GIBSON KG7T Gas Furnace Owner’s Manual

June 15, 2024
Gibson

GIBSON KG7T Gas Furnace

Product Information

Technical Specifications

KG7T(AandKSeries)
TwoStage, FixedSpeed HighEfficiencyUpflow/Horizontal andDownflowGasFurnaces

InducedDraft-80+AFUE Input60,000-140,000Btuh

  • The high-efficiency gas furnace may be installed free-standing in a utility room, basement, or enclosed in an alcove or closet.
  • The rounded corner jacket provides a pleasing appliance appearance.
  • Design certified by CSA for application in the United States and Canada.

Warranty
There is no information about the warranty in the provided text.

Features and Benefits

  • Design assures product will arrive to the homeowner dent-free.
  • Works well with taller high SEER coils, making it easier to handle.
  • Duct temperature at furnace start-up is adjustable.
  • Utilizes type ignitor with a 20 year history of reliability.
  • Utilizes quick-connect fittings for ease of installation.
  • Increases cooling performance when matched with a dedicated venting system or common vented with other components.
  • Includes a dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes.
  • Uses captured screws to prevent losing door.
  • Offers up to 1 SEER point efficiency gain in cooling.

Gas Furnace Components

Upflow/Horizontal Gas Furnace

  1. Blower Assembly
  2. Blower Door Switch
  3. Burner Assembly
  4. Flame Roll-Out Switch
  5. Flame Sensor
  6. Furnace Control Board
  7. Gas Manifold
  8. Gas Valve
  9. Igniter
  10. Inducer Assembly
  11. Main Air Limit Switch
  12. Motor Choke (3/4 and 1HP only)
  13. Motor Control Board
  14. Motor Control Box
  15. Pressure Switch(s)
  16. Transformer

Downflow Gas Furnace

  1. Blower Assembly
  2. Blower Door Switch
  3. Burner Assembly
  4. Combustion Tube
  5. Flame Roll-Out Switch
  6. Flame Sensor
  7. Furnace Control Board
  8. Gas Manifold
  9. Gas Valve
  10. Igniter
  11. Inducer Assembly
  12. Main Air Limit Switch
  13. Motor Choke (3/4 and 1HP only)
  14. Motor Control Board
  15. Pressure Switch(s)
  16. Transformer

Dimensions

Upflow/Horizontal Gas Furnace

  • A: 12 inches
  • B: 12 inches
  • C: 15 inches
  • D: 16 inches
  • Front Brace: 21 inches
  • Bottom Panel: 14 inches
  • Top View: 19 inches
  • Flanges: 22 inches
  • Bottom View: 19 1/4 inches
  • Accepts 4″ Type B Vent Pipe

Downflow Gas Furnace

  • A: 12 inches
  • B: 12 inches
  • C: 15 inches
  • D: 16 inches
  • Front Brace: 21 inches
  • Bottom View: 14 inches
  • Top View: 19 inches
  • Flanges: 22 1/4 inches
  • Accepts 4″ Type B Vent Pipe

Blower Performance – KG7TA/TK
G7TA/TK-80% AFUE, Two-Stage Gas Furnace

Model Number| Heating Input (Btuh)| Motor Switch Setting| External Static Pressure (in.w.c.)| CFM Rise
---|---|---|---|---
0.1| 0.2| 0.3| 0.4| 1/5| Rise| 2/6| Rise| 3/7| Rise| 4/8| Rise
CFM| CFM| CFM| CFM| CFM| CFM| CFM
0.5| Rise| CFM| Rise| CFM| Rise| CFM| Rise
0.6| Rise| CFM| Rise| CFM| Rise| CFM| Rise
0.7| Rise| CFM| Rise| CFM| Rise| CFM| Rise
0.8| Rise| CFM| Rise| CFM| Rise| CFM| Rise
Notes:| 1. Motor Switch Settings are for heating speeds
using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL
switches 5, 6, 7, & 8.
2. Two openings are recommended for airflows above 1600 CFM if the
filter(s) is (are) adjacent to the furnace.
3. Data is shown without filter.
4. Temperature rises in the table are approximate. Actual
temperature rises may vary.
5. Temperature rises that are shaded in grey are for reference
only. These conditions are not recommended.

FAQ

  • What is the warranty for the product?
    There is no information about the warranty in the provided text.

  • What are the dimensions of the upflow/horizontal gas furnace?
    The dimensions of the upflow/horizontal gas furnace are as follows:

    • A: 12 inches
    • B: 12 inches
    • C: 15 inches
    • D: 16 inches
    • Front Brace: 21 inches
    • Bottom Panel: 14 inches
    • Top View: 19 inches
    • Flanges: 22 inches
    • Bottom View: 19 1/4 inches
    • Accepts 4″ Type B Vent Pipe
  • What are the dimensions of the downflow gas furnace?
    The dimensions of the downflow gas furnace are as follows:

    • A: 12 inches
    • B: 12 inches
    • C: 15 inches
    • D: 16 inches
    • Front Brace: 21 inches
    • Bottom View: 14 inches
    • Top View: 19 inches
    • Flanges: 22 1/4 inches
    • Accepts 4″ Type B Vent Pipe
  • What is the blower performance of the KG7TA/TK gas furnace?
    The blower performance of the KG7TA/TK gas furnace is shown in the provided table. It includes information on

Two Stage, Fixed Speed High Efficiency Upflow/Horizontal and Downflow Gas Furnaces

  • Induced Draft – 80+ AFUE
  • Input 60,000 – 140,000 Btuh

The high-efficiency gas furnace may be installed free-standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in the United States and Canada.

WARRANTY

  • 10-year all-parts warranty.
  • 10 Year Quality Pledge to replace the unit if the heat exchanger fails within the first 10 years of operation, to the original owner.
  • Consumer product registration is required for 10 years All Parts Warranty and Quality Pledge within a limited period after the installation. See the current warranty document or visit our consumer website listed on the back of this document for warranty details.
  • When registered, this product is upgraded to a limited lifetime heat exchanger warranty.

FEATURES and BENEFITS

  • 100% fired and tested: All units and each component are tested on the manufacturing line.
  • Best packaging in the industry: Unique corner post design assures the product will arrive to the homeowner dent-free.
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
  • 30-second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower-off settings (60, 90, 120 and 180 seconds).
  • 30-second post purge: Increases the life of the heat exchanger.
  • Hot surface ignitor: Innovative application of an appliance-type ignitor with a 20-year history of reliability. Utilizes proven Smartlite® technology.
  • Color-coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • High static blowers: All models are equipped with high static blowers.
  • 90-second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a NORDYNE coil.
  • Flexible category I venting system: This may be vented with the dedicated venting system or commonly vented with other category one appliances.
  • Variable speed blower kit: Upgradable to full variable speed with the kit.
  • LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
  • Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy-to-recognize states without counting flashes.
  • Integrated control board: Incorporates connections for electronic air cleaner, humidifier, and twinning.
  • Two-piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws.
  • Energy Efficient Brushless DC (ECM) Motor: Gives up to 1 SEER point efficiency gain in cooling.

GAS FURNACE COMPONENTS

  1. Blower Assembly

  2. Blower Door Switch

  3. Burner Assembly

  4. Flame Roll-Out Switch

  5. Flame Sensor

  6. Furnace Control Board

  7. Gas Manifold

  8. Gas Valve

  9. Igniter

  10. Inducer Assembly

  11. Main Air Limit Switch

  12. Motor Choke (3/4 and 1HP only)

  13. Motor Control Board

  14. Motor Control Box

  15. Pressure Switch(s)

  16. Transformer

  17. Blower Assembly

  18. Blower Door Switch

  19. Burner Assembly

  20. Combustion Tube

  21. Flame Roll-Out Switch

  22. Flame Sensor

  23. Furnace Control Board

  24. Gas Manifold

  25. Gas Valve

  26. Igniter

  27. Inducer Assembly

  28. Main Air Limit Switch

  29. Motor Choke (3/4 and 1HP only)

  30. Motor Control Board

  31. Pressure Switch(s)

  32. Transformer

DIMENSIONS

*TA Model #’s| Dimension “A”| Dimension “B”| Dimension “C”| Dimension “D”
---|---|---|---|---
060-23A1| 14 1/4| 10 3/4| 12 5/8| 12 7/8
080-24B1| 17 1/2| 11 3/4| 15 7/8| 16 1/8
100-24B1
100-35C1| ****

21

| ****

14

| 19 3/8| 19 5/8
120-35C1
140-45D1| 24 1/2| 15 1/4| 22 7/8| 23 1/8

BLOWER PERFORMANCE – KG7TA/TK

G7TA/TK – 80% AFUE, Two Stage Gas Furnace



Model Number

| ****

Heating Input (Btuh)

| Motor Switch Setting| External Static Pressure (in.w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
1/5| 2/6| 3/7| 4/8| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise









TA/TK-060(C)-A1

| ****








60000

| 0| 0| 0| 0| | | | | | | | | | | | | | | |
1| 0| 0| 0| | | | | | | | | | | | | | | |
0| 1| 0| 0| 600| 74| 555| 80| 510| | | | | | | | | | |
1| 1| 0| 0| 705| 63| 670| 66| 635| 70| 600| 74| | | | | | | |
0| 0| 1| 0| 775| 57| 740| 60| 705| 63| 665| 67| | | | | | | |
1| 0| 1| 0| 900| 49| 870| 51| 835| 53| 800| 56| 765| 58| 730| 61| 695| 64| 660| 67
0| 1| 1| 0| 950| 47| 920| 48| 890| 50| 855| 52| 825| 54| 795| 56| 765| 58| 730| 61
1| 1| 1| 0| 1000| 44| 970| 46| 940| 47| 910| 49| 880| 51| 850| 52| 820| 54| 790| 56
0| 0| 0| 1| 1075| 41| 1045| 43| 1015| 44| 985| 45| 960| 46| 925| 48| 900| 49| 870| 51
1| 0| 0| 1| 1110| 40| 1080| 41| 1055| 42| 1025| 43| 1000| 44| 975| 46| 945| 47| 920| 48
0| 1| 0| 1| 1170| 38| 1140| 39| 1115| 40| 1090| 41| 1060| 42| 1035| 43| 1010| 44| 985| 45
1| 1| 0| 1| 1210| 37| 1185| 38| 1160| 38| 1130| 39| 1105| 40| 1080| 41| 1055| 42| 1025| 43
0| 0| 1| 1| 1520| 29| 1225| 36| 1200| 37| 1175| 38| 1150| 39| 1120| 40| 1095| 41| 1070| 42
1| 0| 1| 1| 1305| 34| 1280| 35| 1255| 35| 1230| 36| 1205| 37| 1180| 38| 1155| 38| 1130| 39
0| 1| 1| 1| 1350| 33| 1230| 36| 1305| 34| 1285| 35| 1260| 35| 1240| 36| 1215| 37| 1195| 37
1| 1| 1| 1| 1440| 31| 1400| 32| 1365| 33| 1230| 36| 1295| 36| 1255| 35| 1220| 36| 1185| 38









TA/TK-080(C)-B1

| ****








80000

| 0| 0| 0| 0| | | | | | | | | | | | | | | |
1| 0| 0| 0| | | | | | | | | | | | | | | |
0| 1| 0| 0| | | | | | | | | | | | | | | |
1| 1| 0| 0| 725| 82| | | | | | | | | | | | | |
0| 0| 1| 0| 810| 73| | | | | | | | | | | | | |
1| 0| 1| 0| 940| 63| 890| 67| 845| 70| 795| 75| 750| 79| 700| 85| | | |
0| 1| 1| 0| 990| 60| 945| 63| 905| 65| 860| 69| 820| 72| 775| 76| 735| 81| 690| 86
1| 1| 1| 0| 1055| 56| 1015| 58| 970| 61| 930| 64| 890| 67| 845| 70| 805| 74| 760| 78
0| 0| 0| 1| 1135| 52| 1095| 54| 1055| 56| 1010| 59| 960| 62| 930| 64| 890| 67| 850| 70
1| 0| 0| 1| 1185| 50| 1145| 52| 1105| 54| 1065| 56| 1030| 58| 990| 60| 950| 62| 910| 65
0| 1| 0| 1| 1250| 47| 1210| 49| 1170| 51| 1135| 52| 1095| 54| 1055| 56| 1020| 58| 980| 60
1| 1| 0| 1| 1290| 46| 1255| 47| 1220| 49| 1180| 50| 1145| 52| 1110| 53| 1075| 55| 1040| 57
0| 0| 1| 1| 1315| 45| 1275| 46| 1240| 48| 1200| 49| 1160| 51| 1120| 53| 1085| 55| 1045| 57
1| 0| 1| 1| 1350| 44| 1315| 45| 1280| 46| 1245| 48| 1205| 49| 1170| 51| 1135| 52| 1100| 54
0| 1| 1| 1| 1390| 43| 1350| 44| 1315| 45| 1275| 46| 1240| 48| 1200| 49| 1160| 51| 1125| 53
1| 1| 1| 1| 1420| 42| 1380| 43| 1345| 44| 1310| 45| 1270| 47| 1235| 48| 1200| 49| 1160| 51

Notes:

  1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
  2. Two openings are recommended for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Temperature rises that are shaded in grey are for reference only. These conditions are not recommended.

G7TA/TK – 80% AFUE, Two Stage Gas Furnace



Model Number

| ****

Heating Input (Btuh)

| ****

Motor Switch Setting

| External Static Pressure (in.w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
1/5| 2/6| 3/7| 4/8| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise









*TA100(C)-* B1**

| ****








100000

| 0| 0| 0| 0| 905| 82| 890| 83| 805| 92| 780| 95| | | | | | | |
1| 0| 0| 0| 980| 76| 930| 80| 900| 82| 835| 89| 820| 90| 800| 93| 715| 104| 670| 111
0| 1| 0| 0| 1095| 68| 1015| 73| 980| 76| 915| 81| 895| 83| 870| 85| 810| 91| 765| 97
1| 1| 0| 0| 1160| 64| 1100| 67| 1065| 70| 1035| 72| 995| 74| 940| 79| 895| 83| 865| 86
0| 0| 1| 0| 1230| 60| 1195| 62| 1170| 63| 1110| 67| 1075| 69| 1060| 70| 995| 74| 970| 76
1| 0| 1| 0| 1315| 56| 1275| 58| 1240| 60| 1195| 62| 1160| 64| 1140| 65| 1115| 66| 1075| 69
0| 1| 1| 0| 1345| 55| 1310| 57| 1280| 58| 1250| 59| 1220| 61| 1190| 62| 1140| 65| 1115| 66
1| 1| 1| 0| 1445| 51| 1390| 53| 1350| 55| 1315| 56| 1280| 58| 1250| 59| 1230| 60| 1185| 63
0| 0| 0| 1| 1490| 50| 1430| 52| 1420| 52| 1380| 54| 1340| 55| 1310| 57| 1280| 58| 1275| 58
1| 0| 0| 1| 1550| 48| 1510| 49| 1475| 50| 1450| 51| 1420| 52| 1375| 54| 1340| 55| 1325| 56
0| 1| 0| 1| 1600| 46| 1270| 58| 1540| 48| 1500| 49| 1475| 50| 1445| 51| 1425| 52| 1385| 53
1| 1| 0| 1| 1640| 45| 1605| 46| 1570| 47| 1550| 48| 1525| 49| 1490| 50| 1460| 51| 1430| 52
0| 0| 1| 1| 1690| 44| 1665| 44| 1630| 45| 1600| 46| 1570| 47| 1550| 48| 1515| 49| 1490| 50
1| 0| 1| 1| 1755| 42| 1730| 43| 1680| 44| 1660| 45| 1640| 45| 1610| 46| 1575| 47| 1550| 48
0| 1| 1| 1| 1805| 41| 1770| 42| 1740| 43| 1715| 43| 1690| 44| 1655| 45| 1645| 45| 1605| 46
1| 1| 1| 1| 1860| 40| 1825| 41| 1790| 41| 1765| 42| 1745| 42| 1710| 43| 1695| 44| 1660| 45









TA/TK-100(C)-C1

| ****








100000

| 0| 0| 0| 0| 1125| 66| 1040| 71| 960| 77| | | | | | | | | |
1| 0| 0| 0| 1205| 61| 1120| 66| 1040| 71| 960| 77| | | | | | | |
0| 1| 0| 0| 1305| 57| 1225| 60| 1150| 64| 1070| 69| 995| 74| 915| 81| | | |
1| 1| 0| 0| 1430| 52| 1350| 55| 1270| 58| 1190| 62| 1110| 67| 1030| 72| 950| 78| 865| 86
0| 0| 1| 0| 1525| 49| 1450| 51| 1375| 54| 1300| 57| 1225| 60| 1150| 64| 1075| 69| 1000| 74
1| 0| 1| 0| 1620| 46| 1540| 48| 1465| 51| 1390| 53| 1315| 56| 1240| 60| 1165| 64| 1090| 68
0| 1| 1| 0| 1695| 44| 1620| 46| 1545| 48| 1465| 51| 1390| 53| 1315| 56| 1235| 60| 1160| 64
1| 1| 1| 0| 1770| 42| 1700| 44| 1630| 45| 1555| 48| 1485| 50| 1410| 53| 1340| 55| 1265| 59
0| 0| 0| 1| 1875| 40| 1805| 41| 1730| 43| 1655| 45| 1580| 47| 1510| 49| 1435| 52| 1340| 55
1| 0| 0| 1| 1905| 39| 1840| 40| 1775| 42| 1710| 43| 1640| 45| 1575| 47| 1510| 49| 1445| 51
0| 1| 0| 1| 1980| 37| 1910| 39| 1845| 40| 1780| 42| 1715| 43| 1650| 45| 1580| 47| 1515| 49
1| 1| 0| 1| 2025| 37| 1960| 38| 1895| 39| 1830| 40| 1765| 42| 1700| 44| 1635| 45| 1570| 47
0| 0| 1| 1| 2085| 36| 2025| 37| 1960| 38| 1900| 39| 1840| 40| 1775| 42| 1715| 43| 1655| 45
1| 0| 1| 1| 2135| 35| 2070| 36| 2010| 37| 1945| 38| 1880| 39| 1815| 41| 1750| 42| 1685| 44
0| 1| 1| 1| 2200| 34| 2145| 35| 2090| 35| 2035| 36| 1980| 37| 1925| 38| 1870| 40| 1820| 41
1| 1| 1| 1| 2280| 32| 2225| 27| 2170| 34| 2115| 35| 2065| 22| 2010| 37| 1955| 38| 1900| 39

Notes:

  1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
  2. Two openings are recommended for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Temperature rises that are shaded in grey are for reference only. These conditions are not recommended.

G7TA/TK – 80% AFUE, Two Stage Gas Furnace


Model Number

| Heating Input (Btuh)| Motor Switch Setting| External Static Pressure (in.w.c.)
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
1/5| 2/6| 3/7| 4/8| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise









TA/TK-120(C)-C1

| ****








120000

| 0| 0| 0| 0| 1125| 79| 1040| | | | | | | | | | | | |
1| 0| 0| 0| 1205| 74| 1120| 79| 1040| 85| | | | | | | | | |
0| 1| 0| 0| 1305| 68| 1225| 73| 1150| 77| 1070| 83| | | | | | | |
1| 1| 0| 0| 1430| 62| 1350| 66| 1270| 70| 1190| 75| 1110| 80| 1030| 86| | | |
0| 0| 1| 0| 1525| 58| 1450| 61| 1375| 65| 1300| 68| 1225| 73| 1150| 77| 1075| 83| 1000| 89
1| 0| 1| 0| 1620| 55| 1540| 58| 1465| 61| 1390| 64| 1315| 68| 1240| 72| 1165| 76| 1090| 82
0| 1| 1| 0| 1695| 52| 1620| 55| 1545| 58| 1465| 61| 1390| 64| 1315| 68| 1235| 72| 1160| 77
1| 1| 1| 0| 1770| 50| 1700| 52| 1630| 55| 1555| 57| 1485| 60| 1410| 63| 1340| 66| 1265| 70
0| 0| 0| 1| 1875| 47| 1805| 49| 1730| 51| 1655| 54| 1580| 56| 1510| 59| 1435| 62| 1340| 66
1| 0| 0| 1| 1905| 47| 1840| 48| 1775| 50| 1710| 52| 1640| 54| 1575| 56| 1510| 59| 1445| 62
0| 1| 0| 1| 1980| 45| 1910| 47| 1845| 48| 1780| 50| 1715| 52| 1650| 54| 1580| 56| 1515| 59
1| 1| 0| 1| 2025| 44| 1960| 45| 1895| 47| 1830| 49| 1765| 50| 1700| 52| 1635| 54| 1570| 57
0| 0| 1| 1| 2085| 43| 2025| 44| 1960| 45| 1900| 47| 1840| 48| 1775| 50| 1715| 52| 1655| 54
1| 0| 1| 1| 2135| 42| 2070| 43| 2010| 44| 1945| 46| 1880| 47| 1815| 49| 1750| 51| 1685| 53
0| 1| 1| 1| 2200| 40| 2145| 41| 2090| 43| 2035| 44| 1980| 45| 1925| 46| 1870| 48| 1820| 49
1| 1| 1| 1| 2280| 39| 2225| 40| 2170| 41| 2115| 42| 2065| 43| 2010| 44| 1955| 45| 1900| 47









TA/TK-140(C)-D1

| ****








140000

| 0| 0| 0| 0| 1395| 74| 1350| 77| 1305| 79| 1260| 82| 1210| 86| 1165| 89| | | |
1| 0| 0| 0| 1465| 71| 1420| 73| 1375| 75| 1330| 78| 1290| 80| 1245| 83| 1200| 86| |
0| 1| 0| 0| 1555| 67| 1510| 69| 1470| 71| 1425| 73| 1380| 75| 1340| 77| 1295| 80| 1250| 83
1| 1| 0| 0| 1625| 64| 1585| 65| 1540| 67| 1500| 69| 1460| 71| 1415| 73| 1375| 75| 1335| 78
0| 0| 1| 0| 1690| 61| 1650| 63| 1610| 64| 1570| 66| 1530| 68| 1485| 70| 1445| 72| 1405| 74
1| 0| 1| 0| 1760| 59| 1715| 60| 1670| 62| 1625| 64| 1575| 66| 1530| 68| 1485| 70| 1440| 72
0| 1| 1| 0| 1835| 57| 1790| 58| 1745| 59| 1695| 61| 1650| 63| 1605| 65| 1555| 67| 1510| 69
1| 1| 1| 0| 1885| 55| 1840| 56| 1790| 58| 1745| 59| 1700| 61| 1655| 63| 1610| 64| 1565| 66
0| 0| 0| 1| 1945| 53| 1900| 55| 1850| 56| 1805| 57| 1760| 59| 1710| 61| 1665| 62| 1620| 64
1| 0| 0| 1| 1950| 53| 1905| 54| 1860| 56| 1820| 57| 1775| 58| 1735| 60| 1690| 61| 1650| 63
0| 1| 0| 1| 2075| 50| 2030| 51| 1990| 52| 1945| 53| 1900| 55| 1855| 56| 1810| 57| 1770| 59
1| 1| 0| 1| 2125| 49| 2085| 50| 2040| 51| 2000| 52| 1955| 53| 1910| 54| 1870| 55| 1825| 57
0| 0| 1| 1| 2170| 48| 2130| 49| 2090| 50| 2045| 51| 2005| 52| 1965| 53| 1925| 54| 1880| 55
1| 0| 1| 1| 2215| 47| 2180| 48| 2140| 48| 2105| 49| 2070| 50| 2035| 51| 2000| 52| 1965| 53
0| 1| 1| 1| | | | | | | | | 2225| 47| 2165| 48| 2100| 49| 2040| 51
1| 1| 1| 1| | | | | | | | | | | 2170| 48| 2120| 49| 2065| 50

Notes:

  1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8.
  2. Two openings are recommended for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Temperature rises that are shaded in grey are for reference only. These conditions are not recommended.

MODEL IDENTIFICATION CODE

SPECIFICATIONS

KG7TA/TK **MODEL NUMBERS| **

060C-23A1

| ****

080C-24B1

| ****

100C-24B1

| ****

100C-35C1

| ****

120C-35C1

| ****

140C-45D1

---|---|---|---|---|---|---
Input – Btuh (a)| 60,000 / 39,000| 80,000 / 52,000| 100,000 / 65,000| 100,000 / 65,000| 120,000 / 78,000| 140,000 / 91,000
Heating Capacity – Btuh| 48,000 / 31,200| 64,000 / 41,600| 80,000 / 52,600| 80,000 / 52,600| 96,000 / 62,400| 112,000 / 72,800
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0
Blower D x W| 10 x 6| 11 x 8| 11 x 8| 11 x 10| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 1/2 BLDC| 1/2 BLDC| 1/2 BLDC| 3/4 BLDC| 3/4 BLDC| 1 BLDC
Motor FLA| 6.2| 6.2| 8.7| 8.7| 8.7| 11.7
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 25-55| 30-60| 30-60| 35-65| 35-65| 40-70
Shipping Weights| 115lbs| 110lbs| 120lbs| 125lbs| 135lbs| 155lbs

  • All models are 115 V, and 60 HZ. Gas connections are 1/2″ N.P.T.
  • AFUE= Annual Fuel Utilization Efficiency

ACCESSORIES

KG7TA/TK KITS

Description| SKU
Fixed speed -to- variable speed| 904880
“A” Cabinet downflow sub base kit| 902974
“B”, “C”, “D” Cabinet downflow sub base kit| 904911
U.S. LP Conversion kit (0 to 10,000 ft.)| 904914
Canada LP Conversion kit (0 to 4,500 ft.)| 904915
Bottom return filter 20 per box, “A” cabinet| 903088
Bottom return filter 20 per box, “B” cabinet| 904916
Bottom return filter 20 per box, “C” cabinet| 904917
Bottom return filter 20 per box, “D” cabinet| 904918
Side return filter kit| 541036

GENERAL TERMS OF LIMITED WARRANTY

  • NORDYNE will furnish a replacement for any part of this product that fails in normal use and service within the first ten years of installation, under the terms of the warranty.
  • For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the NORDYNE warranty department for a copy.

8000 Phoenix Parkway | O’Fallon, MO 63368-3827

Specifications and illustrations are subject to change without notice and without incurring obligations. Printed in U.S.A (02/2010) 834C-0210 (Replaces 834C-1009)

GIBSON is a pending or registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc. © Nortek Global HVAC, LLC. All Rights Reserved. www.gibsonhvac.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Gibson User Manuals

Related Manuals