NETOGY UPS100-PLUS MINI 50Wh DC UPS Power Bank User Manual

June 15, 2024
NETOGY

User ManualNETOGY UPS100 PLUS MINI 50Wh DC UPS Power
Bank MINI 50Wh DC UPS / POWER BANK
UPS100-PLUS
USER MANUAL

Thank you for choosing our UPS. Before operating this unit, please read the USER MANUAL carefully to ensure that the best possible performance is obtained.

Box Content

NETOGY UPS100 PLUS MINI 50Wh DC UPS Power Bank -
Content

Introduction To Display, Ports And Sockets

NETOGY UPS100 PLUS MINI 50Wh DC UPS Power Bank -
DisplayNETOGY UPS100 PLUS MINI 50Wh DC UPS
Power Bank - Display 1

Features

  • Emergency uninterruptible power supply – perfect for load shedding.
  • Can be used as a Power Bank.
  • High output power (100W) – capable of powering multiple devices simultaneously.
  • Suitable for most digital devices with 8 x DC outputs supporting multiple voltages and 2 x 5V USB ports.
  • High-capacity (14400mAh hours) Lithium Iron Phosphate (LiFePO4) battery.
  • Safeguards against power surges, spikes, dips and failure.
  • Protects voltage sensitive devices.
  • Intelligent circuit design with over-charging, over-discharging and short circuit protection.

Step-By-Step Guide To Setup Your UPS

IMPORTANT NOTES BEFORE STARTING

  • Confirm the voltage (V) of each device you want to connect to the UPS.
    Ensure that you connect each device to one of the DC Outputs on the UPS with the same voltage rating, Failure to do this may result in damage to the connected device.
    – You can check the voltage (V) of each device on its label or on the label of the device’s power supply.

  • Ensure that the Amperage (A) of the device(s) you want to connect to the UPS, does NOT exceed the Amperage (A) for the applicable DC Output(s) you will connect them to. NOTE that it does not matter ifit is lower than the indicated Amperage (A).

  • You will NOT need or require the power supply of the device(s) you want to connect to the UPS for connection/setup to the UPS — the UPS will power the connected devices.

  • ONLY connect 2 devices to the ¥-Cable if they have the same voltage rating and they are close enough to each other for the 2 ends of the Y-cable to reach both devices.

  • Ifthe connector(s) at the end of the provided cable(s) does not fit the device you want to connect to the UPS, please try one of the accessory adapters provided by connecting this adapter to the end of the provided ‘cable, and then to the device you want to connect to the UPS.
    – If the connector still does not fit, you will need to obtain or buy a cable or adapter with the correct connector type for your specific device.

IMPORTANTT: Itis the user’s responsibility to ensure that their devices are connected correctly and to the correct and appropriate outputs.
STEP 1: Connecting the power cable
Connect the one end of the provided AC/Mains Power Cable to an electrical outlet and the other end to the AC (Mains Power) Input of the UPS100-PLUS, labelled “INPUT 100-240Vac”. ![NETOGY UPS100 PLUS MINI 50Wh DC UPS Power Bank

  • Display 2](https://manuals.plus/wp-content/uploads/2023/12/NETOGY-UPS100 -PLUS-MINI-50Wh-DC-UPS-Power-Bank-Display-2.jpg)STEP 2: Connecting a device to the UPS
    Once you have confirmed the correct DC output port on the UPS to connect the device to, connect the one end of one of the provided cables to this DC output port on the UPS and the other end to the applicable device.
    Repeat this for any other device(s) you also want to connect to the UPS.
    NOTE: WHEN CONNECTING A 9-VOLT DEVICE

    • When you want to connect a 9-volt (9V) device you wil need to:
    • Ensure that the 9V/12V Selector switch is set to 9V
    • Connect the applicable device to the Yellow 9V/12V Output

STEP 3: Switching the UPS on
Switch the UPS100-PLUS on by pressing and holding the ON/OFF power button ****for 2 to 3 seconds on the UPS.NETOGY UPS100 PLUS MINI 50Wh DC UPS Power
Bank - Switchingb

Example Diagrams

NETOGY UPS100 PLUS MINI 50Wh DC UPS Power Bank - Switching
1

LED Explanation

Specififications

Battery

Battery Type| Lithium Iron Phosphate (LiFePO4)
Battery Capacity| S50Wh
Protection| BMS (overcharging, over-discharge, over-curren, over-temperature protection and battery balance)
Charge

Charging Time| 3-4hours
Physical
Unit Dimension (mm)| 253 x 146 x 45mm
Net Weight (Kg)| 07 kg
Environment
Operating Temperature| 0°-40°C
Humidity| 20% – 90%
Noise Level| Less than 40dB

  • Product specifications are subject to change without notice.
  • To ensure the safety of transportation, the battery is not fully charged ‘when leaving the factory. Please charge before use.

Troubleshooting

Issue / Error Possible Explanation/Solution
Status LED is RED This is not an error or issue.This means that the AC/Mains

power is off and the connected devices are running from the UPS battery power.
25% Battery capacity indicator LED is flashing| This indicates that the remaining battery capacity is very low (below 25%.3) and the battery power will run out soon if the AC/ Mains power is not restored.
Neither the 9V nor the I 2V LED is on| This is not an error or issue.This only means that there is no device with a load connected to theYellow 9V/I 2V Output port on the UPS. I of these 2 LEDs will light up only when a device
is connected to this port.Which LED to light up will depend on which voltage the Selector switch is set to.
Status LED is flashing YELLOW| The maximum Output power of the UPS is exceeded and the USB ports have been disabled as result.To resolve this, remove excess load by removing/disconnecting some of the connected devices.
USB Ports are not working| Confirm if the STATUS LED is flashing Yellow. If so; the maximum Output power of the UPS is exceeded and the USB ports have been disabled as a result.To resolve this, remove excess load by removing/disconnecting some of the connected devices.
All power indicator LEDs flashing| The maximum Output power of the UPS is exceeded and the disabling the USB ports did not resolve/reduce the load enough. To resolve this, remove excess load by removing/disconnecting some of the connected devices.

IMPORTANT
The total power of the loads which connect to all the ports cannot exceed the maximum output power of your model. If this does occur, the USB ports will be exceeds the maximum power rating after the USB ports are disabled, then all situation, please remove excess load.
If the UPS will not be used for extended periods, ensure that it is fully charged before storing in a cool, dry place. If the UPS has been in storage too long, you will need to plug in mains power until the status light turns green. It is recommended that the UPS battery is charged once per month.
WARNING

  1. Always check the working voltage, current and polarity of the loads before connecting them to the UPS, connecting them to the appropriate voltage output.
  2. Charge device fully prior to initial use.
  3. Damage caused by dropping, disassembling or attempting to repair the UPS privately will render your warranty null and void.
  4. Do not immerse the UPS in water or allow it to get wet.
  5. Do not dispose of any of the UPS’s components in a fire.
  6. Do not use the UPS in a flammable environment.
  7. Keep the UPS out of reach of children and unauthorised persons.

Device Support Information
Device Support: +27 (0) 10 824 0049
Operating Hours: 08:00 – 17:00 (Mon – Thurs)
08:00 – 16:00 (Fri)
www.netogy.co.za
Copyright © Nology (Pty) Ltd | E&OE

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals