Soler Palau DECOR-100 Electric Exhaust Fan User Manual

June 15, 2024
Soler Palau

Soler Palau DECOR-100 Electric Exhaust Fan User Manual

DECOR Axial Extractor Fans

This instruction manual contains important information and must be read carefully by competent persons prior to any handling, transport, inspection or installation of this product. Every care has been taken in the preparation of the instructions and information; however, it is the responsibility of the installer to ensure the system complies with relevant national and international regulations, especially safety.
The manufacturer, Soler & Palau Sistema’s de Ventilations S.L.U. accepts no responsibility for breakages, accidents or any inconvenience caused by failure to comply with the instructions contained in this manual. The fans referred to in this manual have been manufactured in accordance with rigorous quality control and International standard ISO 9001. We recommend you to check the following points when you receive this extractor:

  1. Make sure you have received the right model
  2. Make sure that the data on the nameplate are appropriate to your needs: voltage, frequency, speed, etc. Once the product has been installed, this manual to be retained by the end user.

SAFETY RECOMMENDATIONS

The installation must be carried out in accordance with current regulations in each country. The installation must be carried out by a qualiied professional.
The electrical installation must incorporate an omnipolar switch with an opening between contacts of at least 3 mm, appropriate for the load and complying with current standards. In bathrooms, the device must be installed outside the reach of any person taking a shower or a bath and.
the switch must be installed outside the bathroom. Do not use these fans in explosive or corrosive atmospheres. If the DÉCOR DESIGN is working in a kitchen where there is a boiler or any other kind of combustion device that needs air to work, check that the air inlets to the kitchen are
suficient.
The extractor discharge cannot be connected to a conduit for the evacuation of smoke from devices worked by gas or any other fuel. In the event of considerable humidity, you are advised to install the discharge conduit horizontally, with a slight outwards slant.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

INSTALLATION FIG.1

IMPORTANT: Before installing and wiring the unit, ensure that the main supply is switched off.

  1. Protection grille
  2. Fixing screw
  3. 3. Connection terminals
  4. Outlet with backdraught shutter
  5. Cable entry

The DECOR can either discharge directly to the outside or via an individual or central ducting system (see Fig. 2)
Installation Instruction
.
The unit can be mounted on the wall or ceiling using the 4 rubber blocksand the screws provided. Drill a hole in chosen position in the wall or ceiling of: (Fig.1). I

f the unit is to be installed with individual ducting, use a standard duct:

  • * DECOR-100: 100 mm
    • DECOR-200: 125 mm
    • DECOR-300: 150-160 mm

Loosen the screw (2) , which holds the grille in place (1) and remove the grille. Ensure that there are no obstructions to the airlow and that the impeller turns freely.
Fix the extractor to the wall in such a way that it is not distorted in order to avoid noise generation or problems with the rotation of the impeller. Make sure that the back draught shutter opens freely and has not being damaged in transit.
Introduce the mains cable through one of the cable point (5) and ix it to the wall so that the ixing screw (2) is above. Connect the electrical wiring as set out below and then mount the protection grille (1) and tighten the screw (2).

ELECTRICAL CONNECTION
Note Icon This appliance is considered to be suitable for use
in countries having a warm
damp equable climate as specified in IEC 60721-2-1. It may also
be used in other countries.

The DECOR-100 is an extractor designed for a single phase supply, with voltage and frequency as indicated on the rating plate of the unit. The units are manufactured with double electrical insulation (Class II) and therefore they do not need an earth connection. In addition to the switch shown in the installation drawing/diagram, there must be an All Pole switch in the ixed wiring with a contact opening of min 3 mm.
The electrical cable must enter the DECOR-100 through one of the cable point (5). Once the cable has been introduced proceed using the electrical wiring diagram applicable to the selected model.
DECOR S, C, SZ, CZ
These models use the following diagrams: Fig.3:
Installation Instruction
Fan operating through the light switch. Fig.4 :
Installation Instruction
Fan operating through an independent switch.

DECOR R, CR, RZ, CRZ
These models are itted with an adjustable timer. The timer enables the fan to continue running for the selected period after the switch has been turned off. Fig.5 :
Installation Instruction
Fan operating through an independent switch. Fig.6:
Installation Instruction
Fan operating through a light switch.

The desired run-on time is selected by means of an adjuster positioned on the printed circuit board (ig. 7) and accessible once the grille (1) has been removed:

  • To reduce the run-on time, turn anticlockwise (min. 1 minute).
  • To increase the run-on time, turn clockwise (max: 30 minutes).

DECOR H, CH, HZ, CHZ
Models provided with an electronic humidistat which can be adjusted from 60% to 90 % RH (relative humidity) and with a timer, adjustable between 2 and 20 minutes.

SPECIFIC RECOMMENDATIONS

  • If changing the settings of the fan you have to handle the controls located on the PCB. These adjusters are fragile and must be handled with care.
  • For humidity measurement is correct we need the fan is installed in an area where there is good air circulation.
  • Do not adjust the humidity outside the room where the vent should be    installed.

If the humidity level is consistently above 90% RH, the fan will not stop. OPERATION
Case 1: Automatic operation (Fig.8) Humidistat causes the extractor to operate automatically when the humidity level in the room is higher than the set level. The extractor will stop automatically when the humidity drops below the selected level and after the selected period set on the timer.
Installation Instruction

Case 2: Automatic operation as in case
1 with the facility to override the hygrostat by means of the light switch
(Fig.6) , when the humidity level in the room is lower than the selected level. In this case, the extractor continues to operate for the selected period set on the timer after the switch light has been switched off.
ATENTION: When the humidity rise above the selected value, the automatic option takes precedence over the manual and the unit cannot then be switched off using a switch.

SETTINGS

The fans are set to operate at 60% relative humidity and with 2 minutes run-on time. If the humidity in the room is lower than 60%, the fan will not turn on. If it is higher, the fan will operate until the humidity level drops below 60%RH and then runs for the length of time set by the timer. The desired humidity level and time delay are set by means of adjusters positioned on the printed circuit board (Fig. 9)

and accessible once the grille (1) has been removed. The humidity is set by the adjuster “% Hr”.

  • To reduce the humidity setting turn anticlockwise (min.60 %)
  • To increase the humidity setting turn clockwise (max. 90 %) The timer is set by the adjuster “t min.”
  • To reduce the run-on time, turn anticlockwise (min. 2 minutes).
  • To increase the run-on time, turn clockwise (max: 20 minutes).
  • ATTENTION: When the fan is on runon time phase, you must let it inish
    before a new setting.

Note: If the fan never turns on.

  • Humidity adjuster is not at its lowest setting. Turn anticlockwise the adjuster (do not force the adjuster) to the minimum setting.
  • The fan is itted in an area where there is no air low.
  • The humidity level in the room is below 60% RH If the fan never stops:
  • Humidity adjuster is not at its highest setting. Turn clockwise the adjuster (do not force the adjuster) to the maximum setting.
  • The humidity level in the room is above 90%

RH DECOR-100 CD and CDZ
Models provided with a PIR (passive infra-red) detector and adjustable “run on” timer (1 to 30 minutes). The unit starts automatically when a movement is detected with a maximum distance of 2 metres (Fig.8) and will continue to operate for the set period. The desired run-on time is selected by means of an adjuster positioned on the printed circuit board (Fig. 7) and accessible once the grille (1) has been removed:

  • To reduce the run-on time, turn anticlockwise (min. 1 minute)
  • To increase the run-on time, turn clockwise (max: 30 minutes).

USER INSTRUCTION

tact your National Soler & Palau contact. List in http://www.solerpalau.com
CLEANING AND MAINTENANCE
Important: disconnect from the mains supply before carrying out cleaning or maintenance The Fan needs only a periodical cleaning, using a cloth lightly impregnated with a soft detergent.

AFTER SALES SERVICE

We recommend you not to try to dismantle or remove any other parts than those mentioned as any tampering would automatically cancel the S&P guarantee. If you detect any fault, contact your S&P dealer.

PUTTING OUT OF SERVICE AND RECYCLING
EEC legislation and our consideration of future generations mean that we should always recycle materials where possible; please do not forget to deposit all packaging in the appropriate recycling bins. If your device is also labeled with this symbol, please take it to the nearest Waste Management Plant at the end of its servicable life.
S&P reserves the right to alter speciications without notice.