REZNOR EHA-TSL Forced Air Architectural Wall Heater User Guide
- June 15, 2024
- Reznor
Table of Contents
REZNOR EHA-TSL Forced Air Architectural Wall Heater
Technical Specifications
- Model : EHA
- Type : Indoor Commercial/Residential Forced-Air Electric Wall-Mounted Architectural Heater
TECHNICAL SPECIFICATIONS FOR MODEL EHA
INDOOR COMMERCIAL/RESIDENTIAL FORCED-AIR ELECTRIC WALL-MOUNTED ARCHITECTURAL HEATER
- In keeping with our policy of continuous product improvement, we reserve the right to alter, at any time, the design, construction, dimensions, weights, etc., of equipment information shown here.
Unit Sizes
The heater is available in the following unit sizes:
- kW
- kW
- kW
- kW
- kW
Features
- Voltage/phase options: 120/1, 208/1, 240/1, 277/1, and 480/1
- White or almond epoxy/polyester powder paint finish
- Extruded aluminum grill, 1/8-inch (3.2-mm) thickness
- Botton air outlet
- High-temperature limit control with automatic reset
- actory-lubricated closed fan motor (fan delay purges residual heat)
- Durable tubular heating element with fins
- Up to three units may be mounted side-by-side
- Built-in tamper-proof thermostat or control relay
NOTE : A thermostat is not included in a heater with a factory-installed relay. Any remote thermostat or relay must be connected to the heater control terminal block.
Factory-Installed Options
Option | Description |
---|---|
AK1E | Voltage/phase 120/1 (not available for unit sizes 2–5) |
AK2 | Voltage/phase 208/1 (not available for unit sizes 1 and 3) |
AK3E | Voltage/phase 240/1 |
AK4 | Voltage/phase 277/1 |
AK9E | Voltage/phase 480/1 |
BA14 | Disconnect switch, 600V, three-pole, 40A |
BA21 | Disconnect switch, up to 277V, double-pole, 20A |
BT1 | 24V control relay with transformer |
HK1 | White cabinet color |
HK2 | Almond cabinet color |
IC15 | Internal tamper-proof single-stage thermostat |
Field-Installed Options
Option | Description |
---|---|
HY6 | Color-matched surface mounting box (required if unit is flush-mounted) |
Technical Data
Parameter | Unit of Measure | Unit Size (kW) |
---|---|---|
1 | 2 | 3 |
Heating capacity | watt | 1500 |
BTUh | 5125 | 6825 |
Airflow | CFM | 160 |
Sound level, single unit | **** |
dBa
| 55
Sound level, double unit| 58
Sound level, triple unit| 61
Required Clearances
The required minimum clearance from the floor and adjacent walls is 10 inches (25.4 mm).
Dimensions
Unit Size (kW)
1| 2| 3| 4| 5
Height × Width (Inches (mm))
22-3/4 (578) × 16-1/16 (408)
Shipping Weight
Unit Size (kW)
1| 2| 3| 4| 5
Pounds (kg)
24 (10 .9)
DANGER
- This heater has hot parts inside. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces.
- Do not operate any heater after it malfunctions. Disconnect power at the service panel and have the heater inspected by a reputable electrician before reusing.
- Do not use outdoors.
- Do not insert or allow foreign objects to enter any heater opening as this may cause electrical shock, fire, or damage to the heater.
- To prevent a possible fire, do not block air intakes or exhaust in any way whatsoever.
- Use this heater only as recommended by the manufacturer. Any other use may cause electrical shock, fire, or damage to the heater.
For more information on Reznor HVAC products
- Contact your local Reznor representative at 1-800-695-1901
- Refer to the manuals and additional consumer materials found at www.reznorhvac.com