GIMYUAN W7 10.1 Inch LCD Digital Microscope
Product Information
Specifications
- Model: W7/W10
- Compliance: Part 15 of the FCC Rules
- Power Supply: 5V-2A adapter
- Interface: HDMI, USB, SD
Product Overview
Thank you for purchasing the digital microscope device. Before using it,
please read this user manual carefully. This device complies with Part 15 of
the FCC Rules.
Operation is subject to the following two conditions:
- This equipment will not cause harmful interference.
- This equipment must accept any interference received, including interference that may cause unintended operation.
FCC Radiation Exposure Statement: This equipment complies with the FCC radiation exposure limits established for uncontrolled environments.
Important Notes
- Please fully charge the product before first use. Please do not charge directly through the PC, but choose a 5V-2A adapter.
- This product is not a biological microscope and is not suitable for cell biology research.
- This product cannot accurately read microscope magnification. It is a combination of digital and optical magnification microscope, and the specific magnification effect is subject to the actual picture taken.
- When the battery is low, both the storage mode and camera mode cannot be used normally. This is not a product failure.
- Please protect the lens carefully and make sure to cover the lens with the cap after use to prevent dust or foreign objects from entering.
- Please pay attention to the placement of specimens or other objects to be observed and try to place them in the center of the lens directly below. This will avoid unclear observations and ensure a good user experience.
- Do not disassemble the product or component structure by yourself to avoid abnormal equipment use.
Accessories and Tools
- Hex key x1
- Screws x4
- Remote control x1
- Data cable x1
- HDMI cable x1
- Column x1
- Base x1
- Screen x1
- Fill light x2
How to Assemble
Microscope Components
- Connect the both by the connectors as illustrated
- Align the column with the groove and insert it.
- Insert four screws into the base to fix the column.
- Insert the fill light into the USB port.
- The Type-C on the top of the column is connected to the host as illustrated .
- Insert the latch at the back of the host into the dovetail slot on the column.
- Insert the memory card and remove the lens cap.
- Adjust the height of the host to a suitable level by using the height adjustment knob
Function Introduction
Interface Usage Instructions
- Base power supply interface
- Charging indicator (The red light is on under charging. The green light is on when fully charged.)
- Charging Camera Memory
- HDMI port
Button Functions
-
Power button
Press and hold for 3 seconds to switch on/off the device -
Reset button
Reset to the original factory defaults. -
Left button
Move up/Zoom in/Page up -
Right button
Move down/Zoom out/ Page down -
Photo button
Take a photo -
Video button
Start recording/End recording -
Menu button
Open the menu/Exit the menu -
OK button
Confirm selection/Play/Pause -
Status indicator light
Steady on after power on Goes off after power off -
Infrared sensor
Receiving infrared remote control signals -
Fill light adjustment knob
Left for bright
Right for dim -
Focus ring
Magnification adjustment Microscope optical focus adjustment -
Lens light adjustment knob
Left for dim
Right for bringt -
Height adjustment knob
Adjust the host to the appropriate height. -
TF card slot
Support expansion 0-64G TF card
Supports connection to HDMI display
HDMI output for larger view
Connect the microscope to the screen via an HDMI cable, then turn on the
device, and you can watch it simultaneously on the large screen.
Remote Control
- Contains a Battery, Battery Model: CR2050
- Before use, please remove the transparent film from the side of the remote control.
Overall Parameters of Microscope
Lens | Lens pixels | 48 MP |
---|---|---|
Magnification | 1600 X | |
Focusing mode | Manual | |
Focusing Distance | 0-40 mm | |
Video resolution | 720/1080/1440P | |
Photo resolution | 2-48M | |
Video format | MP4/AVI | |
Photo format | JPG |
Screen
| Screen size| 7 ” IPS
10.1 ” IPS
---|---|---
Screen resolution| 1024*600P
Other| Model No.| W7
W10
Input voltage & current| 5V/2A
Battery capacity| 4000mAh lithium battery
Working time| 2.5hrs
Charging time| 2.5hrs
TF capacity| Support expansion 0-64GB Only support high-speed storage card of
class 10 or above, not including class 10
Other| Material| Aluminum Alloy+ABS+PC
---|---|---
Operating temperature| -10℃ ~45℃
Camera temperature| -10℃ ~45℃
Light source| 8 high brightness LEDs 2 LED fill light
Operating systems| Windows 7and above
MacOS 11.0 and above
Languages| Simplified Chinese/Traditional chinese/English/Français/ Deutsch
Español/Italiano/Português/ Japa-nese
System Interface Guide
Settings Interface Functions
- Setting: After powering on, the device defaults to the observation mode. Click , button and then click the button to select settings , click button to enter the settings page, as shown.
- Date/Time: Click” ” “ ‘button to select Date/Time and then click button to enter the settings page. Click button once to switch between year/month/day, and click “ ” “ ‘button to adjust the digits, as shown .
Photo Resolution
Adjust the size of the output image resolution, the higher the resolution, the
clearer the image, but the more memory it occupies. The image resolution is
divided into:2M、3M、5M、8M、 10M、12M、16M、20M、 24M、36M、 48M。
Exposure Compensation
Exposure compensation is a method of exposure control, with a range of about
±3-3EV. If the ambient light is dim, you can increase the exposure value (such
as adjusting to +1EV, +2EV) to highlight the clarity of the image.
Video Resolution
Change the output video resolution, the higher the resolution, the clearer
the image, but the more memory it occupies. The video resolution is divided
into720P/1080P/1440P。
Date Tags
Turn on/off the display of date label.
Auto shutdown
Set the automatic shutdown time for the device, you can choose to
automatically shut down or turn off the function after 5-60minutes.
Language Settings
Switch device language(Simplified Chinese/Traditional
chinese/English/-Français/ Deutsch Español/Italiano/Portu-guês/ Japanese)
Line Support
Turn on/off the line assistance function.
Formatting
Initialize the TF card.
Screen brightness
Adjust the device screen brightness (10%-100%) according to the observation
needs.
Date/Time
Set the date and time
Light source frequency
Select 60-50Hz in the frequency of the light source.
Default Settings
Restore system default settings.
Versions
Device system version.
- If the device has sufficient battery power, you can use it directly. The following are the operating instructions without charging.
- If you want to use the device while charging, please refer to the settings on page 26.
- Take a photo / Record a video: After powering on, the device defaults to the observation mode. Click“ ” button for taking a photo or click button for recording and click , button once for ending the record.
- Photo Preview: Click button to enter menu mode, click button to select click button to enter the photo browsing page, as shown .
- Video Playback: Click button to enter menu mode, click button to select click button to enter the video browsing page, as shown.
- When browsing page, click button 1-2 times to locate at the top left corner of the screen , as shown .
- Page switching: Click “ ” “ ‘ button to select “Previous Page/Next Page” and click button to flip the page.
- Delete file: click “ ” “ ‘ button to select Select , click button to select, click button to locate to Select as shown in pictures (4), and then click button to select Delete , click button to delete .
- When viewing photos in full-screen mode click” ” “ ‘ botton for page turning .
- When video playback, click button to rewind, click button to fast forward, click button to pause/start. As shown :
Usage Instructions on Computer
Please refer to the “Usage Instructions on computer” section in the user
manual for detailed instructions on how to use the microscope with a computer.
Different systems require different software. Please choose and download the
corresponding software based on your system.
Download for Windows system (Supports Windows 7/8/9/10/11 or higher versions):
-
When using Windows 7 and above, download the application “UniLab ” Download link :http://www.weetool.net
Select UniLab for Windows or amcap v3.0.9 for loading ,as shown: -
When using Windows 10 and higher versions, search for the software in the Microsoft Store“UniLab” or use the pre-installed software on your computer called“ Camera
Software “unilab”page, as shown: Software “Camera”page, as shown: Note: To switch the camera, click button located at the top right corner of the screen. If the image still cannot be captured, please adjust the privacy settings of your camera.
For Apple systems (Supports macOS X 11.0 or higher versions): -
Using the pre-installed software on your Apple computer called “Photo Booth”
Software “Photo Booth”page, as shown:
-
Connect the Type-C cable that comes with the original packaging to USB port of the computer.
-
After powering on, click button to select Camera as shown in pictures(1), click , button as shown in pictures (2), You can watch by opening the software on your computer. (Please refer to pages 22-25 for the software startup page.)
Note: At this time, the microscope screen does not display images, and the button functions cannot be used. This is a normal phenomenon. (The brightness adjustment button, focus ring, and power button can be used normally.) -
After powering on, click button to select Memory as shown in pictures(1), click, button as shown in pictures (3), You can read, write, and format on the computer side.
-
After powering on, click button to select Memory as shown in pictures(1), click , button as shown in pictures (4), At this time, the microscope directly displays the observed object.
Microscope Troubleshooting
Please refer to the “Microscope Troubleshooting” section in the user manual for troubleshooting tips and solutions.
Problem description | Causes | Solutions |
---|---|---|
Device cannot be charged. |
- The charging port is not securely plugged in.
- No power source is connected.
- Device malfunction.
|
- Re-plug the interface firmly.
- Connect the power supply.
Device cannot connect to computer software side.| Loose connection, damaged
data cable, or not using a connection cable with data transfer function-
ality.| Re-plug the interface, replace the data cable, or use a data cable
with data transmission function to reconnect and use.
The image blurriness caused by the lens.|
- The object is not directly below the camera lens.
- The focal length is not adjusted to the optimal position.
- The lighting is not being used correctly.
- The lens is fogged up
|
- Check the placement of the object.
- Refocus.
- Adjust the lighting properly.
- 4Wait for the temperature to stabilize. Use it again after the fog has dissipated for a while.
Product cannot be turned off or buttons are unresponsive.| Crash| Please perform a reset and restart.
Operating Environment
Please refer to the “Operating Environment” section in the user manual for
information on the recommended operating environment for the microscope.
Storage Environment
- Store in a cool, dry place away from direct sunlight for daily use
- Avoid storing the microscope in places where there is a risk of falling. Falling may cause deviation of the internal lenses or damage to other components, as well as other irreparable damage issues.
- You can charge the microscope using a regular phone charger, computer, or power bank.
- Please do not exceed 12 hours of charging time to avoid affecting the battery’s lifespan.
- During the charging process, it is normal for the microscope shell and battery to have slight heating, please use it with confidence.
- Please use it in an environment between -10℃ and 45℃.
- Please avoid themicroscope being splashed with water, drinks, or corrosive liquids.
- Please avoid placing the microscope near heat sources, open flames, and flammable or explosive gases or liquids.
- Please avoid impacting and violently shaking the microscope.
FAQ
-
Q: Is this microscope suitable for cell biology research?
A: No, this product is not a biological microscope and is not suitable for cell biology research. -
Q: Can I charge the product directly through my PC?
A: No, please do not charge directly through the PC. It is recommended to use a 5V-2A adapter. -
Q: How can I protect the lens from dust or foreign objects?
A: After use, make sure to cover the lens with the cap provided to prevent dust or foreign objects from entering. -
Q: Can I disassemble the product by myself?
A: No, please do not disassemble the product or component structure by yourself to avoid abnormal equipment use.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>