Tip: Please do not keep the emergency keys in the safe!
COMPONENT DESCRIPTION
(1)Knob | (7) Reset button |
---|---|
(2) Emergency keyhole | (6) Lamp |
(3) Indicator light | (8) Battery box |
(4) Digital keys | (9)Socket for external battery box |
(5) Removable shelf |
Dear valued customer:
Thank you for choosing our products! You have taken an important step in organizing and protecting your most valued possessions. Every series of our safes is professionally made and designed to provide safety. Please take time to read and familiarize yourself with the proper operating procedures of your new safe presented on the following pages.
Initial Use
- Find the emergency keys in the accessories’ bag;
- Remove the emergency lock cover;
- Insert the emergency key, press gently and tum it anticlockwise, clockwise tum the knob at the same time to open the door;
CAUTION Finish operation, pull out the emergency key and keep it in a
safe place.
Insert the batteries
- With the door open;
- Insert 4×1.5V batteries into the battery box;
- Under normal condition, if the red lights are on , it means the voltage is low and you should insert new batteries.
CAUTION Replace 4 fresh batteries by lining them up in a manner as indicated by the “+” and “-” signs. When outage for longer than thirty minutes, you should reset the user code.
Open the door
- Input your user’s code(3 to 8 digits) or master code(3 to 8 digits) , each pressing results one buzzer beep and yellow light flashes;
- Press “#”, the green light will be on;
- Rotate the knob clockwise and pull outwards within 5 seconds, the door will be open;
CAUTION The preset user code “159°, There is no preset master code.Please
input the user code again if the yellow light flashes with three buzzer beeps.
Close the door
Turn the knob anticlockwise to close the door.
Automatically locked
- Three continuously wrong entrics will activate the warning beep for 20 seconds;
- Another three continuously wrong entnes will activate the warning beep for 5 minutes.
Set the user code
- With the door unlocked, press the reset button, start setting code when the yellow light gots on;
- Input the new user code(3 to & digits), and press the “B(#)” lo confirm. it will be conlirmed by 2 buzzer beeps and the yellow light flashes twice;
- If the yellow light flashes with 3 buzzer beeps, which means the code changing is not eflective, and you need to try again.
Set the master code
- With the door unlocked. input “00” and press reset button, start setting code when the yellow light goes on;
- Input the new master code(3 to 8 digits), and press the “BG” to contirm, it will be confirmed by 2 buzzer beeps and the yellow light flashes twice, then setting is done successfully;
- If the yellow light flashes with 3 buzzer beeps, which means the code changing is not effective, and you need to try again.
Mute function
- Press **633° to turn off the sound
- Press ‘*66’to tur on the sound
Mounting
- Drill holes for expansion bolts(or clamping screws) in the right place:
- Turn the expansion bolts anticlockwise to separate;
- Use the expansion bolts(or clamping screws) to secure the case to the wall:
- Make sure the case is mounted in place as required and then tighten all screws.
CAUTION Use the expansion bolt when there is a concrete wall surface.
Use the clamping screw when there is a wooden wall surface.
Parts list:
Item | Picture | Qty | Item | Picture | Qty |
---|---|---|---|---|---|
Emergency key | 2 | Mounting screw | 4 | ||
Instruction book | 1 | Fireproof bag | 1 | ||
Mat | 1 |
Please keep the emergency keys out of the safe.