Rinnai 951WPB Weather Proof Box
Product Information
Specifications
- Compatible Models : RHFE-951ETR, RHFE-952ER, RHFE-1250ETR, RHFE-1252ER, RHFE-1253ETR
- Weather Proof Box Models : 951WPB, 1250WPB
- Suitable with Direct Flue Configuration only
- Kit Contents 951WPB:
- Assembly & Installation Screws: 8×10 Philips (PH), Self Drilling (SD), Wood (W)
- Weather Proof Box : 7 components
- Support Shelf: 3 components
- Instruction Manual
- Kit Contents 1250WPB
- Assembly & Installation Screws: 8×10 Philips (PH), Self Drilling (SD), Wood (W)
- Weather Proof Box : 7 components
- Support Shelf: 3 components
- Instruction Manual
Product Usage Instructions
Box Assembly
- Ensure that the correct method of assembly is followed, as this provides the main weather sealing for the box assembly.
- Secure side panels B and C to the inside of the flanges of the back panel A (for both models PH screws x10)
- Secure base panel D to the inside of the flanges of panels A, B & C (for 951WPB PH screws x16 / for 1250WPB PH screws x18).
- Secure top panel E over the top and to the outside of panels A, B & C (for 951WPB PH screws x16 / for 1250WPB PH screws x18).
Framing & Cavity Requirements
Interior Wall View
Note that only the framing is shown. a
Exterior Wall View a
Framing & Interior Wall
- b = 570mm ~ 580mm c = 570mm ~ 600mm d = Equal Height e = 510mm
Exterior Wall
951WPB a = 965mm ~ 980mm
1250WPB a = 1265mm ~ 1280mm
FAQ
-
Q: Can I use the Weather Proof Box with any flue configuration?
A: No, the Weather Proof Box is suitable with Direct Flue Configuration only. -
Q: What are the kit contents for the 951WPB and 1250WPB models?
A: The kit contents for the 951WPB include assembly & installation screws, weather proof box components, support shelf components, and an instruction manual. The kit contents for the 1250WPB are the same.
Weather Proof Box – 951WPB / 1250WPB
Installation Manual
Compatible Models | 951WPB | 1250 WPB |
---|---|---|
RHFE-951ETR | ● | – |
RHFE-952ER | ● | – |
RHFE-1250ETR | – | ● |
RHFE-1252ER | – | ● |
RHFE-1253ETR | – | ● |
This accessory shall be installed in accordance with
IMPORTANT
- Manufacturer’s Installation Instructions, including OPERATION & INSTALLATION MANUAL, Power Flued Flamefire Gas Space Heater RHFE-951ETR / RHFE-952ER / RHFE-1250ETR / RHFE-1252ER / RHFE-1253ETR (supplied with the heater) and INSTALLATION MANUAL, Power Flued Flamefire Space Heater Co-axial Flue System (supplied with the flue)
- Current AS/NZS 5601 AS/NZS 3000
- Local Regulations and Municipal Building Codes including local OH&S requirements To be installed, maintained and removed by an Authorised Person.
For continued safety of this appliance it must be installed and maintained in accordance with the manufacturers instructions.
IMPORTANT
This Weather Proof Box is suitable with Direct Flue Configuration only, Part
No. ASPDFK. Use only genuine Rinnai Parts.
NOTE
The 951WPB and RHFE-951ETR have been illustrated throughout this instruction.
The installation and assembly methods are identical for all models except
where it has been otherwise stated.
Kit contents 951WPB | Kit contents 1250WPB |
---|---|
Item | Quantity |
Assembly & Installation Screws:
- 8×10 Philips (PH)
- Self Drilling (SD)
- Wood (W)
- Weather Proof Box (7 components)
- Support Shelf (3 components)
- Instruction Manual
| 57
7
12
1
1
1
| Assembly & Installation Screws:
- 8×10 Philips (PH)
- Self Drilling (SD)
- Wood (W)
- Weather Proof Box (7 components)
- Support Shelf (3 components)
- Instruction Manual
| 61
7
12
1
1
1
Rinnai Australia Pty Ltd
- ABN 74 005 138 769 AU45204
- 100 Atlantic Drive, Keysborough, Victoria 3173
- P.O. Box 460, Braeside, Victoria 3195
- Tel : (03) 9271 6625
- Fax : (03) 9271 6622
National Help Line
-
Tel: 1300 555 545
-
Fax: 1300 555 655*
-
Hot Water Service Line
-
Tel: 1800 000 340
-
Cost of a local call may be higher from a mobile phone.
(National calls from public phones in Australia are free.) -
For further information visit www.rinnai.com.au or email enquiry@rinnai.com.au
-
With our policy of continuous improvement, we reserve the right to change, or discontinue at any time, specifications or designs without notice.
INSTALLATION MANUAL – 951WPB / 1250WPB
BOX ASSEMBLY IMPORTANT
Ensure that the correct method of assembly is followed, as this provides the
main weather sealing for the box assembly.
- Secure side panels B and C to the inside of the flanges of the back panel A (for both models PH screws x10).
- Secure base panel D to the inside of the flanges of panels A, B & C (for 951WPB PH screws x16 / for 1250WPB PH screws x18).
- Secure top panel E over the top and to the outside of panels A, B & C (for 951WPB PH screws x16 / for 1250WPB PH screws x18).
FRAMING & CAVITY REQUIREMENTS
IMPORTANT
Prepare framing and cavity in accordance with all Local Regulations and Municipal Building Codes including local OH&S requirements. The joists used to support the appliance off the ground MUST be capable of supporting a minimum of 105kg.
- The box is NOT designed to support brick work or any other part of the dwelling or structure.
- The flue terminal clearances are to be in accordance with Current AS/NZS 5601.
HEATER SUPPORT SHELF ASSEMBLY INSTALLATION
Fit side shelf bracket F to the bottom left corner of the framing so that the return folds are flush with the interior wall, secure in place (W screws x5). Repeat for side shelf bracket G in the opposite corner. Fit the L shaped cross brace H over the rear of side self brackets, with the tab facing downwards and secure to make rigid (PH screws x4).
HEATER INSTALLATION
Mount and secure the appliance and connect the flue system in accordance with the OPERATION & INSTALLATION MANUAL, Power Flued Flamefire Gas Space Heater RHFE-951ETR / RHFE-952ER / RHFE-1250ETR / RHFE-1252ER (supplied with the heater) and the INSTALLATION MANUAL, Power Flued Flamefire Space Heater Co- Axial Flue System (supplied with the flue).
BOX INSTALLATION
Secure the box assembly to the exterior wall (with appropriate fixings), ensuring that it is both level and symmetrically aligned with the cavity / penetration, the heater support shelf and the appliance.
IMPORTANT
It is the installers responsibility to ensure that the box is appropriately
attached and weather sealed to the exterior wall in accordance with all Local
Regulations and Municipal Building Codes including local OH&S requirements.
GAS SUPPLY
As the finished depth of the weatherproof box will vary depending on the wall
thickness, the gas supply might not be able to enter through the bottom of the
box. Use the diagram below to assist in determining this.
Dimension | 952 | 1252/1253 |
---|---|---|
A (from centreline) | 420 | 570 |
B | 65 | |
C | 125 | |
D | 530 Min | |
E | 120 Min |
AIR HOSE ACCESS PLATE INSTALLATION
Secure the side (air hose) access panel I to the box (PH screws x9).
FLUE ACCESS PLATE INSTALLATION
With the screw hole (iv) uppermost, secure the flue terminal wall plate K (supplied with the flue terminal) to the rear (flue) access panel J (SD screws x3), then with the same orientation fit this assembly over the flue pipe and secure it to the box (SD screws x4).
FLUE PREPARATION & TERMINAL INSTALLATION
Prepare flue pipe and install flue terminal components in accordance with INSTALLATION MANUAL, Power Flued Flamefire Space Heater Co-Axial Flue System (supplied with the flue).
NOTE
- The screws for mounting the flue terminal components are supplied with the flue.
- The flue terminal clearances are to be in accordance with Current AS/NZS 5601.
References