GAGGENAU 9001717285 Extractor Hood Installation Guide

June 15, 2024
Gaggenau

GAGGENAU logo Installation instructions

9001717285 Extractor Hood

GAGGENAU 9001717285 Extractor Hood - Figure

General information

  • Read this instruction manual carefully.
  • Keep the instruction manual and the product information safe for future reference or for the next owner.
  • The appliance can only be used safely if it is correctly installed according to the safety instructions. The installer is responsible for ensuring that the appliance works perfectly at its installation location.
  • This instruction manual is intended for the installer of the optional accessory.
  • Only a licensed expert may connect the appliance.
  • Switch off the power supply before carrying out any work.

Safe installation

Observe the safety instructions when installing the optional accessory.
WARNING  ‒ Risk of suffocation!
Children may put packaging material over their heads or wrap themselves up in it and suffocate.
▶ Keep packaging material away from children.
▶ Do not let children play with packaging material.
WARNING  ‒ Risk of injury!
Components inside the appliance may have sharp edges.
▶ Wear protective gloves.
The odour filter remains hot for quite some time after it has been regenerated.
▶ Do not touch the odour filter straight after it has been regenerated – allow it to cool down.
WARNING  ‒ Risk of fire!
A non-regenerable odour filter may catch fire in the oven.
▶ Only regenerable odour filters that can be regenerated.
ATTENTION!
If a regenerable odour filter falls, it may become damaged. The damage is not always visible from the outside.
▶ Dispose of and replace any regenerable odour filters that have fallen.

Included with the appliance
After unpacking all parts, check for any damage in transit and completeness of the delivery. → Fig. 1

Regenerable odour filter

Odour filters bind odorous substances in circulatingair mode. Regularly replaced or regenerated odour filters guarantee a high level of odour removal.
With normal use (daily for approx. one hour), replace the odour filter at least every 10 years.
The regenerable odour filter can be regenerated in a standard oven. With normal use (approx. 1 hour a day), the regenerable odour filter must be replaced or regenerated every 3-4  months. The regenerable odour filter can be regenerated up to 30  times.

Removing the odour filter

  1. Note:  Be aware that the filter cover is heavy.
    Press down on the locks on the filter cover. Take the filter cover in both hands and hold it tightly. → Fig. 2

  2. Open the filter cover fully and without pulling on it.

  3. Remove the grease filters.
    You can find information about removing the grease filters in the operating instructions for your appliance.

  4. Open the odour filter cartridge. → Fig. 3

  5. Note: Be aware that the odour filter is heavy.
    Take hold of the odour filter in one hand from below and remove it.

Cleaning the odour filter

ATTENTION!
Incorrect cleaning damages the regenerative odour filter.
▶ Observe the regeneration instructions.
▶ Never clean a regenerative odour filter with cleaning products, water, in the dishwasher or with a wet cloth.
▶ If the regenerative odour filters are visibly soiled, remove the dirt with a damp cloth before starting the regeneration process.
Ensure that the odour filter does not get wet.

Regenerating the odour filter

WARNING ‒ Risk of fire!
The oven cleaning function (pyrolytic self-clean) may cause a regenerable odour filter to catch fire.
▶ Never regenerate a regenerable odour filter with the oven cleaning function (pyrolytic self-clean).
WARNING ‒ Risk of injury!
The odour filter remains hot for quite some time after it has been regenerated.
▶ Do not touch the odour filter straight after it has been regenerated – allow it to cool down.

Note: During the regeneration process, parts of the odour filter may become discoloured. This discolouration has no effect on the performance of the odour filter.

Requirement:  The odour filter is removed.

  1. Preheat the oven to a maximum of 200 °C (air recirculation ).
  2. To ensure that you do not scratch the baking tray, place the odour filter on a wire rack.
  3. During regeneration, an odour may develop. Open a window to ensure that the room is well ventilated.
  4. Regenerate the regenerative odour filter with the following settings.
    Duration| Temperature| Type of heating
    ---|---|---
    120 mins| Max. 200 °C| Air recirculation
  5. Leave the hot odour filter to cool down on a heatresistant surface.

Installing the odour filter

  1. Note: Be aware that the odour filter is heavy.
    Take hold of the odour filter in one hand from below and insert it.

  2. Close the odour filter cartridge.

  3. Insert the grease filters.
    You can find information about installing the grease filters in the operating instructions for your appliance.

  4. Close the filter cover.

  5. Ensure that the filter cover locks engage correctly.

GAGGENAU 9001717285 Extractor Hood - ber code9001717285 020927