Balboa TP700 Topside Control User Guide
- June 15, 2024
- BALBOA
Table of Contents
- TP700 Topside Control
- THANK YOU
- THE MAIN SCREEN
- USER INTERFACE
- SET TIME-OF-DAY
- 1 – Run spa devices by pressing any of these buttons (G).
- 2 – Run spa devices from the Spa screen by following these steps.
- ADJUSTING FILTRATION
- SPA BEHAVIOR
- HEAT SETTINGS
- FILL IT UP!
- SETTINGS
- PANEL MESSAGES
- PANEL MESSAGES
- DIAGNOSTICS
- FORCING A MANUAL GFCI TRIP TEST
- WARNING
- INFORMATION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TP700 PANEL
User Guide
TP700 Topside Control
Your Single Source Solution
THANK YOU
for using Balboa Water Group spa controls.
TP700 Video Tutorials
www.BalboaWater.com/TP700-Quick-Tips
Home Page
TP700 PANEL
BP CONTROL SYSTEM Software Version: 7.0 and later
THE MAIN SCREEN
MAIN SCREEN ICONS
A – Temperature Range
High: H
Low: L
B – Heat Mode
Ready: R
Rest: IR
Ready-in-Rest: RR
C – Ozone Running: O1
D – Time-of-Day
E – Filter Cycles
Filter Cycle 1: F1
Filter Cycle 2: (Optional Feature)
Filter Cycles 1 & 2:
F – Cleanup Cycle (Optional Feature)
G – Panel Locked and/or Settings Locked
H – WiFi (Local or Cloud Connection)
I – Navigation Arrow
J – Heat Status
K – Selection Box
L – Message (May Appear)
I Information
R Reminder
Error – Normal Error or Warning
Error – Spa will not function until fixed
M – Water Temperature
Fahrenheit temperatures are displayed without decimal points. For example,
100° F is displayed as 100.
Celsius temperatures are displayed with decimal points. For example, 37.5° C
is displayed as 37.5.
N – Water Temperature Bar
O – Set Temperature Arrow
Important information about the current state of your spa is displayed on the
Main screen.
NOTE:
Not all control systems are configured the same. Spa devices, Settings, and
various menu items may vary on your control panel.
USER INTERFACE
Spa Device Buttons
These buttons control various spa devices, such as Jets, Lights and/or
Blowers.
Navigation Buttons
Navigate the entire menu structure with the 5 navigation buttons on the
control panel.
The names shown to the right refer to the navigation buttons in this user
guide. The names will be written in uppercase letters.
Operating or changing a selected item on the panel screen is generally done
with the SELECT button (center button).
Selection Box
The Selection box is a fundamental navigation tool. It indicates a selected
item. Move the selection box by pressing the UP, DOWN, LEFT, RIGHT Navigation
buttons. When an item is selected, press the SELECT navigation button to act
upon the selected item. The next page shows various examples of selected items
(C, I, L).
Menu Navigation
The right Navigation arrow (A) on the Main screen indicates a menu. Press the
RIGHT navigation button to enter that menu.
A selection box (C) indicates that a menu item is selected. When a menu item
is selected, its name appears at the top of the screen (B). In this example
the Settings menu is selected. Press the SELECT navigation button to enter the
Settings window (E).
Navigation Arrows
Navigation arrows (D, F, H, M) indicate more menu items. Each navigation arrow
corresponds to a navigation button (view page 8). For example, the right
Navigation arrow (D) corresponds to the RIGHT navigation button. The left
Navigation arrow (M) corresponds to the LEFT navigation button, etc.
Back Button
Use the Back button (L) to navigate back in the menus. Use the navigation
buttons to select the Back button. The Selection box (L) indicates that the
Back button is selected. Press the SELECT navigation button.
On/Off Switches
In this example the Reminders setting has an On/ Off switch (G). When the
Reminders setting line is selected, press the SELECT navigation button to turn
the switch On/Off. In this example the switch is On (G).
Select, Save, Cancel
Select one of these columns (J) with the RIGHT and LEFT navigation buttons.
Change the selected setting with the UP and DOWN navigation buttons. After you
change the settings, choose the Save button ( I ) and press the SELECT
navigation button. After you press SELECT, the change is complete. If you
decide to cancel your new settings, select the Cancel button (K) and press the
SELECT navigation button.
Navigate the Main menu
-
Start from the Main screen (A), and press the RIGHT navigation button to enter the Main menu.
If the Selection box (B) is on the Message icon, you need to press the RIGHT navigation button twice to enter the Main menu. -
Spa is the first item in the Main menu (C).
Continue pressing the RIGHT navigation button to view all items in the Main menu. -
If you want to navigate back to the Main screen, press the UP navigation button to select the Back button (D). Once the back button is selected, press the SELECT navigation button and the Main screen (A) will appear.
Navigate the Settings menu
-
Start from the Main screen (A), and press the RIGHT navigation button to enter the Main menu.
-
Spa is the first item in the Main menu (C).
Continue pressing the RIGHT navigation button until the Settings menu is selected (E). -
Press the SELECT navigation button to enter the Settings menu (F).
-
The Navigation arrow (H) indicates more settings. Press the DOWN navigation button to scroll down the list.
Press-and-Hold
If you need to navigate a long list, press-and-hold the navigation button. For
example, press-and-hold the DOWN navigation button to scroll down the Settings
menu list (G). The Navigation arrow (H) indicates more menu items.
View Message Screen
- Start from the Main screen (A), and press the LEFT navigation button to select the Message icon (B).
- Pressing the SELECT navigation button to view the Message screen.
- The Message screen may have an Exit button or a Clear button. Select the button on the screen and press the SELECT navigation button. View “Exit and Clear Buttons” on page 31 for more information.
SET TIME-OF-DAY
Be sure to set the Time-of-Day
Setting the Time-of-Day can be important for determining water filtration
times and other background features.
Follow these steps to set the time-of-day:
- Navigate to Time (A).*
- Press the SELECT navigation button, and the Time screen will appear (B).
- Use the navigation buttons to adjust your settings (D).
- Select the Save button (C), and press the SELECT navigation button.
You have set the time-of-day.
If you do not want to save your settings, select the Cancel button (H), and
press the SELECT navigation button.
If Time-of-Day has not been set, this Information icon appears (G). Select the
Information icon and press the SELECT navigation button to view the
corresponding message in the Information screen (F). Select the Exit button
(E) and press the SELECT navigation button to exit the Information screen.
You can choose a 12-hour or 24-hour time display (View “UNITS” on page 29). If
you choose 24-hour time, “am” and “pm” are removed. CE control systems default
to a 24-hour time display.
CHANGE THE SET TEMPERATURE
Follow these steps to change the Set Temperature:
-
Start at the Main screen (A). Press the SELECT navigation button to view the temperature menu (E).
-
Press the RIGHT and/or LEFT navigation buttons to change the Set Temperature.
The center box (D) indicates the current Set Temperature. In this example the current Set Temperature is 102. -
Once your desired Set Temperature is in the center box (D), press the SELECT navigation button, or just wait a few seconds.
The change is complete.
How do I view the Water Temperature?
The Water Temperature is displayed here (B) on the Main screen.
How do I view the Set Temperature?
Start at the Main screen (A), and press the SELECT navigation button. The Set Temperature is displayed in the center box of the temperature menu (D).
How do I know when the water heater is On?
The center of the Heater Status icon turns red (C) when the heater is On, and it turns white when the heater is Off.
What do the dashes indicate (F)?
When the spa is powered On, four dashes appear (F) in the Water Temperature display for one minute.
The dashes indicate that the spa is checking the water temperature. After the pump runs for 1 minute, the dashes disappear and the water temperature is displayed (B). The dashes may reappear after the pump has not run for one hour.
RUN SPA DEVICES
There are two ways to run spa devices.
1 – Run spa devices by pressing any of these buttons (G).
2 – Run spa devices from the Spa screen by following these steps.
1 – Navigate to the Spa menu (A).*
2 – Press the SELECT navigation button to view the Spa screen (B). Each icon
(D) shown in the Spa screen represents a spa device.
3 – Select Jets 1 (E). When you select an icon, its name appears at the top of
the screen (E).
4 – Press the SELECT navigation button to run the spa device.
The spa device is running.
If you want to navigate back to the Main screen, select the Back button (C)
and press the SELECT navigation button. The Main screen will appear.
The functionality of each spa device may vary. For example, some devices may
have a single speed or state, while other spa devices may have multiple speeds
or states. Your spa configuration will determine the number of spa devices and
the functionality of each device.
One Spa screen (B) can display a maximum of six devices. If your spa has more
than six, a menu arrow will appear (F). Press the RIGHT navigation button to
view and/or run the other spa devices.
SET FILTER CYCLE TIMES
Keep your water clean and ready to enjoy!
Follow these steps to set the Filter Cycles:
-
Navigate to Filter (A).*
-
Press the SELECT navigation button to view the Filter screen (B).
-
Select the start time for Filter Cycle 1 (C). Press the SELECT navigation button to view the time controls (E).
-
Enter your time settings (E) with the navigation buttons.
-
Select the Save button (D), and press the SELECT navigation button.
You have set the start time for Filter Cycle 1.
If you do not want to save your settings, select the Cancel button (F), and press the SELECT navigation button. -
Follow the same process to change the other Filter time settings if desired.
-
Once all of the time changes are set, select the Save button (G), and press the SELECT navigation button.
You have set all of the Filter Cycle times.
How can you tell if Filter Cycle 2 is enabled?
Filter Cycle 2 is enabled when a white ring appears around the 2 (H). In this example there is no white ring, so Filter Cycle 2 is disabled. Filter Cycle 2 is disabled by default on many spas.
ADJUSTING FILTRATION
Circulation Pump Modes
Some spas may be manufactured with Circulation
Pump settings that allow programming filtration cycle duration. Some
Circulation Modes are pre-programmeto operate 24 hours a day and are not
programmableRefer to the spa manufacturer’s documentation for anCirculation
Pump Mode details. Purge Cycles
In order to maintain sanitary conditions, as well as protect against freezing,
secondary water devices wpurge water from their respective plumbing by running
briefly at the beginning of each filter cycle. (Some systems will run a
certain number of purge cycles per day, independent of the number of filter
cycles per dIn this case, the purge cycles may not coincide with tstart of the
filter cycle.)
If the Filter Cycle 1 duration is set for 24 hours, enabling Filter Cycle 2
will initiate a purge when Filter Cycle 2 iprogrammed to begin.
The Meaning of Filter Cycles
- The heating pump always runs during the filter cycle*
- In Rest Mode, heating only occurs during the filter cycle
- Purges happen at the start of each filter cycle (on most systems).
- For example, if your spa is set up for 24-hour circulation except for shutting Off when the water temperature is 3˚F/1.5˚C above the set temperature, that shutoff does not occur during filter cycles.
AUXILIARY PANELS
Specific Buttons for Specific Devices
If the spa has any auxiliary panel(s) installed, pressing a button on such
panel(s) will activate the device indicated for that button. These dedicated
buttons will operate just like the Spa Screen buttons (view page 13).
Auxiliary Panels
RESTRICT OPERATIONS
The
control can be restricted to prevent unwanted use or temperature adjustments.
Locking the Panel (D) prevents the controller from being used, but all
automatic functions are still active.
Locking the Settings (C) allows Jets and other features to be used, but the
Set Temperature and other programmed settings cannot be adjusted. Settings
Lock allows access to a reduced selection of menu items. These include Filter
Cycles, Invert, Information and Fault Log. They can be seen, but not changed
or edited.
Follow these steps to lock the Settings:
-
Navigate to Locks (A).*
-
Press the SELECT navigation button to view the Lock screen (B).
-
Navigate to Settings (C). In this example the Settings are unlocked.
-
Press-and-hold the SELECT navigation button for approximately 5 seconds. After 5 seconds, the toggle switch will move to the right and turn blue (G), and a lock icon will appear (E).
You have locked the Settings.
Follow the same steps to lock/unlock the Settings and/or Panel. -
Navigate back to the Main screen. The lock icon on the Main screen (H) indicates that the Settings are locked.
Can Settings and Panel be locked simultaneously?
Yes. The lock icon (H) appears if the Settings or the Panel or both are locked. The current lock states are indicated by the toggle switches in the Lock screen (C, D).
INVERT DISPLAY
Follow these steps to invert the display:
- Navigate to Invert (A).*
- Press the SELECT navigation button to invert the panel display (B). Every screen will be inverted.
You have inverted the display (B).
Follow the same steps to restore the default display orientation (C).
SPA BEHAVIOR
-
FILTRATION AND OZONE
If your spa does not have a circulation pump, pump 1 low and the ozone generator will run during a filter cycle. If your spa has a circulation pump, the ozone will run with the circulation pump.
Many control systems are factory-programmed with one filter cycle that will run in the evening (assuming the time-of-day is properly set) when energy rates are often lower. The filter cycle time and duration are programmable (view page 14). A second filter cycle can be enabled as needed.
At the start of each filter cycle, any additional water devices (such as pumps and blower) will also run briefly to purge its plumbing to maintain good water quality. -
FREEZE PROTECTION
If the temperature sensors within the control system’s heater detect a low enough temperature, then the pump(s) and the blower automatically activate to provide freeze protection. The pump(s) and blower will run either continuously or periodically depending on conditions.
In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch. See your dealer for details. -
CLEANUP CYCLE (Optional)
When a pump or blower is turned on by pressing a button on the panel, a clean- up cycle begins 30 minutes after the pump or blower is turned Off or times out. The pump and the ozone generator will run for 30 minutes or more, depending on the control system. On some control systems, you can change this setting (view page 29). -
PUMPS
Press the JETS button once to turn Pump 1 On or Off, and to shift between low- speed and high-speed if equipped. If left running, Pump 1 will turn Off after a time-out period.
If your spa does not have a circulation pump, Pump 1 will run at low speed when the blower or any other pump is on.
If the spa is in Ready Mode (view page 22), Pump 1 low may also activate for at least 1 minute every once in a while to detect the spa temperature (polling) and then to heat to the set temperature if needed. When the low- speed turns on automatically, it cannot be deactivated from the panel, however the high speed may be started. -
3 CIRCULATION PUMP MODES
If the spa is equipped with a circulation pump, it will be configured to work in one of the following three modes:
MODE 1: The circulation pump will operate continuously (24 hours) with the exception of turning Off for at least 30 minutes at a time when the water temperature reaches 3°F (1.5°C) above the set temperature (most likely to happen in very hot climates).
MODE 2: The circulation pump will stay on continuously, regardless of the water temperature.
MODE 3: A programmable circulation pump will come on when the control system is checking the water temperature (polling), during filter cycles, during freeze conditions, or when another pump is on.
Circulation pump modes are determined by the Manufacturer and cannot be changed in the field. -
HOW DOES YOUR CONTROL SYSTEM CHECK THE WATER TEMPERATURE?
The control system (A) activates a pump that circulates water from the spa tub through the water heater (B) shown below. The water heater contains two temperature sensors (C). When water flows around the sensors, the control system calculates the water temperature. This process is referred to as “polling” in this user guide. -
HEATER PUMP
The heater pump is any pump dedicated to circulating water through the water heater. If your spa has a circulation pump, the circulation pump will serve as the heater pump. If your spa does not have a circulation pump, a two- speed pump will serve as the heater pump. If the heater pump is a two-speed pump, anytime it is activated automatically (for any reason, including to check the water temperature), it will activate at low speed.
HEAT SETTINGS
Keep your spa heated and ready to enjoy, or keep it cool and save energy. Heat
Settings help you do both.
Heat Settings are divided into two groups.
- Heat Modes
- Temperature Ranges
HEAT SETTINGS HEAT MODES
Follow these steps to view the current Heat Mode and/or change the Heat Mode:
-
Navigate to Heat (A).*
-
Press the SELECT navigation button to view the Heat screen (B). The current Heat Mode will appear here (C). In this example the current Heat Mode is Rest.
There are two Heat Modes to choose from: Ready, Rest. -
Press the SELECT navigation button to change the Heat Mode to Ready (D).
You have set the Heat Mode to Ready.
The change takes effect immediately. No need to press a Save button
Ready-In-Rest Mode is a third Heat Mode. But, it is a sub-feature of Rest Mode and is not selectable from the panel menu.
The only place you can see whether you’re in Ready-in-Rest Mode is on the Main screen, where it shows all three Heat Modes in icon form.
If you are in Ready-in-Rest Mode, and you want to cancel it (ie, you want to return to Rest Mode), just go view the current Heat Mode (where it will say Rest Mode) and exit. That simple action takes you back to Rest Mode
Where can I view the current Heat Mode on the Main screen?
The current Heat Mode is displayed here with an icon (E). In this example the
current Heat Mode is Ready.
The following list shows which icons may appear on the Main screen.
Heat Mode Icons
Ready:
Rest:
Ready-in-Rest:
HEAT SETTINGS
TEMPERATURE RANGES
Follow these steps to view the current Temperature Range and/or change the
Temperature Range:
-
Navigate to Heat (A).*
-
Press the SELECT navigation button to view the Heat screen (B). The current Temperature Range will appear here (C). In this example the current
Temperature Range is Low. There are two Temperature Ranges to choose from: High, Low. -
Press the SELECT navigation button to change the Temperature Range from Low to High (D).
You have set the Temperature Range to High.
The change takes effect immediately. No need to press a Save button.
Can I see the current Temperature Range on the Main screen?
Yes. The current Temperature Range is displayed here with an icon (E). In this example the current
Temperature Range is High. The following list shows which icons may appear on the Main screen.
Temperature Range Icons
High:
Low:
HEAT SETTINGS
M8
M8 is artificial intelligence software contained in your spa’s BP control
system. M8 looks for opportunities to decrease device usage by evaluating
water temperature readings. Stable water temperatures equal less device usage
and less wear and tear.
Follow these steps to view the current M8 setting and/or turn it On/Off.
- Navigate to Heat (A).*
- Press the SELECT navigation button to view the Heat screen (B). The current M8 will appear here (C). In this example the current M8 setting is Off.
- Press the SELECT navigation button to change the M8 setting from Off to On (D).
M8 is turned On.
The change takes effect immediately. No need to press a Save button.
Note: M8 is not available on all control systems.
FILL IT UP!
Follow these steps to prime any one-speed pump, including a circulation
pump:
Press the button (JETS 1, JETS 2, etc.) for that pump once to turn it On. Run
the pump for 2 minutes. If priming is not complete after 2 minutes, turn Off
the pump and repeat the process.
Which pump is the heater pump?
When the spa has just entered Priming Mode, press the LIGHT button (B) and see
if any water flows. If so, you have a circulation pump serving as the heater
pump. If not, a two-speed pump serves as the heater pump. A circulation pump
is controlled with the LIGHT (B) button (in Priming Mode only). A two-speed
heater pump is controlled by pressing the JETS 1 (A) button.
Once the heater pump is primed, prime any additional pumps.
The heater pump is the most important pump to prime.
IMPORTANT: A pump should not be allowed to run without priming for more than 2
minutes. Under NO circumstances should a pump be allowed to run without
priming beyond the end of the 4 minute Priming
Mode. Doing so may cause damage to the pump and in some cases may cause the
system to energize the heater and go into an overheat condition.
EXITING PRIMING MODE
Priming Mode ends automatically. However, you can manually exit Priming Mode
during this time by selecting the Back Arrow (D) and pressing the SELECT
navigation button (F).
When Priming Mode ends (automatically or manually) the panel will display
dashes (H). Once the control system cycles water through the heater for one
minute, the dashes will be replaced by the water temperature.
SETTINGS
Fine tune your spa with a wide variety of Settings
Navigate to Settings (A) to view and/or control your spa. *
This is an example of a Settings list (B). Your Settings list may vary.
HEAT
Make sure your spa is heated and ready to enjoy with Heat Settings (view page
20).
TIME
Set the Time to insure scheduled features have proper timing (view page 11).
REMINDERS
Reminders (A) are helpful spa maintenance messages that display periodically.
LOCKS
Lock the Panel and/or Settings (view page 16).
FILTER
Keep your spa water clean and ready to enjoy by setting Filter Cycles (view
page 14).
HOLD
Hold is used to disable the pumps during service functions like cleaning or
replacing the filter. Hold Mode will typically last for 1 hour unless the mode
is exited manually. You can see how much longer Hold will last at the bottom
of the screen (for example, “Holding for 0:58”). If you Exit this screen, Hold
Mode ends.
If spa service will require more than an hour, it may be best to simply shut
down power to the spa.
Drain Mode (Optional)
Some spas have a special feature that allows Pump 1 to be employed when
draining the water. When available, this feature is a component of Hold.
CLEANUP CYCLE (Optional)
When a pump or blower is turned On by a button press, a Cleanup cycle begins
30 minutes after the pump or blower is turned Off or times out. The pump and
the ozone generator will run for 30 minutes or more, depending on the system.
You can change this setting on some control systems.
If Cleanup is set to zero hours, this feature will be disabled.
Cleanup is not included with all control systems, and control of Cleanup is
not included with all control systems that have Cleanup.
UNITS
Specify Time and Temperature Units (C). The temperature choices are Fahrenheit
or Celsius. The time display choices are 12 hour or 24 hour.
LANGUAGE
Select from a variety of languages (D).
PANEL
Set how long it takes the panel to go to sleep after the last activity. The
default is 30 minutes (F).
Turn On/Off the panel lights (G).
Control the brightness of both the panel lights and the panel display together
(H).
DIAGNOSTICS
Spa technicians can find useful information and features in Diagnostics (view
page 38).
PANEL MESSAGES
This chapter lists all of the Panel Messages and explains each one. Some Panel Messages have corresponding Message Codes. If so, the Message Code appears below the Panel Message.
MESSAGE CODES
The easiest way to explain a Message Codes is with a troubleshooting scenario.
For example, what happens if the spa water overheats? The panel will display
“The water is too hot”. Also, the control system will capture the following
information and save it in a fault log:
- Time-Of-Day.
- Water temperature, Set Temperature.
- The number of days that have passed since the water overheated.
- Temperature Range.
- Heat Mode.
- Message Code.
The Message Code links the Panel Message to the corresponding Fault Log information. On this panel, both the Panel Message text and the Message Code are displayed in the fault log.
GENERAL MESSAGES
Several alerts and messages may be displayed in a sequence.
Possible freezing condition
A potential freeze condition has been detected, or the Aux Freeze Switch has
closed. All water devices are activated. In some cases, pumps may turn On and
Off and the heater may operate during Freeze Protection.
This is an operational message, not an error indication.
HEATER-RELATED MESSAGES
The water flow is low
Message Code: M016 *
There may not be enough water flow through the heater to carry the heat away
from the heating element.
Heater start up will begin again after about 1 minute.
See “Flow Related Checks” below.
The water flow has failed
Message Code: M017
There is not enough water flow through the heater to carry the heat away from
the heating element and the heater has been disabled. See “Water Flow
Checklist” on page 37 . After the problem has been resolved, reset the message
.
The heater may be dry
Message Code: M028
Possible dry heater, or not enough water in the heater to start it. The spa is
shut down for 15 minute. Reset this message* to reset the heater start-up. See
“Water Flow Checklist” on page 37.
The heater is dry
Message Code: M027
There is not enough water in the heater to start it. The spa is shut down.
After the problem has been resolved, you must reset the message to restart
heater start up. See “Water Flow Checklist” on page 37.
The heater is too hot
Message Code: M030
One of the water temp sensors has detected 118°F (about 48°C) in the heater
and the spa is shut down. You must reset the message when water is below
108°F (about 42°C). See “Water Flow Checklist” on page 37.
Flow-related checks
Check for low water level, suction flow restrictions, closed valves, trapped
air, too many closed jets and pump prime. On some systems, even when spa is
shut down by an error condition, some equipment may occasionally turn on to
continue monitoring temperature or if freeze protection is needed. See “Water
Flow Checklist” on page 37.
EXIT and CLEAR Buttons
Some messages can be reset from the panel. Messages that can be reset will
appear with a Clear button (B). If the message has an Exit button (A), the
Message icon will remain on the Main screen once you exit the Message screen.
- View page 39 for instructions on how to review the Fault Log that corresponds with the Message Code.
-
- This message can be reset from the panel using the CLEAR button (view “EXIT and CLEAR Buttons” notes above).
PANEL MESSAGES
Sensors are out of sync
Message Code: M015 *
The temperature sensors may be out of sync by 3°F.
Call for Service if this message does not disappear within a few minutes.
Sensors are out of sync
Message Code: M026 ***
The temperature sensors ARE out of sync. The fault above has been established
for at least 1 hour.
Call for Service.
SYSTEM-RELATED MESSAGES
Program memory failure **
Message Code: M022 *
At Power-Up, the system has failed the Program Checksum Test. This indicates a
problem with the firmware (operation program) and requires a service call.
The settings have been reset (Persistent Memory Error) *
Message Code: M021
Contact your dealer or service organization if this message appears on more
than one power-up.
The clock has failed *
Message Code: M020
Contact your dealer or service organization.
Configuration error
The spa will not Start Up. Contact your dealer or service organization.
The GFCI test failed
(System Could Not Test the GFCI)
Message Code: M036
(North America Only) May indicate an unsafe installation. Contact your dealer
or service organization.
A pump may be stuck On
Message Code: M034
Water may be overheated. POWER DOWN THE SPA.
DO NOT ENTER THE WATER. Contact your dealer or service organization.
Hot fault
Message Code: M035 *
A Pump Appears to have been Stuck ON when spa was last powered POWER DOWN THE
SPA. DO NOT ENTER THE WATER. Contact your dealer or service organization.
REMINDER MESSAGES
Reminder messages can be reset from the panel. Press the Clear Icon to reset
the Reminder message.
General maintenance helps
Reminder Messages can be suppressed by using the Reminders Screen. Reminder
Messages can be chosen individually by the Manufacturer. They may be disabled
entirely, or there may be a limited number of reminders on a specific model.
The frequency of each reminder (i.e. 7 days) can be specified by the
Manufacturer.
Check the pH
May appear on a regular schedule, i.e. every 7 days.
Check pH with a test kit and adjust pH with the appropriate chemicals.
Check the sanitizer
May appear on a regular schedule, i.e. every 7 days.
Check sanitizer level and other water chemistry with a test kit and adjust
with the appropriate chemicals.
Check ozone
May appear on a regular schedule.
Change the UV as instructed by the manufacturer.
Service check-up
May appear on a regular schedule.
Do a service check-up as instructed by the manufacturer.
Additional messages may appear on specific systems.
Clean the filter
May appear on a regular schedule, i.e. every 30 days.
Clean the filter media as instructed by the manufacturer.
Test the GFCI (or RCD)
May appear on a regular schedule, i.e. every 30 days.
The GFCI or RCD is an important safety device and must be tested on a regular
basis to verify its reliability.
Every user should be trained to safely test the GFCI or RCD associated with
the hot tub installation. A GFCI or RCD will have a TEST and RESET button on
it that allows a user to verify proper function.
Change the water
May appear on a regular schedule, i.e. every 90 days.
Change the water in the spa on regular basis to maintain proper chemical
balance and sanitary conditions.
Clean the cover
May appear on a regular schedule, i.e. every 180 days.
Vinyl covers should be cleaned and conditioned for maximum life.
Treat the wood
May appear on a regular schedule, i.e. every 180 days.
Wood skirting and furniture should be cleaned and conditioned per the
manufacturers instructions for maximum life.
Change the filter
May appear on a regular schedule, i.e. every 365 days.
Message Code: M03 *
Filters should be replaced occasionally to maintain proper spa function and
sanitary conditions.
Change the UV
May appear on a regular schedule.
Change the UV as instructed by the manufacturer.
MISCELLANEOUS MESSAGES
Set the Time-of-Day
When a control system that displays this message is powered On, its time-of-
day is initialized to 12:00 PM. Setting the proper time-of-day is important
for determining filtration times and other background features (view page 11).
MESSAGE NOTES
Some messages include the “Call for Service” text as it requires a service
technician to fix the problem. If the panel is locked and a message alert
appears, you will be taken to the Lock Screen (where you will need to Unlock
the panel) before you can clear the message.
The Selection box defaults to the Clear or Exit icon (A) on the Message
screen. Press the LEFT navigation button to move the Selection box to the
Error/Warning/ Reminder icon (B), and then press the SELECT navigation button
to go to the System Information screen (view page 38).
Communications error
The control panel is not receiving communication from the Control System (view
diagram below). This can appear briefly during system start-ups. This is
normal. If it does not go away quickly, Call for Service.
WATER FLOW CHECK LIST
Make sure the spa is filled with enough water to allow proper water flow
through all of the spa’s plumbing.
Closed valves can inhibit proper water flow.
Jets may be equipped with water valves. If too many water valves are closed,
proper water flow may be inhibited.
Make sure suction covers are unobstructed and free of debris.
One pump cycles water through the heater.
All plumbing connected to this pump and the heater must be free from trapped
air. Trapped air can restrict proper water flow. Remove trapped air by priming
this pump.
DIAGNOSTICS
SYSTEM INFORMATION
Follow these steps to view the System Information:
- Start from the Main Screen and navigate to the Settings menu.*
- Navigate to Diagnostics and select it to view the Diagnostics screen (A).
- Navigate to System Information and select it to view the System information screen (C). This is an example of a System Information list (C). Your System Information list may vary. Press the DOWN navigation button to scroll down the whole list.
FAULT LOG
Useful information about your spa is captured when a fault occurs. The
information is stored in a Fault Log (B). Up to 24 faults can be stored in the
Fault Log. This is an example of information that is captured in one fault ( I
); Your information may vary. This information can help spa technicians
diagnose and fix issues. Not every entry in the Fault Log is an actual
“fault”. For example, message code MO19 is inserted into the fault log to
identify each time the spa restarts.
Each time a fault occurs, it is assigned a unique number, starting with number
- The next fault is assigned number 2, and so on. Up to 24 faults can be
stored in memory. In this example the fault number is 2/24 (C). This means it
is the second fault in a list of 24 faults. The fault with the highest fault
number is the most recent fault.
Each fault is assigned a message code (D). The code corresponds with a panel message (E). In this example the message code is 28. All panel messages and message codes are listed and explained in the chapter titled “Panel Messages” (view page 30).
“Days Ago” indicates the number of days that have passed since the fault occurred (F). Each time power to the spa is cycled Off and On again, a new day is added.
“Temp A” (G) is the temperature reading from sensor A, which located inside of the Control System’s heater shown below.
“Temp B” (H) is the temperature reading from sensor B, which located inside of the Control System’s heater shown below.
GFCI TEST
Your systems may have GFCI configured in one of three ways:
- GFCI test is not enabled
- Manual GFCI test is enabled but automatic GFCI test is not enabled
- Both manual and automatic GFCI tests are enabled.
The automatic test will happen within 7 days of the spa being installed and if successful will not repeat. (If the automatic test fails it will repeat after the spa is restarted.)
The GFCI Test button (A) will appear on the Diagnostics screen only if the GFCI is enabled.
North America Only. Feature not available on CE rated systems.
The GFCI Test screen (view next page) allows the GFCI to be tested manually
from the panel and can be used to reset the automatic test feature.
The Ground Fault Circuit Interrupter (GFCI) or Residual Current Detector(RCD)
is an important safety device and is required equipment on a hot tub
installation. (The GFCI Test Feature is not available on CE rated systems).
Used for verifying a proper installation
Your spa may be equipped with a GFCI Test feature. If your spa has this
feature enabled by the manufacturer, the GFCI Trip Test must occur to allow
proper spa function. On some systems:
Within 1 to 7 days after startup, the spa will trip the GFCI to test it. (The
number of days is factory programmed.) The GFCI must be reset once it has
tripped. After passing the GFCI Trip Test, any subsequent GFCI trips will
indicate a ground fault or other unsafe condition and the power to the spa
must be shut Off until a service person can correct the problem.
On systems that do not have the automatic GFCI test, the manual GFCI test must
be done.
FORCING A MANUAL GFCI TRIP TEST
WARNING
On those systems that automatically test the GFCI within 1 to 7 days after
startup: The end-user must be trained to expect this one timeless to occur.
The end-user must be trained how to properly reset the GFCI. If freezing
conditions exist, the GFCI or RCD should be reset immediately or spa damage
could result. The installer can cause the GFCI Trip Test to occur at any time
by activating Test (A) on the GFCI Test screen. The GFCI should trip within
several seconds
and the spa should shut down. If it does not, shut down the power and manually
verify that a GFCI breaker is installed and that the circuit and spa are wired
correctly.
Verify the function of the GFCI with its own test button. Restore power to the
spa and repeat the GFCI Trip Test. Once the GFCI is tripped by the test, reset
the GFCI and the spa will operate normally from that point. You can verify a
successful test by navigating to the above screen. “Passed” should appear on
the GFCI screen. PERFORM A GFCI TEST
Follow these steps to perform a GFCI test:
- Navigate to GFCI Test (A). *
- Press the SELECT navigation button to view the GFCI Test screen (B).
- Navigate to “Test” (C) and press the SELECT navigation button perform the test.
The GFCI Status is viewed here (D). If the GFCI Test status is “Passed” (F), you may not need to perform this test.
If the GFCI Test status is “Armed” (D), proceed to the next step.4 – Press the SELECT navigation button perform the test. Within approximately 12 seconds, one of the following two things will happen: 1 – The spa powers down. After the spa powers down, go to the GFCI and power up the spa. The spa goes into Priming Mode when it is powered up. When Priming Mode is complete, navigate to the GFCI Test screen and confirm that it says “GFCI Status – Passed” (F).
2 – A “GFCI Test Failed” message appears. In this case, contact a qualified service technician. While you wait for the spa technician to arrive, the spa can be run normally for a time by cycling the power.
Reset Button: Only use the Reset Button (E) prior to moving the spa to a new
location. Pressing the Reset the button forces a new Test to be performed at
the new location.
WARNING! Qualified Technician Required for Service and Installation.
Basic Installation and Configuration Guidelines
- Use minimum 6AWG copper conductors only.
- Torque field connections between 21 and 23 in lbs.
- ‘Readily accessible disconnecting means to be provided at time of installation.
- Permanently connected.
- Connect only to a circuit protected by a Class A Ground Fault Circuit Interrupter (GFCI) or Residual Current Device (RCD) mounted at least 5’ (1.52M) from the inside walls of the spa/hot tub and in line of sight from the equipment compartment.
- CSA enclosure: Type 2
- Refer to Wiring Diagram inside the cover of the control enclosure.
- Refer to Installation and Safety Instructions provided by the spa manufacturer.
Warning: People with infectious diseases should not use a spa or hot tub.
Warning: To avoid injury, exercise care when entering or exiting the spa
or hot tub.
Warning: Do not use a spa or hot tub immediately following strenuous
exercise.
Warning: Prolonged immersion in a spa or hot tub may be injurious to your
health.
Warning: Maintain water chemistry in accordance with the Manufacturers
instructions.
Warning: The equipment and controls shall be located not less than 1.5
meters horizontally from the spa or hot tub.
Warning! GFCI or RCD Protection.
The Owner should test and reset the GFCI or RCD on a regular basis to verify
its function.
Warning! Shock Hazard!
No User Serviceable Parts.
Do not attempt service of this control system. Contact your dealer or service
organization for assistance. Follow all owner’s manual power connection
instructions. Installation must be performed by licensed electrician and all
grounding connections must be properly installed.
CSA Compliance
Caution:
- Test the ground fault circuit interrupter or residual current device before each use of the spa.
- Read the instruction manual.
- Adequate drainage must be provided if the equipment is to be installed in a pit.
- For use only within an enclosure rated CSA Enclosure 3.
- Connect only to a circuit protected by a Class A ground fault circuit interrupter or residual current device.
- To ensure continued protection against shock hazard, use only identical replacement parts when servicing.
- Install a suitably rated suction guard to match the maximum flow rate marked.
Warning:
- Water temperature in excess of 38°C may be injurious to your health.
- Disconnect the electrical power before servicing.
Attention:
- Disconnect the electric power before servicing. Keep access door closed.
INFORMATION
TP700 SUPPORT
Trademark | Patent Notices
BALBOA WATER GROUP and the stylized logo are registered trademarks or
applications applied for in the US Patent & Trademark Office. All rights
reserved. All other product or service names are the property of their
respective owners.
Products are covered under one of more of the following US Patents: 5332944,
5361215, 5550753, 5559720, 5,883,459, 6282370, 6590188, 7030343, 7, 417, 834
B2 & Canadian Pt 2342614 plus others. Other patents both foreign and domestic
applied for and pending.
TP700 SUPPORT
Trademark | Patent Notices
BALBOA WATER GROUP and the stylized logo are registered trademarks or
applications applied for in the S Patent & Trademark Office. All rights
reserved. All other product or service names are the property of their
respective owners.
Products are covered under one of more of the following US Patents: 5332944,
5361215, 5550753, 5559720, 5,883,459, 6282370, 6590188, 7030343, 7, 417, 834
B2 & Canadian Pt 2342614 plus others. Other patents both foreign and domestic
applied for and pending.
42370_rev A TP700 User Guide
©2021 Balboa Water Group. Single Source Solution. All rights reserved.
3030 Airway Avenue | Costa Mesa, CA 92626 | p 714.384.0384 |
www.balboawatergroup.com Specifications
subject to change without notice.
TP700 PANEL
Email info@balboawater.com
Phone
P : + 714.384.0384
Customer Service is available: M – F 7:00AM to 6:00PM PT
MEXICO OPERATIONS
Balboa Water Group
Aguila Azteca 6011 Baja Maq. El Aquila
Mexico 22221
Corporate Office
Balboa Water Group
3030 Airway Avenue Costa Mesa, CA 92626
EUROPEAN OPERATIONS
Balboa Water Group
Hydroid International ApS Rousted 50
6800 Varde – Denmark
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>