Thank you for purchasing the HYGENIQ CLEAN AIR FOGGER1.0. The powerful easy to use system can remove the dangerous particles from the air in seconds. It also makes disinfecting surfaces much more effective when combined with the approved HYGENIQ CLEAN AIR Mist. Due to the 24V Li-ion battery and refillable tank, you can keep disinfecting for as long as you wish. Please read the user manual carefully and become familiar with the operation and maintenance procedures. Store the manual in a safe place.
Packing List
Safety Instructions
The following symbols and terms are used throughout this manual and on the machine to alert the reader to safety issues and important information:
Read all instructions before using HYGENIQ CLEAN AIR FOGGER
Cautions when using the machine:
Do not operate the machine without reading and fully understanding the instructions. If the machine is operated incorrectly it can pose a danger to the operator and others and will invalidate the manufactures warranty.
Before use please read and understand the following:
- A risk assessment for the works to be undertaken;
- MSDS Chemical Data sheet;
- Risk assessment for chemical use.
Keep the HYGENIQ CLEAN AIR FOGGER upright and securely fastened at all times
while in use and during preparation and transportation.
Only use approved HYGENIQ CLEAN AIR Mist and batteries for safe use of this
machine. Using other Consumable items in the fogger invalidates the warranty
and could lead to damage of the internal parts and could possibly pose a risk
to the operator.
Maintenance/service people and operators with pacemakers need to keep a
distance from the integrated magnets in the HYGENIQ CLEAN AIR FOGGER of 6
inch/15 cm whilst maintaining and operating the fogger.
Make sure the operator has been fully trained before using the machine.
Avoid fogging directly on humans and animals.
Ensure the machine is used in a dry environment, and do not allow water or any
other liquid around the motor air inlet.
Product Description
The switch on spray handle is not a self-locking trigger button. When you press it once, the spray nozzle starts to fog. When you press it again, the fogging will stop. When the operator forgets to press the button to stop fogging. and turns off the machine with the power switch, the fogging will also stop. However, this is not recommended. Upon restarting the fogger, the default setting of the the pray nozzle is off.
Setup
-
Charging the battery
For first time charge, please remove the yellow protector from the battery. Ensure that the battery has been fully charged before each operation.
-
Fill the liquid tank
Place and secure the machine body upright. Unscrew the cap of the liquid tank,
and pour the approved HYGENIQ CLEAN AIR Mist into the tank.
Or
Take the liquid tank from the machine, and secure it in a upright position.
Unscrew the cap of the liquid tank, and pour the required amount of the
approved HYGENIQ CLEAN AIR Mist into the tank. Insert the liquid tank back to
the machine which should also be placed in an upright position. _Note: 1L
of HYGENIQ CLEAN AIR Mist _covers approximately 3650 m3.
3. Insert the battery to the machine
Open the battery housing door, and slide the fully charged battery into the battery housing, until you hear a “click” sound. Make sure the battery is installed correctly and then close the door. To remove the battery, use the clamps on the sides of the battery to release.
4. Installation of the nozzle in spray handle
Select the appropriate nozzle for the application.
Operation
-
Place the machine body with filled tank on the table, and then place the spray nozzle on the lower hook.
-
Turn the main switch to “on” before placing the fogger on your back and adjust the straps and the belt to the most optimal/comfortable operating position.
-
Spraying steps
Step 1 – Turning on the machine
Step 2 – Press the button, and start fogging
Step 3 – Turning off the machine
4. Additional information:
For larger spaces / rooms one should fog the higher part of the room. The
HYGENIQ CLEAN AIR Mist will agglomerate with the particles present where the
antimicrobial effect will do its job. Secondary effect is that the particles
get heavier and via laws of gravity descend. This way the descending layer of
mist works as a membrane filtering all other unwanted particles (such as
microdust) out. This results in a completely antibacterial filtered and
purified air composition in the room.
Specific ‘risk-points’ like door handles, light switches and other manual
touch points can be targeted directly to ensure a sanitized surface.
Maintenance
The fogger needs to be maintained during normal use:
-
Empty the liquid tank after each use, and rinse the tank and the hose with clean water;
-
Charge the battery fully after each use;
-
It is best not to exceed 4 hours of continuous use;
-
Ensure the machine is always used upright and in a dry environment, and do not allow water or any other liquid around the motor air inlet.
-
Spray nozzles need to be stored in the small tool box, together with the screw driver. The tool box can be hooked on to the backpack harness spring hook (3 nozzles in the tool box and 1 in the spray handle).
-
If there is any issue with your fogger please contact HYGENIQ.