Gen-Lock Reference SYNC Generator TGEN-6P OPERATION GUIDE

  • Version 1.0 / April 2020
  • Reproduction of this manual, in whole or in part, by any means, is prohibited.

Specifications

SYNCHRONIZATION
Reference Out: Tri-Level HD

Format

  • 1080p: 60/59.94/50/30/29.97/25Hz
  • 1080i: 60/59.94/50Hz
  • 720p: 60/59.94/50/30/25Hz

Accuracy

  • 2ppm

Reference In

  • Tri-Level HD & Bi-Level SD

STANDARD

  • SMPTE 274M, SMPTE 296M

PHYSICAL

  • Control: Dip-switches & Text LCD
  • Dimension: 129mm x 86m x 29mm / 5.07 x 3.38 x 1.10

Product Usage Instructions

  1. Power Supply
    Be sure to use only the standard adapter that is specified in the specification sheet. Using any other adapter could cause fire, electrical shock, or damage to the product.

  2. Power Connection
    Incorrectly connecting the power supply or replacing the battery may cause an explosion, excessive heat, or fire. Securely plug the power cord into the power receptacle. Insecure connection may cause fire.

  3. Placement
    Do not place conductive objects (e.g. screwdrivers, coins, metal items, etc.) or containers filled with water on top of the camera. Doing so may cause personal injury due to fire, electric shock, or falling objects.

  4. Installation Location
    Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fire or electric shock.

  5. Unusual Smells or Smoke
    If any unusual smells or smoke come from the unit, stop using the product. Immediately disconnect the power source and contact the service center. Continued use in such a condition may cause fire or electric shock.

  6. Malfunction
    If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in any way.

  7. Cleaning
    When cleaning, do not spray water directly onto parts of the product. Doing so may cause fire or electric shock.

FAQ

  • Q: What should I do if I notice a strange odor or the device emits fumes or smoke?
    A: Disconnect the power source immediately and consult with your supplier.

  • Q: Can I drop the converter or subject it to strong shock or vibration?
    A: No, doing so may cause damage to the product.

Gen-Lock Reference SYNC Generator

TGEN-6P OPERATION GUIDE

AIDA-TGEN-6P-Gen-Lock-Reference-Sync-Generator-01
\(1\) CAUTION:

  • TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK)
  • NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING
This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.

PRECAUTION

This exclamation point symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

WARNING
To prevent damage which may result in fire or electric shock hazard, do not expose this appliance to rain or moisture.

  1. Be sure to use only the standard adapter that is specified in the specification sheet. Using any other adapter could cause fire, electrical shock, or damage to the product.

  2. Incorrectly connecting the power supply or replacing battery may cause explosion, cause excessive heat or fire

  3. Securely plug the power cord into the power receptacle. Insecure connection may cause fire.

  4. Do not place conductive objects (e.g. screw drivers, coins, metal items, etc.) or containers filled with water on top of the camera. Doing so may cause personal injury due to fire, electric shock, or falling objects.
    Warning continues

  5. Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fire or electric shock

  6. If any unusual smells or smoke come from the unit, stop using the product. Immediately disconnect the power source and contact the service center. Continued use in such a condition may cause fire or electric shock.

  7. If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in any way.

  8. When cleaning, do not spray water directly onto parts of the product. Doing so may cause fire or electric shock.

PRECAUTION

Please read this Operation Guide before installing and using the camera & retain this copy for your reference.

  1. Always follow the instructions in the operation guide when applying power. Fire and equipment damage can occur if power is applied incorrectly. For the correct power supply,refer to the specifications page.
  2. Do not use the device if fumes, smoke or a strange odor is emitted from the device, or if ii seems not functional correctly. Disconnect the power source immediately and consult with your supplier.
  3. Do not use the device in extreme environments where high temperatures or high humidity exists. Use the device under conditions where temperatures are between 32° F – 104° F, and humidity is below 90%.
  4. To prevent damage, do not drop the converter or subject it to strong shock or vibration.

TGEN-6P

AIDA-TGEN-6P-Gen-Lock-Reference-Sync-Generator-01
\(2\)

FEATURES

  • Multi format HD Tri Level Sync up to 1080p60.
  • Both V Sync and H Sync generation for more accurate timing.
  • Up to 6 synchronized reference output per device.
  • Slave mode for cascading.
  • Built in LCD screen.
  • Built in setting dip-switches.
  • Versatile, compact, and rugged design.

OPERATION

  • SLAVE Mode
    When switch 6 is set to SLAVE, TGEN-6P will go to SLAVE mode. External reference input will be the main reference sync source. TGEN-60 will distribute external reference sync signal.

  • MASTER Mode
    When switch 6 is set to MASTER, TGEN-6P will generate reference signals set by the dip-switches.
    TGEN-6P supports 15 different HD formats

    • 720p: 60 / 59.94 / 50 / 30 / 29.97 / 25
    • 1080i: 60 / 59.94 / 50
    • 1080p: 60 / 59.94 / 50 / 30 / 29.97 / 25

720p SETTING

AIDA-TGEN-6P-Gen-Lock-Reference-Sync-Generator-01
\(4\)

1080i SETTING

AIDA-TGEN-6P-Gen-Lock-Reference-Sync-Generator-01
\(5\) 1080p SETTING

AIDA-TGEN-6P-Gen-Lock-Reference-Sync-Generator-01
\(6\)

SPECIFICATION

SYNCHRONIZATION

  • Reference Out Tri-Level HD
  • Format 1080p 60/59.94/50/30/29.97/25Hz
    • 1080i 60/59.94/50Hz
    • 720p 60/59.94/50/30/25Hz
  • Accuracy   2ppm
  • Reference In   Tri-Level HD & Bi-Level SD

STANDARD

SMPTE SMPTE 274M, SMPTE 296M

PHYSICAL

  • Control  Dip-switches & Text LCD
  • Operation Temp 32° F – 104° F
  • Dimension 1 29mm x 86m x 29mm / 5.07” x 3.38” x 1.10”
  • Weight 278g / 0.61lbs
  • Power 12VDC (+9 – +15VDC)

*Specification are subject to change without notice.

CONNECTION

AIDA-TGEN-6P-Gen-Lock-Reference-Sync-Generator-01
\(7\)

QUESTIONS

Give us a Call:
Toll Free: 844.631.8367 | Tel: 909.333.7421 Operating Hours: Mon-Fri | 8:00am – 5:00pm PST

Disposal of Old Appliances

  1. When this crossed-out wheel bin symbol is attached to a product it means the product is covered by the European Directive 2002/96/EC.
  2. All electrical and electronic products should be disposed of separately form the municipal waste stream in accordance to laws designated by the government or the local authorities.
  3. The correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health.
  4. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful inter reference in which case the user will be required to correct the interference at his own expense.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AIDA User Manuals

Related Manuals