X3-Fit-G4 Retro Fit Solar Power Inverter
X3-Fit-G4
Installation Manual
X3-Fit-6.0-W / X3-Fit-8.0-W
X3-Fit-10.0-W / X3-Fit-10.0K-W
X3-Fit-15.0-W
Safety
General Notice
-
Contents may be periodically updated or revised. SolaX reserves the right to make
improvements or changes in the product(s) and the program(s) described in this manual
without the prior notice. -
The installation, maintenance and grid-related setting can only be performed by
qualified personnel who:
• Are licensed and/or satisfy state and local jurisdiction regulations;
• Have good knowledge of this manual and other related documents. -
Before installing the device, carefully read, fully understand and strictly follow the
detailed instruction of the user manual and other related regulations. SolaX shall not
be liable for any consequences caused by the violation of the storage, transportation,
installation, and operation regulations specified in this document and the user manual. -
Use insulated tools when installing the device. Individual protective tools must be worn
during installation, electrical connection and maintenance. -
Please visit the website www.solaxpower.com of SolaX for more information.
Descriptions of Labels
DANGER!
Lethal danger from electrical shock due to the inverter
• Only operate the inverter when it is technically faultless. Otherwise,
electric shock or
fire may occur.
• Do not open the enclosure in any case without authorization from SolaX.
Unauthorized opening will void the warranty and cause lethal danger or serious
injury due to electric shock.
WARNING!
Risk of personnel injury or inverter damage
• During operation, do not touch any parts other than DC switch and LCD panel.
• Never connect or disconnect the AC and DC connectors when the inverter is
running.
• Turn off the AC and DC power and disconnect them from the inverter, wait for
5
minutes to fully discharge the voltage before attempting any maintenance,
cleaning
or working on any circuits connected.
• Make sure that the input DC voltage ≤ Maximum DC input voltage of the
inverter.
Overvoltage may cause permanent damage to the inverter, which is NOT covered
by
the warranty.
CAUTION!
• Keep children away from the inverter.
• Pay attention to the weight of the inverter. Personal injuries may be caused
if not
handled properly.
NOTICE!
• If an external RCD is required by local regulations, check which type of RCD
is
required for relevant electric codes. It is recommended to use a Type-A RCD
with
the value of 300 mA.
• All the product labels and nameplate on the inverter shall be maintained
clearly
visible.
Packing List
Item Quantity
Inverter 1 pc
Bracket 1 pc
AC protective cover 1 pc
6 mm² ferrules 12 pcs
OT terminal 1 pc
Expansion tubes & expansion bolts & screws & washers 5 pairs
M5 inner hexagon screw 1 pc
Waterproof connectors with RJ45 3 pairs
Positive & negative battery connectors 1 pair
Positive & negative battery pin contacts 1 pair
RJ45 terminals 6 pcs
Documents /
Wifi dongle (optional) 1 pc
RJ45 connector 1 pc
- Refer to the actual delivery for the optional accessories.
Installation Site
Installation Carrier
The Weight of X3-Fit Series Inverters
Inverter – X3-Fit-6.0-W, X3-Fit-8.0-W, X3-Fit-10.0-W, X3-Fit-10.0K-W,
X3-Fit-15.0-W
Weight – (KG) 25.0 25.0 25.0 26.5
Installation Angle
Installation Space
Installation Tools
Additionally Required Materials
No.| Required Material| Type|
Conductor Cross-section
---|---|---|---
1| Communication wire| Conventional yellow and green wire| 0.2 mm²
2| Additional PE wire| Conventional yellow and green wire| 4 mm²
• Grid Wire and Micro-breaker Recommended
Model| X3-Fit-6.0-W| X3-Fit-8.0-W| X3-Fit-10.0-W
X3-Fit-10.0K-W| X3-Fit-15.0-W
---|---|---|---|---
Five-core wire (copper)| 4~6 mm²| 4~6 mm²| 5~6 mm²| 5~6 mm²
Micro-breaker| 20 A| 32 A| 40 A| 40 A
• EPS (Off-grid) Wire and Micro-breaker Recommended
Model| X3-Fit-6.0-W| X3-Fit-8.0-W| X3-Fit-10.0-W
X3-Fit-10.0K-W| X3-Fit-15.0-W
---|---|---|---|---
Four-core wire (copper)| 4~6 mm²| 4~6 mm²| 4~6 mm²| 5~6 mm²
Micro-breaker| 16 A| 20 A| 25 A| 32 A
- The diameter of Grid and EPS cables should be < Ø 18.
• Lead-acid Battery Breaker Recommended
Model| X3-Fit-6.0-W| X3-Fit-8.0-W| X3-Fit-10.0-W
X3-Fit-10.0K-W| X3-Fit-15.0-W
---|---|---|---|---
Voltage| Nominal voltage of DC breaker should be larger than maximum
voltage of battery.
Current| 32 A
Mechanical Installation
PE Connection
Grid and EPS (Off-grid) Connection
PV Connection
1. Battery connection diagram
2. Compatible batteries
| Battery Control| Battery Modules
---|---|---
Battery & Quantity| T-BAT 5.8 (1 pc)|
HV11550 (1-3 pcs)
Battery & Quantity| MC0600 (1 pc)|
HV10230 (2-4 pcs)
Battery & Quantity| TBMS-MCR0800 (1 pc)|
TP-HR25 (4~13 pcs)*
Battery & Quantity| TBMS-MCR0800 (1 pc)|
TP-HR36 (4~13 pcs)*
Battery & Quantity| TBMS-MCR0800 (1 pc)|
TP-HR25 (4~13 pcs)*
Battery & Quantity| TBMS-MCR0800 (1 pc)|
TP-HR36 (4~13 pcs)*
Note:
- For X3-Hybrid-5.5-D LV and X3-Hybrid-8.3-D LV inverters, only 4~12 pieces of battery
modules (TP-HR25/ TP-HR36/ TP-HS25/ TP-HS36) and one piece of TBMS-MCS0800 can
be installed together with an inverter.
HV11550 battery modules have V1 and V2 versions, V1 and V2 with the same number of
inverters, the specific collocation can refer to the relevant part of the battery manual.
3. Battery connection steps
Communication Connection
• CAN1/CAN2/DRM/OFF port connection
2. Cable connection steps
- Please ground the GND terminal of Meter1 if you want to connect a meter.
2. Pin definition for Meter
Item | Meter |
---|---|
Pin | 1 |
Pin Definition | X |
3. Cable connection steps
• COM port connection
1. Pin definition for COM
Item | COM |
---|---|
Pin | 1 |
Pin Definition | Drycontact |
_A(in) | Drycontact |
_B(in) | +13V |
_A(out) | XDrycontact |
_B(out)
NOTE: Pin 3 cannot be short-circuited with any other pin in case of the
possible damage
of an inverter.
- You can control the inverter and other external devices through the COM interface.
Professional users can use pins 4 and 5 to realize data acquisition and external control
functions. The communication protocol is Modbus RTU. For details, please contact us.
2. Situation of external equipment controlled by the inverter
• BMS port connection
1. Pin definition for BMS
Item BMS
Pin 1 2 3 4 5 6 7 8
Pin Definition EXT_NTC GND GND BMS_CANH BMS_CANL X BMS_485A BMS_485B
- The communication port on the lithium battery must be consistent with the definition of
pins 4, 5, 7 and 8 above.
2. For BMS cable making, please refer to the cable connection steps of the
COM port. Then
insert the well connected cable into the BMS port of the inverter and screw it
tightly.
Monitoring Connection
Power on the System
LED Panel
-
In a normal state, the “Power”, “Today” and “Battery” information will be displayed. You
can press the keys to switch information. -
In an error state, the fault message and error code will be displayed, please refer to
corresponding solutions in the user manual.
General Setting
- The options under password 2014 are for advanced setting. Change the password in
time.
Wi-Fi Configuration
Technical Data