R V R TLK301 Telemetry System TLK Owner’s Manual
- June 13, 2024
- R V R
Table of Contents
TELEMETRY SYSTEM
TLK
TELEMETRY SYSTEM
MODEL: TLK301
ORDERING INFORMATION
Model | Description |
---|---|
TLK301 | The telemetry systems allow for an immediate intervention in case of |
fault, thanks to the radio station remote control.
OPTION
TLK301/V1 | Telemetry unit serial for TX modular line. |
---|---|
TLK301/V2 | Telemetry unit GSM for TX modular line. |
TLK301/V3 | Telemetry unit LAN for TX modular line. |
TLK301/V4 | Telemetry unit LAN+GSM for TX modular line. |
TLK301
Telemetry System.
FEATURES
- Professional Telemetry System at SNMP V 2 level for real time control.
- Compatible with all RVR scalable transmitters: Modular (air and liquid cooled) and Hot Plug-in.
- Can remote single and dual drive transmitters.
- Integrates several interface and protocols for transmitter’s connection: RS232/RS475/I2C.
- Multiple connectivity: over IP, GSM.
- RJ45 for LAN connections, antenna for RF input for the monitor.
- Front panel with leds indicating the operating status of the system for immediate diagnosis.
- Universal Power supply.
- Can be powered with an external DC source (15-24V) to assure continuity in case of main power failure.
- Boards and main components are assembled separately for easy maintenance and upgrade.
- Slave SCMLCD4+1 systems.
TLK301
Parameters | Value | Notes |
---|
GENERALS
Ambient working temperature| °C| -10 to + 50| Whiteout condensing
POWER REQUIREMENTS ****
AC Power input| AC Supply Voltage| VAC| 80 ÷ 260 *| Full Range *
Internal switch
---|---|---|---|---
AC Apparent Power Consumption| W| 25|
Connector| | VDE IEC Standard|
| DC Supply Voltage| VDC| 12|
DC Power Input DC Current| | < 3|
FUSES
On mains| 1 External fuse F 1 A F ÷ 5X20 mm
MECHANICAL DIMENSIONS ****
Physicals dimensions | Front panel width | mm / inch | 483 / 19 | EIA rack |
---|---|---|---|---|
Front panel height | mm / inch | 44 | 1HE | |
Overall depth | mm / inch | 263 | ||
Chassis depth | mm / inch | 239 | ||
Weight | kg | About 4,3 |
INTERFACES ****
Signaling LEDS| | Yes|
---|---|---|---
Display| 40X2 Alphanumerical| | No|
Push buttons| 4 (UP, DOWN, ENTER, ESC)| | No|
USB| TELECON Protocol| | Yes|
RS232| TELECON Protocol| | Yes|
RS485| PLUG-IN Protocol| | Yes| (Only on TX PLUG-IN CA versions)
I2C| | Yes|
RJ45| LAN| | Yes| (Only on WEB versions)
SIM slot & ANTENNA| | Yes| (Only on GSM versions)
VARIOUS ****
Cooling | Convection cooling |
---|---|
Acoustic noise | dBA |
All pictures are RVR’s property and they are only indicative and not binding. The pictures can be modified without notice. These are general specifications. They show typical values and are subject to change without notice.
TELEMETRY SYSTEM
MODEL: TLK301
ORDERING INFORMATION
Model | Description |
---|---|
TLK301 | The telemetry systems allow for an immediate intervention in case of |
fault, thanks to the radio station remote control.
OPTION
TLK301/V5 | Telemetry unit serial for TX PLUG-IN-CA. |
---|---|
TLK301/V6 | Telemetry unit GSM for TX PLUG-IN-CA. |
TLK301/V7 | Telemetry unit LAN for TX PLUG-IN-CA. |
TLK301/V8 | Telemetry unit LAN+GSM for PLUG-IN-CA. |
TLK301
Telemetry System.
FEATURES
- Professional Telemetry System at SNMP V 2 level for real time control.
- Compatible with all RVR scalable transmitters: Modular (air and liquid cooled) and Hot Plug-in.
- Can remote single and dual drive transmitters.
- Integrates several interface and protocols for transmitter’s connection: RS232/RS475/I2C.
- Multiple connectivity: over IP, GSM.
- RJ45 for LAN connections, antenna for RF input for the monitor.
- Front panel with lads indicating the operating status of the system for immediate diagnosis.
- Universal Power supply.
- Can be powered with an external DC source (15-24V) to assure continuity in case of main power failure.
- Boards and main components are assembled separately for easy maintenance and upgrade.
- Slave SCMLCD4+1 systems.
TLK301
Parameters | Value | Notes |
---|
GENERALS
Ambient working temperature| °C| -10 to + 50| Whiteout condensing
POWER REQUIREMENTS ****
AC Power input
| AC Supply Voltage| VAC| 80 ÷ 260 *| Full Range * Internal switch
---|---|---|---|---
AC Apparent Power Consumption| W| 25|
Connector| | VDE IEC Standard|
| DC Supply Voltage| VDC| 12|
DC Power Input DC Current| | < 3|
FUSES
On mains| 1 External fuse F 1 A F ÷ 5X20 mm
MECHANICAL DIMENSIONS ****
Physicals dimensions | Front panel width | mm / inch | 483 / 19 | EIA rack |
---|---|---|---|---|
Front panel height | mm / inch | 44 | 1HE | |
Overall depth | mm / inch | 263 | ||
Chassis depth | mm / inch | 239 | ||
Weight | kg | About 4,3 |
INTERFACES ****
Signaling LEDS| | Yes|
---|---|---|---
Display| 40X2 Alphanumerical| | No|
Push buttons| 4 (UP, DOWN, ENTER, ESC)| | No|
USB| TELECON Protocol| | Yes|
RS232| TELECON Protocol| | Yes|
RS485| PLUG-IN Protocol| | Yes| (Only on TX PLUG-IN CA versions)
I2C| | Yes|
RJ45| LAN| | Yes| (Only on WEB versions)
SIM slot & ANTENNA| | Yes| (Only on GSM versions)
VARIOUS ****
Cooling | Convection cooling |
---|---|
Acoustic noise | dBA |
All pictures are RVR’s property and they are only indicative and not binding. The pictures can be modified without notice. These are general specifications. They show typical values and are subject to change without notice.
R.V.R. Electronica S.r.l.
Via del Fond tore 2/2
40138 Bologna – ltaly
Phone +39 0516010506
sales@rvr.it
www.rvr.it