Miele 518 HW Heated with Hot Water Instruction Manual

June 15, 2024
Miele

Miele 518 HW Heated with Hot Water

Miele-518-HW-Heated-with-Hot-Water-PRODUCT

Specifications

  • Model: PDR 918/518 HW
  • Heating Method: Hot water
  • Installation: Commercial tumble dryers

Product Usage Instructions

Installation

To install the PDR 918/518 HW heated with a hot water tumble dryer, please follow the steps below:

  1. Ensure that you have an on-site circulation system with feed and return lines to supply the tumble dryer with hot water as an energy source.
  2. If needed, purchase the optional installation kit from Miele to assist with connecting the hot water supply to the tumble dryer.
  3. Install shut-off valves at the feed line and return line connection points.
  4. Provide additional ventilation at the connection point on-site if required for cable routing.
  5. Connect the ducting properly and ensure that the room is sufficiently ventilated before operating the tumble dryer.
  6. Only use accessories approved by Miele. Using other parts may invalidate warranty, performance, and product liability claims.

Dimensions

The dimensions of the PDR 918/518 HW heated with hot water tumble dryer are as follows:

  • Height: 1400 mm
  • Width: 595 mm
  • Depth: 650 mm

Technical Data

The technical data for the PDR 918/518 HW heated with hot water tumble dryer are as follows:

  • Supply Voltage: Variable
  • Frequency: Variable
  • Power Rating: Variable
  • Fuse Rating (on site): Variable
  • Minimum Cross-section for Connection Cable: Variable
  • Cable Gland: Variable
  • Maximum Nominal Volume Flow Rate in Extraction Mode: 200 Pa (for PDR 9xx models only)
  • Maximum Nominal Volume Flow Rate: Variable (for PDR 5xx models only)
  • Maximum Permitted Pressure Loss: 150 mm
  • Maximum Exhaust Air Temperature: Variable
  • Hot Water Feed Temperature: < 15 K, 1000 kPa
  • Hot Water Return: Threaded union (external thread)
  • Hot Water Valve Connection: Variable

FAQ

Q: Do I need to purchase the installation kit separately?

  • A: Yes, an installation kit is available as an optional accessory to assist with connecting the hot water supply to the tumble dryer.

Q: Can I use accessories that are not approved by Miele?

  • A: No, only use accessories that are expressly approved by Miele. Using other parts may invalidate warranty, performance, and product liability claims.

Q: What are the dimensions of the tumble dryer?

  • A: The dimensions of the PDR 918/518 HW heated with hot water tumble dryer are approximately 1400 mm (height) x 595 mm (width) x 650 mm (depth).

Q: What is the maximum exhaust air temperature?

  • A: The maximum exhaust air temperature is variable and depends on the specific model and operating conditions.

Installation notes

Installation requirements

  • Risk of injury or damage to property due to improper installation.
  • Incorrect installation of the tumble dryer can lead to personal injury or damage to property.
  • The tumble dryer must only be installed and commissioned by the Miele Customer Service Department or an authorized dealer.
  • The tumble dryer must be installed under all relevant regulations and standards.
  • The dryer must only be operated in a room that has sufficient ventilation and which is frost-free.
  • The tumble dryer must not be installed behind a closed door or a sliding door. The maximum opening angle of the tumble dryer door must not be limited by objects or doors.
  • It must be possible to fully open the tumble dryer door at any time.

Electrical connection

  • The electrical connection must be established by a qualified electrician.
  • The electrical connection may only be made to an electrical system provided under all appropriate local and national legislation, regulations, and guidelines.
  • Please also observe the regulations set out by your insurance provider and energy supplier, accident prevention regulations, as well as recognized codes of practice.
  • The reliable and safe operation of this tumble dryer is only ensured if it has been connected to the mains electricity supply.
  • The required supply voltage, power rating, and fuse rating can be found on the data plate on the tumble dryer. Ensure that the supply voltage matches the voltage quoted on the data plate before establishing the electrical connection to the tumble dryer.
  • Connection to a supply voltage other than the one quoted on the data plate can damage the tumble dryer if the voltage is too high.
  • If more than one voltage is specified on the data plate, the tumble dryer can be converted for connection to the relevant input voltage.
  • This conversion must be performed by the Miele Customer Service Department or by an authorized dealer. During the conversion, the wiring instructions given on the wiring diagram must be followed.
  • The tumble dryer can either be connected with a suitable plug-and-socket under IEC 60309-1 or where necessary a hard-wired connection.
  • For a hard-wired connection, an all-pole isolation device must be available at the installation site.
  • An isolation device is a switch that ensures a contact opening of more than 3 mm. These include circuit breakers, fuses, and contractors (IEC/EN 60947).
  • If the mains supply cannot be permanently disconnected, the isolation device (including plug and socket) must be safeguarded against being switched on either unintentionally or without authorization.
  • Tip: We recommend connecting the tumble dryer to the power supply via a plug and socket so that it is easier to conduct electrical safety checks (e.g. during maintenance or repair work).
  • The tumble dryer must not be connected to devices such as timers which would switch it off automatically.
  • If local regulations require that a residual current device (RCD) is installed, a type B residual current device (sensitive to universal current) must be used.
  • If local and national installation specifications require equipotential bonding, good galvanic contact must be guaranteed. Equipotential bonding must have an earth current rating > 10 mA.

Hot water connection

  • An on-site circulation system with feed and return lines is required to supply the tumble dryer with hot water as an energy source.
  • For sufficient protection against corrosion, the tumble dryer must only be operated with heating water in compliance with VDI 2035.
  • A detailed pipework calculation and hydraulic alignment of the overall system are recommended to ensure adequate heat supply at the appliance.
  • This applies in particular when connecting multiple appliances to the same heating circuit.
  • An external circulation pump needs to be installed in the heating cir-cuit on site to ensure a sufficient supply of hot water.
  • The circulation pump must be selected based on the technical specifications of the tumble dryer and those of the on-site pipework.
  • Flexible hose connections that are resistant to pressure and temperature are recommended for the connection of the hot water supply.
  • The cross-section of the free internal diameter of the connection hoses must be at least 18 mm so that the flow rate throughout the heating circuit can be maintained at a sufficient level. If it is not, the program running time of the drying process is likely to be affected.
  • A suitable control valve must be fitted in the feed line to control the incoming flow of hot water. This valve is controlled directly via the tumble dryer controls.
  • The control valve must be fitted in the direct vicinity of the appliance connection.
  • An installation kit to assist with connecting the hot water supply to the tumble dryer is available to purchase as an optional Miele accessory.
  • We recommend that shut-off valves are fitted on-site at the feed line and return line connection points.
  • Depending on cable routing requirements, the customer might need to provide additional ventilation at the connection point on site.

Air intake/exhaust air

  • The tumble dryer may only be operated when the ducting has been connected properly and the room is sufficiently ventilated.
  • Accessory parts may only be fitted when expressly approved by Miele. If other parts are used, warranty, performance, and product liability claims will be invalidated.

PDR 918/518, heated with hot water

Dimensions

Dimensions quoted in millimetres

Installation

Miele-518-HW-Heated-with-Hot-Water-FIG-2

  • Dimensions quoted in millimetres
  • EL Electrical connection
  • HWA Hot water valve connection
  • HWV Hot water valve
  • VL Hot water feed
  • RL Hot water return
  • AL Exhaust duct
  • ZL Air intake
  • PA Connection for equipotential bonding (optional)
  • XCI XCI Box/Connector Box (optional)

Installation (standard/UG)Miele-518-HW-Heated-with-Hot-Water-
FIG-3

Dimensions quoted in millimetres

  • B Drill hole/anchor point
  • UG Box plinth

Installation (on concrete plinth/offshore)Miele-518-HW-Heated-with-Hot-
Water-FIG-4

Dimensions quoted in millimetres

  • BS Concrete plinth
  • B Drill hole/anchor point

Technical data

Voltage variants and electrical data

  • Standard connection
  • Supply voltage 1N AC 230 V
  • Frequency 50/60 Hz
  • Power rating 0.6 kW
  • Fuse rating (on site) 10 A
  • Minimum cross-section for connection cable 3×1.5 mm²
  • Cable gland M20

Exhaust air

  • Maximum nominal volume flow rate in extraction mode (PDR 9xx only) 715 m³/h
  • Maximum nominal volume flow rate (PDR 5xx only) 550 m³/h
  • Maximum permitted pressure loss 200 Pa
  • Connector on machine side (external diameter) 150 mm
  • Connection pipe provided on-site (internal diameter) 150 mm
  • Maximum exhaust air temperature 80 °C
  • As relative humidity inside the exhaust ducting can be as high as 100 %, suitable measures must be taken to prevent a backflow of condensate into the machine.

Hot water feed

  • Rated load 5.9 kW
  • Media temperature operating range 70–90 °C
  • Flow rate operating range 0.3–1.5 m³/h
  • Temperature difference feed/return < 15 K
  • Maximum operating pressur e 1000 kPa
  • Resistance value at nominal rating (flow rate 1 m³/h) 1 kPa
  • Threaded union (external thread) ½”

Hot water return

  • Threaded union (external thread) ½”

Hot water valve connection

  • Supply voltage 1N AC 230 V
  • Frequency 50 Hz
  • Maximum permitted connection load 0.5 A
  • Length of connection cable for control valve 500 mm

Hot water valve

  • Minimum media temperature 100 °C
  • Pressure range 0–10 bar
  • Minimum differential pressure at the control valve (pressureless for circulation system) 0 bar
  • Minimum flow factor (kv value) 6.0 m³/h

Air intake

  • Standard connection: air intake from the installation site
  • Recommended free air intake cross-section into the room: (equivalent to 3 times the exhaust air cross-section of a machine). 531 cm²
  • There must be sufficient air intake at the installation site to match the air outlet volume.
  • Alternative connection: air intake connection directly from outdoors
  • Connection sleeve on machine side (internal diameter) 161 mm
  • Connection pipe provided on-site (external diameter) 160 mm
  • Removing the protective cover exposes live parts. For safety reasons, a pipe must be installed from the tumble dryer’s central fresh air intake (over a minimum length of 900 mm) and secured with 2 screws.

Equipotential bonding (optional)|
---|---
Connection with male thread| 10×35 mm
Washers and nuts| M10
Accessories for equipotential bonding are not supplied and need to be ordered separately.|
Machine data|
Machine width, total| 906 mm
Machine height, total| 1400 mm
Machine depth, total| 1035 mm
Niche width| 1250 mm
Recommended wall spacing (up to the front edge of the machine)| 1500 mm
Minimum wall spacing (up to the back edge of the lid)| 500 mm
Packaging width| 1090 mm
Packaging height| 1526 mm
Packaging depth| 1125 mm
Maximum gross volume| 1871.3 l
Maximum gross weight| 221.3 kg
Maximum net weight| 207.5 kg
Max. floor load in operation| 2300 N
Diameter of exhaust duct| 150 mm
Drum diameter| 850 mm
Diameter of drum opening| 520 mm
Drum depth| 613 mm
Drum volume| 325 l
Diameter of door opening| 520 mm
Maximum door opening angle| 180°
Emission sound pressure level| 50 dB(A) re 20 µPa
Sound power level| 61
Average heat dissipation rate in the room| 4.5 MJ/h
Permissible ambient temperature range| 2–40 °C

Fixing options

Fixing without plinth

  • Quantity Screw size
  • Tensioning strips 2
  • Wood screws DIN 571 (Ø × length) 2 6×40 mm
  • Plugs (Ø × length) 2 10×50 mm
  • If the tumble dryer is being installed without a plinth, fixing it in place is recommended.
  • Fastenings for floating screed must be supplied by the customer on-site.
Fixing to concrete plinth
  • Quantity Screw size
  • Tensioning strips 2
  • Wood screws DIN 571 (Ø × length) 2 6×40 mm
  • Plugs (Ø × length) 2 10×50 mm
  • If the tumble dryer is being fixed to a concrete plinth on-site, fixing it in place is essential.
  • Fastenings for floating screed must be supplied by the customer on-site.

Fixing to Miele plinth

  • Quantity Screw size
  • Tensioning strips 4
  • Wood screws DIN 571 (Ø × length) 4 8×65 mm
  • Plugs (Ø × length) 4 12×60 mm
  • If the tumble dryer is being fixed to a Miele plinth (an optional accessory available to purchase separately), fixing in place is essential.
  • Fastenings for floating screed must be supplied by the customer on-site.

Options/Accessories|
---|---
Miele plinth (optional accessory available to purchase separately)
Width| 900 mm
Height| 127 mm
Depth| 868 mm
Concrete base (on site)|
Minimum width| 900 mm
Recommended height| 100 mm
Minimum height| 50 mm
Minimum depth| 1100 mm
The quality of the concrete and its strength must be assessed according to the machine load. The on-site concrete plinth must be fixed adequately to the floor.