Aida R1815D60CCA Combination Receptacle USB Charger Instruction Manual
- June 6, 2024
- AIDA
Table of Contents
Aida R1815D60CCA Combination Receptacle USB Charger Instruction Manual
Applicable Model Number
R1815D6OCCA
R1815D6OAAA
R1815D54AA
R1815054AC
R1815D0C30AA
R1815DPD2OAC
R1820D6OCCA
R1820D6OAAA
R1820D54AA
R1820D54AC
R1820DQC30AA
R1820DPD2OAC
R1815D6OAAC
R1815D5OAA
R1815D5OAC
R1815D6OCC
R1815DQC3OAC
R1815DPD2OCC
R1820D6OAAC
R1820D5OAA
R1820D5OAC
R1820D6OCC
R1820DQC3OAC
R1820DPD2OCC
FEATURES
- Charge most compatible electrical device directly without an adapter.
- If the devices combined power requirements exceed the power capacity of the USB ports, the charger will shut down to protect your electrical devices.
- Replace a standard duplex receptacle.
- The USB ports are used to charge portable electronic devices ONLY (NO data transfer capability).
- Back wire for easy installation.
COMPATIBILITY
The USB charger is compatible with USB powered devices such as:
- iPad/’
- GPS
- E-Readers
- Bluetooth
- iPhon&
- Game Systems
- Blackberry
- Headsets
- iPod
- Mobile Phones
- Tablets
- Digital Cameras
REPLACEABLE TOP COVER
If necessary, pry four corners of the top cover for replacing top covers of different color.
WARNINGS AND CAUTIONS
- To be installed and used in accordance with appropriate code and regulations.
- If you are not sure about any part of these instructions, consult an electrician.
- To be used with Class 2 connectors with interconnecting cables.
- The Class 2 USB ports are not intended for use with appliances and supporting products.
- All connected Class 2 output cables must be routed away from the receptacle slots or any plug / cord inserted into the receptacle.
- Use this device with copper or copper clad wire only.
INSTALLATION
-
WARNINGS AND CAUTIONS: TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING! AVERTISSEMENTS ET MISES EN GARDE: POUR EVITER TOUT INCENDIE, TOUT CHOC OU LA MORT, COUPEZ LE DISJONCTEUR OU LE FUSIBLE ET TESTEZ QUE L’ALIMENTATION EST COUPEE AVANT LE CABLAGE!
-
This device is to be installed in a wall box measuring at least 3″ x 2″ x 2-1/2″ (standard single gang electrical wall box) and wired in accordance with NEC article 314 box fill requirements.
-
Connect wires per WIRING DIAGRAM as follows. To back wire, insert wires through terminal holes in the back, tighten terminal screws clockwise firmly. The 1.6 N-m terminal tightening torque is assigned.
NOTE: Back wire terminals accept #14 – #12 AWG copper or copper clad wires only. -
Mount device in wall box with screws provided and mount wall plate.
-
Restore power at circuit breaker or fuse. Installation is complete.
WIRING DIAGRAM
SPECIFICATION
Receptacle Rating | 15 Amp or 20 Amp, 125V AC |
---|---|
USB Rating | Refer to the overleaf |
Wiring Gauge | #14 – #12 AWG |
Operating Temperature | -4 to 104vF(-20 to 40°C) |
Dimension | 4.17×1.69×1.65″ (106x43x42mm) |
Aida Corporation
9855 Mining Drive, Unit 202, Jacksonville, Florida 32257
www.aidacorp.com Tel:
904-404-8977 Toll Free:
844-808-4435
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>