Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.


Warning

This power supply is Double Insulated and does not require connection to an Earth circuit.

Please read these instructions carefully before commencing any work.

This unit must be fitted by a competent and qualified electrician. Install in accordance with IEE Wiring regulations and current Building Regulations.

To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified electrician.

This light fitting should be connected to a circuit with a 30mA RCD fitted.

If replacing an existing fitting, make a careful note of the connections.

This product contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.


Layout

Plan the desired layout of these fittings carefully, ensuring the cables will reach the distance between the junction box and the light fitting.

Avoid locating any cables in positions that would cause a hazard. Position cables and outdoor rated junction boxes (not supplied) away from areas where they may be at risk from being cut, trapped or damaged.

We recommend that you use H05RN-F specification cable (not supplied) which is an outdoor grade, rubber sheathed cable.

The mains supply cable must have a minimum cross sectional area of 1.0mm2

Cables must be protected using suitable conduit or plastic trunking.

The products can be wall or ceiling mounted. If wall mounting ensure that the power supply is at the bottom.

Individual casings

The following individual casings are available for purchase separately.

77904 : White plain
77905 : White eyelid
77906 : White grill
77907 : Grey plain
77908 : Grey eyelid
77909 : Grey grill
77910 : Black plain
77911 : Black eyelid
77912 : Black grill
77913 : Chrome plain


Installation

Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires.

Note that the switch is turned off before installation.

Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.

  • Remove the 4 fixing screws and detach the shade. Keep safe for refitting later.

  • Hold the product in place and mark the position of the holes. Ensure the wall is capable of holding the weight of the product, or if fitting to a ceiling, ensure there is a joist at the point of fixing to support the weight of the product.

  • Knock out the chosen fixing holes.

  • Fix into position. Take care to avoid damaging any concealed wiring and pipes. The correct fixings should be used for brick, cavity walls or plasterboard.

  • Pierce a hole in the grommet, and pull the cable through.

  • Wire as detailed wiring diagram.

  • Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.

  • Refit the shade, ensuring that the seals are correctly located.

  • Gently push your chosen casing onto the shade until it clips in place.

  • Replace fuse or circuit breaker and switch on. Your light is now ready for use.

CCT Function

This product is colur changing and can be either warm white ( 3000K ) or cool white ( 4000K ) or daylight white ( 6500K ). Choose your preferred colour before installing by using the CCT switch inside the product.

A   WARM WHITE   3000K
B   COOL WHITE   4000K
C   DAYLIGHT WHITE   6500K

saxby lighting 77902 - CCT switch

  1. CCT switch
Wiring
  • This product is double insulated and must not be earthed. If there are any incoming earth cables, they must be joined together and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your property.
  • Having correctly identified the wiring from your existing light fitting, connect to the quick fit connection block in the following way, using the supplied link cables where necessary.

saxby lighting 77902 - Wiring 1

  1. INSERT CABLE
  2. PUSH DOWN

Maintained (Unswitched) Wiring: The product is on permanently and comes on during a power failure

SUPPLY                                      LIGHT FITTING

saxby lighting 77902 - Wiring 2

  1. NEUTRAL
  2. PERMANENT LIVE
  3. LINK CABLE
  4. BROWN (L)
  5. BLUE (N)

Non-Maintained Wiring: The product is normally off and comes on during a power failure

SUPPLY                                           LIGHT FITTING

saxby lighting 77902 - Wiring 3

  1. NEUTRAL
  2. PERMANENT LIVE
  3. BROWN (L)
  4. BLUE (N)

Maintained (Switched) Wiring: The product is used as a normal light – switch on/off, light turns on/off. Comes on during a power failure.

SUPPLY                                           LIGHT FITTING

saxby lighting 77902 - Wiring 4

  1. NEUTRAL
  2. SWITCHED LIVE
  3. PERMANENT LIVE
  4. BROWN (L)
  5. BLUE (N)
Check that…
  • You have correctly identified the wires.

  • The connections are tight.

  • No loose strands have been left out of the connection block.

Technical data

Supply Voltage: 220-240 V~, 50 Hz

Bulb Type: 18W LED module (SMD), 3000/4000/6500K
This product contains a light source of energy efficiency class E.

Replaceable (LED only) light source by a professional

Replaceable control gear by a professional

UKCA Conformity with all relevant UKCA Directive requirements.

Conformity with all relevant EC Directive requirements.

The power supply is Double Insulated and does not require connection to an Earth circuit.

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice.

This product is not suitable for dimming.

This product is rated at IP65.

Lumens: 120Lm in EM mode
Duration: 3 hours (180 Minutes)
Operating Temperature: 0ºC – 50ºC
Maximum Operating Humdity: 90%
Change over time: Approximately 1s
Battery Specification: LifePO4 3.2V 1500mAh
Battery Charge Time: 24 Hours
Battery warranty: 2 years


Care and Safety

We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish. For your safety, always switch off the power supply before cleaning.

Replace Cracked Shade

This light source is protected by a shade. This part must be replaced immediately should the shade become cracked or damaged. This fitting must not be used without the shade in place.

Microwave Movement Sensor

This product is fitted with a microwave movement sensor. Please see below detailed operating instructions.

Technical Specifications:
Operating voltage  220 ~ 240V AC 50/60Hz
Rated load  400W (Capacitive load) 800W (Resistive load)
Stand-by power  ≤0.5W
Sensitivity  Ceiling mounted height: 3m 
Ceiling mounted height: 6m *  100% / 75% / 50%
Wall mounted height: 2m  100% / 75% / 50% / 25% / 10%
Hold-time  5s / 30s / 90s / 3min / 20min / 30min
Daylight sensor  2Lux / 10Lux / 25Lux / 50Lux / Disable
Microwave frequency  5.8 GHz ±75MHz
Transmitting power  1mW Max.
Detection range  Ceiling mounted height: 3m 
Wall mounted height: 1.5-2m  12-15m
Detection angle  360° (Ceiling) / 120° (Wall)
Working temperature  -20°C ~ 60°C

*50%, 75%, 100% detection sensitivity is workable when installed at 6m mounting height. Only 10%, 25% sensitivity is not able to detect motion signal.

Settings:

1. Sensitivity

Sensitivity can be adjusted by selecting the combination on the DIP switches for different applications.

I –100%
II – 75%
III – 50%
IV – 25%
V ­ 10%

 | 1 | 2 | 3 |
---|---|---|---|---
I |  | |  | 100%
II | |  | | 75%
III | |  | | 50%
IV | | | | 25%
V |  | | | 10%

2. Hold-time

Hold-time refers to the time period that the light remains 100% on if no more movement is detected.

I – 5s
II – 30s
III – 90s
IV – 3min
V – 20min
VI – 30min

 | 4 | 5 | 6 |
---|---|---|---|---
I | | | | 5s
II | | | | 30s
III | | | | 90s
IV | | | | 3min
V | | | | 20min
VI | | | | 30min

3. Daylight sensor

Different daylight threshold can be preset on DIP switches. Light will always turn on upon movement if daylight sensor is disabled.

I – 2Lux
II – 10Lux
III – 25Lux
IV – 50Lux
V – Disable

 | 7 | 8 | 9 |
---|---|---|---|---
I | | | | 2Lux
II | | | | 10Lux
III | | | | 25Lux
IV | | | | 50Lux
V | | | | Disable*

*Disable means the daylight sensor does not work. The sensor will turn on light once motion is detected regardless of ambient light level.

Trouble shooting:
Malfunction Cause Remedy   Cause   Remedy
The light will not come on  Incorrect light-control setting selected  

Adjust daylight threshold setting
Faulty lamp | Replace lamp
No power supply | Check power to sensor
The lamp is always on | Continuous movement in the detection zone | Check detection area setting
The lamp is on without any identifiable movement | The sensor is not mounted for reliably detecting movement | Securely mount enclosure
Movement occurred, but not identified by the sensor (Movement behind wall, movement of small object in immediate lamp vicinity etc.) | 1. Reduce sensitivity. 2. Check the movement behind walls to avoid facilities such as water pipe, fan, which may mis-trigger the sensor.
The lamp will not work despite movement | Rapid movements are being suppressed to minimize malfunctioning or the detection radius is too small. | Check detection area setting

For further information, please visit https://www.lighting-info.co.uk/77902


V6 12/12/2022
UK Manufacturer: BH17 7BY
EU Manufacturer: Brilliant AG,
Brilliantstrasse 1, D-27442 Gnarrenburg

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

saxby lighting User Manuals

Related Manuals