MOXA EDS-G308 Series Ether Device Switch Installation Guide
- June 4, 2024
- MOXA
Table of Contents
© 2021 Moxa Inc. All rights reserved.
EDS-G308 Series
Quick Installation Guide
Moxa EtherDevice Switch
Version 6.3, June 2021
Technical Support Contact Information
www.moxa.com/support
Overview
The EDS-G308 Series is equipped with 8 Gigabit Ethernet ports and up to 2 fiber optic ports, making it ideal for applications that demand high bandwidth. The EDS-G308 series provides an economical solution for your industrial Gigabit Ethernet connection, and the built-in relay warning function alerts maintainers when power failures or port breaks occur. In addition, the 4-pin DIP switches can be used to configure the following features: broadcast storm protection (BSP), jumbo frame rate (Jumbo), and IEEE 802.3az energy saving. The EDS-G308 series includes 2 models: one with an operating temperature range of -10 to 60°C, and the other one with an extended operating temperature range of -40 to 75°C. These 2 models have passed a 100% burn-in test to ensure that they fulfill the special needs of industrial automation control. The EDS-G308 series can be easily installed with DIN-Rail mounting as well as distribution boxes.
NOTE Throughout this Hardware Installation Guide, we use EDS as an abbreviation for Moxa EtherDevice Switch: EDS = Moxa EtherDevice Switch
Package Checklist
Your EDS is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance.
- Moxa EtherDevice™ Switch
- Quick installation guide (printed)
- Warranty card
- Protective caps for unused ports
Features
High-Performance Network Switching Technology
- 10/100/1000BaseT(X) (RJ45), auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection, 100/1000 BaseSFP slot.
- IEEE 802.3/802.3u/802.3ab/802.3z/802.3x.
- Store and Forward switching process type, 8K MAC address entries.
Industrial Grade Reliability and Efficiency
- Power failure, port break alarm by relay output
- Redundant dual 12/24/48 VDC power inputs
- IEEE 802.3az energy-efficient Ethernet settings by DIP switch
- Broadcast storm protection and jumbo frame setting by DIP switch
Rugged Design
- Operating temperature range of -10 to 60°C, or extended operating the temperature of -40 to 75°C for “T” models
- IP30, rugged high-strength case
- DIN-rail or panel mounting ability
Panel Layout of EDS-G308/EDS-G308-2SFP
|
---|---
-
Grounding screw
-
Terminal block for power input (PWR1, PWR2) and relay output
-
Power input PWR1 LED
-
Power input PWR2 LED
-
Fault LED
-
TP port’s 10/100 Mbps LED
TP port’s 1000 Mbps LED
SFP port’s 100/1000 Mbps LED
(Amber: 100M; Green: 1000M) -
Port number
-
10/100/1000BaseT(X) Port
-
100/1000Base SFP slot
-
Model Name
-
DIP switches
-
Heat dissipation orifices
-
Screw hole for wall mounting kit
-
DIN-rail Kit
Mounting Dimensions
DIN-Rail Mounting
The aluminum DIN-rail attachment plate should already be fixed to the back panel of the EDS when you take it out of the box. If you need to reattach the DIN-rail attachment plate, make sure the stiff metal spring is situated towards the top, as shown in the figures below.
STEP 1: Insert the top of the DIN rail into the slot just below the stiff metal spring.
STEP 2: The DIN-rail attachment unit will snap into place as shown below.
To remove the DIN-rail from the EDS, simply reverse Steps 1 and 2.
In order to ensure proper installation, please insert the DIN rail below the
metal spring.
Wall Mounting (optional)
For some applications, you will find it convenient to mount the EDS on the
wall, as illustrated below.
STEP 1:
Remove the aluminum DINrail attachment plate from the EDS’s rear panel, and
then attach the wall mount plates, as shown in the figure.
STEP 2:
Mounting the EDS on the wall requires 4 screws. Use the switch, with wall
mount plates attached, as a guide to mark the correct locations of the 4
screws. The heads of the screws should be less than 6.0 mm in diameter, and
the shafts should be less than 3.5 mm in diameter, as shown in the figure at
the right.
NOTE Before tightening screws into the wall, make sure the screw head and shank size are suitable by inserting the screw into one of the keyhole-shaped apertures of the Wall Mounting Plates.
Do not screw the screws in all the way—leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws.
STEP 3:
Once the screws are fixed in the wall, insert the four screw heads through the
large parts of the keyhole-shaped apertures, and then slide the EDS downwards,
as indicated. Tighten the four screws for added stability.
Hazardous Location Information
Logo|
---|---
Model/Rating| | Model Name.| Rated Supply Voltage and Current
---|---
EDS-G308,
EDS-G308-T| 12-48 VDC, Class 2, Maximum 0.8 A
EDS-G308-2SFP,
EDS-G308-2SFP-T| 12-48 VDC, Class 2, Maximum 0.9 A
Relay Output: 24 VDC, 1 A, resistive load.
Serial
Number|
ATEX
information|
DEMKO
10 ATEX 0917324X
Ex nA nC IIC T4 Gc
Ambient Range: -40°C ≤ Tamb ≤ 75°C (With -T)
Ambient Range: -10°C ≤ Tamb ≤ 60°C (Without -T)
WARNING: DO NOT SEPARATE WHEN ENERGIZED
Rated Cable Temp ≥ 90°C
Address of
manufacturer| No. 1111, Heping Rd., Bade Dist., Taoyuan City 334004,
Taiwan
Standards and Certifications|
---|---
Hazardous Location| EN 60079-0:2012+A11:2013
EN 60079-15:2010/
Conditions of safe use
- Transient protection shall be provided to limit the peak-rated voltage to a maximum of 140% of the peak-rated voltage.
- When end users are providing Optical SFP Communications modules, these must be limited to Laser Class 1 only.
- The equipment shall only be used in an area of not more than pollution degree 2, as defined in EN 60664-1.
- The equipment shall be installed in an IP 54 casing in accordance with the EN 60079-15 standard and should only be accessible by the use of a tool.
Wiring Requirements
WARNING
Safety First!
Turn the power off before disconnecting modules or wires. The proper power
supply voltage is listed on the product label. Check the voltage of your power
source to make sure you are using the correct voltage. Do NOT use a voltage
greater than what is specified on the product label. These devices must be
supplied by a SELV source as defined in the Low Voltage Directive 2014/35/EU
and 2014/30/EU.
WARNING
Safety First!
Calculate the maximum possible current in each power wire and common wire.
Observe all electrical codes dictating the maximum current allowable for each
wire size. If the current goes above the maximum ratings, the wiring could
overheat, causing serious damage to your equipment.
You should also pay attention to the following items:
-
Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.
NOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately. -
You can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring with similar electrical characteristics can be bundled together.
-
Keep input wiring and output wiring separated.
-
It is strongly advised that you label wiring for all devices in the system when necessary.
Grounding Moxa EtherDevice Switch
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the ground
screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded mounting surface,
such as a metal panel. We suggest using the cable type AWG min. 18 for
grounding the EDS-G308.
Wiring the Alarm Contact
The Alarm Contact consists of the two middle contacts of the terminal block on
the EDS’s top panel. You may refer to the next section for detailed
instructions on how to connect the wires to the terminal block connector, and
how to attach the terminal block connector to the terminal block receptor.
In this section, we explain the meaning of the two contacts used to connect the Alarm Contact.
FAULT: The two middle contacts of the 6contact terminal block connector are used to detect both power faults and port faults. The two wires attached to the Fault contacts form an open circuit when:
-
EDS has lost power from one of the DC power inputs.
OR -
The PORT ALARM DIP switch for one of the ports is set to ON, but the port is not connected properly.
If neither of these two conditions is satisfied, the Fault circuit will be closed.
Wiring the Redundant Power Inputs
The top two contacts and the bottom two contacts of the 6-contact terminal
block connector on the EDS’s top panel are used for the EDS’s two AC/ DC
inputs. Top and front views of one of the terminal block connectors are shown
here.
STEP 1: Insert the negative/positive DC wires into the V-/V+ terminals.
STEP 2: To keep the DC wires from pulling loose, use a small flat-blade
screwdriver to tighten the wire-clamp screws on the front of the terminal
block connector.
STEP 3: Insert the plastic terminal block connector prongs into the
terminal block receptor, which is located on EDS’s top panel.
ATTENTION
Before connecting the EDS to the DC power inputs, make sure the DC power
source voltage is stable.
We suggest using a copper conductor with the cable type – AWG 18-24 and the
corresponding pin type cable terminals. In addition, the wire must be able to
withstand at least 105°C.
The wire must be able to withstand at least 105°C and the torque value should
be 4.5 lb-in (0.51 N-m). There should only be one individual conductor in a
clamping point.
Communication Connections
EDS-G308 switches have 2 types of communications port:
- 10/100/1000BaseT(X) Ethernet ports
- Combination 10/100/1000T(X) Ethernet or 100/1000BaseSFP fiber ports
10/100/1000BaseT(X) Ethernet Port Connection
The 10/100/1000BaseT(X) ports located on Moxa EtherDevice Switch’s front panel
are used to connect to Ethernet-enabled devices. Most users will choose to
configure these ports for Auto MDI/MDI-X mode, in which case the port’s
pinouts are adjusted automatically depending on the type of Ethernet cable
used (straight-through or cross-over), and the type of device (NIC-type or HUB
/Switch-type) connected to the port.
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X (HUB
/Switch-type) ports. We also give cable wiring diagrams for straight-through
and cross-over Ethernet cables.
10 /100Base T(x) RJ45 Pinouts
MDI Port Pinouts
Pin | Signal |
---|---|
1 | Tx+ |
2 | Tx- |
3 | Rx+ |
6 | Rx- |
MDI-X Port Pinouts
Pin | Signal |
---|---|
1 | Rx+ |
2 | Rx- |
3 | Tx+ |
6 | Tx- |
1000BaseT RJ45 Pinouts
Pin | MDI | MDI-X |
---|---|---|
1 | BI_DA+ | BI_DB+ |
2 | BI_DA- | BI_DB- |
3 | BI_DB+ | BI_DA+ |
4 | BI_DC+ | BI_DD+ |
5 | BI_DC- | BI_DD- |
6 | BI_DB- | BI_DA- |
7 | BI_DD+ | BI_DC+ |
8 | BI_DD- | BI_DC- |
RJ45 (8-pin) to RJ45 (8-pin) Straight-Through Cable Wiring
RJ45 (8-pin) to RJ45 (8-pin) Cross-Over Cable Wiring
100/1000BaseSFP (mini-GBIC) Fiber Port
The Fiber ports on the EDS-G308 series are SFP-type slots, which require 100M
or 1G mini-GBIC fiber transceivers to work properly. Moxa provides complete
transceiver models for various distance requirements.
The concept behind the LC port and cable is quite straightforward. Suppose you
are connecting devices I and II. Unlike electrical signals, optical signals do
not require a circuit in order to transmit data. Consequently, one of the
optical lines is used to transmit data from device I to device II, and the
other optical line is used to transmit data
from device II to device I, for full-duplex transmission.
Remember to connect the Tx (transmit) port of device I to the Rx (receive)
port of device II, and the Rx (receive) port of device I to the Tx (transmit)
port of device II. If you make your own cable, we suggest labeling the two
sides of the same line with the same letter (A-to-A and B-to-B, as shown
below, or A1-to-A2 and B1-to-B2).
ATTENTION
This is a Class 1 Laser/LED product. To avoid causing serious damage to your
eyes, do not stare directly into the Laser Beam.
Redundant Power Inputs
Both power inputs can be connected simultaneously to live DC power sources. If
one power source fails, the other live source acts as a backup and
automatically supplies all of the EDS’s power needs.
Alarm Contact
The Moxa EtherDevice Switch has one Alarm Contact located on the top panel.
For detailed instructions on how to connect the Alarm Contact power wires to
the two middle contacts of the 6-contact terminal block connector, see the
Wiring the Alarm Contact section on page 7. A typical scenario would be to
connect the Fault circuit to a warning light located in the control room. The
light can be set up to switch on when a fault is detected.
The Alarm Contact has two terminals that form a Fault circuit for connecting
to an alarm system. The two wires attached to the Fault contacts form an open
circuit when (1) EDS has lost power from one of the DC power inputs, or (2)
one of the ports, for which the corresponding PORT ALARM DIP switch is set to
ON, is not properly connected.
If neither of these two conditions occurs, the Fault circuit will be closed.
DIP Switch Settings
The default setting for each DIP switch is OFF. The following table explains the effect of setting the DIP switches to the ON positions.
DIP Switch | Setting | Description |
---|---|---|
BSP | ON | Enables broadcast storm protection |
OFF | Disables broadcast storm protection | |
Jumbo Frame | ON | Enables jumbo frame function |
OFF | Disables jumbo frame function | |
802.3az | ON | Enables the energy-efficient Ethernet function |
OFF | Disables the energy-efficient Ethernet function | |
DIP Switch | Setting | Description |
--- | --- | --- |
Port Alarm | ON | Enables the corresponding PORT Alarm. If the port’s link |
fails, the relay will form an open circuit and the fault LED will light up
OFF| Disables the corresponding PORT Alarm. If the port’s link fails, the
relay will form a closed circuit and the fault LED will never light up
ATTENTION
To actively update DIP switch settings, power off and then power on the EDS.
LED Indicators
The front panel of the Moxa EtherDevice Switch contains several LED indicators. The function of each LED is described in the table below.
LED | Color | State | Description |
---|---|---|---|
PWR1 | AMBER | On | Power is being supplied to power input PWR1 |
Off | Power is not being supplied to power input PWR1 | ||
PWR2 | AMBER | On | Power is being supplied to power input PWR2 |
Off | Power is not being supplied to power input PWR2 | ||
FAULT | RED | On | When the corresponding PORT alarm is |
enabled, and the port’s link is inactive.
Off| When the corresponding PORT alarm is enabled and the port’s link is
active, or when the corresponding PORT alarm is disabled.
10/100M (TP port)| AMBER| On| TP port’s 10/100 Mbps link is active.
Blinking| Data is being transmitted at 10/100 Mbps.
Off| TP Port’s 10/100 Mbps link is inactive.
1000M (TP port)| GREEN| On| TP port’s 1000 Mbps link is active.
Blinking| Data is being transmitted at 1000 Mbps.
Off| TP Port’s 1000 Mbps link is inactive.
100/1000M (SFP port)| AMBER| On| SFP port’s 100 Mbps link is active.
Blinking| Data is being transmitted at 100 Mbps.
Off| SFP port 100 Mbps link is inactive.
GREEN| On| SFP port’s 1000 Mbps link is active.
Blinking| Data is being transmitted at 1000 Mbps.
Off| SFP port’s 1000 Mbps link is inactive.
Auto MDI/MDI-X Connection
The Auto MDI/MDI-X function allows users to connect the EDS’s
10/100/1000BaseT(X) ports to any kind of Ethernet device, without paying
attention to the type of Ethernet cable being used for the connection. This
means that you can use either a straight-through cable or a cross-over cable
to connect the EDS to Ethernet devices.
Triple Speed Functionality and Switching
The EDS’s 10/100/1000 Mbps RJ45 switched port auto negotiates with the
connected device for the fastest data transmission rate supported by both
devices. The EDS is a plug-and-play device, so software configuration is not
required at installation or during maintenance. The half/full duplex mode for
the RJ45 switched ports is user-dependent and changes (by auto-negotiation) to
full or half duplex, depending on which transmission speed is supported by the
attached device.
Auto-Negotiation and Speed Sensing
The EDS’s RJ45 Ethernet ports independently support auto-negotiation for
transmission speeds of 10 Mbps, 100 Mbps, and 1000 Mbps, with operation
according to the IEEE802.3 standard. This means that some nodes could be
operating at 10 Mbps, while at the same time, other nodes are operating at 100
Mbps or 1000 Mbps. Auto-negotiation takes place when an RJ45 cable connection
is made, and then each time a LINK is enabled. The EDS advertises its
capability for using 10 Mbps, 100 Mbps, or 1000 Mbps transmission speeds, with
the device at the other end of the cable expected to advertise similarly.
Depending on what type of device is connected, this will result in an
agreement to operate at a speed of 10 Mbps, 100 Mbps, or 1000 Mbps. If an
EDS’s RJ45 Ethernet port is connected to a non-negotiating device, it will
default to 10 Mbps speed and half-duplex mode, as required by the IEEE802.3
standard.
Specifications
Specifications and Pin Assignments
Technology
Standards| IEEE 802.3 for 10BaseT,
IEEE 802.3u for 100BaseT(X) and 100Base FX, IEEE 802.3ab for 1000BaseT,
IEEE 802.3z for 1000BaseX
IEEE 802.3az for Energy-Efficient Ethernet
Flow Control| IEEE 802.3x flow control, back pressure flow control
Interface
RJ45 Ports| 10/100/1000BaseT(X) auto negotiation speed
Fiber Ports| 100Base FX or 1000BaseX SFP slot SFP slot
LED Indicators| PWR1, PWR2, FAULT, 10/100M/1000M
DIP Switch| Port break alarm, broadcast storm protection, jumbo frame, IEEE
802.3az
Alarm Contact| One relay output with current carrying capacity of 1A @ 24 VDC
Power
Input Voltage| 12/24/48 VDC, redundant dual inputs
Input Current| EDS-G308: 0.8 A @ 12-48 VDC
EDS-G308-2SFP: 0.9 A @ 12-48 VDC
Connection| One removable 6-pin terminal block
Overload Current Protection| Present
Reverse Polarity Protection| Present
Mechanical
Casing| IP30 protection, metal case
Dimension (W x H x D)| 52.85 x 135 x 105 mm (2.08 x 5.31 x 4.13 in)
Weight| 880 g (1.94 lb)
Installation| DIN-rail, Wall Mounting (optional kit)
Environmental
Operating Temperature| -10 to 60°C (14 to 140°F) -40 to 75°C (-40 to 167°F)
for -T models
Storage Temperature| -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity| 5 to 95% (non-condensing)
Regulatory Approvals
Safety| UL 508, EN 62368-1
EMI| FCC Part 15, CISPR 32, EN 55032 class A
EMS| EN 61000-4-2 (ESD), Level 3
EN 61000-4-3 (RS), Level 3
EN 61000-4-4 (EFT), Level 3
EN 61000-4-5 (Surge), Level 3
EN 61000-4-6 (CS), Level 3
EN 61000-4-8
EN 61000-4-11
EN 61000-4-12
Shock| IEC 60068-2-27
Free Fall| IEC 60068-2-32
Vibration| IEC 60068-2-6
Note: Please check Moxa’s website for the latest certification status.
MTBF (mean time between failures)
Time| 2,260,195 hours
Standard| Telcordia (Bellcore), GB
Warranty
Warranty Period| 5 years
Details| www.moxa.com/warranty
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>