SAFEWAZE 019-4005 Temporary Reusable Roof Anchor Instruction Manual
- June 15, 2024
- SAFEWAZE
Table of Contents
- SAFEWAZE 019-4005 Temporary Reusable Roof Anchor
- INTRODUCTION
- PRODUCT SPECIFIC APPLICATIONS
- LIMITATIONS
- COMPATIBILITY OF CONNECTORS
- MAKING CONNECTIONS
- INSPECTION
- INSTALLATION
- TYPICAL USAGE EXAMPLES
- WARRANTY
- MAINTENANCE & STORAGE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
019-4005
Temporary / Reusable Roof Anchor
Instruction Manual
SAFEWAZE 019-4005 Temporary Reusable Roof Anchor
WARNING
This product is part of a personal fall arrest, work positioning, suspension
or rescue system. The manufacturer’s instructions must be provided to users of
this equipment. The user must follow the manufacturer’s instructions for each
component of the system. The user must read and understand these instructions
before using this equipment. Manufacturer’s instructions must be followed for
proper use and maintenance of this equipment. Alterations to this product,
misuse of this product, or failure to follow
instructions may result in serious injury or death.
IMPORTANT
Questions regarding the use, care, or suitability of this equipment for your
application? Contact Safewaze.
IMPORTANT
Record identification information before using this product. Identification
information may be found on the equipment label. This information should be
recorded in the “Inspection Log” located at the back of this manual
OSHA 1926 Subpart M, OSHA 1910.140, ANSI Z359.18 (Type D)
This manual is intended to meet the manufacturer’s instructions as required,
and should be used as part of an employee training program as required by
OSHA.
User Information
Date of First Use:………………………….
Serial#:……………………………………….
Trainer:……………………………………….
User:……………………………………….
Do not throw away these instructions!
Read and understand these instructions before using equipment!
INTRODUCTION
Thank you for purchasing the Safewaze 019-4005 Roof Anchor. This manual must
be read and understood in its entirety, and used as part of an employee
training program as required by OSHA or any applicable state agency. This
manual and any other instructional material must be available to the user of
the equipment. The user must understand how to safely and effectively use the
019-4005 Roof Anchor, and all fall protection equipment used in conjuction
with the anchor
APPLICABLE SAFETY STANDARDS
When used according to instructions, the 019-4005 Roof Anchor meets all
applicable OSHA regulations ANSI Standards for fall protection. Applicable
standards and regulations depend on the type of work being done, and may
include state-specific regulations. Refer to local, state, and federal (OSHA)
requirements for additional information concerning the governing of
occupational safety regarding Personal Fall Arrest Systems (PFAS).
WORKER CLASSIFICATIONS
Understand the definitions of those who work in proximity of or may be exposed
to fall hazards.
Qualified Person: “Qualified” means one who, by possession of a
recognized degree, certificate, or professional standing, or who by extensive
knowledge, training, and experience, has successfully demonstrated his ability
to solve or resolve problems relating to the subject matter, the work, or the
project.
Competent Person: “Competent person” means one who is capable of
identifying existing and predictable hazards in the surroundings or working
conditions which are unsanitary, hazardous, or dangerous to employees, and who
has authorization to take prompt corrective measures to eliminate them.
Authorized Person: “Authorized person” means a person approved or
assigned by the employer to perform a specific type of duty or duties or to be
at a specific location or locations at the job site.
It is the responsibility of a Qualified or Competent person to supervise the
job site and ensure safety regulations are complied with.
PRODUCT SPECIFIC APPLICATIONS
Purpose: The Safewaze 019-4005 Roof Anchor is designed to be used as part of a Personal Fall Arrest System (PFAS).
- A competent person shall train users on this equipment in accordance with OSHA.
- Never exceed a free fall distance of 6 ft. A free fall of more than 6 ft could cause excessive arrest forces that could result in serious injury or death.
- The Safewaze 019-4005 Roof Anchor has a maximum capacity of 310 lbs including any tools, clothing, accessories, etc…, unless otherwise rated by Safewaze.
- Structures for attachment of Safewaze 019-4005 Roof Anchor shall support a minimum 5,000 lbs or be designed with a safety factor of two by a Qualified Person.
- All Safewaze anchors must IMMEDIATELY be removed from service if subjected to fall arrest forces.
- Safewaze anchors shall be inspected by the end user prior to each usage and by a Competent Person other than the user every 6 months. These inspections shall be documented.
LIMITATIONS
Fall Clearance: There must be sufficient clearance below the anchorage connector to arrest a fall before the user strikes the ground or an obstruction. When calculating fall clearance, account for a MINIMUM 2’ safety factor, deceleration distance, user height, length of lanyard/SRL, and all other applicable factors. (See Figure 1)
Swing Falls: Prior to installation or use, make considerations for
eliminating or minimizing all swing fall hazards. Swing falls occur when the
anchor is not directly above the location where a fall occurs.
Always work as close to in line with the anchor point as possible. Swing falls
significantly increase the likelihood of serious injury or death in the even
of a fall. (See Figure 2)
COMPATIBILITY OF CONNECTORS
Connectors are compatible with connecting elements when they have been
designed to work together in such a way that their sizes and shapes do not
cause their gate mechanisms to inadvertently open regardless of how they
become oriented. Connectors (hooks, carabiners, and D-rings) must be capable
of supporting at least 5,000 lbs. (22.2 kN). Connectors must be compatible
with the anchorage or other system components (see Figure 4). Do not use
equipment that is not compatible.
Non-compatible connectors may unintentionally disengage (see Figure 3).
Connectors must be compatible in size, shape, and strength. Self-locking snap
hooks and carabiners are required by ANSI Z359 and OSHA guidelines. Contact
Safewaze if you have any questions about compatibility.
NOTE: SOME SPECIALITY CONNECTORS HAVE ADDITIONAL REQUIREMENTS. CONTACT
Safewaze WITH QUESTIONS.
Using a connector that is undersized or irregular in shape (1) to connect a snap hook or carabiner could allow the connector to force open the gate of the snap hook or carabiner. When force is applied, the gate of the hook or carabiner presses against the non-compliant part (2) and forces open the gate (3). This allows the snap hook or carabiner to disengage (4) from the connection point.
MAKING CONNECTIONS
Snap hooks and carabiners used with this equipment must be double locking
and/or twist lock. Ensure all connections are compatible in size, shape and
strength. Do not use equipment that is not compatible.
Ensure all connectors are fully closed and locked.
Safewaze connectors (snap hooks and carabiners) are designed to be used only
as specified in each product’s user’s instructions. See figure 4 for examples
of inappropriate connections. Do not connect snap hooks and carabiners:
-
To a D-ring to which another connector is attached.
-
In a manner that would result in a load on the gate (with the exception of tie back hooks).
NOTE: Large snap hooks must not be connected to objects which will result in a load on the gate if the hook twists or rotates. Snap hooks marked with ANSI Z359.12 and are equipped with a 3,600 lb (16 kN) gate. Check the marking on your snap hook to verify its compatibility.
NOTE: Large throat snap hooks must not be connected to standard size D-rings or similar objects which will result in a load on the gate if the hook or D-ring twists or rotates, unless the snap hook complies with ANSI Z359.1-2007 or ANSI Z359.12 and is equipped with a 3,600 lb (16 kN) gate. Check the marking on your snap hook to verify that it is appropriate for your application. -
In a false engagement, where features that protrude from the snap hook or carabiner catch on the anchor, and without visual confirmation seems to be fully engaged to the anchor point.
-
To each other.
-
By wrapping the web lifeline around an anchor and securing to lifeline except as allowed for Tie Back models.
-
To any object which is shaped or sized in a way that the snap hook or carabiner will not close and lock, or that roll-out could occur.
-
In a manner that does not allow the connector to align properly while under load.
SPECIFIC ANCHOR APPLICATIONS
Personal Fall Arrest: The 019-4005 Roof Anchor is designed as an anchor
point to support a maximum of 1 Personal Fall Arrest System (PFAS) when
utilized for fall protection applications. The structure to which the anchor
is attached must withstand loads applied in the directions permitted by the
system of at least 5,000 lbs. Maximum allowable free fall is 6’.
019-4005 ROOF ANCHOR COMPONENTS
019-4005 Temporary Roof Anchor Components
A | Pre-Drilled Fastener Holes |
---|---|
B | Water Repellent Membrane |
C | Stabilizing Joins |
D | Energy Absoring Regions |
All above referenced applications have a worker weight capacity range of 310 lbs (including all clothing, tools, and equipment).
INSPECTION
- Safewaze Anchors shall be inspected prior to each use by the user and at least every 12 months by a Competent Person. Annual inspections shall be documented. Severity of conditions during use may necessitate increased frequency of documented inspections.
- Anchors that fail inspection MUST be removed from service.
- Prior to each use, inspect the 019-4005 Roof Anchor for deficiencies or damage, including, but not limited to, sharp edges, rough edges, deformations, corrosion, pits, burrs, chemical exposure, extreme heat exposure, or missing or illegible labels. If any deficiencies or defects are found, the 019-4005 must IMMEDIATELY be removed from service.
- The 019-4005 Roof Anchor must be inspected at least every 12 months by a Competent Person other than the user. Competent person inspections must be recorded in the inspection log included in this manual and on the inspection grid label on the 019- 4005.
- The 019-4005 Roof Anchor has two energy absorbing regions and two stabilizing joins which hold the eyelet in place during use. If these energy absorbing regions are expanded / deformed, this will indicate that the anchor has arrested a fall. Additionally, if either of the two stabilizing joins are broken, this would also indicate that the 019-4005 has arrested a fall.
- The eyelet on the 019-4005 should be straight and inline with the anchor and the fall of the roof. If the eyelet is distorted or deformed, this will indicate that the 019-4005 has arrested a fall.
- Visually inspect the water repellent membrane on the underside of the 019-4005 to ensure it is not torn, damaged, and has remained in place.
INSTALLATION
- Under guidance of a Competent or Qualified Person, a suitable anchor point must be chosen that meets the strength requirement, minimizes free fall, and reduces swing fall hazards. Do not work above the anchorage point.
- The 019-4005 Roof Anchor can be installed on any structure that meets the strength requirements as defined in the SPECIFIC ANCHOR APPLICATIONS section of this manual for Personal Fall Arrest.
- The 019-4005 Roof Anchor must be installed parallel with the roof sheets. The 019-4005 must be installed on the roofing panel aligned with the fall of the roof and centered over a roof joist. The 019-4005 can be installed on a fininshed shingled roof with no need to remove shingles. (See Figure 6)
- Secure the 019-4005 Roof anchor to the roof by installing (7) 14 Gauge x 75 mm roofing screws through the holes in the 019-4005, penetrating through the sheathing and into the roof joist. Sheathing must be a minimum of 1/2” thick and fasteners must be fully embedded. (See Figure 7)
- The 019-4005 is best suited for use on roof pitches up to 30°. For roof pitches greater than 30°, the 019-4005 should be used in conjunction with other access methods to ensure there is no live loading of the anchor. The 019-4005 are not designed for rappelling or lifting operations. Exposure of the 019-4005 to a live load could trigger the energy absorbing regions.
- The 019-4005 is suitable for use with Horizontal Lifeline Systems.
- The 019-4005 Roof Anchor can be removed and re-used unless the anchor is damaged or has experienced Fall Arrest Forces. If either of these conditions exist, the anchor must IMMEDIATELY removed from service and destroyed.
- The 019-4005 is designed as a fall arrest anchorage for a single user with a maximum weight capacity of 310 lbs. including tools and equipment. If two 019-4005 Roof Anchors are used for installation of a Horizontal Lifeline System, the system can accomodate up to two users.
- The allowable working radius of the 019-4005 Roof Anchor is 360°. The 019-4005 is Multi-Directional, and will arrest a fall from any direction relative to the anchor. (See Figure 8)
TYPICAL USAGE EXAMPLES
INSTALLATION EXAMPLE
INSTALLATION EXAMPLE
WARNING
- Users should consult with their doctor to verify ability to safely absorb the forces of a fall arrest event. Fitness level, age, and other health conditions can greatly affect an individuals ability to withstand fall arrest forces. Women who are pregnant, individuals considered minors must not use any Safewaze equipment.
- Never alter any part of an anchor or add/remove components. Safewaze shall not be held responsible for injury or death due to tampering.
- Anchors that are exposed to fall arrest forces MUST be IMMEDIATELY removed from service and destroyed.
- Failure to follow these instructions and warnings could result in serious injury or death in the event of a fall.
- A preplanned rescue procedure in the event of a fall is required. The rescue plan must be specific to the project. The rescue plan must allow for employees to rescue themselves, or to be promptly rescued by alternative means.
- Harnesses or connectors selected for use with any Safewaze anchor must be compatible in size and configuration. User must ensure compatibility of snap hooks, carabiners and other connectors. Any connection which could allow disengagement must be eliminated. Snap hooks and carabiners must be self locking and self closing and must never be hooked to each other.
- A Competent Person must conduct an analysis of the workplace and anticipate where workers will be conducting their duties, the route they will take to reach their work, and the existing and potential fall hazards they may be exposed to. The Competent Person must choose the fall protection equipment to be utilized.
- Do not misuse equipment.
- Equipment designated for fall protection must never be used to lift, hang, support or hoist tools or equipment unless specifically certified for such use.
WARRANTY
Safewaze warrants its products are free from defects in materials and construction under normal use and service. Liability is not accepted for abuse, modification, improper use, destructive activity and contaminated exposure.
MAINTENANCE & STORAGE
The 019-4005 Roof Anchor can be cleaned with water and mild soap if necessary.
User should remove all dirt, possible corrosives, and contaminants from the
anchor prior to, and after each use. Never use any type of corrosive substance
to clean the 019-4005.
Excess water should be blown out with compressed air. Hardware can be wiped
off with a clean, dry cloth.
When not in use, store the 019-4005 Permanent Roof Anchor in a cool dry area
where it will not be exposed to extreme light, extreme heat, excessive
moisture, or possibly corrosive chemicals or materials.
LABELS
Manufacture Date: XX/XX
Serial #: XXXXXXX
800-230-0319
Part# 019-4005
Temporary Roof Anchor
Min. Break Strength: 5,000 lbs
Materials: Stainless Steel
Capacity: 130-310 lbs including clothing, tools, etc.
OSHA 1926.502 OSHA 1910.66 ANSI Z359.18 (Type D)
WARNING
! THIS EQUIPMENT IS DESIGNED FOR USE AS A FALL
PROTECTION ANCHOR. USER MUST READ AND FOLLOW INSTRUCTIONS SUPPLIED WITH THIS
PRODUCT AT TIME OF SHIPMENT. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR
DEATH. AVOID CONTACT WITH HAZARDS INCLUDING BUT NOT LIMITED TO, HEAT,
CHEMICALS, ELECTRICITY, AND SHARP OR ABRASIVE EDGES AND SURFACES. MAKE ONLY
COMPATIBLE CONNECTIONS. REFER TO INSTRUCTIONS FOR APPROPRIATE INSTALLATION AND
CONNECTION METHODS. USER MUST INSPECT BEFORE EACH USE. COMPETENT PERSON MUST
INSPECT AT LEAST ONCE EVERY 12 MONTHS AND PUNCH CORRESPONDING MONTH/YEAR ON
INSPECTION GRID.
| J| F| M| A| M| J| J| A| S| O| N| D
---|---|---|---|---|---|---|---|---|---|---|---|---
| | | | | | | | | | | |
| | | | | | | | | | | |
| | | | | | | | | | | |
| | | | | | | | | | | |
| | | | | | | | | | | |
IF UNIT FAILS INSPECTION REMOVE FROM SERVICE
DO NOT REMOVE LABEL
INSPECTION LOG
Date | Inspection Items Noted | Corrective Action | Initials |
---|---|---|---|
225 Wilshire Ave SW, Concord NC, 28025
Teléfono: 800-230-0319
Fax: 704-262-9051
Correo electrónico: info@Safewaze.com
Web: Safewaze.com
References
Read User Manual Online (PDF format)