Product Information

Specifications

  • Model: LOP-200-12, LOP-200-15, LOP-200-18, LOP-200-24, LOP-200-27, LOP-200-36, LOP-200-48, LOP-200-54
  • DC Voltage: 12V, 15V, 18V, 24V, 27V, 36V, 48V, 54V
  • Peak Current (3sec.): 25A, 20A, 16.7A, 12.5A, 11.1A, 8.3A, 6.3A, 5.6A
  • Current (10.98CFM): 16.7A, 13.4A, 11.1A, 8.4A, 7.5A, 5.6A, 4.2A, 3.8A
  • Convection Current: 11.7A, 9.4A, 7.8A, 5.9A, 5.3A, 3.9A, 3.0A, 2.7A
  • Rated Power : Peak (3sec.) – 300W, Convection – 200.4W
  • Output Ripple & Noise: Maximum of 120mVp-p
  • Voltage Adjustment Range (Main Output): 1 1.4~12.6V
  • Line Regulation: 250mVp-p
  • Load Regulation : 250mVp-p
  • Setup, Rise Time : 1000ms, 30ms/230VAC; 1500ms, 30ms/115VAC at full load
  • Hold Up Time (Typ.) : 16ms@140W load, 8ms@200W load
  • Voltage Range: 80 ~ 264VAC, 113 ~ 370VDC
  • Frequency Range: 47 ~ 63Hz
  • Power Factor: PF > 0.95/230VAC, PF > 0.98/115VAC at full load
  • Input Efficiency (Typ.): 9 3%, 93.5%, 94%, 94%, 94%, 94%, 94%, 94%
  • AC Current (Typ.): 2.5A/115VAC, 1A/230VAC
  • Inrush Current (Typ.) : Cold Start – 40A/115VAC, 80A/230VAC
  • L eakage Current: Earth leakage current < 500A(rms) @ 264VAC, touch current < 70A(rms) @ 264VAC
  • Overload Protection: 105 ~ 150% rated output power, Hiccup after 3 sec, recovers automatically after fault condition is removed
  • Over Voltage Protection: Shut down o/p voltage, re-power on to recover
  • Over Temperature Protection: Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover
  • External Fan Supply: 12V @ 0.5A for driving a fan / 12V @ 0.1A without fan; (10.98CFM)
  • Working Temper ature: -40 ~ +80°C (Refer to Derating Curve)
  • Working Humidity: 20 ~ 90% RH non-condensing
  • Storage Temperature, Humidity : -40 ~ +85°C, 10 ~ 95% RH non-condensing
  • Temperature Coefficient: Vibration – 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
  • Safety Standards: C B IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1; TUV BS EN/EN62368-1, BS EN/EN60335-1, BS
  • EN/EN61558-1/-2-16, BS EN/EN60601-1(3.2 Version); UL UL62368-1,
  • ANSI / AAMI ES60601-1(3.2 Version); CCC GB4943.1; RCM AS/NZS 61558-1/-2-16; EAC TPTC 004 approved
  • Isolation Resistance: Primary-Secondary: 2xMOPP, Primary-Earth:
  • 1xMOPP, Secondary-Eart h: 1xMOPP
  • Over Voltage Category: IEC/EN 61558-1/-2-16(OVC, altitude up to 2000M), IEC/EN/UL 62368-1 (OVC, altitude up to 5000M)
  • Over Voltage Category: IEC/EN 60335-1 (OVC, altitude up to 5000M), IEC/EN 60601-1 (OVC, altitude up to 4000M)

Product Usage Instructions

Installation

  • Ensure that the input voltage is within the specified range of 80 ~ 264VAC or 113 ~ 370VDC.
  • Connect the DC output to your device using the appropriate connectors.
  • If using an external fan, connect the fan to the external fan supply as specified.
  • Ensure proper grounding of the power supply.

Operation

  • Turn on the power supply using the designated power switch.
  • Monitor the output voltage and adjust if necessary within the specified voltage adjustment range.
  • Ensure that the load does not exceed the rated output power to prevent overload.
  • In case of an overvoltage or over-temperature condition, the power supply will automatically shut down. Remove the fault condition and re-power on to recover.

Maintenance

  • Regularly inspect the power supply for any signs of damage or wear.
  • Clean any dust or debris that may accumulate on the power supply
  • Ensure proper ventilation to prevent overheating.

FAQ

  1. What is the maximum rated power of the LOP-200 series power supply?
    The maximum rated power of the LOP-200 series power supply is 300W.

  2. What is the input voltage range for the LOP-200 series power supply?
    The input voltage range for the LOP-200 series power supply is 80 ~ 264VAC or 113 ~ 370VDC.

  3. How does the power supply protect against overvoltage and over-temperature conditions?
    The power supply will automatically shut down the output voltage in case of overvoltage or over-temperature conditions. It will recover automatically once the fault condition is removed or the temperature goes down.

200W 4″×2″ Low Profile Open Frame Power Supply LOP-200 series

MEAN-WELL-LOP-200-Series-200W-4-Inch-×-2-Inch-Low-Profile-Open -Frame-Power-
Supply-IMAGE-1

Features

  • MEAN WELL Patent Number : ZL 202223277512.1
  • 4″×2″ compact size with low profile (25.4mm)|
  • 80~264Vac input with PFC, No load power consumption<0.5W
  • Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16)|
  • 150%peak load @ 3s
  • 140W convection, 200W with FAN 10.98CFM forced-cooled
  • Suitable for Class I or Class II installations
  • Over voltage category I (OVC Ill)
  • -40 ~ +80°C wide range operation temperature
  • High efficiency up to 94%
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Extremely low leakage current
  • Operating altitude up to 5000 meters
  • Built-in 12V/0.5A for external FAN
  • 3 veers warranty

Description

  • LOP-200 is a 200W highly reliable green PCB type low profile power supply with a high power density (25W/in’) on the 4″ by 2″ footprint.
  • It accepts 80~264VAC input and offers various output voltages between 12V and 54V.
  • The working efficiency is up to 94% and the extremely low no load power consumption is down below 0.5W. LOP-200 is able to be used for both Class I (with FG) and Class II (no FG) system design. LOP-200 is equipped with complete protection functions;
  • It is complied with the international safety regulations such as IEC/BS EN/EN/UL62368-1,IEC/BS EN/EN60335-1,IEC/BS EN/EN61558-1/-2-16, IEC/BS EN/EN60601-1.LOP-200 serves as a high price-to-performance power supply solution for various industrial applications.
  • The extremely low leakage current is less than 500 mA.
  • In addition, it conforms to the international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.

Model EncodingMEAN-WELL-LOP-200-Series-200W-4-Inch-×-2-Inch-Low-
Profile-Open -Frame-Power-Supply-IMAGE-11

MEAN-WELL-LOP-200-Series-200W-4-Inch-×-2-Inch-Low-Profile-Open -Frame-Power-
Supply-IMAGE-2

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipment’s or apparatus
  • Power sourcing equipment of PoE
  • Medical devices

GTIN CODE

SPECIFICATIONS

MODEL| LOP-200-12| LOP-200-15| LOP-200-18| LOP-200-24| LOP-200-27| LOP-200-36| LOP-200-48| LOP-200-54
---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 18V| 24V| 27V| 36V| 48V| 54V
CURRENT| Peak(3sec.)| 25A| 20A| 16.7A| 12.5A| 11.1A| 8.3A| 6.3A| 5.6A
10.98CF M| 16.7A| 13.4A| 11.1A| 8.4A| 7.5A| 5.6A| 4.2A| 3.8A
Convection| 11.7A| 9.4A| 7.8A| 5.9A| 5.3A| 3.9A| 3.0A| 2.7A
RATED POWER| Peak(3sec.)| 300W| 300W| 300.6W| 300W| 299.7W| 298.8W| 302.4W| 302.4W
10.98CF M| 200.4W| 201W| 199.8W| 201.6W| 202.5W| 201.6W| 201.6W| 205.2W
Convection| 140.4W| 141W| 140.4W| 141.6W| 143.1W| 140.4W| 144W| 145.8W
RIPPLE & NOISE (max.)
Note.2| 120mVp-p| 150mVp-p| 180mVp-p| 200mVp-p| 200mVp-p| 250mVp-p| 250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE

(MAIN OUTPUT)

| 11.4~12.6V| 14.3~15.8V| 17.1~18.9V| 22.8~25.2V| 25.6 ~ 29V| 34.2 ~37.8V| 45.6 ~50.4V| 52 ~58V
VOLTAGE TOLERANCE
Note.3| ±3.0%| ±3.0%| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 1000ms, 30ms/230VAC          1500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 16ms@140W load , 8ms@200W load
INPUT| VOLTAGE RANGE Note.4| 80 ~ 264VAC         113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 93%| 93%| 93.5%| 94%| 94%| 94%| 94%| 94%
AC CURRENT (Typ.)| 2.5A/115VAC         1A/230VAC
INRUSH CURRENT (Typ.)| COLD START 40A/115VAC         80A/230VAC
LEAKAGE CURRENT| Earth leakage current < 500μA(rms) @ 264VAC , touch current < 70μA(rms) @ 264VAC
PROTECTION| OVERLOAD| 105 ~ 150% rated output power, Protection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed
OVER VOLTAGE| 13.2 ~ 15.6V| 16.5 ~ 19.5V| 19.8 ~ 23.4V| 26.4 ~ 31.2V| 29.7 ~ 35.1V| 39.6 ~ 46.8V| 52.8 ~ 62.4V| 59.4 ~ 67.5V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover
FUNCTION| EXTERNAL FAN SUPPLY| 12V@0.5A for driving a fan / 12V@0.1A without fan ; (10.98CFM) tolerance -20% ~ +15% at main output 20% rated current
ENVIRONMENT| WORKING TEMP.| -40 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

MEAN-WELL-LOP-200-Series-200W-4-Inch-×-2-Inch-Low-Profile-Open -Frame-Power-
Supply-IMAGE-12 MEAN-WELL-LOP-200-Series-200W-4-Inch-×-2-Inch-Low-Profile-Open
-Frame-Power-Supply-IMAGE-13

NOTE:

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1f & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  6. Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

BLOCK DIAGRAM

MEAN-WELL-LOP-200-Series-200W-4-Inch-×-2-Inch-Low-Profile-Open -Frame-Power-
Supply-IMAGE-3

DIRATING CURVE

MEAN-WELL-LOP-200-Series-200W-4-Inch-×-2-Inch-Low-Profile-Open -Frame-Power-
Supply-IMAGE-4

Cooling Max. Output Power
Free air convection 140W
Force-cooled with external Fan 200W

Output Derating VS Input Voltage

Mechanical Specification

MEAN-VWELL-LOP-200-Series-200W-4-Inch-×-2-Inch-Low-Profile-Open -Frame-
Power-Supply-IMAGE-5 MEAN-VWELL-LOP-200-Series-200W-4-Inch-×-2-Inch-Low-Profile-Open
-Frame-Power-Supply-IMAGE-5

AC Input Connector (CN1) : JST B3P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/L JST VHR or equivalent JST SVH-21T P1.1 or  equivalent
2 No Pin
3 AC/N

DC Output Connector (CN2) : JST B6P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1,2,3 +V JST VHR  or equivalent JST SVH-21T-P1.1 or equivalent
4,5,6 -V

FAN Connector(CN101) : JSTB2B-PH-K-S or equivalent

Pin No. Assignment Mating Housing Terminal
1 +12V JST PHR-2 or equivalent JST SPH 002T P0.5S or equivalent
2 DC COM

Note

  • Class Ⅰ System: Mounting holes marked with have to be connected to safety earth.
  • Class Ⅱ System: Unnecessary to connect with safety earth.

Installation Manual