Tera Z2-US Home Electric Vehicle Wall Charger User Manual
- June 15, 2024
- Tera
Table of Contents
- Model: Z2-US
- User Manual
- EV Charger
- Symbol Meaning
- Product Overview
- Dimensions
- Product Parameter
- Installation
- Here are the usage steps:
- Follow these steps to wire the power for Level 1 charging
- Follow these steps to wire the power for Level 2 charging
- Warning And Cautions
- Fault Indicator Prompt
- WHAT’S IN THE BOX
- Troubleshooting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Model: Z2-US
Home Electric Vehicle Charger
User Manual
Ver.E01.1.01
EV Charger
Current: 32A 40A 48A
Temperature Protection
|
Auto Repair
|
Efficient Charging
|
Protection Level IP55
RCD
|
High End MCU
|
Under Voltage Protection
|
Over Voltage Protection
Short Circuit Protection
|
Earth Leakage Protection
|
Lightning Protection
|
Over Load Protection
Symbol Meaning
Symbol
|
Meaning
---|---
| “Non-recyclable” Label:
Found on the product, instruction manual, this label indicates that electrical
and equipment, along with their accessories, disposed of separately from
regular household or packaging, electronic must be waste. When discarded,
treat these items as industrial waste to prevent potential accidents.
| Warning Sign:
This symbol highlights potential hazards. Exercise caution result from to
avoid personal improper procedures or injury incorrect that may operation.
Actions associated with the “warning” sign be undertaken when the specified
conditions understood and met. should only are fully understood the met.
The company is dedicated to the ongoing improvement and updating of its products. Both hardware and software may be subject to upgrades, and the information provided is subject to change without prior notice.
Product Overview
Appearance of AC EV Charger
- Indicator light
- Charging plug
This product is an AC charging station primarily designed for electric vehicle
charging. The charging station consists of the main body a wall-mounting
backplate, and other components.
The product adheres to industrial design principles, making it easy to install
and use.
Exterior: Sleek and lightweight, with a variety of color options to suit different application scenarios.
Protection: Boasting an IP55 protection level (waterproof and dustproof), the charging station can withstand exposure to wind, rain, and sun.
Operation: The charger head features a one-button cover opening design, ensuring simple and convenient plug-and-play operation.
Safety: Enhanced safety measures include multiple protections, high-quality fireproof, waterproof, and dustproof materials.
Compatibility: With its compact size and powerful performance, the charging station is compatible with 99% of new energy vehicles.
Quality:
The charging station uses pure, oxidation-resistant copper wiring that meets
inspection standards and provides flame retardant impact resistance.
Dimensions
Size 10.4 6.7 3.1 inch
Measurement Unit: inch
Product Parameter
Charging Device | Rated Current | 32A | 40A | 48A |
---|---|---|---|---|
User Interface | Indicator light | |||
Cable routing | Bottom inlet wiring, Bottom outlet wiring | |||
Dimension | 10.4 6.7 3.1 inch | |||
Input voltage | Level 1: 100-120V; Level 2: 200-240V | |||
Input frequency | 50/60Hz | |||
Output voltage | Level 1: 100-120V; Level 2: 200-240V | |||
Charging Wire length | 15/20/25/30FT | |||
Protection Design | Over-current protection value | ≥110% | ||
Over-voltage protection value | 270Vac for Level 2; 140Vac for Level 1 | |||
Under-voltage protection value | 190Vac for Level 2; 90Vac for Level 1 | |||
Over-temperature protection value | 176°F | |||
Electric leakage protection value | 30mA AC+6mA DC | |||
Environmental indicators | Work temperature | -86°F~122°F | ||
Work humidity | -5%~95% non-condensation | |||
Work altitude | <2000m | |||
Protection Level | IP55 | |||
Cooling Model | Natural cooling | |||
MTBF | 50,000 hours |
Installation
1
Fix the screws and mounting plate to the wall.
2
Place the charging station onto the mounting plate attached to the wall.
3
Assemble the anti-theft screw on the side.
Here are the usage steps:
1. Ensure that the charging box is connected to a power source.
|
2. Connect the electric vehicle to the charging box using the EV charging cable.
---|---
3. The vehicle will charge normally.
|
4. Unplug the device and wrap the cable around the hook.
Note:
- Once the vehicle is fully charged, the device will automatically stop charging.
- Please read the instructions thoroughly before using the device.
Follow these steps to wire the power for Level 1 charging
If a power distribution box is being used, make sure to connect the L (Line), N (Neutral), and PE (Protective Earth) ends of the input cable of the plug to the corresponding L, N and PE ends of the circuit breaker respectively.
Follow these steps to wire the power for Level 2 charging
If a power distribution box is being used, make sure to connect the L1, L2 (Line 1 and Line 2), and PE (Protective Earth) ends of the input cable of the plug to the corresponding L1, L2, and PE ends of the circuit breaker respectively.
Warning And Cautions
For use only in an environment with an RCD residual current protector.
Do not use the device if the charging cable is damaged.
For electric vehicle charging purposes only.
The product must be properly grounded when in use.
It is strictly prohibited to step on, pull bend, or knot the charging cable.
Do not insert your finger into the charging plug.
Do not attempt to connect the circuit yourself without the guidance of a
professional.
Do not use when the inside of the charging plug is wet.
Do not attempt self-installation without first reading the installation
instructions.
Do not use for any purposes other than electric car charging.
SPECIAL ATTENTION: Under no circumstances should you attempt to disassemble
the device yourself. This may cause damage to the internal precision parts.
Fault Indicator Prompt
Working state
| Red| Green| Blue
---|---|---|---
Power On (No Load)| /| Stays On|
/
Insert the Plug(Uncharged)
| /| Flashing| /
Charging Mode| /| /|
Flashing
Charging Completed
| /| /| Stays On
Leakage Protection| Flash for 1| /|
/
Over Current Protection
| Flash for 2| /| /
Ground Fault(ungrounded)| Flash for 3| /|
/
Under/Over Voltage Alarm
| Flash for 4| /| /
Relay Failure| Flash for 5| /|
/
CP/CC Error
| Flash for 6| /|
/
Remark:
The device flashes a certain number of times at 200ms intervals to indicate an
error, and then repeats this sequence in a continuous loop with 1s intervals.
WHAT’S IN THE BOX
|
---|---
Charging Station x 1
Charging Plug x 1| Mounting Template x 1
M3.5*35mm
|
M3*10mm
|
---|---|---
Wall Plug x 4
Long Screw x 4| Short Screw x 2| User Manual x 1
Troubleshooting
Problem | Causes | Possible Solutions |
---|---|---|
Excessive Leakage Current | Excessive Leakage Current | 1. Please disconnect |
the leakage or over-current protection switch on the distribution box
immediately.
2. Please check whether the AC charger output line is damaged or has low
impedance to the ground or a short circuit.
3. Please inspect the inlet socket of the vehicle to ensure it is in good
condition.
4. Once the above issues have been addressed, please attempt to power on the
system again. If the problem persists, please do not hesitate to contact us
for further assistance.
AC Over-current| High Input Current| 1. Please immediately disconnect the
leakage/over current protection switch from the distribution box.
2. Please check if there is a low impedance or a short circuit between the
two output lines of the AC charger.
3. After troubleshooting the issues mentioned above, please attempt to power
the system on again. If the problem persists, please contact us for further
assistance.
Ground Fault| Ground fault circuit interruption| 1. Please immediately
disconnect the leakage/over current protection switch from the distribution
box.
2. Please check whether the input/output line of the AV charger is properly
grounded or not.
3. After troubleshooting the issues mentioned above, please attempt to power
on the system again. If the problem persists, please contact us for further
assistance.
AC Under-voltage| Low Input Voltage| 1. If the voltage drops below 190Vac for
level 2 or 90Vac for level 1 for a brief period of time, the charger will go
into standby mode and check the power network to restore itself to the normal
voltage range. Once the voltage is within normal range, the charger will
automatically resume charging.
2. If the voltage in your area/community remains consistently low (below
190Vac for level 2 or 90Vac for level 1) for an extended period of time please
wait to use the charger until the voltage recovers back to the normal range.
AC Over- voltage| High Input Voltage| 1. If the voltage surpasses 270Vac for
level 2 or 140Vac for level 1 for a short duration, the charger will enter
standby mode and conduct a power network check to restore itself to the normal
voltage range. Once the voltage is within normal range, the charger will
automatically resume charging.
2. If the voltage in the local area or community remains over 270Vac for
level 2 or 140Vac for level 1 for a prolonged period, the user should refrain
from using the charger until the voltage returns to the normal range.
Relay Failure| Relay Failure or Adhesion| 1. Try restarting the charger and
allow it to run its internal self-diagnostic and repair routines.
2. If the problem persists even after restarting the charger, please do not
hesitate to contact us for further assistance.
CP/CC Error| Charger CP/CC Connection Error| 1. Please check whether the
charging plug is securely and firmly connected to the vehicle’s inlet socket.
2. If the problem persists, please do not hesitate to contact us for further
assistance.