  1. Dust Cover
  2. 24mm Flange Insert
  3. 20mm Flange Insert
  4. 17mm Flange Insert
  5. 14mm Flange Insert
  6. Breast Shield (27mm Flange)
  7. Connector Body
  8. Suction Bowl
  9. Valve
  10. Milk Collector
  11. Pump Motor
  12. USB Charging Cable

Button Function & LED Display Description

  • A Power Button: Press and hold for 2 seconds to turn the machine on/off. Press once to pause; the machine will shut down automatically after pausing for 5 minutes without any operation. The product will also shut down automatically after working for 30 minutes.
  • B Mode Switch Button: Short press to cycle through stimulation mode, expression mode, bionic mode, and auto mode.
  • C Level Up Button: Increases suction level from level 1 to level 12.
  • D Level Down Button: Decreases suction level.
  • E Stimulation Mode: Consists of a total of 12 levels with a fast pumping frequency and small suction to effectively stimulate the mammary gland for lactation.
  • F Expression Mode: Consists of a total of 12 levels with slow pumping frequency and large suction, suitable for rapid milk collection.
  • G Bionic Mode: Consists of a total of 12 levels, where stimulation and expression modes are combined to simulate the baby’s pumping, making the pumping process more immersive.
  • H Automatic Mode: In automatic mode, expression mode and bionic mode will work simultaneously.
  • I Level/Working Time Display: Displays the current suction level and running time.
  • J Power Display: The breast pump display features three power frames for easy monitoring.
  • K Time/Minute.

Battery Charging Operation

This product is equipped with a built-in lithium battery. When the LED power display shows 1 red bar and flashes, it indicates that you should charge the battery soon. Follow the steps below to charge the product:

nuliie YM-8806 Wearable Breast Pump User Manual - Battery Charging
Operation

NOTE: Do not use the product while it is charging. While charging, the display interface will only show the power level. 04

Battery Charge Status

nuliie YM-8806 Wearable Breast Pump User Manual - Battery Charge
Status

Assembly

⚠ CAUTIONS Ensure that you clean the pump as instructed in this user manual. Wash your hands thoroughly before assembling the cleaned components.

How to choose the correct flange insert?
  1. Place the nipple root against a ruler or use a nipple measuring tool to measure its diameter in millimeters (mm).
  2. Refer to the size chart for guidance on selecting the appropriate flange size for a comfortable and efficient pumping experience.

NOTE: If your nipple rubs or feels squeezed in the flange tube, it indicates an unsuitable flange size. Please replace it with the correct-size flange.

Assemble the Pump

nuliie YM-8806 Wearable Breast Pump User Manual - Assemble the
Pump nuliie YM-8806 Wearable
Breast Pump User Manual - Assemble the Pump

Operation Instruction

Prior to Pumping
  1. For proper assembly of the pump, follow the instructions provided in this user manual.
  2. To stimulate mammary gland growth before using the breast pump, warm the breasts for five minutes using a heated towel or a hot and cold compress.
Starting the Pumping Process

nuliie YM-8806 Wearable Breast Pump User Manual - Starting the Pumping
Process

Pumping Process Completion

nuliie YM-8806 Wearable Breast Pump User Manual - Pumping Process
Completion

Cleaning Washable Accessories

The washable accessories include: Dust Cover, Flange Insert, Breast Shield, Connector Body, Suction Bowl, Valve, and Milk Collector.

Washing:

  1. Rinse all the separated parts that come into contact with the breast and breast milk in cool water to remove any residue.
  2. Soak the parts in warm soapy water for 5 minutes. Finally, wash and rinse the parts thoroughly.

Disinfection:

  1. Place the accessories in boiling water and let them simmer for 5 minutes. Ensure that the temperature does not exceed 100°C (212°F).
  2. Alternatively, you can use a dishwasher or steam sterilization method to clean the accessories.

Tips:

  1. Before use, please disassemble each accessory individually for cleaning and sanitizing.
  2. After cleaning the accessories, allow them to air dry. Store the dry accessories in a cool place when not in use. Avoid storing wet parts.
  3. It is not recommended to sterilize breast pump accessories using a microwave oven or ultraviolet disinfection cabinet as it may reduce their durability.

Trouble Shooting

nuliie YM-8806 Wearable Breast Pump User Manual - Trouble
Shooting nuliie YM-8806
Wearable Breast Pump User Manual - Trouble Shooting

Cautions

  1. Nuliie breast pump is designed for individual use only. Sharing it with multiple users can compromise their health and safety.
  2. To avoid the risk of combustion and explosion, keep the motor away from high temperatures and ignition sources.
  3. If you experience little or no breast milk expression or pain while expressing breast milk, please consult a medical professional.
  4. Do not immerse the motor in water for cleaning or disinfection, and avoid using steam sterilizers for disinfection.
  5. Please use a 5V adapter for charging. If the output voltage of the power adapter exceeds 5V, the level indicator will show “E1” and the motor will activate over-voltage protection, preventing it from being charged.
  6. During the usage and cleaning of the accessories, the parts undergo various temperature changes and exposure to chemical detergents. We recommend replacement of the parts every 3 to 6 months, and if you notice any damage, please replace them promptly.

FCC
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.

CORRECT DISPOSAL OF THIS PRODUCT
(Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicate that it should not be disposed with other household wastes at the end of its working life.

To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household user should contact either the retailer where they purchased this product or their local government office, for details of where and how they can take this item for environmentally safe recycling.

Business users should contact their supplier and check the terms and conditions of the purchase contact. This product should not be mixed with other commercial wastes for disposal.

Manufacturer: Guangdong Youmeng Electrical Technology Co., Ltd.
Address: One of Area A, level 3, Building 2, No. 17, Keyuan 3rd Road, Xiaohuangpu Community, Ronggui Street, Shunde District, Foshan City, Guangdong Province, China

UK | REP
CET PRODUCT SERVICE LTD.
Beacon House Stokenchurch Business Park,
Ibstone Rd, Stokenchurch
High Wycombe HP14 3FE UK
Email: info.cetservice@gmail.com
Phone: +447419325266

EC | REP
UAB Qixiang Europe
Pranciškonų g. 6-46, LT-01133 Vilnius, Lithuania
Technical Information Center
Trakehner Str. 7-9, 60487 Frankfurt am Main, Germany
Email: qixiang.europe@gmail.com
Phone: +496976895074https://www.nuliie.com/faq/

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals