COMMSCOPE MUK-PLK11 Structural Support Equipment User Guide

June 15, 2024
CommScope

MUK-PLK11 Structural Support Equipment

REVISIONS

REV. DESCRIPTION DATE APPROVED
A INITIAL RELEASE JL1183
24AUG23 YC1015

40177353CMO

GENERAL NOTES

1.1 ALL METRIC DIMENSIONS ARE IN BRACKETS [X. X] 1.2 FOR PATENT INFO: https://www.cs-pat.com

DESIGN NOTES

2.1 ANY HAZARDS OR OBSTRUCTIONS TO THE CLIMBING FACILITY AND SAFETY CLIMB MUST BE IDENTIFIED PRIOR TO INSTALLING THE APPURTENANCE. ADDITIONAL PRODUCTS MAY BE REQUIRED TO MAINTAIN THE INTEGRITY OF THE SAFETY CLIMB. DURING INSTALLATION, TEMPORARY AND/OR PERMANENT PRECAUTIONARY MEASURES SHOULD BE TAKEN TO PRESERVE THE CLIMBING FACILITY AND/OR SAFETY CLIMB.
2.2 FIT ON MONOPOLE COLLAR MOUNT WITH 6″ X 6″ HOLE SPACING.

MANUFACTURING/SPECIAL REQUIREMENTS

3.1 TIGHTEN ALL BOLTS SECURING FLAT PLATES BY THE TURN-OF-NUT METHOD. TIGHTEN ALL
U-BOLTS USING TURN-OF-NUT METHOD WITH ATTENTION TO LEAVE EQUAL DISTANCE AND
EQUAL FORCE ON EACH LEG OF THE U-BOLT.

TEST

PACKAGING

5.1 PACKAGING SHALL MEET COMMSCOPE REQUIREMENTS PER DOCUMENT IS-PL-3005
5.2 PRINTED DOCUMENT TO BE PLACED INSIDE POLYBAG AND THEN IN SHIPPING CONTAINER
5.3 EXTRA HARDWARE MAYBE SUPPLIED, BAGGED AND SHIPPED COMPONENT PART NUMBERS PROVIDED FOR ASSEMBLY PURPOSES;
INDIVIDUAL COMPONENTS MAY BE SHIPPED AS PARTS WITHIN AN INCLUDED KIT.

ITEM NO.| PART NUMBER| DESCRIPTION| QTY.| WEIGHT| NOTE NO.
---|---|---|---|---|---
1| TB-10X4-00| TUBE, 1011x e| 1| 24.38 LBS|
2| GB-0520A| 518- X 2′ GALV BOLT KIT (A325)| 4| 0.26 LBS| INCLUDES BOLT, LOCK WASHER AND NUT
3| GWFO5A| GALV FLAT WASHER HARDENED 518′ 1 300| 4| 0.04 LBS|

References