PROJOY electric PEFS-24V-CN Series Panel Level Rapid Shutdown Control Box Installation Guide
- June 4, 2024
- PROJOY electric
Table of Contents
PEFS-24V-CN Series Panel Level Rapid Shutdown Control Box
Installation Guide
Scope and General
The manual only used to PEFS-24V-CN Series Panel-level Rapid Shutdown(DC 24V) Control Box.
Version | Date | Remark | Chapter |
---|---|---|---|
V1.0 | 2021-10-15 | First Edition | – |
V2.0 | 2022-04-20 | Content Modified | 4 Installation & Connection/ |
5 Technical Specification
V3.0| 2022-06-02| Content Modified| 3 Introduction
4 Installation & Connection/
5 Technical Specification
Important Safety Precautions
2.1 Disclaimer:
PROJOY assumes no responsibility for any loss, in particular for circuit
damage, resulting from any violation of the specifications recommended and
referred to in this specification. PROJOY assumes no responsibility for the
damage of the product caused by the maintenance, improper use, wrong
installatio,n or wrong system design of the product by non-designated
personnel.
2.2 Safety instructions:
- PEFS is an electrical product that should be installed by a suitable person who meets local regulations.
- When modifying an existing installation, isolate the inverter from the PV array by turning OFF the DC isolator/switch disconnect or turning OFF the inverter and the AC switch.
- Incorrect connections to the PEFS-24V-CN may cause failure.
2.3 Cautions:
If the inverter and PV module connectors are not compatible with PEFS
connectors, forced connections are unsafe and may cause operational problems.
For the mechanical compatibility of the module/converter and PEFS, use the
same connectors from the same manufacturer on both the PEFS and modules, or
obtain verification that the connectors to be used are compatible.
Introduction
Control Box includes Power Supply
-
PEFS-24V-C60
-
PEFS-24V-C180
Control Box External Power Supply
- PEFS-24V-C480
Installation & Connection
-
Open the box, take out PEFS-24V-CN and parts, read this manual.
-
Prepare materials and tools.
-
The installation modes of PEFS-24V-CN are divided into the following two situations.
Control Box includes Power Supply (Take PEFS-24V-C60 as an example)
a) Align the round hole of the L-shaped clasp with the round hole of the box
and fix them with screws.
b) Mount the control box to the appropriate location through the gourd-shaped hole.
c) Wring.
Control Box External Power Supply (PEFS-24V-C480)
a) Pull out the clasps to both sides.
b) Mount the control box to the appropriate location through the gourd-shaped hole.
c) Wiring
PEFS-24V-C480 does not have a power supply, so an external power supply is
required to power the control box.
Parallel connection of multiple control boxes
Technical Specification
Control Box (Include Power Supply)
Model | PEFS-24V-C60 | I PEFS-24V-C180 |
---|---|---|
Operating AC Voltage Range | 100 V 240 V | |
Nominal Frequency | 50/60 Hz | |
Output Voltage | 24V DC | |
Max. Output Current | 2.2A | 1 8.8A |
24Vdc Control Cable Size | 0.823 mm2 / 18 AWG | |
24Vdc Control Cable Length With Standard Connectors | 20m/30 m/100 m | |
Spare Terminal Connectors | Yes | |
Maximum PEFS-PL80S-11 | 60 Units | 180 Units |
Maximum PEFS-PL80S-21 | 30 Units | 90 Units |
Dimensions (mm) | 155’188’63 | 265’218’63 |
With Lock | Optional (IP54) | |
Operating Temperature Range | -30 C — +70 C | |
Protection Class | IP65 | |
Mounting | Wall Mounted |
Maximum Distance
(Last RSD to Controller Box)| 200m
Control Box (External Power Supply)
Model | PEFS-24V-C480 |
---|---|
Operating AC Voltage Range | 100 V-240 V |
Nominal Frequency | 50/60 Hz |
Output Voltage | 24V DC |
Output Current / Per String | 2.2A |
24Vdc Control Cable Size | 0.823 mm2 / 18 AWG |
24Vdc Control Cable Length With Standard Connectors | 20 m / 30 m 1100 m |
Spare Terminal Connectors | Yes |
Maximum PEFS-PL80S-11 / Per String | 60 Units |
Maximum PEFS-PL80S-21 / Per String | 30 Units |
Dimensions (mm) | 210’175’105 |
With Lock | Optional |
Operating Temperature Range | -30 C — +70 C |
Protection Class | IP65 |
Mounting | Wall Mounted |
Maximum Distance
(Last RSD to Controller Box)| 200m
Recommend Power Supply| Output Current| 20A
Maximum PEFS-PL80S-11| 480 Units
Maximum PEFS-PL80S-21| 240 Units
Trouble Shooting
Control Box (Include Power Supply)
Problem | Possible Cause | Possible Solution |
---|
Panel (pair)
voltage is OV| No mains supply| Check area utility operational
(LED OFF)| Check mains ON
Check mains fuse
PEFS-24V-CN power supply failure| Check mains voltage between L&N marked
terminals
Check 24VDC between + & – marked terminals
PEFS-24V-CN switch activated| Turn the red actuator anti-clockwise to release
the button
No PEFS-24V-CN switch output| Check 24VDC between switch out terminal & PSU —
marked terminal
Broken cable| Check 24VDC between terminals of remote AMP
Superseal connector (pin 1 +24VDC\pin 2 OVDC)
PV array not connected| Check all PV to PEFS-24V-CN input connections
Incorrect PEFS-24V-CN
polarity connection| Check PV array Positive (+) goes to PEFS-24V-CN
Positive (+) and PV array Negative (-) goes to PEFS-PC Negative (-)
No PEFS-24V-CN output| Replace PEFS-24V-CN
PV Inverter
input OV| No DC isolator (if fitted)| Check PEFS-24V-CN output connections
input| Check DC inputs to the isolator
DC Isolator (if fitted) OFF| Turn DC Isolator ON
String voltage
too low| Incorrect PEFS-24V-CN
polarity connection| Check all PV array Positive (+) go to PEFS-PC
Positive (+) and PV array Negative (-) goes to PEFS-PC Negative (-)
In the occurrence of a fire, PROJOY recommends that all elements of the PEFS Rapid Shutdown system be assessed for operational suitability by a competent person prior to re-energizing.
Aftersales service and warranty
This product is manufactured in a sophisticated quality management system. In case of fault, the following warranty and after-services clauses are applicable.
7.1 Warranty
On the premise of the user’s compliance with the reservation and use
specifications of the breaker, for breakers whose delivery date is within 60
months from now and whose seals are intact, PROJOY will repair or replace any
of these breakers which are damaged or cannot work normally due to manufacture
quality. However, as for faults caused by the following reasons, PROJOY would
repair or replace the breaker with a charge even it is still in warranty.
- Due to incorrect use, self-modification, and improper maintenance, etc.:
- Use beyond the requirements of standard specifications;
- After the purchase, due to falling and damage during installation, etc.;
- Earthquakes, fires, lightning strikes, abnormal voltages, other natural disasters, and secondary disasters, etc.
7.2 Aftersales service
- Please contact the supplier or our company’s after-sales service department in case of failure;
- During the warranty period: For failures caused by the company’s manufacturing problems, free repairs and replacements;
- After the warranty period expires: If the function can be maintained after the repair, make a paid repair, otherwise it can be replaced with a paid one.
Contact us
Projoy Electric Co., Ltd.
Tell : +86-512-6878 6489
Web: https://en.projoy-electric.com/