MEAN WELL LOP-200 Series 200W 4 Inch × 2 Inch Low Profile Open Frame Power Supply Owner’s Manual
- June 15, 2024
- MEAN WELL
Table of Contents
MEAN WELL LOP-200 Series 200W 4 Inch × 2 Inch Low Profile Open Frame
Power Supply
Product Information
Specifications
- Model: LOP-200-12, LOP-200-15, LOP-200-18, LOP-200-24, LOP-200-27, LOP-200-36, LOP-200-48, LOP-200-54
- DC Voltage: 12V, 15V, 18V, 24V, 27V, 36V, 48V, 54V
- Peak Current (3sec.): 25A, 20A, 16.7A, 12.5A, 11.1A, 8.3A, 6.3A, 5.6A
- Current (10.98CFM): 16.7A, 13.4A, 11.1A, 8.4A, 7.5A, 5.6A, 4.2A, 3.8A
- Convection Current: 11.7A, 9.4A, 7.8A, 5.9A, 5.3A, 3.9A, 3.0A, 2.7A
- Rated Power : Peak (3sec.) – 300W, Convection – 200.4W
- Output Ripple & Noise: Maximum of 120mVp-p
- Voltage Adjustment Range (Main Output): 1 1.4~12.6V
- Line Regulation: 250mVp-p
- Load Regulation : 250mVp-p
- Setup, Rise Time : 1000ms, 30ms/230VAC; 1500ms, 30ms/115VAC at full load
- Hold Up Time (Typ.) : 16ms@140W load, 8ms@200W load
- Voltage Range: 80 ~ 264VAC, 113 ~ 370VDC
- Frequency Range: 47 ~ 63Hz
- Power Factor: PF > 0.95/230VAC, PF > 0.98/115VAC at full load
- Input Efficiency (Typ.): 9 3%, 93.5%, 94%, 94%, 94%, 94%, 94%, 94%
- AC Current (Typ.): 2.5A/115VAC, 1A/230VAC
- Inrush Current (Typ.) : Cold Start – 40A/115VAC, 80A/230VAC
- L eakage Current: Earth leakage current < 500A(rms) @ 264VAC, touch current < 70A(rms) @ 264VAC
- Overload Protection: 105 ~ 150% rated output power, Hiccup after 3 sec, recovers automatically after fault condition is removed
- Over Voltage Protection: Shut down o/p voltage, re-power on to recover
- Over Temperature Protection: Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover
- External Fan Supply: 12V @ 0.5A for driving a fan / 12V @ 0.1A without fan; (10.98CFM)
- Working Temper ature: -40 ~ +80°C (Refer to Derating Curve)
- Working Humidity: 20 ~ 90% RH non-condensing
- Storage Temperature, Humidity : -40 ~ +85°C, 10 ~ 95% RH non-condensing
- Temperature Coefficient: Vibration – 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
- Safety Standards: C B IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1; TUV BS EN/EN62368-1, BS EN/EN60335-1, BS
- EN/EN61558-1/-2-16, BS EN/EN60601-1(3.2 Version); UL UL62368-1,
- ANSI / AAMI ES60601-1(3.2 Version); CCC GB4943.1; RCM AS/NZS 61558-1/-2-16; EAC TPTC 004 approved
- Isolation Resistance: Primary-Secondary: 2xMOPP, Primary-Earth:
- 1xMOPP, Secondary-Eart h: 1xMOPP
- Over Voltage Category: IEC/EN 61558-1/-2-16(OVC, altitude up to 2000M), IEC/EN/UL 62368-1 (OVC, altitude up to 5000M)
- Over Voltage Category: IEC/EN 60335-1 (OVC, altitude up to 5000M), IEC/EN 60601-1 (OVC, altitude up to 4000M)
Product Usage Instructions
Installation
- Ensure that the input voltage is within the specified range of 80 ~ 264VAC or 113 ~ 370VDC.
- Connect the DC output to your device using the appropriate connectors.
- If using an external fan, connect the fan to the external fan supply as specified.
- Ensure proper grounding of the power supply.
Operation
- Turn on the power supply using the designated power switch.
- Monitor the output voltage and adjust if necessary within the specified voltage adjustment range.
- Ensure that the load does not exceed the rated output power to prevent overload.
- In case of an overvoltage or over-temperature condition, the power supply will automatically shut down. Remove the fault condition and re-power on to recover.
Maintenance
- Regularly inspect the power supply for any signs of damage or wear.
- Clean any dust or debris that may accumulate on the power supply
- Ensure proper ventilation to prevent overheating.
FAQ
-
What is the maximum rated power of the LOP-200 series power supply?
The maximum rated power of the LOP-200 series power supply is 300W. -
What is the input voltage range for the LOP-200 series power supply?
The input voltage range for the LOP-200 series power supply is 80 ~ 264VAC or 113 ~ 370VDC. -
How does the power supply protect against overvoltage and over-temperature conditions?
The power supply will automatically shut down the output voltage in case of overvoltage or over-temperature conditions. It will recover automatically once the fault condition is removed or the temperature goes down.
200W 4″×2″ Low Profile Open Frame Power Supply LOP-200 series
Features
- MEAN WELL Patent Number : ZL 202223277512.1
- 4″×2″ compact size with low profile (25.4mm)|
- 80~264Vac input with PFC, No load power consumption<0.5W
- Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16)|
- 150%peak load @ 3s
- 140W convection, 200W with FAN 10.98CFM forced-cooled
- Suitable for Class I or Class II installations
- Over voltage category I (OVC Ill)
- -40 ~ +80°C wide range operation temperature
- High efficiency up to 94%
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Extremely low leakage current
- Operating altitude up to 5000 meters
- Built-in 12V/0.5A for external FAN
- 3 veers warranty
Description
- LOP-200 is a 200W highly reliable green PCB type low profile power supply with a high power density (25W/in’) on the 4″ by 2″ footprint.
- It accepts 80~264VAC input and offers various output voltages between 12V and 54V.
- The working efficiency is up to 94% and the extremely low no load power consumption is down below 0.5W. LOP-200 is able to be used for both Class I (with FG) and Class II (no FG) system design. LOP-200 is equipped with complete protection functions;
- It is complied with the international safety regulations such as IEC/BS EN/EN/UL62368-1,IEC/BS EN/EN60335-1,IEC/BS EN/EN61558-1/-2-16, IEC/BS EN/EN60601-1.LOP-200 serves as a high price-to-performance power supply solution for various industrial applications.
- The extremely low leakage current is less than 500 mA.
- In addition, it conforms to the international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.
Model Encoding
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipment’s or apparatus
- Power sourcing equipment of PoE
- Medical devices
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATIONS
MODEL| LOP-200-12| LOP-200-15| LOP-200-18|
LOP-200-24| LOP-200-27| LOP-200-36| LOP-200-48|
LOP-200-54
---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 18V| 24V| 27V| 36V| 48V| 54V
CURRENT| Peak(3sec.)| 25A| 20A| 16.7A| 12.5A| 11.1A| 8.3A| 6.3A|
5.6A
10.98CF M| 16.7A| 13.4A| 11.1A| 8.4A| 7.5A| 5.6A| 4.2A| 3.8A
Convection| 11.7A| 9.4A| 7.8A| 5.9A| 5.3A| 3.9A| 3.0A| 2.7A
RATED POWER| Peak(3sec.)| 300W| 300W| 300.6W| 300W| 299.7W|
298.8W| 302.4W| 302.4W
10.98CF M| 200.4W| 201W| 199.8W| 201.6W| 202.5W| 201.6W| 201.6W|
205.2W
Convection| 140.4W| 141W| 140.4W| 141.6W| 143.1W| 140.4W| 144W| 145.8W
RIPPLE & NOISE (max.)
Note.2| 120mVp-p| 150mVp-p| 180mVp-p| 200mVp-p| 200mVp-p| 250mVp-p|
250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE
(MAIN OUTPUT)
| 11.4~12.6V| 14.3~15.8V| 17.1~18.9V| 22.8~25.2V| 25.6 ~ 29V| 34.2 ~37.8V|
45.6 ~50.4V| 52 ~58V
VOLTAGE TOLERANCE
Note.3| ±3.0%| ±3.0%| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at
full load
HOLD UP TIME (Typ.)| 16ms@140W load , 8ms@200W load
INPUT| VOLTAGE RANGE Note.4| 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 93%| 93%| 93.5%| 94%| 94%| 94%| 94%| 94%
AC CURRENT (Typ.)| 2.5A/115VAC 1A/230VAC
INRUSH CURRENT (Typ.)| COLD START 40A/115VAC 80A/230VAC
LEAKAGE CURRENT| Earth leakage current < 500μA(rms) @ 264VAC , touch
current < 70μA(rms) @ 264VAC
PROTECTION| OVERLOAD| 105 ~ 150% rated output power, Protection
type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition
is removed
OVER VOLTAGE| 13.2 ~ 15.6V| 16.5 ~ 19.5V| 19.8 ~ 23.4V| 26.4 ~ 31.2V|
29.7 ~ 35.1V| 39.6 ~ 46.8V| 52.8 ~ 62.4V| 59.4 ~ 67.5V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, recovers
automatically after temperature goes down or re-power on to recover
FUNCTION| EXTERNAL FAN SUPPLY| 12V@0.5A for driving a fan /
12V@0.1A without fan ; (10.98CFM) tolerance -20% ~ +15% at main output 20%
rated current
ENVIRONMENT| WORKING TEMP.| -40 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
NOTE:
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1f & 47uf parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltages. Please check the derating curve for more details.
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
- Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
BLOCK DIAGRAM
DIRATING CURVE
Cooling | Max. Output Power |
---|---|
Free air convection | 140W |
Force-cooled with external Fan | 200W |
Output Derating VS Input Voltage
Mechanical Specification
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | AC/L | JST VHR or equivalent | JST SVH-21T P1.1 or equivalent |
2 | No Pin | ||
3 | AC/N |
DC Output Connector (CN2) : JST B6P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1,2,3 | +V | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
4,5,6 | -V |
FAN Connector(CN101) : JSTB2B-PH-K-S or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | +12V | JST PHR-2 or equivalent | JST SPH 002T P0.5S or equivalent |
2 | DC COM |
Note
- Class Ⅰ System: Mounting holes marked with have to be connected to safety earth.
- Class Ⅱ System: Unnecessary to connect with safety earth.
Installation Manual
Please refer t o : http://www.meanwell.com/webnet/search/InstallationSearch.html
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>