HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater Installation Guide

June 15, 2024
HEATFAST

HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater -
logo

GAS-FIRED
INFRA-RED TANK TOP HEATER

HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater

MODEL: HF15TT / HF30TT
CYLINDER NOT INCLUDED

HF30TT Gas Fired Infra Red Tank Top Heater

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

  • Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance.
  • An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

  • Do not try to light appliance.
  • Extinguish any open flame.
  • Shut off gas to appliance.

Service must be performed by a qualified service agency.

READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.

This is an unvented gas-fired portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided.

CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov

United States Stove Company
227 Industrial Park Road, South Pittsburg, TN
PH: 800-750-2723
www.usstove.com

GENERAL SAFETY INFORMATION

WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.

GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.

WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE.

WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.

WARNING:
THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING
COMBUSTION BY-PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM).
THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.

The heater is designed and approved for us as, a construction heater and in accordance with ANSI Z83.7-2017 CSA 2.14-201.
Check with your local fire safety authority if you have any questions about applications.
Other standards govern the use of fuel gases and heat-producing products and specific applications. Your local authority can advise you about these standards.

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

USA 8-Hr Time weighted average (OSHA 29 CFR 1926.55 App A)

CO 50 ppm
CO2 5000 pm
NO2

USA – Ceiling Limit (Short Term Exposure Limit = 15 minutes)

CO|
---|---
CO2|
NO2| 5 ppm

Canada 8-hr time weighted average WorkSafe BC OHS Guidelines Part 5.1 and Ontario Work¬places Reg 833

CO 50 ppm
CO2 5000 pm
NO2 3 ppm (Reg 833)

Canada STEL (15 minutes Reg 833/1 hour WSBC) WorkSafe BC OHS Guidelines Part 5.1 and Ontario Workplaces Reg 833

CO 100 ppm
CO2 15,000 pm (WSCB)

30,000 ppm (Reg 833)
NO2| 1.0 ppm (WorkSafeBC)
5.0 ppm (Reg 833)

Note: Installation of this appliance at altitudes above 2000 ft (610 m) shall be in accordance with local codes, or in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or National Standard of Canada, Natural Gas and Propane  Installation Code, CSA B149.1.

PORTABLE HEATER FEATURES

HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater - PORTABLE HEATER
FEATURES

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

ASSEMBLY AND HOOK-UP INFORMATION

  • Propane cylinders (tanks) are not included with these heaters.
  • Remove the heater from the carton.
  • Use only vapor withdrawal LP gas cylinders constructed for use with propane only (HD-5) and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation (DOT SPEC. 39).
  • This heater must be used only with a vapor withdrawal LP gas bulk tank equipped with a standard POL valve – Do Not use this heater on bulk tanks greater than 20 pounds LPG capacity (50 pounds water capacity).

DUAL BURNER MODEL

  1. Use a phillips head screw-driver to remove the two screws located in the collar bracket. Set aside for later use.

  2. Place the collar bracket onto the tank with the tank collar bracket over the tank collar. Mounting bolt knob should be positioned to the outside of the tank collar. Firmly secure the collar bracket to the tank by hand-tightening the mounting bolt knob. Do not  overtighten.
    HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater - the collar
bracket WARNING: Never leave the heater unattended while operating.
    Disconnect the heater from its power source when not in use.

  3. Align the bolt holes in the tank collar bracket with the bolt holes located in the center plate of the manifold. Using the previously removed screws, secure the center plate manifold to the collar bracket. NOTE: The heater MUST be facing away from the tank  once it has been attached to the collar bracket. Make sure that tip switch bracket is between the tank collar bracket and the manifold center plate.
    HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater - bolt
holes

  4. Make sure heater regulator is in the “OFF” position. Insert regulator’s connector into tank’s valve and turn left (counter clockwise) with hand as much as possible.
    Do not overtighten.
    HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater - e heater
regulator

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

SINGLE BURNER MODEL

  1. Be sure the heater is facing away from tank. Insert the regulator connector into the tank valve outlet fitting and turn left (counter clock-wise) until fully tightened. Do not overtighten.
    HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater - SINGLE BURNER
MODEL

  2. Loosen the wingnut located on the venturi tube. Place the heater support around venturi and rest the bottom of the heater support on the propane cylinder. Tighten the previously loosened wingnut to secure the heater support onto venturi tube.
    HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater - venturi
tube

  3. Operate only on a stable, level surface.

  4. Open propane tank valve slowly.

  5. Check all fittings for leaks. Apply a 50/50 mixture of liquid soap and water to all joints. Bubbles forming indicate a leaking connection. Correct all leaks before proceeding.
    WARNING: NEVER TOUCH HEATER WHILE IN OPERATION TO AVOID INJURY. MOVE HEATER BY GRASPING THE PROPANE CYLINDER CAREFULLY.

  6. The heater should be inspected before each use and at least annually by a qualified service person.

  7. The hose assembly shall be visually inspected prior to use of heater. If it is evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation. Replacement hose assembly shall be hose assembly as  listed in the parts list.

  8. Minimum inlet gas pressure is 20 psi.

  9. Maximum inlet gas pressure is 120 psi (equivalent to an ambient temperature of 75°F (24°C)).

IMPORTANT INFORMATION

ODOR FADE WARNING

WARNING
ASPHYXIATION HAZARD

  • DO NOT USE THIS HEATER FOR HEATING HUMAN LIVING QUARTERS.
  • DO NOT USE IN UNVENTILATED AREAS.
  • THE FLOW OF COMBUSTION AND VENTILATION AIR MUST NOT BE OBSTRUCTED.
  • PROPER VENTILATION AIR MUST BE PROVIDED TO SUPPORT THE COMBUSTION AIR REQUIREMENTS OF THE HEATER BEING USED.
  • REFER TO THE SPECIFICATION SECTION OF THE HEATER’S MANUAL, HEATER DATA PLATE, OR CONTACT THE FACTORY TO DETERMINE COMBUSTION AIR VENTILATION REQUIREMENTS OF THE HEATER.
  • LACK OF PROPER VENTILATION AIR WILL LEAD TO IMPROPER COMBUSTION.
  • IMPROPER COMBUSTION CAN LEAD TO CARBON MONOXIDE POISONING LEADING TO SERIOUS INJURY OR DEATH. SYMPTOM OF CARBON MONOXIDE POISONING CAN INCLUDE HEADACHES DIZZINESS AND DIFFICULTY IN  BREATHING.

FUEL GAS ODOR
LP gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks. If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor. ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!

  • Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.
  • Get everyone out of the building and away from the area immediately.
  • Close all propane (LP) gas tank or cylinder fuel supply valves, or the main fuel supply valve located at the meter if you use natural gas.
  • Propane (LP) gas is heavier than air and may settle in low areas. When you have reason to suspect a propane leak, keep out of all low areas.
  • Use your neighbor’s phone and call your fuel gas supplier and your fire department. Do not re-enter the building or area.
  • Stay out of the building and away from the area until declared safe by the firefighters and your fuel gas supplier.
  • FINALLY, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance  for you.

ODOR FADING – NO ODOR DETECTED

  • Some people cannot smell well. Some people cannot smell the odor of the man-made chemical added to propane (LP) or natural gas. You must determine if you can smell the odorant in these fuel gases.
  • Learn to recognize the odor of propane (LP) gas and natural gas. Local propane (LP) gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor.
  • Smoking can decrease your ability to smell. Being around an odor for a period of time can affect your sensitivity to that particular odor. Odors present in animal confinement buildings can mask fuel gas odor.
  • The odorant in propane (LP) gas and natural gas is colorless and the intensity of its odor can fade under some circumstances.
  • If there is an underground leak, the movement of gas through the soil can filter the odorant.
  • Propane (LP) gas odor may differ in intensity at different levels. Since Propane (LP) gas is heavier than air, there may be more odor at lower levels.

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

  • Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously.

ATTENTION – CRITICAL POINTS TO REMEMBER

  • Propane (LP) gas has a distinctive odor. Learn to recognize these odors. (Reference Fuel Gas Odor and Odor Fading sections to the left and above).
  • Even if you are not property trained in the service and repair of the heater, ALWAYS be consciously aware of the odors of propane (LP) gas and natural gas.
  • If you have not been properly trained in repair and service of propane (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system.
  • A periodic sniff test around the heater or at the heater’s joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT!

GENERAL INFORMATION
A. These units are high pressure propane appliances and are designed to be connected to a bulk propane tank.
B. These heaters are equipped with an automatic Safety Shutoff Valve. The gas flow will automatically stop if the heater fails to operate for any reason.
C. Maximum safety and convenience have been built into the Hi-Med-Lo-Off Control Valve/Regulator. The following table lists the approximate BTU’s consumed and the operating hours you can reasonably expect from bulk propane cylinders.
D. These heaters are for temporary heating of buildings under construction, alterations, or repair.

Model HF15TT HF30TT
Valve Position BTU Input BTU Input
Hi 15,000 30,000
Med 12,000 24,000
Lo 10,000 10,000

FOR SAFE OPERATION
A. READ INSTRUCTIONS CAREFULLY: Read and adhere to these instructions. Do not allow anyone who has not read the instructions to assemble, light, adjust or operate the heater.
WARNING: KEEP THE HEATER OUT OF THE REACH OF CHILDREN
B. Use only in accordance with local codes or, in the absence of local codes, with the standard for the Storage and handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B 149.1, Natural Gas and Propane Installation Code.
C. PROPANE IS VERY FLAMMABLE: In the event of a leak, propane will accumulate and the possibility of a fire is present.
Propane gas is scented and its strong odor is readily detectable. Never strike a match or bring any flame or create an electric spark in an enclosure when you smell propane gas. Ventilate the area thoroughly, move the heater outside, find and correct the source of  the leak before attempting to light any appliance. If you are unsure of these instructions evacuate immediately and call for help.
D. GAS LEAKAGE: If the leak cannot be corrected do not tamper with the heater, follow the shut down instructions and return the heater to the dealer or address given on last page.

WARNING: DO NOT USE THIS HEATER ON BULK TANKS OF GREATER CAPACITY THAN 20 POUNDS LPG (50 POUNDS WATER CAPACITY).

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

E. LEAK DETECTION: Before each use of the heater check all fittings and connections with a soap solution to be sure there are no leaks. NEVER USE ANY FLAME FOR LEAK TEST.
F. CONNECTING HEATER TO PROPANE CYLINDER: Always connect the heater to the bulk cylinder in the outdoors or in a well ventilated area. NEVER connect this heater to a cylinder near an open flame.
G. USE OF HEATER: Always operate the heater with the propane cylinder in an upright position on a level noncombustible surface. NEVER place the cylinder on its side when operating the heater.
H. ATTEND HEATER: Do not leave heater unattended while it is in operation.
I. ALWAYS LIGHT HEATER WITH MATCH OR “SPARKLITE” IGNITER: NEVER attempt to light the heater with a spark lighter.
J. DO NOT TAMPER: Should the heater not perform properly, such as little or no heat when operating in the “Hi” position, or for any other reason, DO NOT ATTEMPT TO REPAIR OR TAMPER with the heater. Any tampering could make the use of the heater  unsafe and dangerous. Return the heater to the dealer or the address given on last page for repair or replacement.
K. FOR STORAGE: The heater Hi-Med-Lo-Off regulating valve should always be turned to “off” when the heater is not in use.
Allow at least 15 minutes for cooling before handling and storing. Detach propane cylinder from heater before storing. DO NOT store propane cylinders indoors or near open flame or heat.
L. DO NOT TRANSPORT OR MOVE APPLIANCE WHILE IN OPERATION. FOLLOW SHUTDOWN AND STORAGE INSTRUCTIONS TO TRANSPORT OR MOVE THIS APPLIANCE.

VENTILATION
A. WARNING: This heater is an unvented appliance and MUST be used ONLY in a well ventilated area. NEVER attempt to operate the heater inside any vehicle, camper or enclosure.
B. FOR NON-RESIDENTIAL INDOOR AND OUTDOOR USE. Any combustion process requires and consumes oxygen, and will produce carbon monoxide. THIS HEATER MUST BE USED WITH ADEQUATE VENTILATION. Do not use inside a house, camper,  tent or any type of unvented or a tightly enclosed area.
C. WARNING: Provide ample ventilation. This heater consumes air (oxygen). Do not use this heater in unventilated structures to avoid endangering your life. Provide additional ventilation for any additional fuel-burning appliances and additional occupants.
D. Flow of combustion and ventilation air must not be obstructed.

MINIMUM CLEARANCE FROM COMBUSTIBLE MATERIALS
A. When operating, the heater surfaces are extremely hot. Keep sleeping bags, clothing, and all combustible materials clear of the heater by at least the distances shown.

BTU/HR. Rating Normal Operating Procedure Clearances to Combustibles
Model Gas Propane From C.L.

OF HTR. TO
FLOOR| FRONT| SIDES| REAR| CEILING
HF15TT| 15,000| Vertical| 24″| 30″| 30″| 30″| 30″
HF3OTT| 30,000| Vertical| 24″| 30″| 30″| 30″| 36″

B. WARNING: To avoid injury or property damage never allow clothing, tents or other combustible materials within 30” of the face of the heater. This heater must be located at least 24” above the floor level when in use. Never operate the heater when sleeping.
C. WARNING: Never direct the heat output of this heater toward any propane tank within 20 feet.

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

OPERATION

LIGHTING INSTRUCTIONS
Before attempting to light the heater, check all fittings and connections with a soap solution. NEVER USE A MATCH TO FOR LEAKS. Should a gas leak occur, do not attempt to repair or use heater. Return the heater to your dealer or the addron back page.
Fuel – This heater must be used only with a vapor withdrawal LP gas bulk cylinder. THE BULK TANK MUST BE EQUIPPEA STANDARD POL VALVE.

WARNING: USE HD.5 PROPANE GAS ONLY. DO NOT USE ANY OTHER TYPE FUEL. SEE YOUR PROPANE DEALER IF YOU HAVE ANY QUESTIONS REGARDING FUEL.

  1. Turn the heater’s “Hi-Med-Lo-Off” regulator knob to “Hi” (counterclockwise). Stand to the side of the unit while lighting. Do not stand or have any part of the body over or in front of the heater while lighting.

  2. Place a lit match inside the hole located on the left-hand side of the rear reflector.
    HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater -
reflector

  3. Depress and hold the valve button located on the safety shutoff valve. After the heater is lit, continue to hold the valve button in for 30 seconds, then release the button slowly. CAUTION: DO NOT PUSH IN VALVE BUTTON BEFORE INSERTING THE LIT  MATCH. NEVER STAND IN FRONT OF THE HEATER WHILE LIGHTING.
    HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater - WHILE
LIGHTING

  4. If burner does not light within 30 seconds, turn the heater’s regulator knob to “Off” (clockwise) and allow at least five minutes for gas to dissipate before attempting to relight.

  5. NOTE: Should the orifice become clogged as indicated by low volume of gas when operating on “Hi” with a full cylinder, or should the heater fail to operate properly for any reason, return the heater to the dealer or the address given in this manual for  repair or replacement. DO NOT ATTEMPT TO REPAIR OR TAMPER WITH HEATER.

  6. Adjust heat output by turning knob to desired position.

DO NOT USE THIS HEATER FOR COOKING.

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

SHUTDOWN AND STORAGE INSTRUCTIONS
A. The bulk propane tank “ON-OFF” valve should ALWAYS be completely turned “OFF” when the heater is not in use.
B. When shutting off the heater, turn the regulator knob on the heater to “OFF” (clockwise).
C. CAUTION: After turning unit off, heater will remain extremely hot. Allow at least 15 minutes for cooling before handling and storing. Detach heater from bulk tank before handling and storage. REMEMBER – POL fitting is a left-hand thread.
D. HEATER STORAGE: Indoor storage of the heater is permissible only if the cylinder is disconnected and removed from the heater. Cylinders must be stored outdoors out of the reach of children and must not be stored in a building, garage or any other  enclosed area. Store cylinders only in accordance with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Petroleum Installation Code.
E. See the “Parts List” section of this manual.

MAINTENANCE

A. Remove thermocouple retaining bracket screw from back of burner assembly. Remove bracket.
B. Note position of thermocouple in retaining tabs on the back of the Burner assembly. Remove the thermocouple.
C. Remove wing bolt and fiber washer that attached the safety shut-off to the burner Assembly.
D. Slide the safety shut-off from burner assembly.
E. Remove burner orifice from the safety shut-off.
F. Clean burner orifice with compressed air (80 psi max).
G. Direct compressed are through the burner venturi tube toward the burner plenum so that dust collected on the grid screen will be blown outward. Keep face away from the grid screen.
H. Reassemble heater in reverse order of disassembly.

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

HF15TT PARTS LIST

HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater - PARTS
LIST

Key Part # Description Qty
1 81383 Control Valve Assembly 1
2 894002 Burner Head Assy 1
3 894003 Front Guard Assy 1
4 894004 Rear Guard Assy 1
5 80918 Tip Switch 1
6 80919 Thermocouple/Tip Switch Wire Assy. 1
7 831041 Wing Bolt w Fiber Washer 1
8 894005 Support Leg 1

IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY
COMPONENTS WILL VOID THE WARRANTY.

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

HF30TT PARTS LIST

HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater - HF30TT PARTS
LIST

Key Part # Description Qty
1 81384 Control Valve Assembly 1
2 894002 Burner Head Assy 2
3 894003 Front Guard Assy 2
4 894004 Rear Guard Assy 2
5 80918 Tip Switch 2
6 80919 Thermocouple/Tip Switch Wire Assy 2
7 831041 Wing Bolt w Fiber Washer 2
8 894006 Tank Collar Bracket 1

IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY  COMPONENTS WILL VOID THE WARRANTY.

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

SERVICE RECORD

It is recommended that this unit is serviced regularly and that the appropriate Service Interval Record is completed.
Service Provider:
Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer’s specified spare part when replacement is necessary.

HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater - Service
Record

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

LIMITED WARRANTY

United States Stove Company warrants this product, to the original retail purchaser only, to be free from defects in material and workmanship for a period of one (1) year from the date of the initial purchase as evidenced on an invoice, canceled check, sales receipt, etc. In the event of a defect, this Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service within the limited warranty period, and which United States Stove Company deems at its  reasonable discretion. THE LIMITED WARRANTY SET FORTH HEREIN IS THE SOLE WARRANTY PROVIDED TO PURCHASER AND IS IN LIEU OF ALL OTHER WARRANTIES AND REPRESENTATIONS, EXPRESS OR IMPLIED. UNITED STATES  STOVE COMPANY MAKES NO REPRESENTATIONS OR WARRANTIES WHATSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCT, OTHER THAN (i) THE LIMITED WARRANTY ABOVE, AND (ii) ANY IMPLIED WARRANTIES  IMPOSED BY APPLICABLE LAW WHICH CANNOT BE WAIVED OR DISCLAIMED UNDER APPLICABLE LAW. ALL OTHER WARRANTIES OF ANY KIND, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY AND  FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED AND EXCLUDED TO THE FULLEST EXTENT NOT PROHIBITED BY APPLICABLE LAW. This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she resides. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or state law may affect the duration of limitations, so the above exclusion and limitations may not be applicable.

OTHER LIMITATIONS: United States Stove Company disclaims all other warranties for products that are purchased from sellers other than authorized retailers or distributors. This product must be properly installed, maintained and operated in accordance  with the instructions provided herein. Furthermore, United States Stove Company requires reasonable proof of the date of purchase from an authorized retailer or distributor.
This Limited Warranty does not cover any operational failures or difficulties due to normal use and wear and tear, accident, abuse, misuse, alteration, misapplication, improper installation or improper maintenance or service by you or any third party. Failure to  perform normal and routine maintenance on the product, shipping damage, damage related to animals, and damage due to weather are not covered under this Limited Warranty. In addition, this Limited Warranty does not cover damage to the finish on the  product, such as scratches, dents, discoloration, rust or other weather damage. This warranty does not apply to products purchased for rental use. United States Stove Company assumes no responsibility for any defects caused by third parties. United States  tove  Company does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its products, and no such representations are binding on United States Stove  Company.

CLAIM PROCEDURE: All transportation costs for the return of the damaged product or parts will be the responsibility of the purchaser. Upon receipt of the product, United States Stove Company will examine it and determine if the product contains a defect.  United States Stove Company will repair or replace and return the item, freight pre-paid. If United States Stove Company finds the item to be in normal operating condition, or not defective, the item will be returned freight collect. Purchaser shall specify the  model number(s) and serial number(s) of any product(s) when making any claims with United States Stove Company. Please use the following to identify your product:

Model #: ____
Serial #: _____

WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.

NOTES

HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater -
logo

Documents / Resources

| HEATFAST HF30TT Gas Fired Infra Red Tank Top Heater [pdf] Installation Guide
HF15TT, HF30TT, HF30TT Gas Fired Infra Red Tank Top Heater, HF30TT, Gas Fired Infra Red Tank Top Heater, Infra Red Tank Top Heater, Tank Top Heater, Top Heater, Heater
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals