BSBL SLPY-02 Moving Head Light User Manual
- June 15, 2024
- BSBL
Table of Contents
BSBL SLPY-02 Moving Head Light User Manual
Please read the manual carefully beforeuse
CAUTION
DO NOT OPEN THE HOUSING SHOCK HAZARD
Please read this manual carefully before operating this product.
using a new and beautiful high temperature resistant metal body. This product is designed and produced in strict accordance with CE standards. It conforms to the international standard DMX512 signal protocol. It can be used for control alone or online. It has the characteristics of fast rotation, low noise and powerful functions. It is suitable for small and medium-sized concerts, theaters, In studios, nightclubs, bars and other places.
This product is in good condition before leaving the factory. In order to keep the product in good condition and ensure safe operation, users should follow the safety precautions and warnings in this manual.
Damage caused by not following this instruction manual is not covered by the
warranty. The supplier is not responsible for product problems caused by this.
If the product has been exposed to extreme unstable temperature environments
(such as after transportation), please do not connect the product to the power
supply immediately, as water droplets due to temperature changes may damage
the product. Please use it after the product has returned to normal
temperature.
This product can be used in the voltage range of 90-240V and is an indoor
product. Please make sure that the ground voltage used is not higher than the
product can withstand!! The power plug must be inserted into a protected Class
I socket. The green or teal conductor must be grounded.
Please check this product grade power cord frequently. Make sure the power
cord is not folded or damaged and not connected to other wires! Special
attention is required when connecting the power cord or related wiring. Always
unplug this product when not in use or before cleaning.
Before using the product, please familiarize yourself with the operating functions of the product. Please keep the product away from children or nonprofessionals. Please do not shake this product. Do not use brute force when installing or operating the product. Do not allow nonprofessionals to operate the product. Most of the damage is caused by unprofessional handling. The product is not equipped with related maintenance parts. Maintenance and repair of the product should only be carried out by professionals
Please do not modify this product without authorization, otherwise it may damage the product, so the damage caused is not covered by the warranty. Also, unprofessional handling may result in short circuits, burns or electric shocks, etc.
DMX512 Signal Connection:
This light uses the DMX512 signal control mode, and the control signals of
each light are in a parallel relationship. When connecting the signals of
multiple lights, it is best to use a double-core shielded cable. When
connecting, each lamp is connected through the DMX signal jack (XLR Socket)
INPUT (input) and OUTPUT (output) are connected, and the 3-pin XLR plug
terminals of the signal line connected to the light must correspond to each
other. When connecting the light signal, it is recommended to use a DMX signal
terminator. It can be avoided, due to electric dryness The DMX signal
terminator is a 120 Ω 1W resistor connected between pins 2 and 3 of an XLR
plug, and it is connected to the OUTPUT (output) jack of the last light.
Lamp start address code calculation method:
The starting address code of the current fixture is equal to (the starting
address code of the previous fixture) + (the number of channels of the
fixture)
Description:
- The starting address code value of the first light is A001.
- The number of basic channels of the controller should be greater than or equal to the total number of channels used by the lamps.
- Note: When using any controller, each light must have its own starting address code. If the starting address code of the first light is set to A001, and the number of light channels is 20CH; then the first The starting address code of the two lights is set to A021; the starting address code of the third light is set to A041; and so on, (this setting method also needs to be determined according to different consoles).
Light installation instructions:
The luminaire can be placed horizontally, slanted and upside down. Be sure to pay attention to the installation method when slanted and upside down. Fixed installation of the luminaire: Before positioning the luminaire, ensure the stability of the installation site. Do not fall off the lamp on the support frame, use safety ropes through the support frame and the lamp handle for auxiliary hanging; to ensure safety. Prevent the lamp from falling and sliding. When the lamp is installed and debugged, pedestrians are prohibited from passing below, and the safety is checked regularly. Whether the rope is worn, whether the hook screw is loose, and if the hanging installation is not stable, the manufacturer does not assume any responsibility for all the consequences caused by the fall of the lamp.
- Display menu description
**Menu desktop:
Menu first interface :
**
* **Address:** Click to enter address code settings
* **Setting:** Click to enter system settings
* **Manual:** Click to enter manual mode
* **Calibration:** Click to enter the password to enter the system calibration mode
* **Reset:** Click to enter system reset mode
* **Information:** Click to view system information
main menu | secondary menu | Level 3 menu/parameter |
---|---|---|
Address | 001 – 512 | (The number of channels is added each time, and the |
subtraction is normal)
system settings
| runing mode| DMX/Sound cotrol/Auto 1/Auto 2
channel mode| 20CH
horizontal inversion| On/off
vertical inversion| On/off
Hall error correction| On/off
optocoupler error correction| On/off
signal hold| On/off
screen protector| On/off
screen flip| On/off/Auto
Synchronization Update| On/off
language| Chinese/EN
MIC
| Set the sensitivity of voice control, the parameter range is 0-255,the
smaller the value, the more sensitive the detection, default value 100 .
reset|
manual mode| current channel mode channel| 0-255
System calibration| enter password| Fixture calibration
System reset| effect motor reset
Scan motor reset
Reset all motors
system message
| reset information| Display reset error message
DMX Data monitoring| Receive the channel value of the console
sensor information| Hall Information
X Optocoupler Information
Y Optocoupler Information
hardware version| Display hardware version
software version| Display software version
-
Screen auto-rotate function
The system can automatically rotate the screen according to the direction of gravitywithout manual rotation. The auto-rotate feature can also be turned off. -
Manual control
This interface is used to control the current fixture. Press the “OK” key to enter the editing state. Press the “Up” and “Down” keys tochangethe channel value. Press “OK” again to save the modified value and exit editing, press”Exit” to directly exit editing without saving the modified value -
System calibration
A layer of password is set here to prevent non-professional operation. The default password for booting is “6*”, and the default is to directly press the “OK” key toenter. Options| Description**
---|---
Initial position calibration| After entering the sub-interface, you can adjust the starting position of the X- axis, Y-axis, color wheel, pattern, prism, and focus motor to make up for the error in hardware installation. The adjustment range is 0~255, and 127 means no adjustment.
Stroke calibration| After entering the sub-interface, you can adjust the strokes of the X-axis, Y- axis, prism, and focus motor. The adjustment range is 0~255, and 127
means no adjustment.
Other calibration| Power, MIC sensitivity calibration, and password modification.
- Reset
Press the “Up” and “Down” keys to switch the reset mode, and press “OK” tor set directly.
Options | Description |
---|---|
effect motor reset | Effects motor resets other than XY |
Scan motor reset | XY axis reset |
Reset all motors | Lamp reset |
- System Information
Options| Description
---|---
reset information| If the red ERR indicator is on, it means that the lamp is running incorrectly. For details, you can enter the sub-interface to view the details.
DMX Data monitoring| From here, enter the sub-interface, and display the channel value in numerical value for viewing
sensor information| Real-time monitoring of the status of sensors such as optocouplers and Hall on the lamp
Hardware version number| Fixture hardware version
software version number| Luminaire software version - ”; Channel table:
-
20 channel Channel function Value Effect 1 X axis 0-255 0-540° 2 X-axis fine-tuning 0-255 X-axis fine-tuning 3 Y axis 0-255 0-260° 4 Y-axis fine-tuning 0-255 Y-axis fine-tuning 5 XY speed 0-255 From fast to slow **** 6 **** colorful fog 0-127 Colorful fog cut out 128-189 Fog cut in 190-255 Colorful cut in **** 7 **** Strobe 0-3 No effect 4-99 Synchronized strobe 100-149 Pulse strobe 150-199 Sharply strobe 200-249 Random strobe 250-255 consecrated 8 Total dimming 0-255 Dimming(from dark to brightness) 9 LED dimming 0-255 Dimming(from dark to brightness) 10 light strip red 0-255 Red(from dark to brightness) 11 light strip green 0-255 Green(from dark to brightness) 12 light strip blue 0-255 Blue(from dark to brightness) 13 built-in color 0-255 Foreground Color Gradient **** 14 **** Dynamic effect 0-4 No effect
5-9| Effect 1
10-14| Effect 2
15-19| Effect 3
20-24| Effect 4
25-29| Effect 5
30-34| Effect 6
35-39| Effect 7
40-44| Effect 8
45-49| Effect 9
50-54| Effect 10
55-59| Effect 11
60-64| Effect 12
65-69| Effect 13
70-74| Effect 14
75-79| Effect 15
80-84| Effect 16
85-89| Effect 17
90-94| Effect 18
95-99| Effect 19
100-104| Effect 20
105-109| Effect 21
110-114| Effect 22
115-119| Effect 23
120-124| Effect 24
125-129| Effect 25
130-134| Effect 26
135-139| Effect 27
140-144| Effect 28
145-149| Effect 29
| | 150-154| Effect 30
---|---|---|---
155-159| Effect 31
160-164| Effect 32
165-169| Effect 33
170-174| Effect 34
175-179| Effect 35
180-184| Effect 36
185-189| Effect 37
190-194| Effect 38
195-199| Effect 39
200-204| Effect 40
205-209| Effect 41
210-214| Effect 42
215-219| Effect 43
220-224| Effect 44
225-229| Effect 45
230-234| Effect 46
235-239| Effect 47
240-244| Effect 48
245-249| Effect 49
250-254| Effect 50
255| Effect 51
15| effect speed| 0-127| Forward from slow to fast
128-255| Reverse slow to fast
**** 16| **** Color disk| 0-6| White color
7-11| Color 1
12-16| Color 2
17-21| Color 3
22-26| Color 4
27-31| Color 5
32-36| Color 6
37-41| Color 7
42-46| Color 8
47-51| Color 9
52-56| Color 10
57-61| Color 11
62-66| Color 12
67-71| Color 13
72-75| White color+Color 1
76-79| Color 1+Color 2
80-83| Color 2+Color 3
84-87| Color 3+Color 4
88-91| Color 4+Color 5
92-95| Color 5+Color 6
96-99| Color 6+Color 7
100-103| Color 7+Color 8
104-107| Color 8+Color 9
108-111| Color 9+Color 10
112-115| Color 10+Color 11
116-119| Color 11+Color 12
120-123| Color 12+Color 13
124-127| Color 13+white color
| | 128-189| Counterclockwise flow from fast to slow
---|---|---|---
190-193| Stop
194-255| Clockwise flow from slow to fast
17|
Gobo wheel| 0-2| white light hole
3-6| Gobo 1
7-10| Gobo 2
11-14| Gobo 3
15-16| Gobo 4
19-22| Gobo 5
23-26| Gobo 6
27-30| Gobo 7
31-34| Gobo 8
35-38| Gobo 9
39-42| Gobo 10
43-46| Gobo 11
47-50| Gobo 12
51-54| Gobo 13
55-58| Gobo 14
59-62| Gobo 15
63-66| Gobo 16
67-70| Gobo 17
71-77| Gobo 1 shaking from slow to fast
78-84| Gobo 2 shaking from slow to fast
85-91| Gobo 3 shaking from slow to fast
92-98| Gobo 4 shaking from slow to fast
99-105| Gobo 5 shaking from slow to fast
106-112| Gobo 6 shaking from slow to fast
113-119| Gobo 7 shaking from slow to fast
120-126| Gobo 8 shaking from slow to fast
127-133| Gobo 9 shaking from slow to fast
134-140| Gobo 10 shaking from slow to fast
141-147| Gobo 11 shaking from slow to fast
148-154| Gobo 12 shaking from slow to fast
155-161| Gobo 13 shaking from slow to fast
162-168| Gobo 14 shaking from slow to fast
169-175| Gobo 15 shaking from slow to fast
176-182| Gobo 16 shaking from slow to fast
183-189| Gobo 17 shaking from slow to fast
190-221| Clockwise flow from fast to slow
222-223| Stop
224-255| Flow counterclockwise from slow to fast
18| Prims| 0-31| Prims cut out
32-63| Prims cut in
64-255| Prism rotation from slow to fast
19| Zooming| 0-255| Linear zooming
20| Reset| 0-219| No effect
220-255| Reset all
Technical parameter:
Voltage: AC90-220V 50/60Hz
Light source: 1 piece of lamp beads
Gobo: 17 patterns + white color, with two-way flow, variable speed
shaking effect
Color wheel: 13 colors + white, variable speed bi-directional rainbow
effect, fog + colorful
Prim: 8+16 prims, one-way variable speed rotation
Light strip: 44 pieces RGB 3in1
Dimming: 0-100% linear dimming
Channel: 20CH
Control mode: DMX512, Auto, Sound, Lamp beads overheat protection
Degree of protection: high-temperature plastic, IP20
With RDM function, controllable station address code
Horizontal: 540° Vertical: 270
After-sales service:
When the lamps leave the factory, they have undergone strict quality inspection, and the packaging is in good condition. Please operate according to the instruction manual. The machinefailurecaused by human reasons is not covered by the warranty.
- The company provides technical advice to customers for lifetime.
- If the product fails and needs to be repaired, please show the product warranty card and fill in there levant content truthfully. At the same time, we also hope that customers will promptly feed back the product problems to us, so that we can improve the product as soon as possible.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>