DOMEO 210 FL 3V EU Ventilation Unit

The DOMEO 210 FL 3V EU is a ventilation unit that can be disassembled and its components can be ecologically disposed of according to EU 1253/2014 regulations. The disassembly process involves separating the components into material fractions and larger components.

Product Usage Instructions

Safety Instructions: It is important to follow safety instructions while disassembling the DOMEO 210 FL 3V EU.
Please refer to the safety instructions provided in the user manual.

Parts to be Disassembled

The following parts should be disassembled:

  • Filter cover (plastic) and filters
  • 4 air connections
  • Front cover (plastic)
  • Heat exchanger
  • 2 fan covers
  • 2 fans (motor + fan assembly)
  • By-pass
  • Main supply wire
  • Controller wire
  • 2 temperature sensors
  • Main PCB (electronics)
  • Wall support (metal)
  • By-pass back cover
  • By-pass damper

Procedure and Tools Needed for Disassembly

The following tools are required for disassembling the ventilation unit:

  • Scissors
  • Nippers
  • Pliers
  • Phillips screwdriver
  • Allen screwdriver

Follow the steps below for disassembling the DOMEO 210 FL 3V EU:

  1. Remove the filter cover (plastic) and filters by hand. Dispose of the filters in a general waste bin.
  2. Remove the 4 air connections by hand.
  3. Remove the two bottom screws by a Phillips screwdriver and remove the front cover (plastic) by hand.
  4. Pull the heat exchanger and separate it from the main body. Cut the heat exchanger’s grip using scissors and remove the metal supports by hand.
  5. Remove the two fan covers. Disconnect the motors from the main PCB and remove the two fans by hand, pulling firmly from the main body. Use a Phillips screwdriver to unscrew the two screws that join the scroll of the fan. Then, unscrew the three screws that unite the scroll to the motor.
  6. Disconnect the by-pass from the main PCB. Disconnect the main supply wire and the controller wire as well as the 2 temperature sensors.
  7. The main PCB (electronics) is fixed to the main body by means of 4 screws. Use a Phillips screwdriver to remove the PCB.
  8. Unscrew the two back screws by an Allen screwdriver to be able to remove the wall support.
  9. Unscrew the last two screws remaining in the down face in order to remove the last metal pieces from the main body. The main body is made entirely of plastic.

Disposal / Recycling

Disposal must be carried out professionally and in an environmentally friendly way in accordance with the respective national legal stipulations. Separate materials by type and, if necessary, commission a specialist company with the waste disposal.

General notes

Instructions manual for disassembly and ecologically disposal of components of ventilation units according to EU 1253/2014.
This manual includes the disassembly of the ventilation unit into material fractions and larger components.

Safety instructions

Attention!

  • Observe the assembly instructions of the product and ensure compliance with all safety specifications.
  • Cut off the electrical supply before any work begins.

Parts to be disassembled

  • The following parts should be disassembled:
    • Counter-flow heat exchanger
    • Unit body (large plastic part)
    • Panels/covers
    • Control equipment (wiring and electronic components)
    • Supply fan
    • Extract fan
    • Supply motor
    • Extract motor
    • Air connections
    • Filters
    • By-pass motor
    • Small metal pieces (supports and screws)

Procedure and tools needed for disassembly

The following tools are required for disassembly of the ventilation unit: Scissors, Nippers, Pliers, Phillips screwdriver, allen screwdriver.

  1. Remove filter cover (plastic) and filters by hand. Filters should be put on general waste bin.
  2. emove the 4 air connections by hand.
  3. Remove the two bottom screws by a phillips screw driver and remove the front cover (plastic) by hand.
  4. Pull from the heat exchanger and separate it from the main body.
  5. Remove the two fan covers. Disconnect the motors from the main PCB and remove the two fans by hand, pulling firmly from the main body. The disassembly of motor-fans will be detailed in next steps. Cut the wiring.
  6. Disconnect the by-pass from the main PCB.
  7. Disconnect the main supply wire and the controller wire as well as the 2 temperature sensors.
  8. The main PCB (electronics) is fixed to the main body by means of 4 screws. Use a phillips screwdriver to remove the PCB.
  9. Unscrew the two back screws by an allen screw driven to be able to remove the wall support.
  10. The main PCB (electronics) is fixed to the main body by means of 4 screws. Use a phillips screwdriver to remove the PCB.

Disassembly of heat exchanger
Cut the heat exchanger’s grip using scissors and remove the metal supports by hand

Disassembly of fan-motor
Use a phillips screwdriver to unscrew the two screws that join the scroll of the fan. Then, unscrew the three screws that unite the scroll to the motor.

Disassembly of main body
Unscrew the last two screws remainint in the down face in order to remove the lasts metal pieces from the main body. The main body is made entirely in plastic.

Disposal/recycling
Disposal must be carried out professionally and in an environmentally friendly way in accordance with the respective national legal stipulations. Separate materials by type and, if necessary, commission a specialist company with the waste disposal.

www.solerpalau.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals