinet with a polyurethane finish provides 950-hour salt spray protection.
- Plastic Mesh Hail Guard will never rust and protect the coil from being damaged by balls, lawnmowers, hail etc.
- Corrosion-Resistant Drain Pan Quickly drains away evaporator condensate.
- Quiet Operation Low Vibration. 20″ fan blade combined with custom venturi condenser fan opening.
- Access to Controls and Major Components Easy in and out service.
- Service Access Panels To all major components and the compressor. Designed to make servicing easier for the Contractor.
- Factory Installed Filter Rack 1″ or 2″ Capable.
- Easy to Install Electric heat strip provides 9 or 15 KW of heat output.
- Accessories Roof curbs, economizers, fresh air dampers and more.
MODEL IDENTIFICATION CODE
DIMENSIONS
SPECIFICATIONS
P6SD Models – 208/230V Three Phase
Model Number | P6SD |
---|---|
X36C | X48C |
Performance | |
Capacity -Cooling BTUH | 34,200 |
Efficiency – SEER | 13.30 |
EER (Btuh/watt) | 11.2 |
Electrical Rating – 60 Hz | |
Phase | 3 |
Operating Voltage Range | 187 – 253 |
Compressor Data | |
Volts | 208 / 230 |
Rated Load Amps | 11.6 |
Lock Rotor Amps | 73 |
Indoor Blower | |
Type | DD / 3 |
Motor – HP / RPM | 1/4 – 1075 |
Motor – Amps | 1.3 |
Outdoor Fan | |
Motor – HP / RPM | 1/4 – 1100 |
Motor – Amps | 1.2 |
Fan Diameter / CFM | 20/3600 |
Refrigerant Charge – Oz. R-410A | 110 |
Net Weight lbs. | 405 |
Shipping Weight lbs. | 415 |
Filters (Field Installed) | |
Style | Disposable |
Size (Qty) | 16 x 25 x 1 (2) |
Field convertible to two inches |
BLOWER PERFORMANCE
- P6SD Models**
Model Number P6SD-| External Static Pressure Drop – inches water column
---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
X36 *| High| 1610| 1562| 1504| 1442| 1365| 1295| 1214| 1109
Medium| 1367| 1320| 1271| 1205| 1138| 1065| 968| 845
Low| 1153| 1102| 1043| 990| 912| 831| 731| 618
X48* | High| 2361| 2278| 2218| 2141| 2066| 1976| 1870| 1758
Medium| 2026| 1982| 1935| 1889| 1822| 1744| 1660| 1554
Low| 1584| 1568| 1532| 1489| 1445| 1387| 1322| 1236
**X60 *| Tap T1| 1515| 1450| 1380| 1350| 1300| 1250| 1200| 1160
Tap T2| 1580| 1520| 1460| 1400| 1360| 1300| 1260| 1230
Tap T3| 1740| 1690| 1650| 1600| 1540| 1500| 1460| 1390
Tap T4| 1960| 1910| 1840| 1820| 1780| 1740| 1700| 1600
Tap T5**| 2090| 2050| 2010| 1975| 1940| 1900| 1850| 1790- Denotes factory-set cooling speed
- Denotes factory-set electric heating speed
NOTE: Airflow performance is with a dry coil
P6SD Models – 460V Three Phase
Model Number P6SD-| External Static Pressure Drop – inches
water column
---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
X36 | High| 1610| 1562| 1504| 1442| 1365| 1295| 1214| 1109
Medium| 1367| 1320| 1271| 1205| 1138| 1065| 968| 845
Low| 1153| 1102| 1043| 990| 912| 831| 731| 618
X48 | High| 2361| 2278| 2218| 2141| 2066| 1976| 1870| 1758
Medium| 2026| 1982| 1935| 1889| 1822| 1744| 1660| 1554
Low| 1584| 1568| 1532| 1489| 1445| 1387| 1322| 1236
**X60 *| Tap T1| 1515| 1450| 1380| 1350| 1300| 1250|
1200| 1160
Tap T2| 1580| 1520| 1460| 1400| 1360| 1300| 1260| 1230
Tap T3| 1740| 1690| 1650| 1600| 1540| 1500| 1460| 1390
Tap T4| 1960| 1910| 1840| 1820| 1780| 1740| 1700| 1600
Tap T5**| 2090| 2050| 2010| 1975| 1940| 1900| 1850| 1790
AIR CONDITIONER ELECTRICAL DATA
P6SD SERIES – 208/230V – 3 PHASE MODELS
MODEL NUMBER P6SD-| HEATER INSTALLED NOMINAL KW| SINGLE
CIRCUIT
MCA| REC, WIRE GAGE (90° C CU)| MOP
X36C| 0| 17.0| 12| 25
9| 28.7| 10| 30
15| 46.8| 8| 50
X48C| 0| 21.6| 10| 35
9| 28.7| 10| 35
15| 46.8| 8| 50
X60C| 0| 29| 10| 45
9| 29| 10| 45
15| 46.7| 8| 50
P6SD SERIES – 460V – 3 PHASE MODELS
MODEL NUMBER P6SD-| HEATER INSTALLED NOMINAL KW| SINGLE
CIRCUIT
MCA| REC, WIRE GAGE (90° C CU)| MOP
X36D| 0| 9.4| 14| 15
9| 15.1| 12| 15
15| 24.5| 10| 25
X48D| 0| 10.9| 14| 15
9| 16.2| 12| 15
15| 25.7| 10| 30
X60D| 0| 14.6| 14| 15
9| 14.9| 14| 15
15| 24.3| 10| 25
NOTE: P6SD 3 & 4 ton models have PSC motors. Since the power wires run through the heater plug, keep the blower and heater on different circuits when adding a heater kit.
HEATER APPLICATION MATRIX
TONNAGE & PHASE| UNIT| NOMINAL KW| HEATER KIT
MODEL| HEATER KIT PART NUMBER| BREAKERS REQUIRED
---|---|---|---|---|---
3,4, & 5 TON
3 Phase 208/230V
| P6SD| 9| H3HK-009Q-01B| 903854B| None
15| H3HK-015Q-01B| 903855B| None
3,4, & 5 TON
3 Phase 460V
| P6SD| 9| H3HK-009S-01B| 903850B| None
15| H3HK-015S-01B| 903851B| None
MODEL IDENTIFICATION CODE
ACCESSORIES
Description | Part Number |
---|---|
Roof Curb (8”) | 547830 |
Roof Curb (14”) | 547831 |
Roof Curb (18”) | 547850 |
Roof Curb (24”) | 547851 |
Supply/return transition, 16” | 547834 |
Supply/return transition, 18” | 547835 |
Concentric diffuser, flush, 16” | 547836 |
Concentric diffuser, flush, 18” | 547837 |
Concentric diffuser, step down 16” | 547838 |
Concentric diffuser, step down 18” | 547839 |
Manual Fresh Air Damper | 547832 |
Motorized Fresh Air Damper | 547840 |
Economizer, downflow w/filter modulating | 558870 |
Economizer, horizontal modulating | 547841 |
Power Exhaust for use with downflow economizer (208/230 3 Phase) Special
Order| 555578
Power Exhaust for use with horizontal economizer (208/230 3 Phase) Special
Order| 555580
Power Exhaust for use with downflow economizer (460V 3 Phase) Special Order|
555579
Power Exhaust for use with horizontal economizer (460V 3 Phase) Special Order|
555581
HOOD TYPE HAIL GUARD 34” X 76” (3 or 4 Ton)| 547846
HOOD TYPE HAIL GUARD 38” X 76” (5 Ton)| 547847
Differential enthalpy sensor kit| 920233
Control, CO2 sensor, wall mount| 547848
DUCT SMOKE DETECTOR PHOTO ELEC| 558863
MULTI SIGNAL CONTROL| 547893
SAMPLING TUBE DST 3, 2-4′| 558864
SAMPLING TUBE DST 5, 4-8′| 558865
Low Pressure Switch Kit| 913551
Low Ambient Kit| 918837
Freezestat| 917108
Duct Adaptor, 14″ Round (2 each)| 913812A
Outdoor Thermostat Kit| 913852
Extreme Wind Mounting Kit (roof curb mount)| 903696
Circuit Breaker, Three Phase (3-Pole)| 913740
P6SD EXPANDED RATINGS
P6SD-X36
O.D.T | 65°F | 75°F | 85°F | 95°F | 105°F | 115°F |
---|---|---|---|---|---|---|
CFM | E.D.B. | E.W.B. | T.C. | S.C. | K.W. | T.C. |
T.C. | S.C. | K.W. | T.C. | S.C. | K.W. | T.C. |
900 | 80 | 62 | 35.5 | 27.4 | 2.20 | 34.2 |
2.95 | 29.6 | 28.3 | 3.27 | 27.9 | 26.6 | 3.64 |
80 | 67 | 38.7 | 22.3 | 2.23 | 37.1 | 22.2 |
2.98 | 32.1 | 21.7 | 3.30 | 30.1 | 20.4 | 3.67 |
80 | 72 | 42.3 | 17.3 | 2.27 | 40.6 | 17.2 |
3.03 | 35.2 | 17.0 | 3.34 | 33.1 | 17.4 | 3.71 |
75 | 63 | 36.0 | 21.7 | 2.21 | 34.6 | 21.6 |
2.95 | 29.8 | 19.7 | 3.28 | 28.0 | 21.2 | 3.64 |
1000 | 80 | 62 | 36.4 | 29.1 | 2.22 | 35.0 |
28.8 | 2.96 | 30.3 | 28.7 | 3.28 | 28.7 | 28.4 |
80 | 67 | 39.4 | 23.6 | 2.24 | 37.8 | 24.3 |
2.99 | 32.6 | 23.5 | 3.31 | 30.7 | 23.7 | 3.67 |
80 | 72 | 43.1 | 18.1 | 2.27 | 41.4 | 18.9 |
3.04 | 35.8 | 18.4 | 3.35 | 33.7 | 18.5 | 3.72 |
75 | 63 | 36.7 | 22.9 | 2.21 | 35.2 | 23.5 |
2.96 | 30.4 | 22.8 | 3.28 | 28.6 | 22.7 | 3.65 |
1100 | 80 | 62 | 37.7 | 31.9 | 2.22 | 36.2 |
31.2 | 2.97 | 31.6 | 30.5 | 3.30 | 29.9 | 29.8 |
80 | 67 | 40.7 | 26.0 | 2.25 | 39.0 | 26.3 |
3.00 | 33.6 | 25.5 | 3.32 | 31.6 | 25.6 | 3.69 |
80 | 72 | 44.4 | 19.7 | 2.29 | 42.6 | 20.1 |
3.05 | 36.7 | 19.6 | 3.37 | 34.5 | 19.9 | 3.73 |
75 | 63 | 37.9 | 25.2 | 2.22 | 36.4 | 25.4 |
2.97 | 31.3 | 24.4 | 3.29 | 29.4 | 24.5 | 3.66 |
P6SD-X48
O.D.T | 65°F | 75°F | 85°F | 95°F | 105°F | 115°F |
---|---|---|---|---|---|---|
CFM | E.D.B. | E.W.B. | T.C. | S.C. | K.W. | T.C. |
T.C. | S.C. | K.W. | T.C. | S.C. | K.W. | T.C. |
1250 | 80 | 62 | 47.9 | 37.2 | 2.82 | 46.1 |
36.6 | 3.84 | 40.0 | 38.5 | 4.27 | 37.7 | 36.3 |
80 | 67 | 52.0 | 30.2 | 2.84 | 49.9 | 30.0 |
3.87 | 43.1 | 29.4 | 4.31 | 40.6 | 28.0 | 4.80 |
80 | 72 | 56.7 | 23.3 | 2.86 | 54.4 | 23.2 |
3.92 | 46.9 | 22.8 | 4.35 | 44.2 | 23.4 | 4.85 |
75 | 63 | 48.5 | 29.4 | 2.82 | 46.5 | 29.2 |
3.84 | 40.2 | 26.8 | 4.28 | 37.9 | 29.0 | 4.77 |
1400 | 80 | 62 | 49.1 | 39.8 | 2.82 | 47.3 |
39.3 | 3.85 | 41.0 | 39.2 | 4.29 | 39.0 | 38.6 |
80 | 67 | 53.1 | 32.0 | 2.84 | 51.0 | 33.0 |
3.88 | 43.9 | 32.3 | 4.32 | 41.4 | 32.3 | 4.81 |
80 | 72 | 57.8 | 24.5 | 2.87 | 55.4 | 25.6 |
3.93 | 47.7 | 24.8 | 4.36 | 44.9 | 25.0 | 4.86 |
75 | 63 | 49.5 | 31.2 | 2.83 | 47.5 | 32.0 |
3.85 | 41.0 | 31.1 | 4.29 | 38.6 | 31.1 | 4.78 |
1550 | 80 | 62 | 50.2 | 42.8 | 2.83 | 48.4 |
41.8 | 3.86 | 42.2 | 40.8 | 4.30 | 40.1 | 39.9 |
80 | 67 | 54.1 | 34.4 | 2.85 | 51.9 | 34.8 |
3.89 | 44.6 | 34.1 | 4.33 | 42.0 | 34.4 | 4.82 |
80 | 72 | 58.9 | 26.2 | 2.87 | 56.4 | 26.7 |
3.95 | 48.4 | 26.0 | 4.37 | 45.5 | 26.4 | 4.86 |
75 | 63 | 50.5 | 33.4 | 2.83 | 48.4 | 33.7 |
3.86 | 41.7 | 32.8 | 4.29 | 39.2 | 33.0 | 4.79 |
P6SD-X60
O.D.T | 65°F | 75°F | 85°F | 95°F | 105°F | 115°F |
---|---|---|---|---|---|---|
CFM | E.D.B. | E.W.B. | T.C. | S.C. | K.W. | T.C. |
T.C. | S.C. | K.W. | T.C. | S.C. | K.W. | T.C. |
1600 | 80 | 62 | 61.8 | 47.9 | 3.74 | 59.4 |
46.9 | 5.02 | 51.3 | 49.2 | 5.57 | 48.4 | 46.4 |
80 | 67 | 66.8 | 39.3 | 3.83 | 63.9 | 39.1 |
5.09 | 55.0 | 38.0 | 5.65 | 51.7 | 36.0 | 6.26 |
80 | 72 | 72.9 | 30.5 | 3.92 | 69.7 | 30.3 |
5.20 | 59.5 | 29.7 | 5.75 | 55.7 | 30.4 | 6.36 |
75 | 63 | 62.1 | 38.2 | 3.74 | 59.6 | 38.0 |
5.02 | 51.2 | 34.5 | 5.57 | 48.2 | 37.0 | 6.18 |
1750 | 80 | 62 | 63.0 | 50.5 | 3.79 | 60.5 |
49.6 | 5.07 | 52.2 | 49.4 | 5.62 | 49.3 | 48.8 |
80 | 67 | 67.8 | 41.2 | 3.87 | 64.9 | 42.3 |
5.14 | 55.7 | 40.7 | 5.70 | 52.3 | 40.6 | 6.31 |
80 | 72 | 73.7 | 31.6 | 3.97 | 70.4 | 33.0 |
5.24 | 59.9 | 31.8 | 5.79 | 56.2 | 31.9 | 6.41 |
75 | 63 | 63.2 | 40.0 | 3.81 | 60.6 | 41.0 |
5.07 | 51.9 | 39.2 | 5.62 | 48.8 | 39.0 | 6.23 |
1900 | 80 | 62 | 64.0 | 53.6 | 3.85 | 61.4 |
52.2 | 5.13 | 53.1 | 51.3 | 5.68 | 50.4 | 50.1 |
80 | 67 | 68.7 | 43.6 | 3.92 | 65.8 | 44.1 |
5.20 | 56.3 | 42.4 | 5.75 | 52.8 | 42.6 | 6.36 |
80 | 72 | 74.3 | 33.5 | 4.02 | 70.8 | 34.1 |
5.29 | 60.5 | 32.8 | 5.84 | 56.7 | 33.1 | 6.46 |
75 | 63 | 64.1 | 42.3 | 3.85 | 61.4 | 42.6 |
5.12 | 52.5 | 40.7 | 5.66 | 49.3 | 40.8 | 6.28 |
GENERAL TERMS OF LIMITED WARRANTY
NORDYNE will furnish a replacement for any part of this product by the terms
of the warranty. For complete details of the Limited Warranty, including
applicable terms and conditions, see your local installer or contact the
NORDYNE warranty department for a copy.
8000 Phoenix Parkway | O’Fallon, MO 63368-3827
Specifications and illustrations subject to change without notice and without
incurring obligations. Printed in U.S.A (09/2010) 716C-0910 (Replaces
716C-0509)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>