Product Information

Specifications:

  • Control panel power supply: Back-up battery
  • Maximum battery charging time: 12 hours
  • BUS voltage (red – black)
  • Maximum continuous current consumption from the control panel
  • Max. continuous current consumption for backup 12 hours
  • Max. continuous current consumption for back-up 24 hours
  • Maximum number of devices: 50
  • LAN communicator: Ethernet interface, 10/100BASE
  • Dimensions: 268 x 225 x 83 mm
  • Weight with/without AKU: 1844 g/970 g
  • Reaction to invalid code entry: Alarm after 10 wrong code entries
  • Event memory: Approx. 7 million latest events, including date and time
  • Power supply unit: Type A according to EN 50131-6 T 031 note
  • GSM communicator (2G): 850 / 900 / 1800 / 1900 MHz
  • Classification: Security grade 2 according to EN 50131-1
  • Operational environment: Environmental class II (indoor general) according to EN 50131-1
  • Operational temperature range: -10°C to +55°C
  • Average operational humidity: 75% RH, non-condensing
  • Complies with: EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, EN 50131-10, EN 50136-1, EN 50136-2, EN 50581
  • Radio operating frequency (with the JA 11xR module): 868.1 MHz
  • Radio emissions: ETSI EN 300 220-1,-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM)
  • EMC Safety conformity: EN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7, EN 62368-1+A11
  • Caller identification (CLIP)
  • Operational conditions: Certification body: ERC REC 70-03 Trezor Test s.r.o. (no. 3025)

Product Usage Instructions

Installation:
The JA-103KR GSM Control panel should only be installed by a trained technician with a valid Jablotron Alarms certificate.

System Adjustments and Sizing:
The required adjustments and sizing of the system are programmed through the F-Link software (from version 2.0.0).

Control Panel Features:

  • 50 wireless or bus devices
  • 50 users
  • 8 sections
  • 32 programmable PG outputs
  • 20 mutually independent calendar events
  • 8 user SMS and voice reports
  • 5 ARCs can be set
  • 5 selectable protocols for an ARC

Control Panel Connections:

  • 1 terminal board for bus connection
  • 1 connector for a built-in radio module (JA-111R)
  • 1 connector for a GSM/GPRS communicator (JA-192Y)

Control Panel Functions:

  • Maintenance
  • Day/night mode
  • Short departure response
  • Automatic setting
  • Advanced calendar features

Incompatible Products:
The following products are NOT COMPATIBLE with the control panel:

  • JA-180A (wireless outdoor siren)
  • JA-154J (bi-directional remote control)
  • JA-190X (PSTN communicator module)

Compatibility with Certain Conditions:
The following products are COMPATIBLE with the control panel under certain conditions:

  • The JA-112E (keyboard) is compatible with FW LU61501 and higher
  • The JA-113E (keyboard) is compatible with FW LU61601 and higher
  • The JA-118N (PG Bus Output Module) is compatible with LY68003 and higher
  • FW version LY68002 and lower works only when the PG range is set in the F-Link up to a maximum value of 32
  • The JA-110I (section or PG bus indicator) is compatible only when the PG range is set in the F-Link up to a maximum value of 32

FAQ

  • Q: How should I install the JA-103KR GSM Control panel?
    A: The JA-103KR GSM Control panel should only be installed by a trained technician with a valid Jablotron Alarms certificate.

  • Q: What software is used for adjusting and sizing the system?
    A: The required adjustments and sizing of the system are programmed through the F-Link software (from version 2.0.0).

  • Q: How many devices can be connected to the control panel?
    A: The control panel supports a maximum of 50 wireless or bus devices.

  • Q: How many users can be registered with the control panel?
    A: The control panel can register up to 50 users.

  • Q: What is the operational temperature range of the control panel?
    A: The control panel can operate within a temperature range of -10°C to +55°C.

JA-103KR GSM Control panel with LAN and radio module
The core element of the JABLOTRON 100+ security system. A control panel for protecting family houses, offices and smaller companies. It can only be installed by a trained technician with a valid Jablotron Alarms certificate.

Description

The required adjustments and sizing of the system are programmed through the F-Link software (from version 2.0.0). The JA-103K control panel offers:

  • 50 wireless or bus devices
  • 50 users
  • 8 sections
  • 32 programmable PG outputs
  • 20 mutually independent calendar events
  • 8 user SMS and voice reports
  • 5 ARCs can be set
  • 5 selectable protocols for an ARC

The control panel has:

  • 1 terminal board for bus connection
  • 1 connector for a built-in radio module (JA-111R)
  • 1 connector for a GSM/GPRS communicator (JA-192Y)

The control panel also offers functions such as:

  • Maintenance
  • Day/night mode
  • Short departure response
  • Automatic setting
  • Advanced calendar features

The following products with the control panel ARE NOT COMPATIBLE:

  • JA-180A (wireless outdoor siren)
  • JA-154J (bi-directional remote control)
  • JA-190X (PSTN communicator module)

The following products with the control panel ARE COMPATIBLE under certain conditions:

  • The JA-112E (keyboard) is compatible with FW LU61501 and higher
  • The JA-113E (keyboard) is compatible with FW LU61601 and higher
  • The JA-118N (PG Bus Output Module) is compatible with LY68003 and higher
  • FW version LY68002 and lower works only when the PG range is set in the F-Link up to a maximum value of 32
  • The JA-110I (section or PG bus indicator) is compatible only when the PG range is set in the F-Link up to a maximum value of 32

Technical specifications

  • Control panel power supply ~ 110 – 230 V/50 – 60 Hz, max. 0.28 A with fuse F1.6 A/250 V, Protection class II
  • Back-up battery 12 V; 2.6 Ah (lead gel)
  • Maximum battery charging time 48 h
  • BUS voltage (red – black) 12.0 to 13.8 V
  • Maximum continuous current consumption from the control panel 1000 mA
  • Max. continuous current consumption for back-up 12 hours
    • Without GSM communicator
    • LAN – OFF: 115 mA
    • LAN – ON: 88 mA
    • With GSM communicator
    • LAN – OFF: 80 mA
    • LAN – ON: 53 mA
  • Max. continuous current consumption for back-up 24 hours
    • Without GSM communicator LAN – OFF: 21 mA
    • With GSM communicator LAN – OFF: 17 mA
  • Maximum number of devices 50
  • LAN communicator Ethernet interface, 10/100BASE
  • Dimensions 268 x 225 x 83 mm
  • Weight with/without AKU 1844 g/970 g
  • Reaction to invalid code entry Alarm after 10 wrong code entries
  • Event memory Approx. 7 million latest events, including date and time
  • Power supply unit Type A according to EN 50131-6 T 031 note: In case of a main power failure is the system backed up for 24 hours and at the same time is a failure report sent to the ARC.
  • GSM communicator (2G) 850 / 900 / 1800 / 1900 MHz
  • Classification Security grade 2 according to EN 50131-1
  • Operational environment Environmental class II (indoor general) according to EN 50131-1
  • Operational temperature range -10 °C to +40 °C
  • Average operational humidity 75 % RH, non-condensing
  • Complies with EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, EN 50131-10, EN 50136-1, EN 50136-2, EN 50581
  • Radio operating frequency (with the JA 11xR module) 868.1 MHz
  • Radio emissions ETSI EN 300 220-1,-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM)
  • EMC EN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7
  • Safety conformity EN 62368-1+A11
  • Caller identification (CLIP) ETSI EN 300 089
  • Operational conditions ERC REC 70-03
  • Certification body Trezor Test s.r.o. (no. 3025)

Contact Information

JABLOTRON ALARMS a.s.
Pod Skalkou 4567/33 | 466 01 | Jablonec n. Nisou I Czech Republic www.jablotron.com.