uvex 2000-3000 Clear Safety Glasses with Anti Fog Lens Instructions

June 15, 2024
uvex

2000-3000 Clear Safety Glasses with Anti Fog
Lens Instructions

2000-3000 Clear Safety Glasses with Anti Fog Lens

User instruction for vex silk-Air classic (2000/3000),
p+e (7000/8000), premium (5000),
premium plus (5000+)

Instructions for use

  1. Follow the instructions for use 2/3) Storage conditions – see packaging 4/5) Date of manufacture and expiry date – see packaging
    Transportation Recommended use of original packaging.
    Use The particle-filtering half mask is a complete respiratory protection device made fully or predominantly from filter material (does not contain any allergens). Can be used at protection levels FFP1 (blue), FFP2 (orange) and FFP3  (black) to protect against solid and liquid aerosols up to a level many times higher than the specified limit (L). FFP1 = 4xL (not against particles from carcinogenic and radioactive materials, microorganisms or enzymes), FFP2 = 10xL (not  against particles from radioactive materials, viruses and enzymes), FFP3 = 30xL (20xL for the UK). *) Limits include, for example, the MAC and TRC limits for air in the workplace specified in TRGS 900. (MAC = maximum admissible workplace concentration; TRC = technical reference concentration)
    Warnings/restrictions Read and follow the national requirements and instructions for use. The mask does not protect against gases and vapours. Users must be familiar with using and handling the product. Facial hair or scars around the edge of the mask will prevent the mask from fitting properly. Particle filtering half masks must not be worn in inadequately ventilated chambers, pits, trenches and confined spaces. The surrounding area must have a minimum oxygen content of 17 vol% (in compliance with national requirements). Closed-circuit self-contained breathing apparatus (SCBA) must be used in environments with a risk of oxygen deficiency, a concentration of hazardous substances which is too high, or where conditions are unknown. In the event of increased airway resistance, after use or after damage to the mask, it should be disposed of in accordance with local regulations. The product must not be altered. Not suitable for use in explosive atmospheres.
    Check before use The mask must be suitable for the intended application. An individual risk assessment must be carried out in each individual case. If you are uncertain about anything or have any questions regarding application, please contact your safety officer.
    Check the mask is within the expiry date and shows no signs of visible defects; do not use the mask if a defect is present or the expiry date has been exceeded.
    Instructions for fitting the mask Follow the pictograms on the packaging in the correct order. Carefully stretch out the headband slightly using both hands (not necessary for fabric headbands). Hold the preformed or unfolded mask in your hands that the headbands are hanging down. Place the mask below your chin with the nose clip pointing up. Position the lower Banda round your neck and the upper band above your ears. Adjust the nose clip. Secure the headband and/or adjust if necessary. Check the mask’s seal: place both hands at the sides of the mask and exhale forcefully. If air escapes from the sides of them ask, readjust the nose clip and/or headband. Do not enter the workstation unless the seal is complete. It is essential for your protection that the mask fits correctly; an improper fit can resin serious illnesses.
    Storage Store in the original packaging. For storage conditions/ shelf life see packaging. Store the mask away from chemical substances, moisture, direct sunlight and dirt.
    Labelling NR = non-reusable (dispose of after one shift); R= reusable (but for no more than 3 shifts), refer to “Cleaning”
    section;D = has passed the clogging test. Cleaning/disinfection For masks labelled R, clean and disinfect the inside of the mask with vex clear cleaning spray immediately after use (spray for a duration of 5 seconds from a distance of approx. 30 cm). Check the mask is fit for purpose before the next use. Authorisation The product meets the Harmonised / designated standard EN149:2001+A1:2009 meets the requirements of PPE Regulation (EU) 2016/425 and Regulation 2016/425 on PPE as brought into UK Law and amended. The applicable jurisdiction can be found in the Declaration of Conformity; this can be found at: www.uvex-safety.co.uk/en/media/uk-declarations-of-conformity/

UVEX ARBEITSSCHUTZ GMBH
Wuerzburger Str. 181-189
90766 Fourth GERMANY
T: +49 911 9736-0
F: +49 911 9736-1760
E: [email protected]
I: uvex-safety.com
certified by:
BSI Group The Netherlands B.V., Say Building,
John M. Keynesplein 9,
1066 EP, Amsterdam,
NETHERLANDS
Notified body number: 2797 Humidity
Storage temperature
UKCA certified by:
BSI Assurance UK Ltd
Approved Body 0086
Kitemark Court, Davy Avenue,
Know hill, Milton Keynes, MK5 8PP,
UNITED KINGDOM
The certification is a type
examination (Module B) and
an ongoing quality surveillance (Module D).
UVEX SAFETY (UK) LIMITED
uvex House
Furnham Trading Estate
Furnham Surrey
GU9 9NW
UNITED KINGDOM

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

uvex User Manuals

Related Manuals