DOMETIC CA27100P Neutral Start Switch Kit Instruction Manual
- June 15, 2024
- Dometic
Table of Contents
INSTALLATION INSTRUCTIONS
Copy Part# IS-CA27100, Rev. 2
Date: 03/2023
Neutral Start Switch Kit
Part # CA27100P — (waterproof) for CH2300P controls
NOTICE!
Installer: these instructions contain important safety information and must be
forwarded to the boat owner.
This kit contains necessary parts to provide `start-in-gear protection’ by allowing the starter motor to be engaged only when the control is in “neutral’. Use this kit only with marine engines that use a solenoid for control of the starter motor. Do not substitute parts.
Place the switch (item 2) on the control (item 1) as shown in figure 1 so that the roller of the switch contacts the stamped metal cam of the control while the control is in the neutral position.
NOTE
Mount the switch so that the arm is up against the pin as shown in figure 2.
Item No. | Description | Qty. |
---|
1
2
3
4
| Control
Switch
Screw
Label (White)|
–
1
2
1
Figure 1.
4. THIS CONTROL WILL PROVIDE START-IN-GEAR PROTECTION MEETING USCG REQUIREMENTS OF 33 CFR PART 183. SUBPART L.
Route the wires so they will not in any way come in contact with the cable or moving parts of the control. If necessary, the switch can be mounted on the right side (left side mounting shown in figure 1). Connect one wire of the switch to the `start’ terminal on the ignition switch and the other to the positive terminal of the starter solenoid (see figure 2 and warning).
Locate the red label on the control stating “this control will not provide start-in-gear protection…” and replace it with the white label provided in this kit (item 4) which states “this control will provide start-in-gear protection…”. This is done to comply with United States Coast Guard regulations (33 CFR part 183, subpart L) which requires controls to identify its ability to provide start-in-gear protection.
If no red label is present then install the white label on any clean, smooth surface of the control.
Figure 2.
- ARM
- PIN
- START TERMINAL
- IGNITION SWITCH
- GROUND
- SOLENOID
WARNING!
Connection to the ground (-) terminal of the solenoid will short circuit and
destroy this switch.
Check for correct operation by trying to start the engine at all gear lever positions. If the engine starts in either forward or reverse positions, check connection at ignition switch.
YOUR LOCAL DEALER
dometic.com/dealer
YOUR LOCAL SUPPORT
dometic.com/contact
YOUR LOCAL SALES OFFICE
dometic.com/sales-offices
A complete list of Dometic companies, which comprise the Dometic Group, can be found in the public filings of: DOMETIC GROUP AB Hemvärnsgatan 15 SE-17154 Solna Sweden
4445104036 IS-CA27100 2023-03-20