IRM-20 Series 20W AC-DC PCB Mount Green Power Module Instructions

June 15, 2024
Green Power

IRM-20 Series 20W AC-DC PCB Mount Green Power Module

Features

  • 2.06″x1.07″ compact size
  • Universal input 85~305VAC
  • No load power consumption<0.1 W
  • EMI Class B without additional components
  • Wide operating temp. range -30~70°C
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Isolation Class II
  • Pass LPS
  • 3 years warranty

Applications

  • Industrial electrical equipment
  • Mechanical equipment
  • Factory automation equipment
  • Hand-held electronic device

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

IRM-20 is a 20W miniature (52.427.224mm) AC-DC module-type power supply, ready to be soldered onto the PCB boards of various kinds of electronic instruments or industrial automation equipment. This product allows the universal input voltage range of 85~305VAC. The 94V-0 flame retardant plastic case potted with silicone enhances heat dissipation and meets the anti- vibration demand up to 2G; moreover, it provides fundamental resistance to dust and moisture. With a high efficiency up to 85% and extremely low no-load power consumption below 0.1W, the IRM-20 series fulfils the worldwide regulation for the low power consumption requirement for electronics. The entire series is a Class Il design (no FG pin), incorporating the built-in EMI filtering components, enabling compliance with BS EN/EN55032 Class B; the supreme EMC features to keep the end electronic units from electromagnetic interference.

Model Encoding

SPECIFICATION

MODEL| IRM-20-3.3| IRM-20-5| IRM-20-12| IRM-20-15| IRM-20-24
---|---|---|---|---|---







OUTPUT

| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V
RATED CURRENT| 4.5A| 4A| 1.8A| 1.4A| 0.9A
CURRENT RANGE| 0 ~ 4.5A| 0 ~ 4A| 0 ~ 1.8A| 0 ~ 1.4A| 0 ~ 0.9A
RATED POWER| 14.85W| 20W| 21.6W| 21W| 21.6W
RIPPLE & NOISE (max.) Note.2| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.5%| ±2.5%| ±2.5%| ±2.5%
LINE REGULATION| ±0.5%| ±0.5%| ±0.3%| ±0.3%| ±0.3%
LOAD REGULATION| ±1%| ±1%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 20ms/230VAC          1000ms, 20ms/115VAC at full load
HOLD UP TIME (Typ.)| 40ms/230VAC          8ms/115VAC at full load




INPUT

| VOLTAGE RANGE| 85 ~ 305VAC          120 ~ 430VDC
FREQUENCY RANGE| 47 ~ 440Hz
EFFICIENCY (Typ.)| 76%| 79%| 84%| 84%| 85%
AC CURRENT (Typ.)| 0.6A/115VAC          0.4A/230VAC 0.3A/277VAC
INRUSH CURRENT (Typ.)| COLD START 20A/115VAC          40A/230VAC
LEAKAGE CURRENT| < 0.25mA/277VAC



PROTECTION

| ****

OVERLOAD

| 115%~160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed


OVER VOLTAGE

| 3.8 ~ 4.46V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~ 20.25V| 27.6 ~ 32.4V
Protection type : Shut off o/p voltage, clamping by zener diode





ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SOLDERING TEMPERATURE| Wave soldering: 265℃,5s (max.); Manual soldering: 390℃,3s (max.)
OPERATING ALTITUDE Note.4| 2000 meters





SAFETY &

EMC

(Note.5)

| SAFETY STANDARDS| IEC62368-1, UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI CNS14336-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH




EMC EMISSION

| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032(CISPR32), CNS13438| Class B
Radiated| BS EN/EN55032(CISPR32), CNS13438| Class B
Harmonic Current (Note 5)| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| ——-







EMC IMMUNITY

| BS EN/EN55035, BS EN/EN61000-6-2
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated Susceptibility| BS EN/EN61000-4-3| Level 3, Criteria A
EFT/Burest| BS EN/EN61000-4-4| Level 3, Criteria A
Surge| BS EN/EN61000-4-5| Level 4,2KV/L-N, criteria A
Conducted| BS EN/EN61000-4-6| Level 3, Criteria A
Magnetic Field| BS EN/EN61000-4-8| Level 4, Criteria A
Voltage Dips and interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods


OTHERS

| MTBF| 10656.2K hrs min.      Telcordia SR-332 (Bellcore) ; 970.3K hrs min.      MIL-HDBK-217F (25℃)
DIMENSION| 52.427.224mm (LWH)
PACKING| 0.05Kg/240pcs/13Kg/0.94CUFT
NOTE| 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3.  Tolerance :includes set up tolerance, line regulation and load regulation.

4.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).

5.  The power supply is considered as an independent unit,but the final equipment still needs to confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on http://www.meanwell.com)

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

IRM-20-Series-20W-AC-DC-PCB-Mount-Green-Power-Module-
fig-2

Derating Curve

IRM-20-Series-20W-AC-DC-PCB-Mount-Green-Power-Module-
fig-3

Output Derating VS Input Voltage

Mechanical Specification

IRM-20-Series-20W-AC-DC-PCB-Mount-Green-Power-Module-
fig-6

Installation Manual