Little GIANT 6-CBA Sump Pump User Guide

June 15, 2024
Little Giant

Little GIANT 6-CBA Sump Pump

Product Information

Specifications

  • Series: 6 Series
  • HP: 1/3
  • Volts: 115
  • Hz: 50/60

Applications
The Sump Pumps 6 Series – 1/3 HP can be used for the following applications:

  • Basement sumps
  • Dewatering
  • Water transfer

Features

  • Shaded pole motor with thermal overload protection
  • Designed for continuous duty
  • Oil-filled cast iron or cast bronze motor housing for increased corrosion resistance in brackish water
  • PVC riser legs (506162 only)
  • 1-1/2 FNPT discharge
  • 1-1/4 FNPT reducer bushing included with select models
  • 3/4 GHT garden hose adapter included with select models
  • cCSAus listed (115 V models only)

Series Specifications

Model| HP| Volts| Switch Type/Operation| On Level (ft)| Off Level (ft)| Cord (ft)| Weight (lbs)
---|---|---|---|---|---|---|---
506158| 6-CIA| 1/3| 115| Integral Diaphragm| 7 – 10| 1 – 4| 10′| 18 lbs

Performance Data
The performance data of the Sump Pumps 6 Series – 1/3 HP is as follows:

GPM @ Height in Feet 5′ 10′ 15′
Shut-Off (ft) 46 29 12.5
PSI 18 7.8 6

Sump Pump Switch Repair Kit
The Sump Pump Switch Repair Kit includes the following:

  • Pressure switch bracket assembly
  • Screw
  • Diaphragm
  • O-ring

Engineering Data
The engineering data for the Sump Pumps 6 Series – 1/3 HP is as follows:

  • Model 6-CIM-R, 6-CIA-RFS, 6-CIA-RF, 6-CIM, and 6-CBM
  • Model 6-CIA and 6-CBA

Construction

  • Motor Housing: Epoxy-coated cast iron or epoxy-impregnated cast bronze
  • Impeller Material: Nylon
  • Impeller Type: Non-clog
  • Volute: Polypropylene
  • Motor Shaft: CRS
  • Mechanical Shaft Seal: Nitrile with carbon and ceramic faces
  • Fasteners: Stainless steel
  • Bearings: Upper – Sintered iron/copper, flanged sleeve; Lower – Sintered iron/copper, flanged steel
  • Power Cord: 18-3, SJTW

Product Usage Instructions

Installation

  1. Choose a suitable location for the sump pump, preferably in the lowest part of the basement or crawl space.
  2. Ensure that the sump pit is clean and free of debris.
  3. Place the sump pump in the sump pit, making sure it is level and stable.
  4. Connect the discharge pipe to the pump’s 1-1/2 FNPT discharge outlet.
  5. If necessary, use the included reducer bushing to connect a smaller pipe size to the discharge outlet.
  6. If using a garden hose for drainage, attach the included 3/4 GHT garden hose adapter to the pump’s discharge outlet.
  7. Route the discharge pipe or garden hose to a suitable drainage location.
  8. Plug the power cord into a grounded electrical outlet.

Operation

  1. Ensure that the sump pit is continuously monitored for water level.
  2. When the water level reaches the level specified for your model, the sump pump will automatically turn on and start pumping water.
  3. The pump will continue to operate until the water level drops below the off-level specified for your model.
  4. If the sump pump fails to operate or does not turn off, check the power supply and ensure that the float switch is not obstructed.
  5. Regularly inspect and clean the sump pit to prevent debris from interfering with the pump’s operation.

Maintenance
To ensure optimal performance and longevity of your sump pump, follow these maintenance guidelines:

  • Inspect the power cord for any damage and replace it if necessary.
  • Check the float switch for proper operation and adjust if needed.
  • Clean the impeller and volute to remove any debris or buildup that may affect pump performance.
  • Test the pump periodically to ensure it is functioning correctly.
  • Refer to the user manual for any specific maintenance instructions or recommendations.

Troubleshooting
If you experience any issues with your sump pump, refer to the troubleshooting section of the user manual or contact our customer support for assistance.

FAQ

  • Q: Can the sump pump be used for outdoor applications?
    A: The sump pump is designed for indoor use. It is not recommended for outdoor applications.

  • Q: Can I use the sump pump with a larger discharge pipe?
    A: The sump pump is designed to work with a 1-1/2 FNPT discharge outlet. Using a larger discharge pipe may affect the pump’s performance.

  • Q: How often should I clean the sump pit?
    A: It is recommended to inspect and clean the sump pit at least once a year or as needed to prevent debris from interfering with the pump’s operation.

APPLICATIONS

  • Basement sumps, dewatering, water transfer

FEATURES

  • Shaded pole motor with thermal overload protection
  • Designed for continuous duty
  • Oil-filled cast iron or cast bronze motor housing for an increased corrosion resistance option in brackish water
  • PVC riser legs (506162 only)
  • 1-1/2″ FNPT discharge
  • 1-1/4″ FNPT reducer bushing included with select models
  • 3/4″ GHT garden hose adapter included with select models
  • cCSAus listed (115 V models only)

SERIES SPECIFICATIONS

Amps                                    Performance            Shut-Off

Volts           Hz                                        Watts       (GPM @ Height in Feet)         (ft)         PSI

FLA          Start                       5′       10′         15′


115| 50/60| 9.0| 14.3| 720| 46| 29| 12.5| 18| 7.8
Item No.| Model| HP| Volts| Switch Type/ Operation| On Level| Off Level| Cord| Weight
---|---|---|---|---|---|---|---|---
506158| 6-CIA| 1/3| 115| Integral Diaphragm| 7″ – 10″

17.8 cm – 25.4 cm

| 1″ – 4″

2.5 cm – 10.2 cm

| 10′

3 m

| 18 lbs

8.16 Kg

***506160| 6-CIA-ML| 1/3| 115| Integral Diaphragm| 4″-7″

10.2 cm – 17.8 cm

| 1-1/2″ – 3-1/2″

3.8 cm – 8.9 cm

| 10′

3 m

| 18 lbs

8.16 kg

*506162| 6-CIA| 1/3| 115| Integral Diaphragm| 10″ – 13″

25.4 cm – 33.02 cm

| 4″ – 7″

10.2 cm – 17.8 cm

| 10′

3 m

| 18.5 lbs

8.39 Kg

506125| 6-CIA| 1/3| 115| Integral Diaphragm| 7″ – 10″

17.8 cm – 25.4 cm

| 1″ – 4″

2.5 cm – 10.2 cm

| 25′

7.6 m

| 19.5 lbs

8.85 kg

506357| 6-CBA| 1/3| 115| Integral Diaphragm| 7″ – 10″

17.8 cm – 25.4 cm

| 1″ – 4″

2.5 cm – 10.2 cm

| 10′

3 m

| 19.25 lbs

8.73 Kg

*506164| 6-CIA| 1/3| 115| Integral Diaphragm| 10″ – 13″

25.4 cm – 33.02 cm

| 4″ – 7″

10.2 cm – 17.8 cm

| 25′

7.6 m

| 20 lbs

9.07 Kg

506171| 6-CIA-RFS| 1/3| 115| Piggyback Mechanical Float| 9.5″ – 11.5″

24.1 cm – 29.2 cm

| 1″ – 4″

2.5 cm – 10.2 cm

| 10′

3 m

| 17.75 lbs

8.05 Kg

506267| 6-CIA-RS| 1/3| 115| Piggyback Diaphragm| 7″ – 10″

17.8 cm – 25.4 cm

| 3″ – 5″

7.6 cm – 12.7 cm

| 10′

3 m

| 17.5 lbs

7.94 Kg

**506271| 6-CIM-R| 1/3| 115| Manual| –| –| 10′

3 m

| 16.5 lbs

7.48 Kg

**506274| 6-CIM-R| 1/3| 115| Manual| –| –| 25′

7.6 m

| 18 lbs

8.16 Kg

506257| 6-CBM| 1/3| 115| Manual| –| –| 10′

3 m

| 17.75 lbs

8.05 Kg

  • Leg kit included
  • 1-1/4″ FNPT reducer bushing and 3/4″ GHT garden hose adapter included
  • Not recommended for standard sump systems. Intended for use only with the Drainosaur WRSC system or other small sump basins with an operational depth of less than 10 inches.

SUMP PUMP SWITCH REPAIR KIT

APPLICATIONS

  • Switch repair kit

FEATURES

  • Includes pressure switch bracket assembly, screw, diaphragm, and O-ring
Item No. Model Volts Housing
599300 SPRK-1 6-CIA and 6-CBA Ö
599310 SPRK-1-ML 6-CIA-ML (used in WRSC-6) Ö
599320 SPRK-2 6-CIA and 6-CBA
599314 SPRK-2-ML 6-CIA-ML (used in WRSC-6)

ENGINEERING DATA

Model A B C D

6-CIM-R, 6-CIA-RFS,

6-CIA-RF, 6-CIM, and 6-CBM

| 7.25″

18.42 cm

| 9.5″

24.13 cm

| 7.2″

18.29 cm

| –
6-CIA and 6-CBA| 6″

15.24 cm

| 9.5″

24.13 cm

| 8.5″

21.59 cm

| 8.2″

20.83 cm

PERFORMANCE DATA

CONSTRUCTION

Motor Housing| Epoxy-coated cast iron or epoxy-impregnated cast bronze
---|---
Impeller Material| Nylon
Impeller Type| Non-clog
Volute| Polypropylene
Motor Shaft| CRS
Mechanical Shaft Seal| Nitrile with carbon and ceramic faces
Fasteners| Stainless steel

Bearings

|

  • Upper: Sintered iron/copper, flanged sleeve
  • Lower: Sintered iron/copper, flanged steel

Power Cord| 18-3, SJTW

Technical Support: 1.800.701.7894 | www.littlegiant.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>