Table of Contents
- Prepare cable for mass fiber splice cassette installation.
- Remove cassette cover
- Prepare to place feeder fiber in cassette
- Install feeder fiber in splice cassette
- Measure and trim pigtail and feeder
- Install splice protectors on all fibers to be spliced
- Splice feeder and pigtail fibers
- Preparing to load splice protectors
- Load splice protectors into splice holder
- Route fibers into base
- Apply Cover
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
COMMSCOPE TC-96275-IP Single Fiber Splice Cassette for Propel Panel
Prepare cable for mass fiber splice cassette installation.
Refer to Table 1 for Feeder and Pigtail Lengths. “Feeder Initial Length” is the recommended length of fiber to bring into the cassette. “Feeder Cut Length” and “Pigtail Cut Length” is measured from the front of the cassette and is the recommended cut length for the initial splice. A maximum of (1) rework is allowed per splice.
Table 1: Pigtail and Feeder Lengths
Feeder Initial Length (in)| Feeder Cut Length (in)| Pigtail Cut Length (in)|
Fiber Inside Propel Panel (in)
---|---|---|---
25(63.5 cm)| 17.25 (43.8 cm)| 20.5 (52 cm)| 21 (53.3 cm)
Remove cassette cover
Using thumb & finger, disengage rear tab by lifting and pulling backward to
remove the cover.
Prepare to place feeder fiber in cassette
-
(a) Remove spool and splice holder from cassette, then remove and discard foam blocks.
-
(b) Unspool and extend pigtail fiber beyond front of cassette.
Install feeder fiber in splice cassette
-
(a) Insert plastic sleeve into mesh sleeve and secure using tape. Insert feeder fiber into sleeve.
-
(b) Secure feeder fiber using two cable ties.
-
(c) Snip off ends of cable ties close to head.
-
(d) Push the head downward until it is below the top of the cassette wall.
Measure and trim pigtail and feeder
Extend feeder fibers beyond the front of the cassette base, then measure and
trim pigtail and feeder to specified cut length per Table 1.
Install splice protectors on all fibers to be spliced
Use provided splice protectors. Splice protector length should be 45mm
maximum.
Splice feeder and pigtail fibers
Strip, clean, and splice fibers following recommended method.
Preparing to load splice protectors
Locate “P” and “F” marking on spool. When loading splice protectors, ensure
pigtail is exiting spool through the side with “P” marking and the feeder is
exiting through the side with “F” marking.
Load splice protectors into splice holder
-
(a) Load splice protectors into splice holder
-
(b) Utilizing the spool fiber retainers, route pigtail fibers counterclockwise until feeder and pigtail fibers converge.
Route fibers into base
-
(a) Position spool to prepare for routing.
-
(b) Route pigtail and feeder fibers counterclockwise starting along the outer walls and working towards the center of the cassette.
-
(c) Line up the pegs on the cassette base with the mounting holes on the spool to finish routing.
-
(d) Insert spool into base and ensure all fibers are under retaining fingers.
Apply Cover
-
(a) Line the tabs on the cover with the slots near the front of the cassette base.
-
(b) Lay the cover flat on the base and ensure all the tabs on the side of the cover and bases are lined up. With one hand holding the cassette base, push cover forward with other hand to engage tabs. Double check the rear tab is also engaged to prevent the cover from sliding off.
Customer Support
Product Information
http://www.commscope.com
Product Information
http://www.commscope.com/SupportCenter
© 2023, CommScope, Inc. All Rights Reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>