SOMMER ASB Stahl Parking Barrier Instruction Manual

June 15, 2024
SOMMER

ASB Stahl Parking Barrier

SOMMER ASB Stahl Parking Barrier - Barrier
ASB Alu
ASB Stahl ASB-S13141-00001_062022_0-DRE_Rev-C_EN

Information on the product

Serial No.:
See the title page of the installation and operating manual (if applicable warranty label).
Year of manufacture: from 5.2020
Information on the Installation and Operating Manual
Warranty
The warranty complies with statutory requirements. The contact person for warranties is the specialist retailer.
The warranty is only valid in the country in which the operator was purchased.
Batteries, fuses and light bulbs are excluded from the warranty.
Contact data
To ensure quick and efficient processing of your inquiry, please make a note of the serial number and the type code given on the type plate before phoning.
If you require after-sales service, spare parts or accessories, please contact your specialist retailer/installer.
SOMMER Antriebs- und Funktechnik GmbH
Hans-Böckler-Str. 21-27
D-73230 Kirchheim/Teck
www.sommer.eu
info@sommer.eu
Feedback on this Installation and Operating Manual
We have tried to make the Installation and Operating Manual as easy as possible to follow. If you have any suggestions as to how we could improve it or if you think more information is needed, please send your suggestions to us:
doku@sommer.eu

Service
If you require service, please contact us on our service hotline (fee required) or see our web site:
+49 (0)900-1800150
(0.14 euros/minute from a German landline, mobile prices may vary)
https://www.sommer.eu/de/servicepartner.html

Copyright and proprietary rights
The manufacturer retains the copyright for this Installation and Operating manual. No part of this Installation and Operating Manual may be reproduced in any form or processed, copied, or distributed using electronic systems without the written permission of SOMMER Antriebs- und Funktechnik GmbH.
Violations of the above stipulations will lead to damage claims.
All brands mentioned in this manual are the property of their respective manufacturer and hereby recognised as such.

User information

User information Storage and circulation of the manual
This manual must always be available at the site of installation and use of the barrier.
The operator must inform the personnel about the storage location of this manual and its supplementary manuals.
If the manual has become unreadable due to constant use, the operator must obtain a replacement from the manufacturer. To reorder the manual, contact the Customer Service department.
During the transfer or resale of the barrier to third parties, the following documents must be passed on to the new owner:

  • this manual,
  • documentation of retrofitting and repair work,
  • proof of regular testing,
  • other applicable documents; see “Other applicable documents” on page 4

Description of the product type
The ASB Alu and ASB Stahl barriers have been constructed to the technical state-of-the-art and in accordance with recognised technical regulations and are subject to the EC Machinery Directive (2006/42/EC).
This manual describes an industrially, commercially, and privately usable, power-activated barrier for vehicle traffic. The barrier is used to block and open entrances and exits of car parks and other driveways.
The ASB Alu and ASB Stahl barriers are available in both right-closing and left-closing designs. A conversion is not possible.
Optionally available accessories are also described. The actual scope of delivery may deviate from that described here.

Target group of the manual
This manual must be read and observed by all persons assigned with one of the following tasks:

  • in-house transport
  • unpacking and installation
  • initial operation
  • setting
  •  troubleshooting
  • testing
  • taking out of operation
  • disassembly
  • storage
  • disposal

Other applicable documents
In addition to this manual, observe the following (technical) documents/ regulations:

  • national regulations regarding accident prevention
  • national regulations regarding environmental protection
  • information regarding supervisory and reporting responsibilities, as well as company organisation
  •  recognised technical regulations for safe working

Explanation of symbols
The following symbols and signal words are used in this manual:

DANGER
Designates an immediate danger that may lead to death or extremely severe injuries.
WARNING
Designates a possible danger that may lead to death or extremely severe injuries.
NOTE
Designates a possible danger that may lead to damage to the system or the environment.
INFORMATION:
Designates additional information and useful tips.

1 1 Refers to a part or machine component in a picture.
Warning symbols
If the source of danger can be specified more precisely, the following symbols are used together with the signal words listed above:
DANGER DUE TO ELECTRIC CURRENT!
If live parts are touched, current can flow through the body, possibly leading to electric shock, burns, or death.
DANGER OF TIPPING!
This symbol is used to indicate a danger of tipping during the transport and installation of the barrier.
DANGER DUE TO CLOSING BARRIER!
Failure to observe these instructions can lead to dangerous situations resulting in serious injuries.
RISK OF BURNS!
Failure to observe these instructions can lead to dangerous situations resulting in serious burns.
RISK OF CRUSH INJURIES TO HANDS!
Failure to observe these instructions can lead to dangerous situations resulting in serious crush injuries to the hands.
RISK OF CRUSH INJURIES TO THE BODY!
Failure to observe these instructions can lead to dangerous situations resulting in serious crush injuries to the body.

Information regarding the depiction of text

  • Stands for general safety instructions which must be observed!
    „ Stands for directions for an action with one or two instructions.
    1. Stands for directions for an action with three or more instructions.
    • Stands for lists within the action.
    ⇒ Stands for the results of the action.
    Lists without a mandatory order are shown as a list with bullet points (Level
  1. and en-dashes (Level 2):
    • List 1,
    – point A,
    – point B.
    • List 2.

Information regarding illustrations
The graphics provided in this Installation and Operating Manual are intended to serve as examples. Depending on the specific model, details in the graphics may differ from those of your product.

Intended use
Operate the barrier only if it is in perfect, traffic-safe condition and in a safety- and risk-conscious manner.
The ASB Stahl and ASB Alu barriers are suited for industrial, commercial and private use in the following applications:

  •  to block and open the entrances and exits of car parks and other driveways to which vehicles of all types have access,
  •  for use with a boom length from 2.5 metres to 6 metres
  • maximum of 350 operating cycles per day,
  • use with the required safety clearances to the surroundings,
  • use with appropriate safety devices and command devices oriented to the expected vehicle traffic,
  •  use in wind:

boom 400, 580, 500 LED 2.5 m – 3 m for max. wind strength 9 Bft
boom 400, 580, 500 LED >3 m – 6 m for max. wind strength 5 Bft

Improper use
WARNING
Danger caused by improper use! 

  •  Use the barrier only as intended and follow all warnings and safety instructions in the manual to the letter!

Any use not listed in the chapter “Intended Use” is deemed to be improper.
The operator of the barrier bears sole liability for any damage resulting from improper use. This also applies to unauthorised changes, modifications, and programming of the barrier and its parts.
In particular, the following are not permitted:

  • use by pedestrians and cyclists,
  •  use at toll booths,
  •  use in parking garages,
  • use with defective parts,
  • use in enclosed spaces,
  • use in explosive atmospheres or in environments with hazardous, flammable gases,
  •  installation of the barrier without a foundation or with a foundation that does not meet the requirements listed in the chapter “Creating the barrier foundation with supply connections” on page 14,
  • use on foundations with an upward or downward slope,
  • use of spare parts and accessories that have not been tested and approved by SOMMER Antriebs- und Funktechnik GmbH,
  • modification of the barrier or individual parts without the permission of SOMMER Antriebs- und Funktechnik GmbH,
  • misuse of the barrier or individual parts of the barrier for a similar area of application.

Qualifications of personnel
Persons under the influence of drugs, alcohol, or medications that can influence their ability to react may not work on the barrier.

WARNING
Risk of injury due to insufficiently qualified personnel!

  • Incorrect handling of the barrier can cause significant injury and damage to property.
  • All work on the barrier must be carried out by suitably qualified personnel.

Operator
The operator owns the barrier or has rented it.
In addition to the contractually regulated transfer of responsibilities to the operator, the operator is also responsible for ensuring use of the barrier as intended.
The operator is responsible for making sure that all personnel meet all necessary physical and mental requirements for the tasks assigned to them.

Qualified transport personnel
The barrier is transported to the operator’s premises by a specialist dealer or by a haulage company commissioned by the specialist dealer.
Transport may not be performed by the operating personnel or by the operator. This does not apply to in-house transport.
Qualified personnel for the foundation
The foundation of the barrier must be laid by a trained expert. This trained expert must provide the required proof of static stability in accordance with the local building regulations.
If necessary, consult a structural engineer.
Qualified personnel for installation, initial operation and disassembly
The installation, initial operation and disassembly of the barrier must be performed by a trained expert.
Personnel must be familiar with the local accident prevention regulations.
Minors or trainees may only perform this work under the supervision of an experienced specialist and with the express permission of the operator.
Electricians
All work on the electrical system and live parts must be performed by a trained electrician.
Work on the electrical system or live parts must not be performed by the qualified personnel for installation, initial operation and disassembly or by the operator.
Qualified operating personnel
The qualified operating personnel are assigned the following responsibilities and tasks:

  •  setting the operating mode,
  • emergency release of the barrier,
  • eliminating malfunctions or initiating measures to eliminate malfunctions,
  • testing the barrier at the intervals specified in the testing schedule.

These persons must be named by the operator and have taken part in training on the operation of the barrier provided by the operator.
Minors or trainees may only perform this work under the supervision of an experienced specialist and with the express permission of the operator.

Users
The barrier may be used by all persons who have reached the age of 18.
Minors may only use the barrier when accompanied by an adult.
Users are assigned the following responsibilities and tasks:

  • opening and closing the barrier using the command devices,
  • use of the barrier by vehicles guided (control) by the users.

Responsibilities of the operator
The operator of the barrier remains responsible for its use at all times unless otherwise agreed. This also applies when the barrier is used by third parties. We would like to point out expressly that the ASB Stahl and ASB Alu barriers may only be used for vehicle traffic. Persons must not use the barrier. The operator must use suitable measures to guarantee a strict separation of vehicle and pedestrian traffic. Structural separations such as pedestrian paths next to the traffic lane must be supplemented with warnings and corresponding signs. The opening and closing movements must be observed and monitored using suitable measures. Operation of the barrier system without safety devices, visual supervision or monitoring is not permitted. In addition, the operator of the barrier must:

  • assign the various tasks at the barrier to qualified, suitable, authorised personnel,
  •  train the operating personnel in the proper operation of the barrier and the effect of all safety devices and document the training. The training or instruction of the personnel must be confirmed in writing!
  • have damage repaired and faulty parts replaced immediately by suitable qualified personnel,
  •  commission experts to test the barrier system at regular intervals and keep a record of these tests,
  • document retrofitting work,
  • ensure that the barrier is operated only in technically perfect condition,
  • equip personnel with suitable protective work clothing,
  • installation signal boards notices, or structures (railings) so that pedestrians are sufficiently warned and do not walk through the barrier system,
  • design the entrance widths for vehicles in such a way that wider, longer, and high vehicles can enter comfortably without damaging the installation.

INFORMATION:
See also Chapter “Installation preparations” on page 14.
The necessary preparations and responsibilities are listed there.

Safety labelling on the barrier
The danger zone of the barrier is labelled with a warning sign. In addition, reflectors can be attached to the boom.
Before the operation of the barrier, the operator and personnel must be familiarised with the position and meaning of the warning sign on the barrier.
All warning signs and reflectors attached in and to the barrier must always be easily visible and undamaged.
Damaged or missing warning signs and reflectors must be replaced by the operator immediately.
Warning signs on the barrier
The following warning sign is attached to the barrier:

SOMMER ASB Stahl Parking Barrier - barrier

The following warning signs must be attached by the installer/operator:

SOMMER ASB Stahl Parking Barrier - operator

Personal protective equipment
The table below shows which protective equipment must be worn for the special work requirements and which safety measures must be taken.

| | | | |
---|---|---|---|---|---
Transport| X| X| X| | X
Installation| | X| X| X| X
Initial operation| | | | | X
troubleshooting| | | X| | X
Disassembly| | X| X| X| X
Disposal| X| X| X| | X

Spare parts and accessories

WARNING
Risk of injury caused by use of incorrect spare parts!
The use of incorrect or faulty spare parts can lead to damage, malfunctions or failure of the system and may impair safety.

  •  Only use original spare parts!

If safety-relevant parts are replaced, their function must be checked afterwards.
Use only accessories approved by SOMMER Antriebs- und Funktechnik GmbH. The use of accessories can change the way the barrier works. In addition, observe the instructions for work and safety when using accessories.

Product description

Scope of delivery
INFORMATION:
Mounting material such as heavy-duty anchors is not included. The installer must select mounting material suitable for the respective subsurface.
p. “Creating the barrier foundation with supply connections” on page 14
Optionally available: Oval boom in various models, see “Boom” on page 10

ASB Alu
The actual scope of delivery may vary depending on the design of the barrier. The standard scope of delivery contains the following items:

SOMMER ASB Stahl Parking Barrier - ASB Alu

Item Quantity Designation
1 1 Barrier housing – left-closing or right-closing design
2 2 U-profiles
3 2 Springs factory-installed
4 1 Shim plate
5 1 Screw set
6 2 Keys for the barrier housing
7 1 Installation and Operating Manual
8 2 Warning signs
9 1 Pearl Vibe handheld transmitter

ASB Stahl
The actual scope of delivery may vary depending on the design of the barrier. The standard scope of delivery contains the following items:

SOMMER ASB Stahl Parking Barrier - ASB Stahl

Item Quantity Designation
1 1 Barrier housing – left-closing or right-closing design
2 2 U-profiles
3 2 Springs factory-installed
4 1 Shim plate
5 1 Screw set
6 2 Keys for the barrier housing
7 1 Installation and Operating Manual
8 2 Warning signs
9 1 Pearl Vibe handheld transmitter

INFORMATION :
The detailed list of the scope of delivery can be found on the order form.

Boom
INFORMATION:
A boom is not included in the scope of delivery, but can be ordered separately. The following models are available:

| Length| Profile| ASB Alu| ASB Stahl
---|---|---|---|---
400| 4 m| | ✔| ✔
580| 5.8 m| ✔| ✔
LED 500| 5 m| | ✔|

Dimensions
All dimensions in mm
ASB Alu

SOMMER ASB Stahl Parking Barrier - ASB Stahl1

ASB Stahl

SOMMER ASB Stahl Parking Barrier - ASB Stahl2

Technical data

| ASB Alu| | ASB Stahl
---|---|---|---
Weight without boom| 50 kg| | 60 kg
Weight of boom| 5.5 kg| | 5.5 kg
Maximum opening width| 400=3,7m 580=5,5m LED500=4,7 m| 400=3,7m 580=5,5m
Opening time| 7 sec?| | 7 sec?
Closing time| 7 sec?| | 7 sec.•
Voltage supply| 220 – 240 V; 50 – 60 Hz| | 220 – 240 V; 50 – 60 Hz
Motor| 24 V, DC| | 24 V, DC
Power consumption in normal operation| 60 W| | 60 W
Power consumption (power-saving mode)| max. 1.3 W| | max. 1.3 W
Dimensions without boom| H 1080 mm x W 350 mm xD 250 mm| | H 1080 mm x W 350 mm xD 250 mm
IP code| IP44| | IP44
Workplace-based emission value| < 75 dBA| | < 75 dBA
Temperature range| -25 °C to + 65 °C| | -25 °C to + 65 °C
Maximum wind strength according to Beaufort scale| | Boom 2.5 – 3 m: max wind strength 9
| Boom 3 – 6m: max. wind strength 5
Permitted cycles| Max. 350 cycles/day| | 1 Max. 350 cycles/day

  • Opening and closing times may vary depending on the boom design and length of the boom

Type plate
The type plate is attached to the inside of the housing.
The type plate bears the following data:

  •  company name and full address of the manufacturer,
  • designation of the machine,
  • CE mark,
  • type designation and serial number,
  • date of manufacture (week number/year) of the barrier.
  • Information on correct disposal:

Transport / Unloading / Storage

Transport
The barrier is transported to the operator’s premises by a specialist dealer or by a haulage company commissioned by the specialist dealer.
After the contractually regulated handover of all responsibility to the operator, the operator must make sure that the barrier is safely and properly transported.
It is compulsory to observe the following information regarding transport:

  •  Do not stack the packaging units on top of each other.
  • Transport the packaging units in the position specified on the packaging.
  • Even during transport, observe the ambient conditions (temperature, humidity, etc.) specified by the manufacturer.
  •  Always make sure that the barrier is transported without impact and jolts.
  • Always secure the loads to be transported against falling, tipping over, and damage.

unloading and in-house transport
WARNING
During this work, dangers may arise, for example, due to uneven surfaces, sharp edges or the use of operating and auxiliary materials.
Body parts may be injured.

  •  Wear suitable, close-fitting protective work clothing  as a minimum, safety helmet, safety shoes, and safety gloves). Do not wear long hair loose.

DANGER
Falling load!
During unloading, the load may fall and cause severe or fatal injuries.

  •  Use lifting equipment designed for the weight of the load.
  •  Never step under suspended loads.

Check packaging units for externally visible transport damage or other damage. If damage is found, have it confirmed by the haulage company and inform SOMMER Antriebs- und Funktechnik GmbH in writing immediately after delivery.
After unloading, store the barrier until setup. For this purpose, the operator of the barrier may have to transport the barrier from the place of unloading to the storage location.
If this is the case, observe the following information regarding unloading and intermediate transport:

  •  For unloading and in-house transport, at least two persons are required.
  • Use only suitable, tested, and standardised lifting equipment (fork lift truck, mobile crane, overhead crane) and attachments (slings, lifting belts, sling ropes, chains).
  • When selecting the lifting equipment and attachments, always take the maximum load-bearing capacities into consideration.
  • Always make sure that the barrier is unloaded and transported without impact and jolts.
  •  Do not stack the packaging units on top of each other.
  • After unloading, do not remove the packaging materials or transport locks.

Storage
NOTE!
The operator and other assemblies of the barrier may be damaged by incorrect storage.
Irreparable damage to the barrier may be the result.

  • Observe the following storage conditions on first delivery and during intermediate storage!

For transport, the packaging units are packed in a plastic film which protects them against environmental influences.

  •  Do not remove or damage this plastic film. If necessary, additionally cover the assemblies.
  •  Store the packaging units in enclosed, dry rooms in which they are protected against moisture and UV radiation.
  •  Store the packaging units at a storage temperature from –20°C to +60°C.
  •  Store the packaging units in the position specified on the packaging.
  •  Do not stack the packaging units on top of each other.
  •  leave room for unhindered passage

Installation preparations

SOMMER ASB Stahl Parking Barrier - ASB Stahl3

A possible installation scenario is shown here as an example.
Work with the user to decide on the position of the accessories before installation.
INFORMATION!
Further possible command devices are Telecody and interior radio push-buttons. In the case of Telecody or interior radio push-buttons, there is no need to install a connecting line to the operator. Ask your specialist dealer.

1 Warning light DC 24 V
2 Key switch
3 Photocell
4 Left-closing barrier
5 Right-closing barrier
6 Main switch (lockable)
7 Induction loop
8 Handheld transmitter with car/wall holder

Before the installation of the barrier, organisational and on-site preparations must be made.
Information on preparing for installation

RISK OF CRUSH INJURIES TO HANDS!
Risk of crushing at the lever system of the barrier when the hood is open.

  • All work on the barrier must be carried out by qualified personnel!
  • Before working on the barrier, always disconnect the system and secure it to prevent reactivation!
  • Install the barrier housing without the boom!
  •  Follow the instructions on personal protective equipment!
  •  The total length of the boom is not equal to the effective opening width.
  •  For a boom length of more than 4 metres, a floating support or support post is required. There must be a safety distance of at least 500 mm (A) in each case between the barrier housing/the tip of the boom and the next stationary obstacle (building, wall, fence, etc.).
  • The mains connection must be in accordance with EN 12453 (omnipolar mains circuit breaker). For this purpose, install a lockable main switch (all-pole deactivation).
  •  Operate barriers only with a permanently laid line protected by a fuse (16A, slow-acting). The power cord connected in the as-delivered state is not approved for constant or outdoor operation.
  •  A minimum distance of 5 metres must be observed between the range of movement of the barrier and overhead power lines/trees.
  • Provide empty ducts in the foundation of the barrier and throughout the installation site for the cables of the mains supply line and the accessories (photocell, warning light, key switch, etc.).

Installation drawing
The position of the foundation, the length of the boom, and, where applicable, the position of the support post can be calculated using the overview illustration.

SOMMER ASB Stahl Parking Barrier - drawing

X = Boom length (1500 mm to 6000 mm)
Y = Distance from the tip of the boom to the centre of the support post or floating support. Minimum 150 mm, maximum 300 mm
Z = Opening width of the barrier – drive-through width
Example calculation:
Calculation of the boom length (X) with:
Opening width of the barrier (Z) = 3500 mm
Distance between the tip of the boom and the centre of the support post (Y) = 200 mm
X = Z + Y + 280 mm
X = 3500 mm + 200 mm + 280 mm
X = 3980 mm
Creating the barrier foundation with supply connections

For the proper operation of the barrier, the barrier housing must stand securely.
The following table shows the foundation size recommended by SOMMER Antriebs- und Funktechnik GmbH. Depending on the danger of frost, the depth of the foundation (D) must be adapted in a frost-proof manner so that the ground cannot lift.

| D| B| L
---|---|---|---
Recommended| Frost-proof! 800 mm in Germany| 300 mm| 400 mm

When selecting the empty ducts, take all the lines to be laid into consideration. These may be:

  •  power supply line,
  • connecting line for photocell/induction loop,
  •  connecting line for the stationary command devices,
  • connecting line for accessories such as warning light, external antenna, etc.

WARNING
Never lay the power supply line in the same duct as the connecting lines.
Interference in the control unit may result.

  •  Use different empty ducts for the power supply line and the connecting lines.

Use only lines/cables suitable for outdoor use (resistance to cold, UV- resistance).
The surface of the foundation must be even and absolutely horizontal to the traffic lane (smoothed) so that the barrier housing can be set up evenly. Use concrete with the following strength class:
– EN 206 C25/30 XC4, XF1, XA1 (25-30 N/mm²)
The foundation must be massive and steel-reinforced.
The barrier housing is attached using heavy-duty anchors (not included in the scope of delivery).
Minimum size of the heavy-duty anchor M10x120 or M12x125.

INFORMATION:
For further information on heavy-duty anchors, contact your specialist dealer.
Creating the foundation for the support post
A stable foundation is required for the installation of the support post.
The minimum size for the foundation is specified in the following table.
Depending on the danger of frost, the depth of the foundation (D) must be adapted in a frost-proof manner so that the ground cannot lift.

SOMMER ASB Stahl Parking Barrier - drawing1

D B L
Frost-proof! 800 mm in Germany 200 mm 200 mm

The surface of the foundation must be even and absolutely horizontal to the traffic lane (smoothed) so that the support post can be set up straight.
Use concrete with the following strength class:
– EN 206 C25/30 XC4, XF1, XA1 (25-30 N/mm²)
The barrier housing is attached using heavy-duty anchors (not included in the scope of delivery).
Minimum size of the heavy-duty anchor M8x75 or M10x85.
INFORMATION:
For further information on heavy-duty anchors, contact your specialist dealer.

Stationary command devices
Stationary command devices (key switch, pushbutton, etc.) must be positioned in such a way that

  • they can be reached easily from any vehicle,
  • the user is not in the range of movement of the barrier,
  • the user has a direct view of the barrier during actuation.

Safety measures
For the safe operation of the barrier, the operator must install the necessary safety devices. The opening and closing movements must be monitored using suitable measures.
Examples of such measures are:

  • photocells,
  •  induction loops.

INFORMATION:
Up to two safety devices can be connected to the control unit! A safety device must always be connected as a normally closed contact so that safety is always guaranteed in the event of a defect.
Pedestrian traffic
The ASB Alu and ASB Stahl barriers may only be used for vehicle traffic.
Persons must not use the barrier.
The operator must use suitable measures to guarantee a strict separation of vehicle and pedestrian traffic. Structural separations such as pedestrian paths next to the traffic lane must be supplemented with warnings and corresponding signs.
Tools required
The following tools must be available in order to perform proper installation:

SOMMER ASB Stahl Parking Barrier - Tools required

Installation

Safety information for installation

WARNING
Risk of injury caused by the closing boom!

  • Keep out of the range of movement of the boom!

WARNING
Risk of injury through incorrect attachment of parts!

  • Before initial operation, check that the heavy-duty anchors and all screws are tightly and securely seated!

RISK OF CRUSH INJURIES TO THE BODY!
Danger of crush injuries
Observe a minimum distance of 0.5 m between the boom and surrounding objects!
RISK OF CRUSH INJURIES TO HANDS!
Danger of crush injuries at the lever system

  •  Install the barrier housing without the boom!
  •  Follow the instructions on personal protective equipment!

DANGER OF TIPPING!
The barrier may tip during installation and in-house transport.
This can cause injuries and damage to the barrier.

  • Transport and installation must be performed by two persons and using suitable transport equipment.
  •  All work on the barrier must be carried out by qualified personnel!
  •  Before working on the barrier, always disconnect the system and secure it to prevent reactivation!
  •  Perform installation only up to a maximum wind strength of 3 on the Beaufort scale (light wind).
  •  At least two persons are required for the entire installation.
  •  For installation work performed above body height, use suitable, tested, and stable climbing aids. Never use the barrier or parts of the barrier as climbing aids.

Checking the scope of delivery
Remove the barrier and all accessories from the packaging at the installation site. No sharp objects may be used to open the packaging since otherwise, parts could be damaged.
Check the delivery for completeness (see “Scope of delivery” on page 9 and order form).
In the case of an incomplete delivery, contact your specialist dealer or SOMMER Antriebs- und Funktechnik GmbH.
Dispose of the packaging in accordance with national regulations.

Installing the barrier housing

  1. Pull the cables into the empty ducts and label them for later use.
    SOMMER ASB Stahl Parking Barrier - Tools required1
    1. Measure and mark the drill holes for the foundation.
    SOMMER ASB Stahl Parking Barrier - Tools required2

  2. Drill four holes Ø 10 or Ø 12 mm and at least 65 mm deep.
    SOMMER ASB Stahl Parking Barrier - Tools required3

  3. Blow out holes with compressed air.
    NOTE:
    Only use permissible fastening materials. For recommended heavy-duty anchors, see “Creating the barrier foundation with supply connections” on page 14

  4. Insert 4 heavy-duty anchors into the holes.

  5.  Put the barrier housing in place and open the door.
    INFORMATION:
    Remove the control unit and place it to one side. Do not reinstall the control unit until after connection to the mains power.

  6.  Insert both U-profiles.

  7. Align the barrier housing or U-profiles. Put 4 washers in place and tighten 4 nuts. With the spirit level, check the horizontal alignment of the barrier and correct it if necessary.

  8. Close the barrier housing.

Adapting the length of the boom
Booms 400 and 580

INFORMATION:
The total length of the boom is not equal to the effective opening width!
To calculate the required length of the boom, see “Installation drawing” on page 14.

SOMMER ASB Stahl Parking Barrier - Booms

  1. Remove the cover from the tip of the boom.
  2.  Cut the boom to the desired length and deburr it if necessary.
  3. Place the cover onto the tip of the boom.

Boom LED 500
WARNING
Risk of electric shock!
The LED boom must be de-energised before shortening it!
INFORMATION:
The total length of the boom is not equal to the effective opening width!
INFORMATION:
When using an LED boom, be careful not to damage cables and LED bars when sawing.
To calculate the required length of the boom, see “Installation drawing” on page 14.

SOMMER ASB Stahl Parking Barrier - Booms1

  1. Remove the cover from the tip of the boom.
  2. Mark the desired length.
  3. Pull out the cover of the LED bar.
  4. Cut the LED bar to the required length.
  5. Saw the boom and the cover of the LED bar to the desired length and deburr if necessary.
  6. Reassemble in reverse order.

Installation of the boom
Oval boom 400 / 580
INFORMATION:
When using a floating support, install it before installing the boom; see “Installing the floating support” on page 20

  1. The boom is attached in the vertical opening position.
  2. Place boom on the adapter plate and fasten it in position using the support plate and the mounting material provided.

Oval boom 500 LED
INFORMATION:

  • A relay (Relay) which is available separately is required for the traffic-light function with the boom lighting.
  • The boom lighting is switched off when the barrier switches to power-saving mode. Power-saving mode must be deactivated if this is not required; see Page 28.

SOMMER ASB Stahl Parking Barrier - LED

  1. The boom is attached in the vertical opening position.

  2.  Connect the two plug ends

  3.  Install the boom.
    ⇒ One person positions the boom and holds it in place.
    ⇒ The second person runs the cable through the opening and screws on the boom and the shim plate as shown in the drawing.
    SOMMER ASB Stahl Parking Barrier - LED1

  4. Install the cable as shown in the drawing and fasten to the shaft with 2 crosswise positioned cable binders.
    ⇒ This prevents the cable from being damaged over time by the movements of the boom
    SOMMER ASB Stahl Parking Barrier - LED2

  5. Route cables into the barrier housing through the base plate cable gland.
    | Green lighting| Red lighting
    ---|---|---
    GND| Green wire (GN)| Red wire (GN)
    +12 V| Brown wire (BN)| Brown wire (BN)

  6. Connect the wires to the control unit as specified in the connection diagram; see Page 58.

Alternative: Connection for traffic-light function
INFORMATION:
Optional relay (Relay) required.

  1. Plug the Relay into the Mufu1 slot.
  2. Wire as shown in the table.
    GND (control unit)| COM (Relay)
    ---|---
    Green wire, boom (GN)| NO (Relay)
    Red wire, boom (RD)| NC (Relay)
    Brown wire, boom (BN)| 12V (control unit)

Installing the support post

RISK OF CRUSH INJURIES TO HANDS!
Danger of crushing between the fork of the support post and the boom!

  • Keep out of the range of movement of the boom!
  • Never place your hand on the fork of the support post!
  1. To calculate the required length of the support post, see “Installation drawing” on page 14.
    SOMMER ASB Stahl Parking Barrier - Connection1

  2. Put the support post in place and mark the position for the 4 holes.

  3. Drill four holes Ø 8 or Ø 10 mm and at least 65 mm deep.

  4. Blow out holes with compressed air.
    INFORMATION:
    Only use permissible fastening materials. For recommended heavy-duty anchors, see “Installation drawing” on page 14
    SOMMER ASB Stahl Parking Barrier - Connection2

  5. Insert the heavy-duty anchors into the holes.

  6. Put the support post in place. Put 4 washers in place and tighten 4 nuts. With the spirit level, check the horizontal alignment of the support post and correct it if necessary.

Installing the floating support

SOMMER ASB Stahl Parking Barrier - Connection3

Aligning the position of the barrier

  1. Open the emergency release (see Page 28) and close the barrier.
    SOMMER ASB Stahl Parking Barrier - Connection4

  2. Open the barrier housing and loosen the 4 nuts so that the barrier can be aligned.

  3. Align the barrier so that it is parallel to the traffic lane and the boom is lying on the support post.

  4.  Tighten the 4 nuts as specified by the heavy-duty anchor manufacturer.

  5.  To calculate the position of the floating support, see “Installation drawing” on page 14.

  6.  Remove the cap from the boom.

  7. Hold the plate for screw connection of the floating support against the boom from below, in the position previously defined

  8. Use the plate as a template to mark the position of the bore holes.

  9. Drill holes in the marked positions.

  10. Push the plate for screw connection of the floating support into the boom until the bore holes in the plate are aligned with the holes drilled in Step 5.

  11. Bolt the floating support to the boom.

  12. Close the barrier and check the distance of the floating support to the ground. When closed, the distance must be approx. 2 cm.
    If necessary, correct the lower end positions of the barrier; see “Connection options” on page 33.

  13. Replace the cap on the boom.

Connection to the power mains

  •  The voltage of the power source must match the voltage listed on the type plate.
  • Check the mains supply line at the installation site and on the customer’s side in accordance with the valid regulations. Before connecting the barrier, perform an electrical test in accordance with the valid regulations.
  • If there is a danger that the mains voltage will have significant fluctuations, even for a brief period of time, the barrier must be supplied via a voltage stabiliser.
  • Operate barriers only with a permanently laid line protected by a fuse (16A, slow-acting).
  •  The mains connection must be in accordance with EN 12453 (omnipolar mains circuit breaker). For this purpose, install a lockable main switch (all-pole deactivation).
  •  As a PE wire is already connected to the PE terminal at the factory, the PE wire from the mains supply line must be connected to the terminal provided on the base plate.

DANGER!
If there is direct or indirect contact with live parts, dangerous current could flow through the body.
Electric shock, burns, or death may result.

  •  Before performing wiring work, make sure that the lines are de-energised. During wiring work, make sure that the lines remain de-energised (e.g. prevent reactivation).
  • Connection to the mains power must be performed by the personnel described in the chapter “Qualifications of personnel” on page 6.
    SOMMER ASB Stahl Parking Barrier - Connection6
  1. Open the door of the barrier housing.
  2.  Connect the mains supply line as shown in the connection overview (see Page 30).
  3.  Fit strain relief.

Initial operation

Safety information for initial operation

DANGER!
If there is direct or indirect contact with live parts, dangerous current could flow through the body.
Electric shock, burns, or death may result.

  • Before performing wiring work, make sure that the lines are de-energised. During wiring work, make sure that the lines remain de-energised (e.g. prevent reactivation).
  • Connection to the mains power must be performed by the personnel described in the chapter “Qualifications of personnel” on page 6.

WARNING
Risk of injury caused by the closing boom!

  • Keep out of the range of movement of the boom!

WARNING
Risk of injury through incorrect attachment of parts!

  • Before initial operation, check that the heavy-duty anchors and all screws are tightly and securely seated!

RISK OF CRUSH INJURIES TO HANDS!

  •  Risk of crushing at the lever system of the barrier when the hood and door of the barrier housing are open!

  • Follow the instructions on personal protective equipment!

  •  All work on the barrier must be carried out by qualified personnel!

  •  Before working on the barrier, always disconnect the system and secure it to prevent reactivation!

  • Perform installation only up to a maximum wind strength of 3 on the Beaufort scale (light wind).
    Initial operation of the barrier may not be carried out until:

  • all required monitoring devices (for example, photocells) are correctly connected.

  • all accident prevention measures have been taken.

  • all safety provisions are observed.

Adjusting the spring unit

WARNING
The adjustment of the spring unit is safety-relevant and must be performed by qualified personnel and with the utmost care.
If the setting of the spring unit is impermissibly high, persons could be injured and objects damaged.

  • Adjust the spring unit as described below to allow quick and reliable detection of obstacles.

WARNING!
If emergency release is performed by only one person, the emergency release button transfers considerable forces to the hand of the operating personnel.
Severe injuries may result!

  • Emergency release must be performed according to the instructions in this manual and only by two persons.
  • At least two persons are required for the adjustment of the spring unit.

The barriers are delivered without adjustment of the spring unit. The required spring force depends on the specific boom installed and the accessories mounted on it.
The barrier will only work correctly if the weight of the boom is compensated for by the tensile force of the springs; for this purpose:

  1. De-energise the barrier and secure it against reactivation.

SOMMER ASB Stahl Parking Barrier - operation

  1. Open the door of the barrier housing.

  2. Release the locking mechanism of the cover.

  3. Remove the top cover of the barrier.

  4.  Release the lock nuts of both springs.

  5.  Barrier emergency release, see”Emergency release” on page 28
    SOMMER ASB Stahl Parking Barrier - operation1

  6.  Bring the boom into a 45° angle using the emergency release button or by hand and hold it there.

  7. Adjust both nuts of the springs so that the boom remains at a 45° angle when released.
    SOMMER ASB Stahl Parking Barrier - operation2

  8. Tighten the lock nuts of both springs.

  9. Fit the top cover of the barrier and lock it.
    INFORMATION:
    If changes are made to the boom later, the spring force must be readjusted and the force values reprogrammed.
    This is necessary when shortening the boom, mounting accessories on the boom or exchanging the boom for a longer or shorter boom.
    Checking the movement range and end positions INFORMATION:
    • Movement range and end positions can be checked either with the handheld transmitter provided or with a button connected to Start 1 or Start 2.
    • In accordance with the regulations, the first movement of the barrier when the operating voltage is connected is always in the OPEN direction. If this is not the case, there is a fault in the electrical connection and the wiring of the limit stops and the motor connection must be checked. 1. Connect the voltage supply of the barrier.
    ⇒ “Status” LED flickers

  10. Press button 1 on the handheld transmitter briefly.
    ⇒ The barrier opens until the OPEN end position is reached, or it is already open.
    ⇒ “Limit Open” LED lights up red.
    ⇒ Warning light double-blinks.

  11. Press button 1 on the handheld transmitter again.
    ⇒ End position is confirmed.
    ⇒ Barrier closes until the CLOSE end position is reached.
    ⇒ “Limit Close” LED lights up.
    ⇒ Warning light double-blinks.

  12.  Press button 1 on the handheld transmitter again.

  13.  If necessary, set the end positions of the barrier to the desired positions.
    ⇒ If the end positions are already correct, continue at chapter “Programming the force values and end positions” on page 24

Setting the end position (optional)

NOTE!
The motor may be damaged if the end positions are not set correctly!

  1. De-energise the barrier and secure it against reactivation.
    SOMMER ASB Stahl Parking Barrier - operation4

  2. Open the door of the barrier housing.

  3. To adjust the upper end position (OL), loosen the nuts (width across flats 8) and move them in the oblong holes.
    • In the – direction, the movement range is shortened
    • In the + direction, the movement range is extended
    WARNING
    There are reed sensors for the barrier control system located under the nuts.
    If the nuts are tightened too strongly, the reed sensors will be destroyed and irreparable damage to the barrier may result.
    • Tighten the nuts (width across flats 8) only slightly.
    SOMMER ASB Stahl Parking Barrier - operation5

  4. To adjust the lower end position (CL), loosen the nuts (width across flats 8) and move them in the oblong holes.
    • In the – direction, the movement range is shortened
    • In the + direction, the movement range is extended

  5. Check the movement range and end positions of the barrier; see “Checking the movement range and end positions” on page 23

Setting the swivel range (optional)
INFORMATION!
During adjustment of the swivel range, the angle between the two end positions changes only minimally. Both end positions are pushed evenly in one direction.

  1. De-energise the barrier and secure it against reactivation.
    SOMMER ASB Stahl Parking Barrier - operation6

  2. Open the door of the barrier housing.

  3. Loosen both nuts (width across flats 22).
    SOMMER ASB Stahl Parking Barrier - operation7

  4. Insert a screwdriver into the bore hole of the clamping element. Turn the clamping element.
    • In the – direction, the swivel range changes toward the lower end position.
    • In the + direction, the swivel range changes toward the upper end position.

  5. Tighten both nuts (width across flats 22).

  6. Check the movement range and end positions of the barrier; see”Checking the movement range and end positions” on page 23

Programming the force values and end positions

WARNING
In programming mode, the barrier moves with full force.
This poses a high risk of injury to persons and animals.

  • Programming runs must be carried out under supervision and with a clear view of the movement area of the boom.

INFORMATION!

  •  The barrier has automatic obstacle recognition. The control unit memorises the required force during the barrier movements in both directions and stores them automatically when the end positions are reached.
    For this reason, a control unit reset must first be carried out.

  •  If an obstacle is detected during programming of the end positions and force values, the barrier stops or stops and reverses.
    If this happens, check the movement range, mechanism, spring tension and weight compensation of the barrier to prevent damage.

  •  Force values and end positions can be programmed either with the handheld transmitter provided or with a button connected to Start 1 or Start 2.

SOMMER ASB Stahl Parking Barrier - operation8

  1. Press and hold the “Reset” button for 10 seconds (control unit reset); see “Resetting the control unit” on page 38
    ⇒ Safety devices, force values and end positions are deleted.

  2.  Press button 1 on the handheld transmitter briefly.
    ⇒ The barrier opens until the OPEN end position is reached, or it is
    already open.
    ⇒ “Limit Open” LED lights up
    ⇒ Warning light double-blinks.

  3.  Press button 1 again briefly.
    ⇒ End position is confirmed.
    ⇒ Barrier closes until the CLOSE end position is reached.
    ⇒ “Limit Close” LED lights up.
    ⇒ Warning light double-blinks.

  4. Press button 1 again briefly.
    ⇒ End position is confirmed.
    ⇒ Barrier automatically starts the programming process for the force values.
    • Barrier opens
    • Barrier closes
    • Barrier opens
    ⇒ Force values are programmed.
    ⇒ Barrier is ready for operation.

INFORMATION!
The operating forces can be changed with SOMlink and a WiFi-enabled end device.

Obstacle detection event
INFORMATION!
An obstacle detection event takes place when the boom encounters an obstacle.
Two different obstacle detection events can occur during programming.
Obstacle detection event during programming of end positions
The barrier encounters an obstacle during the programming run for the end positions.

⇒ The barrier stops.
⇒ The warning light blinks briefly and repeatedly

  1.  Press button 1 on the handheld transmitter briefly.
    ⇒ The barrier opens until the OPEN end position is reached.
    ⇒ “Limit Open” LED lights up.
    ⇒ Warning light blinks.

  2.  Remove obstacle.

  3. Continue programming of the end positions “Programming the force values and end positions” on page 24.

Obstacle detection event during programming of force values
The barrier encounters an obstacle during the programming run for the force values.

⇒ The barrier stops and reverses a short distance.
⇒ The warning light blinks briefly and repeatedly.

  1.  Press button 1 on the handheld transmitter briefly.
    ⇒ The barrier opens until the OPEN end position is reached.
    ⇒ “Limit Open” LED lights up.
    ⇒ Warning light blinks

  2.  Remove obstacle.

  3. Continue programming of the end positions “Programming the force values and end positions” on page 24

Operation and control

Safety information on operation

DANGER!
If there is direct or indirect contact with live parts, dangerous current could flow through the body.
Electric shock, burns, or death may result.

  •  Before performing wiring work, make sure that the lines are de-energised. During wiring work, make sure that the lines remain de-energised (e.g. prevent reactivation).
  •  Connection to the mains power must be performed by the personnel described in the chapter “Qualifications of personnel” on page 6.

WARNING
Risk of injury caused by the closing boom!

  •  Keep out of the range of movement of the boom!

WARNING
Risk of injury through incorrect attachment of parts!

  • ¾ Before initial operation, check that the heavy-duty anchors and all screws are tightly and securely seated!

WARNING
Risk of injury caused by a torn-off boom!

  •  If wind strengths are higher than specified in the technical data:
    – Close the barrier and de-energise it.
    – Remove the boom.

WARNING
Risk of injury and damage following a lightning strike:

  •  Following a lightning strike, have the barrier tested by an electrician and if necessary, have it repaired.

RISK OF CRUSH INJURIES TO THE BODY!
Danger of crush injuries
Observe a minimum distance of 0.5 m between the boom and surrounding objects!

RISK OF BURNS!
The surface of the motor heats up during operation!

  • Allow the surface of the motor to cool before touching it!

RISK OF CRUSH INJURIES TO HANDS!

  • Install the barrier housing without the boom!
  • Follow the instructions on personal protective equipment!

RISK OF CRUSH INJURIES TO HANDS!

  • Risk of crushing at the lever system of the barrier when the hood and door of the barrier housing are open!

  •  Follow the instructions on personal protective equipment!

  • During normal operation:
    – the upper cover of the barrier must be in place and locked, and
    – the door of the barrier housing must be closed and locked.

  • An open barrier housing poses the following hazards:
    – tension springs under tension,
    – crushing and shearing points in the vicinity of the actuating connecting rod and the linkage.

  • When the barrier housing is open, protect the control unit and mains supply line against moisture.

  • Operate the barrier only when all safety devices are present and fully functional. As soon as a safety device is not functional, the barrier must be taken out of operation until the malfunction has been properly eliminated.

  • Do not allow several vehicles to pass through the barrier at once.

  • Do not drive through the barrier until it has opened completely.

  •  During operation, never hold the boom or reach into moving parts.

  • Children must never play with or use the barrier, even under supervision.

  •  Keep children away from the barrier.

  •  During the opening and closing procedures, no people or objects may be in the vicinity of the boom.

  •  The opening and closing procedures must be observed by the user.

  •  Do not place objects on the barrier housing or boom.

  •  Do not climb onto the barrier.

  •  The surface temperature of the motor may rise to 80° C, resulting in a risk of burns.

Automatic closing function

DANGER!
Failure to observe these instructions can lead to dangerous situations resulting in serious injuries.

  • Operation with automatic closing must comply with EN 12453.
    This is a legal requirement.
    In countries outside the EU, the relevant safety regulations must be observed.

  •  The installation of a photocell is mandatory for operation with automatic closing. The automatic closing function does not work without a connected photocell.

  •  Never reach into moving parts!

  • Keep persons and animals away from the movement area of the barrier!

  • Keep children away from the barrier!

  •  Always keep the moving barrier in sight!

  •  Do not pass through the barrier until it has opened completely!

In the case of the automatic closing function, the barrier closes automatically after a set hold open time. The hold open time is counted down starting when the BARRIER OPEN end position is reached. If another opening command is issued during the hold open time, the hold open time restarts.
The barrier can be opened, but not closed with a command device. While it is opening, the barrier cannot be stopped using a command device.
If an opening command is given again during automatic closing of the barrier, the barrier opens completely and the hold open time restarts.

INFORMATION!

  • The hold open time set at the factory is 60 seconds from the end position.
  • This value can be changed via SOMlink.
  • The setting range for the hold open time is 10 – 120 seconds.
  • A shortening of the hold open time to 5 seconds after passing the photocell is set at the factory.

Setting the automatic closing function:

DIP switch ON OFF
1 Activated Disabled

Setting the hold open time manually

  1. Close the barrier.

  2. If necessary, open the housing door.

  3.  Check that DIP switch 1 is in “OFF” position.

  4. First, press and hold the RADIO button. With the button pressed, set DIP switch 1 to “ON” position.
    ⇒ LEDs CH1 + CH3 and CH2 + CH4 light up alternately in pairs for one second in each case. With each alternation, the hold open time is extended by one second.
    SOMMER ASB Stahl Parking Barrier - operation12

  5. Count off the hold open time by counting the alternations of the LEDs.
    Release the RADIO button when the desired duration has been reached.

Early warning time
The warning light blinks during the pre-warning time to warn users of the opening and closing of the barrier.
INFORMATION!

  •  The pre-warning time can be set separately via SOMlink for the directions of movement OPEN and CLOSE.
  • The setting range for the pre-warning time is 0 – 65 seconds.
  • The progress of the pre-warning time is displayed by the blinking warning light.

Power-saving mode
To save energy, the control unit switches to power-saving mode after 60 seconds.
Connected accessories, e.g. 8k2 safety contact strips or photocells, are deactivated in power-saving mode.
With the next command via the buttons or the radio control system, the barrier and the accessories are reactivated.
Setting power-saving mode:

DIP switch ON OFF
2 Disabled Activated

Resetting the ALARM safety input

SOMMER ASB Stahl Parking Barrier - icon23

  1. Disconnect the barrier from the mains voltage.
  2.  Check that it is disconnected from the voltage supply.
  3.  Inspect the barrier for damage and repair any damage found.
  4. Reset fire alarm system (close contact)
  5. Restore the mains power supply
  6. Execute a command using the button.

Emergency release

WARNING!
Uncontrolled upward movement of the boom!
The emergency release must never be opened on the barrier if the boom has been damaged (e.g. by a vehicle driving into it).

  • The defective boom must be replaced before the emergency release is opened on the barrier!

WARNING!
If emergency release is performed by only one person, the emergency release button transfers considerable forces to the hand of the operating personnel.
Severe injuries may result!

  • Emergency release must be performed according to the instructions in this manual and only by two persons.

RISK OF CRUSH INJURIES TO HANDS!

  •  Risk of crushing at the lever system of the barrier when the hood and door of the barrier housing are open!
  • Follow the instructions on personal protective equipment!
  1. De-energise the barrier and secure it against reactivation.
    SOMMER ASB Stahl Parking Barrier - operation13

  2. Open the door of the barrier housing.

  3. Have a second person hold the boom. At the same time, press the emergency release button and turn it about 60° to the right or left.
    ⇒ The barrier has been released.
    SOMMER ASB Stahl Parking Barrier - operation14

  4. Open or close the barrier with the emergency release button. The second person must assist by moving the boom.

  5. When the desired boom position is reached, turn the emergency release button about 60° towards the right or left, to the centre position.
    ⇒ The emergency release button snaps back.
    ⇒ The barrier has been locked.

Control unit

Safety information for control unit

DANGER!
If there is direct or indirect contact with live parts, dangerous current could flow through the body.
Electric shock, burns, or death may result.

  •  Before performing wiring work, make sure that the lines are de-energised. During wiring work, make sure that the lines remain de-energised (e.g. prevent reactivation).
  • Connection to the mains power must be performed by the personnel described in the chapter “Qualifications of personnel” on page 6.
  •  Protect the control unit against moisture.
  • Do not apply an external voltage to the connections of the control unit or the control unit will immediately be permanently damaged.
  • Only use the control unit provided by SOMMER Antriebs- und Funktechnik GmbH; all other control units would be damaged or would damage the operator.

Connection overview

SOMMER ASB Stahl Parking Barrier - Control unit

1) Transformer
2) Slot for Accu
3) Slot for Memo
4) Output 24 V DC max. 300 mA (600 mA*)
5) Output 12 V DC max. 150 mA
6) Multi-function relay slot
7) Multi-function relay slot
8) External button 1, potential-free
9) External button 2, potential-free
10) Emergency stop / targeted STOP, potential-free
11) Normally closed contact NC, contact evaluation unit of an induction loop

as object protection, potential-free
12)| Normally open contact NO, contact evaluation unit of an induction loop as opener, potential-free
13)| Timer, potential-free
14)| Alarm safety input, potential-free
15)| Voltage supply 4-wire photocell 24 V DC, max. 100 mA
16)| 2-wire photocell, switching contact 4-wire photocell, 8k2 safety contact strip
17)| Warning light 24 V max. 3W
18)| Limit stop OPEN /CLOSE (wire colours, see Page 34)
19)| Motor (wire colours, see Page 34)
20)| Mains connection 220-240 V AC 50/60 Hz

*600 mA are only available if no further external 24 V and 12 V device is connected to the control unit.

Overview and flash sequences of the LEDs
The flash sequences provide information on malfunctions for the installer, the end customer and telephone support.

SOMMER ASB Stahl Parking Barrier - Connection diagram1

LIMIT OPEN (red) Off • Boom is not in OPEN end position
ON • Boom has reached the OPEN end position
LIMIT CLOSE (red) Off • Boom is not in CLOSE end position
On • Boom has reached the CLOSE end position
• Safety device in exterior interrupted/fault
MUFU 1 / MUFU 2 (green) Off • Multi-function relay not activated
On • Multi-function relay activated

A connection diagram can be found in Chapter “Connection diagram” on page 58

Connection options
Terminal blocks

3-pin terminal block
Supply voltage 220–240 V AC 50/60 Hz see “Connection to the power mains” on page 21

2-pin terminal block
Transformer primary side 220–240 V AC 50/60 Hz

2-pin terminal block
Transformer secondary side 24 V AC

4-pin terminal block 24 V output
DC max. 300 mA (600 mA*) Voltage supply for external accessories +24 V DC, GND 12 V output DC max. 150 mA Voltage supply for external accessories +12 V DC, GND

The 12 V and 24 V voltage sources are switched off when the control unit switches to power-saving mode.
*600 mA are only available if no further external 24 V and 12 V device is connected to the control unit.
6-pin terminal block START 1, START 2 and SAFETY
potential-free, e.g.: for external 3-way button OPEN – CLOSE – emergency stop with orange status LEDs Safety with status LED, green

START 1 = Pulse ≤ 2 sec
START 2 = Pulse ≤ 2 sec
SAFETY = emergency stop
Programmable via SOMlink
8-pin terminal block INDUC.1, INDUC 2, CLOCK and ALARM
potential-free
INDUC.1: Normally closed contact NC, contact evaluation unit of an induction loop as object protection, potential-free with status LED, orange
INDUC.2: Normally open contact NO, contact evaluation unit of an induction loop as opener, potentialfree with status LED,
orange CLOCK: For example, for timer or constant signal (barrier remains open as long as the signal is present) with status LED, orange ALARM: For example, for fire alarm system with status LED, green

INDUC.1 = Object protection
INDUC.2 = Open
CLOCK = Operating mode 1
(barrier opens with closed contact)
Programmable via SOMlink

4-pin terminal block
Photocell 2-wire, 4-wire or for 8k2 safety contact strip 2-wire:
Any polarity Signal COM with status LED, orange 4-wire:
24 V DC, max. 100 mA + 24 V DC GND Signal  COMWith status LED, orange 8k2 safety contact strip:
Signal COM With status LED, orange

2-pin terminal block
WARNING
Warning light 24 V DC, max. 3 W with status LED, orange

: Warning light blinks during movement
Programmable via SOMlink

3-pin terminal block LIMIT OPEN, LIMIT CLOSE limit stop
Right-closing barrier:
LIMIT OPEN: red wire LIMIT CLOSE: blue wire GND: green – yellow wire

Left-closing barrier:
LIMIT OPEN: blue wire
LIMIT CLOSE: red wire
GND: green – yellow wire
With status LED, red
2-pin terminal block
MOTOR
Wire colours:
right black
left red

Slots

BUZZER slot,
Buzzer terminal,

: Buzzer sounds during movement
: Programmable via SOMlink

MEMO slot
Memo terminal, (red housing)
memory expansion for 450 transmitter commands

USART slot
Terminal, e.g. home automation module

ACCU slot
Terminal for battery pack

: If the battery is low, the barrier opens.
: Programmable via SOMlink

MUFU 1 / MUFU 2 slots
Terminals for relay (potential-free changeover contact) or Output OC (open collector output)

: MUFU 1: Relay activated as long as the barrier is in OPEN end position. MUFU 2: Relay activated as long as the barrier is in CLOSE end position.
: Programmable via SOMlink

DIP switch
You can select different functions via the DIP switches. The following table summarises the various setting options.
INFORMATION!

  • All DIP switches are set to “OFF” in the factory settings
  • To prevent damage to the DIP switches or the circuit board, do not use sharp objects to change the position of the DIP switches.
DIP switch Function Effect
1 OFF Automatic closing
ON Activated
2 OFF  Power-saving mode
ON Deactivated
3 OFF No function
ON
4 OFF No function
ON

Factory setting

Radio
Safety information for the radio remote control

DANGER!
If there is direct or indirect contact with live parts, dangerous current could flow through the body.
Electric shock, burns, or death may result.

  •  Before performing wiring work, make sure that the lines are de-energised. During wiring work, make sure that the lines remain de-energised (e.g. prevent reactivation).
  • Connection to the mains power must be performed by the personnel described in the chapter “Qualifications of personnel” on page 6.
  • The radio remote control may only be used for equipment and/or systems where interference in the transmitter or receiver does not pose a risk to humans, animals or objects, or where the risk is covered by other safety devices.
  •  The radio remote control may only be used if the operator has a direct view of the barrier and when there are no persons or objects within the range of movement.
  • Store the handheld transmitter of the radio remote control in such a way that unintended operation e.g., by children or animals, is prevented.
  • The user of the radio system is not protected against interference due to other telecommunications equipment or devices (e.g.:. radiocontrolled systems that are licensed to operate in the same frequency range). If substantial interference occurs, please contact your appropriate telecommunications office which has radio interference measuring (radio location) equipment! ¾ Do not operate handheld transmitters near locations or installations that are sensitive to radio interference (e.g.: airports, hospitals).

Explanation of the radio channels

LED Radio channel Setting/function
1 CH 1 Pulse mode
2 CH 2 : Defined Stop

:  Lighting function, multi-function relay
3| CH 3| Defined OPEN
4| CH 4| Defined CLOSE

Programming the transmitter

INFORMATION!
If no transmission command is received within 30 seconds of pressing the Radio button, the radio receiver switches to normal operation.
1. Press the Radio button repeatedly to select the required radio channel.

  1.  Press the desired button on the transmitter until the previously selected
    LED (CH 1, CH 2, CH 3, CH 4) goes out.
    ⇒ LED goes out – programming is complete.
    ⇒ The transmitter has transferred the radio code to the radio receiver.

  2. Repeat the above steps to program additional transmitters.

INFORMATION!
Further transmitters cannot be programmed if all memory positions of the handheld transmitter are occupied.

If the memory capacity has been reached
A total of 40 handheld transmitter commands are available for all channels.
If an attempt is made to program additional transmitters, the red LEDs of radio channels CH 1 – CH 4 blink. If more memory positions are required, see “Information on Memo” below.
Information on Memo
The memory capacity can be extended to 450 handheld transmitter commands using the optional Memo accessory part. When plugging in the Memo, all available transmitters are transferred from the internal memory to the Memo and stored there. The Memo must remain plugged in on the control unit.
No more transmitters are then stored in the internal memory. Stored transmitters cannot be transferred from the Memo back to the internal memory.
All radio channels, including the memory of the Memo, can be deleted; see Page 37.

INFORMATION!
Delete the Memo on a new receiver.
Otherwise, all stored transmitters of an operator are deleted and must be reprogrammed.
Cancelling programming mode
• Press the Radio button until all LEDs are off or make no input for 30 seconds.
⇒ Programming mode is cancelled.
Deleting a transmitter button from the radio channel

  1. Press the Radio button repeatedly to select the required radio channel.
    Press and hold the Radio button for 15 seconds.
    ⇒ The LED flashes after 15 seconds.

  2.  Release the Radio button.
    ⇒ The radio receiver is now in deletion mode.

  3.  Press the transmitter button for which the command is to be deleted in the radio channel.
    ⇒ LED goes out
    ⇒ The deletion procedure has been completed.
    • Repeat the process for additional buttons as required.

Deleting a transmitter completely from the receiver

  1. Press and hold the Radio button for 20 seconds.
    ⇒ The LED flashes after 15 seconds
    ⇒ After another 5 seconds, the flash sequence changes to blinking.

  2. . Release the Radio button.
    ⇒ The radio receiver is now in deletion mode

  3.  Press any button on the transmitter that is to be deleted.
    ⇒ The radio receiver is now in deletion mode
    ⇒ LED goes out
    ⇒ The deletion procedure has been completed.
    ⇒ The transmitter is deleted from the radio receiver
    • Repeat the process for additional transmitters as required.

Deleting a radio channel in the receiver

  1.  Press the Radio button repeatedly to select the required radio channel.Press and hold the Radio button for 25 seconds.
    ⇒ The LED flashes after 15 seconds
    ⇒ After another 5 seconds, the flash sequence changes to blinking.
    ⇒ After another 5 seconds, the LED of the selected radio channel remains steady

  2. Release the Radio button.
    ⇒ The deletion procedure has been completed.
    ⇒ All programmed transmitters on the selected radio channel are deleted from the radio receiver

Deleting all radio channels in the receiver

  1. Press and hold the Radio button for 30 seconds.
    ⇒ The LED flashes after 15 seconds
    ⇒ After another 5 seconds, the flash sequence changes to blinking.
    ⇒ After another 5 seconds, the LED of the selected radio channel remains steady
    ⇒ After another 5 seconds, all LEDs light up

  2. Release the Radio button.
    ⇒ All LEDs are off after 5 seconds
    ⇒ All programmed transmitters are deleted from the receiver
    ⇒ Receiver is completely deleted; this also applies if the Memo is plugged in

Programming a second transmitter by radio (HFL)
Prerequisites for programming by radio
A handheld transmitter must already be programmed on the radio receiver.
The handheld transmitters used must be identical. This means, for example, that a Pearl can only be programmed on a Pearl and a Pearl Vibe on a Pearl Vibe.
The key assignment of handheld transmitter (A) that put the radio receiver into teach-in mode by radio is used for the new handheld transmitter (B) that is to be programmed.
The already-programmed transmitter and the new transmitter to be programmed must be situated in the range of the radio receiver.
Example:

  1. Button 1 on radio channel 1 and button 2 on radio channel 2 have been programmed by handheld transmitter (A).
    ⇒ The newly programmed handheld transmitter (B) adopts the button assignment of handheld transmitter (A): Button 1 on radio channel 1, button 2 on radio channel 2.

Restriction
The following setting is not possible:

  • The targeted teach-in of a selected handheld transmitter button on a radio channel.

SOMMER ASB Stahl Parking Barrier - channels5

  1.  Press buttons 1 and 2 of a programmed handheld transmitter (A) for 3 – 5 seconds until the LED on the handheld transmitter briefly lights up.
    ⇒ Warning light and LEDs CH1 and CH2 blink

  2.  Release buttons 1 + 2 of the handheld transmitter (A).
    ⇒ If a radio command is not transmitted within another 30 seconds, the radio receiver switches over to normal mode

  3.  Press any key, e.g. (3) on the new handheld transmitter (B) to be programmed.
    ⇒ LEDs CH1 and CH2 go out

Resetting the control unit

SOMMER ASB Stahl Parking Barrier - Resetting the control
unit

INFORMATION!
A SOMlink and a WiFi-enabled device are required to reset all parameters to the factory settings.

Resetting the safety devices

  • Press the green Reset button for 1 second.
    ⇒ Reset of the connected safety devices.
    ⇒ Subsequently attached safety devices are detected.

Deleting the force values

  • Press the green Reset button for 5 seconds until the green status LED blinks slowly.
    ⇒ Force values are deleted.

Deleting force and position values

  •  Press the green Reset button for 10 seconds until the green status LED blinks quickly.
    ⇒ Force and position values deleted.

Reset

  • Press the green Reset button for 15 seconds until the green LED goes out.
    ⇒ Reset is performed.

SOMlink
SOMlink makes it possible for qualified specialists to change many functions and settings. These include force and speed values as well as operating parameters and other convenient functions.
If you would like to make changes, contact your specialist dealer.

INFORMATION!
SOMlink is a combination of an additional device and a web-based application for changing gate functions.
Since safety-relevant values can also be changed, SOMlink is only sold to qualified specialists.
All changes to settings via the SOMlink are logged.

Regular testing and maintenance

INFORMATION:
Using this testing schedule, test the barrier at the required intervals and document and archive the test result!

  •  Test interval using this testing schedule: annual.
  •  The entire barrier is maintenance-free.
Testing To be carried out by Date and tester
Obstacle recognition

Stop the boom during closing at a closing angle of about 45° with a 2-metre high object.| Specialist
Emergency release
Proceed as described in “Fmergency release” on nage 28.| Specialist|
Visual inspection
Inspect the boom and attached parts such as support post and floating support as well as the inside and outside of the barrier housing for obvious defects, damage from vehicles, environmental influences or vandalism.| Specialist|
Safety devices| |
Test the safety devices and repair as necessary.| Specialist|
Spring tension| |
Check the spring tension and correct if necessary; see “Adjusting the wring unit” on oage 22.| Specialist|
Mechanical systems| |
Check the mechanical system of the barrier for correct functioning and repair as necessary.| Specialist|
Electrical system| |
Check the electrical connections and cables for firm seating and damage and repair as necessary.| Trained electrician|

Troubleshooting

Safety information for troubleshooting

DANGER!
If there is direct or indirect contact with live parts, dangerous current could flow through the body.
Electric shock, burns, or death may result.

  •  Before performing wiring work, make sure that the lines are de-energised. During wiring work, make sure that the lines remain de-energised (e.g. prevent reactivation).
  • Connection to the mains power must be performed by the personnel described in the chapter “Qualifications of personnel” on page 6.

Changing the fuse

  1. De-energise the barrier and secure it against reactivation.

SOMMER ASB Stahl Parking Barrier - Changing the fuse

  1. Open the barrier housing.

  2.  Open the control unit housing.

  3. Change the defective fuse (1 A fast-acting fuse).

  4. Close the control unit housing.

  5. Close the barrier housing.

Replacing springs

RISK OF CRUSH INJURIES TO HANDS!
Risk of crushing at the lever system of the barrier when the hood and door of the barrier housing are open!

  •  All work on the barrier must be carried out by qualified personnel!
  •  Before working on the barrier, always disconnect the system and secure it to prevent reactivation!
  • Install the barrier housing without the boom!
  • Follow the instructions on personal protective equipment!

INFORMATION:
To ensure problem-free operation, we recommend that you replace both springs!

  1. De-energise the barrier and secure it against reactivation.
    SOMMER ASB Stahl Parking Barrier - Changing the fuse2

  2. Open the door of the barrier housing and release the lock of the cover.

  3. Remove the top cover of the barrier.
    SOMMER ASB Stahl Parking Barrier - Changing the fuse3

  4. Loosen both nuts of the broken springs.

  5. Remove the broken springs.
    SOMMER ASB Stahl Parking Barrier - Changing the fuse4

  6. Insert new springs and fasten with nuts.

  7. Adjust the spring unit; see “Adjusting the spring unit”

  8. Close the barrier housing.

Fault – cause – elimination

  • All work within the scope of troubleshooting may only be performed by trained personnel; see “Qualifications of personnel” Personnel must be familiar with the special risks which arise when protective devices are disabled and must know which special safety measures must be taken while carrying out troubleshooting.
  • Shut down all command devices so that the barrier does not move in an uncontrolled manner.
  •  Safety devices may only be bypassed, switched off or removed if it has been guaranteed by suitable measures that the barrier does not give rise to any risk despite this.
  •  Secure the working area during troubleshooting. Use boundary tape and warning signs. Never leave the working area unattended.
  • Make sure that no tools or other aids are left in or on the barrier after completing troubleshooting.
  • For work performed above body height, use suitable, tested, and stable climbing aids.
  •  Before starting operation again, mount and check all safety devices.

SOMMER ASB Stahl Parking Barrier - Connection diagram2

SOMMER ASB Stahl Parking Barrier - Connection diagram3

If you cannot find the malfunction in the table and eliminate it, carry out the following measures.

  • Perform a control unit reset and then reprogramme the force values
  • Set all DIP switches to OFF
  • Disconnect connected accessories (e.g. photocell) and reconnect the jumper for a safety connection.
  • Check all connections

If you encounter other problems, please contact your specialist dealer, a customer service company: https://www.sommer.eu/de/servicepartner.html, our free service hotline:

+49 (0)900-1800150
(0.14 euros/minute from a German landline, mobile prices may vary) or visit our website at: https://www.sommer.eu/de/

Disassembly and disposal

Safety information for disassembly

During disassembly, additional dangers that do not occur during operation must be expected since the safety devices are to some extent disabled.

  •  Perform disassembly only up to a maximum wind strength of 3 on the Beaufort scale (light wind).
  •  At least two people are required for the entire disassembly.
  •  Physically disconnect the power supply lines and discharge energy buffers.
  •  For disassembly work performed above body height, use suitable, tested, and stable climbing aids. Never use the barrier or parts of the barrier as climbing aids.
  •  The disassembly of the barrier and all work on the electrical system may only be performed by the personnel described in the chapter “Qualifications of personnel” on page 6.

DANGER OF TIPPING!
The barrier may tip during disassembly.
This can cause injuries and damage to the barrier.

  •  Transport and disassembly must be performed by two persons and using suitable transport equipment.

Storage after disassembly
If the barrier is to be put into intermediate storage after disassembly, observe the provisions and regulations for storage listed in “Transport / Unloading / Storage” on page 12.
If possible, store the control unit of the barrier separately.
Description of the disassembly work

DANGER!
If there is direct or indirect contact with live parts, dangerous current could flow through the body.
Electric shock, burns, or death may result.

  •  Before starting disassembly, set the main switch to “0,” secure it with a padlock, and attach a warning sign.

RISK OF CRUSH INJURIES TO HANDS!

  • Risk of crushing at the lever system of the barrier when the hood and door of the barrier housing are open!
  • Follow the instructions on personal protective equipment!

RISK OF BURNS!
Wait at least five minutes after deactivation so that the motor can cool down and the capacitors lose their voltage.

  1. Disconnect the mains supply line and remove it.
  2. Remove the control unit.
  3.  Disassemble the connected accessories and remove the control unit.
    **Flat boom 400, 580 and LED 500

**

  1.  Remove the boom in the vertical opening position.

  2.  Release the support plate and remove the boom.

  3.  Release and remove the adapter plate.

  4. Open the barrier housing and loosen 4 nuts.

  5. Remove the nuts, washers, and U-profiles.

  6. Remove the barrier housing.

Disassembly and disposal

Disposal
Procedure for the disposal of the barrier, parts, operating material and auxiliary materials is to some extent prescribed by law. Precise information can be obtained from the responsible public administration authorities (e.g. water boards and environmental protection offices on a federal and state or provincial level).
Only deliver goods to be disposed of to authorised disposal facilities.
WARNING
Environmental damage in the case of incorrect disposal!

  • Electrical waste, electronic components, lubricants and other auxiliary materials must be treated as hazardous materials and may only be disposed of by approved specialist companies.

Declaration of Conformity

for the installation of a machine in accordance with the in accordance with the Machinery Directive 2006/42/EC, Annex II, Section 1 A
SOMMER Antriebs- und Funktechnik GmbH
Hans – Böckler – Straße 21 – 27
73230 Kirchheim unter Teck
Germany
hereby declares that the barrier systems
ASB Alu
ASB Stahl

have been developed, designed and manufactured in conformity with the

  • Machinery Directive 2006/42/EC
  • Low Voltage Directive 2014/35/EU
  • Electromagnetic Compatibility Directive 2014/30/EU
  • RoHS Directive 2011/65/EU

The following standards were applied:

  • EN ISO 13849-1, PL “C” Cat. 2 Safety of machines – safety-related parts of controls
    – Part 1: General design guidelines

  • EN 60335-1, where applicable Safety of electrical appliances / operators for gates

  • EN 61000-6-3 Electromagnetic compatibility (EMC) – interference

  • EN 61000-6-2 Electromagnetic compatibility (EMC) – interference resistance

The following requirements of Annex 1 of the Machinery Directive 2006/42/EC are met:
1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.2, 1.2.3, 1.2.4, 1.2.6, 1.3.2, 1.3.4, 1.3.7, 1.5.1, 1.5.4, 1.5.6, 1.5.14, 1.6.1, 1.6.2, 1.6.3, 1.7.1, 1.7.3, 1.7.4
The special technical documentation was prepared in accordance with Annex VII Part B and will be submitted to regulators electronically on request.
The incomplete machine is intended solely for installation in a door system to form a complete machine as defined by the Machinery Directive 2006/42/EC. The gate system may only be put into operation after it has been established that the complete system complies with the regulations of the above EC Directives.
The undersigned is responsible for compilation of the technical documents.

Kirchheim, 20 March 2021

Handover protocol

INFORMATION:
Technical Regulation for Workplaces ASR A1.7 stipulates that all power- activated gate and barrier systems must undergo safety testing once per year, irrespective of when the system was put on the market.
The test specifications listed in ASR A1.7 must be applied in a manner appropriate for a barrier system.
The requirements must be met from initial operation onwards and compliance with the requirements must be tested at least once per year by a safety test of the entire system including all safety-relevant additional components and carried out by a qualified specialist.
A separate safety test is mandatory in the event of significant changes, e.g. changes in operating mode, use of non-identical components etc.
INFORMATION:
A qualified specialist is a person who, due to his/her training and experience, has sufficient knowledge in the field of power-activated gates and barriers and who is familiar with the governmental health and safety regulations, UV regulations, directives and  generally accepted engineering practice (e.g. standards) to the degree that he/she can assess the operational safety of power-activated gates and barriers.
INFORMATION:
Safety testing is not to be equated with maintenance!
INFORMATION:
Safety testing is carried out using the checklist below, the results of the test must be documented in the checklist, kept at the operation location of the barrier system and made available for inspection.
Subject to technical changes.

  1.  Installer of the system:
    Company
    Address
    Phone
    E-mail
    Contact

  2. Operator of the system:
    Company
    Address
    Phone
    E-mail
    Contact

  3.  Location of the system:
    Company
    Address

  4. Installation / initial operation:
    Installed on
    Installer / qualified specialist (name)
    Initial operation on
    Initial operation by (name)
    Acceptance of the system by the operator: Date……… Name

  5.  Area of application:
    Commercial
    Private
    Exit
    Entrance
    Exit / entrance
    Number of cycles/day

  6. Technical data:
    Model
    ASB Alu
    ASB Stahl
    Right-closing
    Left-closing
    Closing direction
    Serial number
    Year of manufacture
    Item Number
    Boom length     ………, ………m

  7.  Installed accessories:
    Floating support
    (from 4 m boom length)
    Support post
    (from 4 m boom length)
    External warning light
    Main switch (all-pole deactivation)
    External antenna
    OtherYes| | No|
    ---|---|---|---
    Yes| | No|
    Yes| | No|
    Yes| | No|
    Yes| | No|

  8. Safety devices:
    Photocell
    Induction loop
    OtherYes| | Installation height:| No|
    ---|---|---|---|---
    Yes| | Quantity:| No|

  9.  Control unit:
    Buttons without self-locking (dead man’s switch)
    Pulse control with view of the system
    Pulse control without view of the system (remote control)
    Automatic mode
    Other

  10. Setting of the barrier:

  11. Induction loops:
    SOMMER ASB Stahl Parking Barrier - Connection diagram5

  12. Signatures:
    The barrier system and its accessories were properly installed and the settings specified by the customer were made. The signing operator has been trained in the correct operation and maintenance of the barrier system and its accessories and in particular, has been made aware of the safety instructions. The barrier system may only be operated with a view of the barrier. All users of the system must be informed of this.
    The following documents have been created and handed over:
    • Installation and Operating Manual for the barrier system
    • Installation and Operating Manuals for the installed accessories
    • Test report of initial operation

Signatures

SOMMER ASB Stahl Parking Barrier - icon58

Test report

Test report for power-activated barriers
(Testing in accordance with ASR A1.7)
Company carrying out test
Date
Information on the system:
Operator of the system:
Company
Address
Phone
E-mail
Contact
Location of the system:
Company
Address
Model:
Year of manufacture:
Serial number:

n.o. = no objections
o. = objection
n.p. – not present
Mechanical systems
Barrier housing (damage / attachment)
Boom (damage / attachment)
Compensating springs (damage / attachment / weight compensation)
Emergency release (function / damage)
Seals (condition / wear)

Operator
Motor (attachment /electrical connection / function / noise)
Boom (damage / attachment)

Control unit / electrical system
Mains connection
Control buttons
Limit stop OPEN (function / damage)
Limit stop CLOSE (function / damage)
All-pole mains circuit breaker (in accordance with EN 12453)
Evaluation of induction loops (function: close, open, presence)

  1. Induction loop (function / damage)
  2. Induction loop (function / damage)

SOMMER ASB Stahl Parking Barrier - icon62

Photocell (function / damage)
Safety devices
Safety distances between moving and fixed parts in the surroundings

Compliance with operating forces

SOMMER ASB Stahl Parking Barrier - Test report

Maximum operating force complied with (max. 400 N)
Dynamic time complied with (max. 750 ms)
Static time complied with (max. 5 s)

System is labelled
Completeness/legibility

Documentation for the system is available
Installation and Operating Manual
Handover protocol
Inspection book

SOMMER ASB Stahl Parking Barrier - icon66

Brief instructions

CAUTION
These brief instructions do not replace the Installation and Operating Manual! The safety instructions and warnings in the Installation and Operating Manual must be complied with!

Emergency release

SOMMER ASB Stahl Parking Barrier - Brief instructions

INFORMATION!
A SOMlink and a WiFi-enabled device are required to reset all parameters to the factory settings.
Resetting the control unit

  • Press the green Reset button for 15 seconds until the green LED goes out.
    ⇒ Reset is performed.

Overview of the DIP switches

DIP switch Function Effect
1 OFF Automatic closing
ON Activated
2 OFF  Power-saving mode
ON Deactivated
3 OFF No function
ON
4 OFF No function
ON

Connection diagram

SOMMER ASB Stahl Parking Barrier - Connection diagram

  • The 12 V and 24 V voltage sources are switched off when the barrier switches to power-saving mode.
1) Transformer
2) Slot for Accu
3) Slot for Memo
4) Output 24 V DC max. 300 mA (600 mA*)
5) Output 12 V DC max. 150 mA
6) Multi-function relay slot
7) Multi-function relay slot
8) External button 1, potential-free
9) External button 2, potential-free
10) Emergency stop / targeted STOP, potential-free
11) Normally closed contact NC, contact evaluation unit of an induction loop

as object protection, potential-free
12)| Normally open contact NO, contact evaluation unit of an induction loop as opener, potentialfree
13)| Timer, potential-free
14)| Alarm safety input, potential-free
15)| Voltage supply 4-wire photocell 24 V DC, max. 100 mA
16)| 2-wire photocell, switching contact 4-wire photocell, 8k2 safety contact strip
17)| Warning light 24 V max. 3W
18)| Limit stop OPEN / CLOSE (wire colours see Page 34)
19)| Motor (wire colours, see Page 34)
20)| Mains connection 220-240 V AC 50/60 Hz

For colours of the lines on motor and limit stop connection, see “Connection options” on page 33

  • 600 mA are only available if no further external 24 V and 12 V device is connected to the control unit.
  •  The 12 V and 24 V voltage sources are switched off when the barrier switches to power-saving mode.

SOMMER Antriebs- und Funktechnik GmbH
Hans-Böckler-Straße 21-27
D-73230 Kirchheim/Teck
Germany
info@sommer.eu
www.sommer.eu
© Copyright 2021
All rights reserved

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals