Little GIANT 6-CBA Sump Pump
Product Information
Specifications
- Series: 6 Series
- HP: 1/3
- Volts: 115
- Hz: 50/60
Applications
The Sump Pumps 6 Series – 1/3 HP can be used for the following applications:
- Basement sumps
- Dewatering
- Water transfer
Features
- Shaded pole motor with thermal overload protection
- Designed for continuous duty
- Oil-filled cast iron or cast bronze motor housing for increased corrosion resistance in brackish water
- PVC riser legs (506162 only)
- 1-1/2 FNPT discharge
- 1-1/4 FNPT reducer bushing included with select models
- 3/4 GHT garden hose adapter included with select models
- cCSAus listed (115 V models only)
Series Specifications
Model| HP| Volts| Switch Type/Operation| On Level (ft)| Off Level (ft)| Cord
(ft)| Weight (lbs)
---|---|---|---|---|---|---|---
506158| 6-CIA| 1/3| 115| Integral Diaphragm| 7 – 10| 1 – 4| 10′| 18 lbs
Performance Data
The performance data of the Sump Pumps 6 Series – 1/3 HP is as follows:
GPM @ Height in Feet | 5′ | 10′ | 15′ |
---|---|---|---|
Shut-Off (ft) | 46 | 29 | 12.5 |
PSI | 18 | 7.8 | 6 |
Sump Pump Switch Repair Kit
The Sump Pump Switch Repair Kit includes the following:
- Pressure switch bracket assembly
- Screw
- Diaphragm
- O-ring
Engineering Data
The engineering data for the Sump Pumps 6 Series – 1/3 HP is as follows:
- Model 6-CIM-R, 6-CIA-RFS, 6-CIA-RF, 6-CIM, and 6-CBM
- Model 6-CIA and 6-CBA
Construction
- Motor Housing: Epoxy-coated cast iron or epoxy-impregnated cast bronze
- Impeller Material: Nylon
- Impeller Type: Non-clog
- Volute: Polypropylene
- Motor Shaft: CRS
- Mechanical Shaft Seal: Nitrile with carbon and ceramic faces
- Fasteners: Stainless steel
- Bearings: Upper – Sintered iron/copper, flanged sleeve; Lower – Sintered iron/copper, flanged steel
- Power Cord: 18-3, SJTW
Product Usage Instructions
Installation
- Choose a suitable location for the sump pump, preferably in the lowest part of the basement or crawl space.
- Ensure that the sump pit is clean and free of debris.
- Place the sump pump in the sump pit, making sure it is level and stable.
- Connect the discharge pipe to the pump’s 1-1/2 FNPT discharge outlet.
- If necessary, use the included reducer bushing to connect a smaller pipe size to the discharge outlet.
- If using a garden hose for drainage, attach the included 3/4 GHT garden hose adapter to the pump’s discharge outlet.
- Route the discharge pipe or garden hose to a suitable drainage location.
- Plug the power cord into a grounded electrical outlet.
Operation
- Ensure that the sump pit is continuously monitored for water level.
- When the water level reaches the level specified for your model, the sump pump will automatically turn on and start pumping water.
- The pump will continue to operate until the water level drops below the off-level specified for your model.
- If the sump pump fails to operate or does not turn off, check the power supply and ensure that the float switch is not obstructed.
- Regularly inspect and clean the sump pit to prevent debris from interfering with the pump’s operation.
Maintenance
To ensure optimal performance and longevity of your sump pump, follow these
maintenance guidelines:
- Inspect the power cord for any damage and replace it if necessary.
- Check the float switch for proper operation and adjust if needed.
- Clean the impeller and volute to remove any debris or buildup that may affect pump performance.
- Test the pump periodically to ensure it is functioning correctly.
- Refer to the user manual for any specific maintenance instructions or recommendations.
Troubleshooting
If you experience any issues with your sump pump, refer to the troubleshooting
section of the user manual or contact our customer support for assistance.
FAQ
-
Q: Can the sump pump be used for outdoor applications?
A: The sump pump is designed for indoor use. It is not recommended for outdoor applications. -
Q: Can I use the sump pump with a larger discharge pipe?
A: The sump pump is designed to work with a 1-1/2 FNPT discharge outlet. Using a larger discharge pipe may affect the pump’s performance. -
Q: How often should I clean the sump pit?
A: It is recommended to inspect and clean the sump pit at least once a year or as needed to prevent debris from interfering with the pump’s operation.
APPLICATIONS
- Basement sumps, dewatering, water transfer
FEATURES
- Shaded pole motor with thermal overload protection
- Designed for continuous duty
- Oil-filled cast iron or cast bronze motor housing for an increased corrosion resistance option in brackish water
- PVC riser legs (506162 only)
- 1-1/2″ FNPT discharge
- 1-1/4″ FNPT reducer bushing included with select models
- 3/4″ GHT garden hose adapter included with select models
- cCSAus listed (115 V models only)
SERIES SPECIFICATIONS
Amps Performance Shut-Off
Volts Hz Watts (GPM @ Height in Feet) (ft) PSI
FLA Start 5′ 10′ 15′
115| 50/60| 9.0| 14.3| 720| 46| 29| 12.5| 18| 7.8
Item No.| Model| HP| Volts| Switch Type/ Operation| On Level| Off Level| Cord|
Weight
---|---|---|---|---|---|---|---|---
506158| 6-CIA| 1/3| 115| Integral Diaphragm| 7″ – 10″
17.8 cm – 25.4 cm
| 1″ – 4″
2.5 cm – 10.2 cm
| 10′
3 m
| 18 lbs
8.16 Kg
***506160| 6-CIA-ML| 1/3| 115| Integral Diaphragm| 4″-7″
10.2 cm – 17.8 cm
| 1-1/2″ – 3-1/2″
3.8 cm – 8.9 cm
| 10′
3 m
| 18 lbs
8.16 kg
*506162| 6-CIA| 1/3| 115| Integral Diaphragm| 10″ – 13″
25.4 cm – 33.02 cm
| 4″ – 7″
10.2 cm – 17.8 cm
| 10′
3 m
| 18.5 lbs
8.39 Kg
506125| 6-CIA| 1/3| 115| Integral Diaphragm| 7″ – 10″
17.8 cm – 25.4 cm
| 1″ – 4″
2.5 cm – 10.2 cm
| 25′
7.6 m
| 19.5 lbs
8.85 kg
506357| 6-CBA| 1/3| 115| Integral Diaphragm| 7″ – 10″
17.8 cm – 25.4 cm
| 1″ – 4″
2.5 cm – 10.2 cm
| 10′
3 m
| 19.25 lbs
8.73 Kg
*506164| 6-CIA| 1/3| 115| Integral Diaphragm| 10″ – 13″
25.4 cm – 33.02 cm
| 4″ – 7″
10.2 cm – 17.8 cm
| 25′
7.6 m
| 20 lbs
9.07 Kg
506171| 6-CIA-RFS| 1/3| 115| Piggyback Mechanical Float| 9.5″ – 11.5″
24.1 cm – 29.2 cm
| 1″ – 4″
2.5 cm – 10.2 cm
| 10′
3 m
| 17.75 lbs
8.05 Kg
506267| 6-CIA-RS| 1/3| 115| Piggyback Diaphragm| 7″ – 10″
17.8 cm – 25.4 cm
| 3″ – 5″
7.6 cm – 12.7 cm
| 10′
3 m
| 17.5 lbs
7.94 Kg
**506271| 6-CIM-R| 1/3| 115| Manual| –| –| 10′
3 m
| 16.5 lbs
7.48 Kg
**506274| 6-CIM-R| 1/3| 115| Manual| –| –| 25′
7.6 m
| 18 lbs
8.16 Kg
506257| 6-CBM| 1/3| 115| Manual| –| –| 10′
3 m
| 17.75 lbs
8.05 Kg
- Leg kit included
- 1-1/4″ FNPT reducer bushing and 3/4″ GHT garden hose adapter included
- Not recommended for standard sump systems. Intended for use only with the Drainosaur WRSC system or other small sump basins with an operational depth of less than 10 inches.
SUMP PUMP SWITCH REPAIR KIT
APPLICATIONS
- Switch repair kit
FEATURES
- Includes pressure switch bracket assembly, screw, diaphragm, and O-ring
Item No. | Model | Volts | Housing |
---|---|---|---|
599300 | SPRK-1 | 6-CIA and 6-CBA | Ö |
599310 | SPRK-1-ML | 6-CIA-ML (used in WRSC-6) | Ö |
599320 | SPRK-2 | 6-CIA and 6-CBA | – |
599314 | SPRK-2-ML | 6-CIA-ML (used in WRSC-6) | – |
ENGINEERING DATA
Model | A | B | C | D |
---|
6-CIM-R, 6-CIA-RFS,
6-CIA-RF, 6-CIM, and 6-CBM
| 7.25″
18.42 cm
| 9.5″
24.13 cm
| 7.2″
18.29 cm
| –
6-CIA and 6-CBA| 6″
15.24 cm
| 9.5″
24.13 cm
| 8.5″
21.59 cm
| 8.2″
20.83 cm
PERFORMANCE DATA
CONSTRUCTION
Motor Housing| Epoxy-coated cast iron or epoxy-impregnated cast
bronze
---|---
Impeller Material| Nylon
Impeller Type| Non-clog
Volute| Polypropylene
Motor Shaft| CRS
Mechanical Shaft Seal| Nitrile with carbon and ceramic faces
Fasteners| Stainless steel
Bearings
|
- Upper: Sintered iron/copper, flanged sleeve
- Lower: Sintered iron/copper, flanged steel
Power Cord| 18-3, SJTW