R V R TLK301 Telemetry System TLK Owner’s Manual

June 13, 2024
R V R

TELEMETRY SYSTEM
TLK
TELEMETRY SYSTEM
MODEL: TLK301R V R TLK 301 Telemetry System TLK

ORDERING INFORMATION

Model Description
TLK301 The telemetry systems allow for an immediate intervention in case of

fault, thanks to the radio station remote control.

OPTION

TLK301/V1 Telemetry unit serial for TX modular line.
TLK301/V2 Telemetry unit GSM for TX modular line.
TLK301/V3 Telemetry unit LAN for TX modular line.
TLK301/V4 Telemetry unit LAN+GSM for TX modular line.

R V R TLK 301 Telemetry System TLKTLK301
Telemetry System.

FEATURES

  • Professional Telemetry System at SNMP V 2 level for real time control.
  • Compatible with all RVR scalable transmitters: Modular (air and liquid cooled) and Hot Plug-in.
  • Can remote single and dual drive transmitters.
  • Integrates several interface and protocols for transmitter’s connection: RS232/RS475/I2C.
  • Multiple connectivity: over IP, GSM.
  • RJ45 for LAN connections, antenna for RF input for the monitor.
  • Front panel with leds indicating the operating status of the system for immediate diagnosis.
  • Universal Power supply.
  • Can be powered with an external DC source (15-24V) to assure continuity in case of main power failure.
  • Boards and main components are assembled separately for easy maintenance and upgrade.
  • Slave SCMLCD4+1 systems.

TLK301

Parameters Value Notes

GENERALS
Ambient working temperature| °C| -10 to + 50| Whiteout condensing

POWER REQUIREMENTS ****

AC Power input| AC Supply Voltage| VAC| 80 ÷ 260 *| Full Range * Internal switch
---|---|---|---|---
AC Apparent Power Consumption| W| 25|
Connector| | VDE IEC Standard|
| DC Supply Voltage| VDC| 12|
DC Power Input DC Current| | < 3|
FUSES

On mains| 1 External fuse F 1 A F ÷ 5X20 mm

MECHANICAL DIMENSIONS ****

Physicals dimensions Front panel width mm / inch 483 / 19 EIA rack
Front panel height mm / inch 44 1HE
Overall depth mm / inch 263
Chassis depth mm / inch 239
Weight kg About 4,3

INTERFACES ****

Signaling LEDS| | Yes|
---|---|---|---
Display| 40X2 Alphanumerical| | No|
Push buttons| 4 (UP, DOWN, ENTER, ESC)| | No|
USB| TELECON Protocol| | Yes|
RS232| TELECON Protocol| | Yes|
RS485| PLUG-IN Protocol| | Yes| (Only on TX PLUG-IN CA versions)
I2C| | Yes|
RJ45| LAN| | Yes| (Only on WEB versions)
SIM slot & ANTENNA| | Yes| (Only on GSM versions)

VARIOUS ****

Cooling Convection cooling
Acoustic noise dBA

All pictures are RVR’s property and they are only indicative and not binding. The pictures can be modified without notice. These are general specifications. They show typical values and are subject to change without notice.

TELEMETRY SYSTEM
MODEL: TLK301

R V R TLK 301 Telemetry System TLK

ORDERING INFORMATION

Model Description
TLK301 The telemetry systems allow for an immediate intervention in case of

fault, thanks to the radio station remote control.

OPTION

TLK301/V5 Telemetry unit serial for TX PLUG-IN-CA.
TLK301/V6 Telemetry unit GSM for TX PLUG-IN-CA.
TLK301/V7 Telemetry unit LAN for TX PLUG-IN-CA.
TLK301/V8 Telemetry unit LAN+GSM for PLUG-IN-CA.

R V R TLK 301 Telemetry System TLKTLK301
Telemetry System.

FEATURES

  • Professional Telemetry System at SNMP V 2 level for real time control.
  • Compatible with all RVR scalable transmitters: Modular (air and liquid cooled) and Hot Plug-in.
  • Can remote single and dual drive transmitters.
  • Integrates several interface and protocols for transmitter’s connection: RS232/RS475/I2C.
  • Multiple connectivity: over IP, GSM.
  • RJ45 for LAN connections, antenna for RF input for the monitor.
  • Front panel with lads indicating the operating status of the system for immediate diagnosis.
  • Universal Power supply.
  • Can be powered with an external DC source (15-24V) to assure continuity in case of main power failure.
  • Boards and main components are assembled separately for easy maintenance and upgrade.
  • Slave SCMLCD4+1 systems.

TLK301

Parameters Value Notes

GENERALS
Ambient working temperature| °C| -10 to + 50| Whiteout condensing

POWER REQUIREMENTS ****


AC Power input

| AC Supply Voltage| VAC| 80 ÷ 260 *| Full Range * Internal switch
---|---|---|---|---
AC Apparent Power Consumption| W| 25|
Connector| | VDE IEC Standard|
| DC Supply Voltage| VDC| 12|
DC Power Input DC Current| | < 3|
FUSES

On mains| 1 External fuse F 1 A F ÷ 5X20 mm

MECHANICAL DIMENSIONS ****

Physicals dimensions Front panel width mm / inch 483 / 19 EIA rack
Front panel height mm / inch 44 1HE
Overall depth mm / inch 263
Chassis depth mm / inch 239
Weight kg About 4,3

INTERFACES ****

Signaling LEDS| | Yes|
---|---|---|---
Display| 40X2 Alphanumerical| | No|
Push buttons| 4 (UP, DOWN, ENTER, ESC)| | No|
USB| TELECON Protocol| | Yes|
RS232| TELECON Protocol| | Yes|
RS485| PLUG-IN Protocol| | Yes| (Only on TX PLUG-IN CA versions)
I2C| | Yes|
RJ45| LAN| | Yes| (Only on WEB versions)
SIM slot & ANTENNA| | Yes| (Only on GSM versions)

VARIOUS ****

Cooling Convection cooling
Acoustic noise dBA

All pictures are RVR’s property and they are only indicative and not binding. The pictures can be modified without notice. These are general specifications. They show typical values and are subject to change without notice.

R.V.R. Electronica S.r.l.
Via del Fond tore 2/2
40138 Bologna – ltaly
Phone +39 0516010506
[email protected]