Soler Palau DECOR-100 Electric Exhaust Fan User Manual
- June 15, 2024
- Soler Palau
Table of Contents
Soler Palau DECOR-100 Electric Exhaust Fan User Manual
DECOR Axial Extractor Fans
This instruction manual contains important information and must be read
carefully by competent persons prior to any handling, transport, inspection or
installation of this product. Every care has been taken in the preparation of
the instructions and information; however, it is the responsibility of the
installer to ensure the system complies with relevant national and
international regulations, especially safety.
The manufacturer, Soler & Palau Sistema’s de Ventilations S.L.U. accepts no
responsibility for breakages, accidents or any inconvenience caused by failure
to comply with the instructions contained in this manual. The fans referred to
in this manual have been manufactured in accordance with rigorous quality
control and International standard ISO 9001. We recommend you to check the
following points when you receive this extractor:
- Make sure you have received the right model
- Make sure that the data on the nameplate are appropriate to your needs: voltage, frequency, speed, etc. Once the product has been installed, this manual to be retained by the end user.
SAFETY RECOMMENDATIONS
The installation must be carried out in accordance with current regulations in
each country. The installation must be carried out by a qualiied professional.
The electrical installation must incorporate an omnipolar switch with an
opening between contacts of at least 3 mm, appropriate for the load and
complying with current standards. In bathrooms, the device must be installed
outside the reach of any person taking a shower or a bath and.
the switch must be installed outside the bathroom. Do not use these fans in
explosive or corrosive atmospheres. If the DÉCOR DESIGN is working in a
kitchen where there is a boiler or any other kind of combustion device that
needs air to work, check that the air inlets to the kitchen are
suficient.
The extractor discharge cannot be connected to a conduit for the evacuation of
smoke from devices worked by gas or any other fuel. In the event of
considerable humidity, you are advised to install the discharge conduit
horizontally, with a slight outwards slant.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of
the appliance in a safe way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
INSTALLATION FIG.1
IMPORTANT: Before installing and wiring the unit, ensure that the main supply is switched off.
- Protection grille
- Fixing screw
- 3. Connection terminals
- Outlet with backdraught shutter
- Cable entry
The DECOR can either discharge directly to the outside or via an individual or
central ducting system (see Fig. 2)
.
The unit can be mounted on the wall or ceiling using the 4 rubber blocksand
the screws provided. Drill a hole in chosen position in the wall or ceiling
of: (Fig.1). I
f the unit is to be installed with individual ducting, use a standard duct:
-
* DECOR-100: 100 mm
- DECOR-200: 125 mm
- DECOR-300: 150-160 mm
Loosen the screw (2) , which holds the grille in place (1) and remove
the grille. Ensure that there are no obstructions to the airlow and that the
impeller turns freely.
Fix the extractor to the wall in such a way that it is not distorted in order
to avoid noise generation or problems with the rotation of the impeller. Make
sure that the back draught shutter opens freely and has not being damaged in
transit.
Introduce the mains cable through one of the cable point (5) and ix it to
the wall so that the ixing screw (2) is above. Connect the electrical
wiring as set out below and then mount the protection grille (1) and
tighten the screw (2).
ELECTRICAL CONNECTION
This appliance is considered to
be suitable for use
in countries having a warm
damp equable climate as specified in IEC 60721-2-1. It may also
be used in other countries.
The DECOR-100 is an extractor designed for a single phase supply, with voltage
and frequency as indicated on the rating plate of the unit. The units are
manufactured with double electrical insulation (Class II) and therefore they
do not need an earth connection. In addition to the switch shown in the
installation drawing/diagram, there must be an All Pole switch in the ixed
wiring with a contact opening of min 3 mm.
The electrical cable must enter the DECOR-100 through one of the cable point
(5). Once the cable has been introduced proceed using the electrical wiring
diagram applicable to the selected model.
DECOR S, C, SZ, CZ
These models use the following diagrams: Fig.3:
Fan operating through the light switch. Fig.4 :
Fan operating through an independent switch.
DECOR R, CR, RZ, CRZ
These models are itted with an adjustable timer. The timer enables the fan to
continue running for the selected period after the switch has been turned off.
Fig.5 :
Fan operating through an independent switch. Fig.6:
Fan operating through a light
switch.
The desired run-on time is selected by means of an adjuster positioned on the printed circuit board (ig. 7) and accessible once the grille (1) has been removed:
- To reduce the run-on time, turn anticlockwise (min. 1 minute).
- To increase the run-on time, turn clockwise (max: 30 minutes).
DECOR H, CH, HZ, CHZ
Models provided with an electronic humidistat which can be adjusted from
60% to 90 % RH (relative humidity) and with a timer, adjustable between 2 and
20 minutes.
SPECIFIC RECOMMENDATIONS
- If changing the settings of the fan you have to handle the controls located on the PCB. These adjusters are fragile and must be handled with care.
- For humidity measurement is correct we need the fan is installed in an area where there is good air circulation.
- Do not adjust the humidity outside the room where the vent should be installed.
If the humidity level is consistently above 90% RH, the fan will not stop.
OPERATION
Case 1: Automatic operation (Fig.8) Humidistat causes the extractor
to operate automatically when the humidity level in the room is higher than
the set level. The extractor will stop automatically when the humidity drops
below the selected level and after the selected period set on the timer.
Case 2: Automatic operation as in case
1 with the facility to override the hygrostat by means of the light switch
(Fig.6) , when the humidity level in the room is lower than the selected
level. In this case, the extractor continues to operate for the selected
period set on the timer after the switch light has been switched off.
ATENTION: When the humidity rise above the selected value, the automatic
option takes precedence over the manual and the unit cannot then be switched
off using a switch.
SETTINGS
The fans are set to operate at 60% relative humidity and with 2 minutes run-on
time. If the humidity in the room is lower than 60%, the fan will not turn on.
If it is higher, the fan will operate until the humidity level drops below
60%RH and then runs for the length of time set by the timer. The desired
humidity level and time delay are set by means of adjusters positioned on the
printed circuit board (Fig. 9)
and accessible once the grille (1) has been removed. The humidity is set by
the adjuster “% Hr”.
- To reduce the humidity setting turn anticlockwise (min.60 %)
- To increase the humidity setting turn clockwise (max. 90 %) The timer is set by the adjuster “t min.”
- To reduce the run-on time, turn anticlockwise (min. 2 minutes).
- To increase the run-on time, turn clockwise (max: 20 minutes).
- ATTENTION: When the fan is on runon time phase, you must let it inish
before a new setting.
Note: If the fan never turns on.
- Humidity adjuster is not at its lowest setting. Turn anticlockwise the adjuster (do not force the adjuster) to the minimum setting.
- The fan is itted in an area where there is no air low.
- The humidity level in the room is below 60% RH If the fan never stops:
- Humidity adjuster is not at its highest setting. Turn clockwise the adjuster (do not force the adjuster) to the maximum setting.
- The humidity level in the room is above 90%
RH DECOR-100 CD and CDZ
Models provided with a PIR (passive infra-red) detector and adjustable “run
on” timer (1 to 30 minutes). The unit starts automatically when a movement is
detected with a maximum distance of 2 metres (Fig.8) and will continue to
operate for the set period. The desired run-on time is selected by means of an
adjuster positioned on the printed circuit board (Fig. 7) and accessible
once the grille (1) has been removed:
- To reduce the run-on time, turn anticlockwise (min. 1 minute)
- To increase the run-on time, turn clockwise (max: 30 minutes).
USER INSTRUCTION
tact your National Soler & Palau contact. List in http://www.solerpalau.com
CLEANING AND MAINTENANCE
Important: disconnect from the mains supply before carrying out cleaning or
maintenance The Fan needs only a periodical cleaning, using a cloth lightly
impregnated with a soft detergent.
AFTER SALES SERVICE
We recommend you not to try to dismantle or remove any other parts than those
mentioned as any tampering would automatically cancel the S&P guarantee. If
you detect any fault, contact your S&P dealer.
PUTTING OUT OF SERVICE AND RECYCLING
EEC legislation and our consideration of future generations mean that we
should always recycle materials where possible; please do not forget to
deposit all packaging in the appropriate recycling bins. If your device is
also labeled with this symbol, please take it to the nearest Waste Management
Plant at the end of its servicable life.
S&P reserves the right to alter speciications without notice.