Uthfy BGA2302-60K Propane Forced Air Heater Instruction Manual
- June 14, 2024
- Uthfy
Table of Contents
- BGA2302-60K Propane Forced Air Heater
- SAFETY
- UNPACKING
- PRODUCT IDENTIFICATION
- THEORY OF OPERATION
- PROPANE SUPPLY
- INSTALLATION
- VENTILATION
- OPERATION
- MAINTENANCE
- STORAGE
- SERVICE PROCEDURES
- TROUBLESHOOTING
- SPECIFICATIONS
- HEATER DIAGRAM
- PARTS LIST
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PROPANE FORCED AIR HEATER
BGA2302-60K / BGA2302-85K
BGA2302-60K Propane Forced Air Heater
ANSI 783.7-2017
CSA 2.14-2017
READ INSTRUCTIONS CAREFULLY:
Read and follow all instructions. Place instructions in a safe place for
future reference. Do not allow anyone who has not read these instructions to
assemble, light, adjust or operate the heater.
If service is required for this Heater, please E-mail us at
Aftermarket311@gmail.com
WARNING: if the information in this manual is not followed exactly, a
fire or explosion may cause property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
— Service must be performed by a qualified service agency.
This is an unvented portable heater. It uses air (oxygen) from the area in
which it is used. Adequate combustion and ventilation air must be provided.
Refer to page 3.
Forced Air means that a blower or fan pushes the air through the heater.
Proper combustion depends upon this air flow; therefore, the heater must not
be revised, modified or operated with parts removed or missing. Likewise,
safety systems must not be circumvented or modified in order to operate the
heater.
IMPORTANT: Read and understand this manual before assembling, starting or
servicing heater. Improper use of heater can cause serious injury. Keep this
manual for future reference
GENERAL HAZARD WARNING:
Failure to comply with the precautions and instructions provided with this
heater can result in death, serious bodily injury and property loss or damage
from hazards of fre, explosion, burn, asphyxiation. carbon monoxide poisoning
and/or electrical shock.
Only persons who can understand and follow the instructions should use this
heater
WARNING!
Manufacturer and seller expressly disclaim any and all liability from
personal injury, property damage or loss, whether direct or indirect, or
incidental, resulting from the incorrect attachment, improper use, inadequate
maintenance, or neglect of this product.
SAFETY
WARNING: Fire, burn, inhalation and explosion hazard. Keep solid
combustibles, such as building materials, paper or cardboard, a safe distance
away from the heater as recommended by the instructions. Never use the heater
in spaces which do or may contain volatile or airborne combustibles or
products such as gasoline, solvents, paint thinner, dust particles or unknown
chemicals.
WARNING: Not for home or recreational vehicle use.
The heateris designed for use as a construction heater in accordance with ANSI
Z83.7CGA2.14. (Check with your local fire safety authority if you have
questions about heater use.) Other standards govern the use of fuel gases and
heating products for specific uses. Your local authority can advise you about
these. The primary purpose of construction heaters is to provide temporary
heating of buildings under construction, alteration or repair. Properly used,
the heater provides safe, economical heating. Products of combustion are
vented into the area being heated.
We cannot foresee every use which may be made of this heater. Check with your
local fire safety authority if you have questions about heater use.
Propane Gas: Propane gas is odorless. An odor- making agent is added to
propane gas. The odor helps you detect a propane gas leak. However, the odor
added to propane gas can fade. Propane gas may be present even though no odor
exists.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning
resemble the flu with headache, dizziness and/or nausea. If you have these
signs, the heater may not be working properly. Get fresh air at once! Check
for proper ventilation and have the heater serviced.
IMPORTANT SAFETY INFORMATION
- Install and use the heater with care. Follow all local ordinances and codes. In the absence of local ordinances and codes, refer to the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and the Propane Gas Installation Code, CAN/CGA B149.2. This instructs on the safe storage and handling of propane gases.
- Useonlythe electrical voltage and frequency specified on the model plate. The electrical connections and grounding of the heater shall follow the National Electric Code, ANSI/NFPA 70 or Canadian Electrical Code, Part 1
- Electrical grounding instructions – This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazards and should be plugged directly into a properly grounded three- prong receptacle or extension cord.
- Use only a three-prong, grounded extension cord.
- Use only the hose and factory preset regulator provided with the heater.
- Use only propane gas set up for vapor withdrawal.
- Provide adequate ventilation. Before using the heater, provide at least a three square foot opening of fresh, outside air for each 100,000 BTU (105,500 KJ/Hr) of rating.
- For indoor use only. Do not use heater outdoors.
- Do not use the heater in a basement or below ground level. Propane gas is heavier than air. If a leak occurs, propane gas will sink to the lowest possible level.
- Keep the appliance area clear and free from combustible materials, gasoline, paint thinner and other flammable vapors and liquids.
- Do not use the heater in areas with high dust content. Dust is combustible.
- Minimum heater clearances from combustibles: Outlet: 8 ft. (2.4 m), Sides: 2 ft. (0.61 m), Top: 6 ft. (1.83 m), Rear: 2 ft. (0.61 m).
- The heater must be located at least 7 ft. (2.13 m) in the USAor 10 ft. (3 m) in Canada from any propane gas container. And the heater shall not be directed toward propane gas containers.
- Not intended for use on finished floors.
- Never block the air inlet (rear) or the air outlet (front) on the heater.
- Keep heater away from strong drafts, water spray, rain or dripping water.
- Do not leave the heater unattended.
- Keep children and animals away from the heater.
- Check the hose before each use of the heater. If highly worn or cut, replace with a hose specified by manufacturer before using heater.
- Locate the heater on stable and level surface if heater is hot or operating.
- To preventinjury, wear gloves when handling heater.
- Never attach duct work to the heater.
- Do not alter the heater. Keep the heater in its original state.
- Never move, handle or service a hot, operating or plugged-in heater. Severe burns may result. You must wait 15 minutes after turning the heater off.
UNPACKING
- Remove all items from the carton.
- Remove all packing items applied to the heater for shipment. Keep plastic cover caps (attached to inlet connector and hose/regulator assembly) for storage.
- Check all items for shipping damage. If the heater is damaged, contact customer service.
PRODUCT IDENTIFICATION
Any modification to the product or failure to follow recom ded care will void the product warrantuy.
THEORY OF OPERATION
The Fuel System: The hose/regulator assembly attaches to the propane gas
supply. The propane gas moves through the automatic control valve and out the
nozzle.
The Ignition System: The spark transformer and spark plug light the main
burner.
The Safety Control System: This system causes the heater to shut down if the
flame goes out.
NOTE: Some parts are located differently on some heater models.
PROPANE SUPPLY
Propane gas and propane tank(s) are to be furnished by the user.
Use this heater only with a propane vapor withdrawal supply system. The
installer must conform with local codes or, in absence of local codes, with
the Standard for the Storage and Handling of Liquefied Petroleum Gases,
ANSI/NFPA 58 and Propane Gas Installation Code, CAN/CGA B149.1.
The amount of propane gas ready for use from propane tanks varies. Two factors
decide this amount:
- The amount of propane gas in the tank(s)
- The temperature of the tank(s)
The chart below shows the number of 100 Ib (45 kg) tanks needed to run this heater.
Average Temp At Tank Location | No. of Tanks 100 Ib (45 kg) Models |
---|
Above 20°F (-7°C)
20°F (-7°C) to 0°F (-18°C)
Below 0°F (-18°C)| 60| 85
1
1
2| 1
2
2
Smaller tanks can be used for limited run times but it is recommended to use larger tanks for optimum performance.
INSTALLATION
WARNING: To operate the heater safely, review and understand the warnings
in the Safety section, page 3. Follow all local codes when using this heater.
WARNING: Test all gas piping and connections for leaks after installation
or servicing. Never use an open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming show a leak. Correct all
leaks at once.
- Provide an appropriate propane supply system (see Propane Supply).
- Connect fuel gas connector fitting on the hose/ regulator assembly to the propane tank(s). Turn counterclockwise into threads on tank valve. Tighten firmly using a wrench. IMPORTANT: Tighten regulator with vent pointing down. Pointing vent down protects regulator from weather damage (see Figure 3).
- Connect the hose to inlet connector (see Figure 4). Tighten firmly using a wrench. IMPORTANT: Use extra hose or piping if needed. Install extra hose or piping between hose/regulator assembly and propane tank. The regulator supplied with heater must be used.
- The convex hull of the handle is facing the back net cover, and then the four holes of the handle are aligned with the screw holes, and the screws are tightened clockwise with tools.
VENTILATION
WARNING: Follow the minimum fresh, outside air ventilation requirements.
If proper fresh, outside air ventilation is not provided, carbon monoxide
poisoning can occur. Provide proper fresh, outside air ventilation before
running heater.
Provide a fresh air opening of at least three square feet for each 100,000
Btu/Hr (105,500 KJ/Hr) rating. Provide additional fresh air if more heaters
are being used.
OPERATION
WARNING: To operate the heater safely, review and understand the warnings
in the Safety section, page 3. Follow all local codes when using this heater.
TO START HEATER
-
Read and carefully follow all installation, ventilation and safety information.
-
Place heater on a stable and level surface. Make sure the front or rear of heater are not exposed to strong drafts.
-
Plug the power cord of heater into a three-prong, grounded extension cord. Extension cord must be at least 6 ft. (1.83 m) long, UL/CSA listed and of a proper size.
Extension Cord Wire Size Requirements
Up to 50 ft (15m) long, use 18 AWG rated cord.51 to 100 ft (16 to 30 m) long, use 16 AWG rated cord. 101 to 200 ft (30.78 t060.96 m) long, use 14 AWGrated cord. -
Plug extension cord into a 115 volt/60 hertz, 3-prong, grounded outlet. The motor will start. The fan will turn, forcing air out the front of the heater.
-
Open propane supply valve on propane tank(s) slowly. NOTE: If not opened slowly, the excess- flow check valve on propane tank will stop gas flow. You may hear a click from the excess-flow check valve closing. If this happens, reset the excess-flow check valve by closing the propane supply valve and opening it again slowly.
WARNING: Be sure the motor and fan are running before pushing in automatic control valve button. Flames could flash outside the heater if the motor and fan are not running. -
Press and hold in fuel valve button. Heater should ignite within a few seconds. NOTE: If the heater fails to ignite, the hose may have airin it. If so, keep the fuel valve button pressed and wait 20 seconds. Release fuel valve button and wait 20 seconds for
unburned fuel to exit heater.
Repeat this step if necessary. -
After heater ignites, wait 30 seconds; this activates the automatic control system. Release the control knob.
-
Loosen the pinchaing screw counterclockwise, adjust the height plate downward, and tighten the pinchaing screw clockwise after reaching the desired height position.
TO STOP HEATER
- Tightly close the propane supply valve on the propane tank(s).
- Wait a few seconds. The heater will burn gas remaining in the supply hose.
- Unplug the heater power supply cord.
WARNING: If the heater is unplugged or a power outage occurs while the heater is running, the thermal limit device will stop fuel flow. A few seconds occur before the thermal limit device activates. During this short time, flames may appear outside the heater. This is normal.
MAINTENANCE
WARNINGS
- Never service heater while it is plugged in, connected to propane supply, operating or hot. Severe burns and electrical shock can occur.
- Keep heater clear and free from combustible materials, gasoline and other flammable vapors and liquids.
- Do not block the flow of combustion or ventilation air.
- Keep the heater clean. Clean heater annually or as needed to remove dust and debris. If the heater is dirty or dusty, clean heater with a damp cloth, use household cleaners on difficult spots.
- Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak. Correct all leaks at once.
- Inspect the hose/regulator assembly before each use. If the hose is highly worn or cut, replace with hose specified by manufacturer.
- Have the heater inspected yearly by a qualified service agency.
STORAGE
CAUTION: Dpisconnect the heater from propane supply tank(s).
- Store propane tank(s) in safe manner. When the heater is stored indoors, the connection between the propane supply cylinder and the heater must be disconnected.
- Store propane cylinder(s) in accordance with local laws and regulations. In the absence of local codes, follow the Standard for the Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and Propane Storage and Handling Code, CSAB149.2.
- Place plastic cover caps over brass fittings on inlet connector and hose/regulator assembly.
- Storein a cool, dry location. Do not store in locations that are exposed to water or high moisture.
- Covering the heater while in storage will help prevent dust and debris build-up. Ensure the heater is fully cool before covering.
Any modification to the product or failure to follow recommended care will
void the product warranty.
WARNING!
Manufacturer and seller expressly disclaim any and all liability from personal
injury, property damage or loss, whether direct or indirect, or incidental,
resulting from the incorrect attachment, improper use, inadequate maintenance,
or neglect of this product.
SERVICE PROCEDURES
WARNING: Never service heater while it is plugged in, connected to
propane supply, operating or hot. Severe burns and electrical shock can occur.
ELECTRICAL SYSTEM
The entire electrical system for this heater is contained within the motor. If
any part of the electrical system is damaged, you must replace the motor.
MOTOR
-
With the heater on its side, remove access panel.
-
Access the ground screw through the underside of the heater base. Remove ground screw. Disconnect the green motor wire and the green power cord wire from the underside of the shell (see Figure 5).
-
Remove two black wires from motor to terminal board.
-
Carefully push the motor wires through the hole in the bottom of the shell.
-
Use a nut-driver to remove the three screws holding the motor mount to the shell (see Figure 5).
-
Carefully pull motor and fan out of shell
IMPORTANT: Be careful not to damage fan. Do not set motor and fan down with the weight resting on fan. This could damage fan pitch. -
Use a hex wrench to loosen the set screw, which holds the fan to motor shaft (see Figure 6). Remove fan, taking care not to damage the fan blade pitch.
-
Use a nut-driver to remove the two nuts that attach the motor to the motor mount.
-
Discard the old motor.
-
Attach the new motor to the motor mount with two nuts. Tighten nuts firmly.
-
Place the fan onto the new motor shaft, making sure the set screw contacts the flat surface on the motor shaft. Tighten set screw firmly (40-50 inch- pounds [46.08-57.60 kilogram- centimeters]).
-
Carefully route the motor wires through the hole in the shell. Place the motor, motor mount and fan guard into rear of heater shell (see Figure 5).
-
Insert three screws through the heater shell and into the fan guard (see Figure 5). Firmly tighten the screws.
SERVICE PROCEDURES
FAN
- Remove the motor, the motor mount and fan (see Motor, steps 1 through 8, page 8).
- Clean the fan using a soft cloth moistened with kerosene or solvent.
- Dry the fan thoroughly.
- Replace the fan onto the motor shaft. Make sure the set screw contacts the flat surface on the motor shaft (see Figure 6, page 8). Tighten set screw firmly (40-50 inch-pounds [46.08-57.60 kilogram-centimeters]).
- Place the motor and the fan guard into the rear of the heater shell. Make sure the power cord is properly located (see Figure 7).
- Insert three screws through the heater shell and into fan guard (see Figure 7). Tighten screws firmly.
IGNITER
-
Remove the motor and fan the guard from heater (see Motor, page 8, steps 1 through 6).
-
Remove the red igniter wire from Piezo igniter.
Access the igniter wire through the underside of the heater base (see Figure 8). Push the wire up through the notch in the filler panel. -
Use a nut-driver or standard screwdriver to remove the igniter mounting screw from the rear head (see Figure 8).
-
Install the new igniter by attaching it to the rear head with the igniter mounting screw.
-
Run the igniter wire from new igniter through notch in the filler panel. Attach the igniter wire to the Piezo igniter.
-
Set gap between igniter electrode and target plate to 0.17″ (4.318mm) (see Figure 9).
-
Place the motor and fan guard into the rear of the heater shell (see Motor, page 8, steps 11, 12, 13).
CAUTION: Damage caused while servicing the heater is not covered by the limited warranty.
TROUBLESHOOTING
WARNING: Never service heater while it is plugged in, connected to propane supply, operating or hot. Severe burns and electrical shock can occur.
OBSERVED FAULT | POSSIBLE CAUSE | SOLUTION |
---|---|---|
Fan does not turn when the heater is plugged in | No electrical power to heater | |
Fan blades bent | Check voltage to electrical outlet. If voltage is good, check |
heater power cord for breaks
Replace fan. See Fan. page 9
Heater will not ignite| User did not follow installation or operation
instructions properly No spark at igniter. To test for spark, follow step 7
under [gniter, page 9. If you see spark at igniter, have heater serviced by
qualified service person. If no spark seen:
A) Loose or disconnected igniter wire
B) Wrong spark gap| Repeat installation and operation instructions. See
[nstallation and
Operation, pages 5 and 6
A) Check igniter wire. Tighten or reattach loose igniter wire. See
Figure 9, page 9 for igniter wire location
B) Set gap between igniter electrode and target plate to 0.17″ (0.43 cm)
Heater shuts down while running| Propane supply may be inadequate
High surrounding air temperature causing thermal limit device to shut down
heater
Restricted air flow| A) Refill tank
B) Provide additional and/or larger tanks. See Propane Supply, page 5 This can
happen when running heater in temperatures above 85°F
(29.44° C). Run heater in cooler temperatures
Check heater inlet and outlet, remove any obstructions
WARNING:
Do not use the heater in areas with high dust content. Dust is combustible.
WARNING!
Manufacturer and seller expressly disclaim any and all liability from personal
injury, property damage or loss, whether direct or indirect, or incidental,
resulting from the incorrect attachment, improper use, inadequate maintenance,
or neglect of this product.
SPECIFICATIONS
ALL MODELS
-
Electrical Input:
115V, 60 Hz, 1@, 2a Direct Spark Ignition -
Primary Flame Control:
Thermocouple operated gas valve -
Minimum Ambient Temp. Rating: 0°F (-17.8° C)
-
Operating Voltage Range:93.5~125V
60,000 BTU/HR MODEL
-
40000-60000BTU/hr (11.7-17.5kW)
-
Fuel Consumption:
1.8-2.7 pounds/hr (0.84-1.26 kg/hr)
Fuel OrificePort No.: 18 -
Fuel Orifice Port Size: 0.0401″ (1.02mm)
-
Average Air Temp. Rise: 200° F (111° C)
-
Fuel: Propane/LP Gas
-
Gas Supply Pressure to Regulator:
Max – Bottle Pressure, Min – 10 psig (68.9 kPa) -
Gas Supply Pressure Regulator Out: 10psig (68.9 kPa)
85,000 BTU/HR MODEL
-
50,000-85,000 BTU/hr (14.6-25.0 kW)
-
Fuel Consumption:
2.3 – 3.9 pounds/hr (1.05 – 1.78 kg/hr)
Fuel OrificePort No.: 18 -
Fuel Orifice Port Size: 0.0476″ (1.21mm)
-
Average Air Temp. Rise: 200° F (111° C)
-
Fuel: Propane/LP Gas
-
Gas Supply Pressure to Regulator:
Max – Bottle Pressure, Min – 10 psig (68.9 kPa) -
Gas Supply Pressure Regulator Out: 10psig (68.9 kPa)
WIRING DIAGRAM
- If any original wiring as supplied with the heater must be replace.it must be replaced with type AWG 105°C wire or its equivalent except as indicated (‘Type SF2-200.”SGI-250 C)
HEATER DIAGRAM
CAUTION:
Heater may vary from illustration.
The diagram shows a breakdown of the entire unit. Some parts may not be
serviceable or replaced. Use only original replacement parts. This heater must
use design-specific parts. Do not substitute or use generic parts. Improper
replacement parts could cause serious or fatal injuries. This will also
protect your warranty coverage for parts replaced under warranty.
PARTS LIST
CAUTION:
This list contains all parts shown on the heater diagram on page 12. The
diagram shows a breakdown of the entire unit. Some parts may not be
serviceable or replaced. Heater may vary from illustration.
Use only original replacement parts. This heater must use design-specific
parts. Do not substitute or use generic parts. Improper replacement parts
could cause serious or fatal injuries. This will also protect your warranty
coverage for parts replaced under warranty.
No. | Description | Qty. |
---|---|---|
1 | Outer Casing | 1 |
2 | Handle | 1 |
3 | Inner Shell | 1 |
4 | Insulation Shell Support | 4 |
5 | Thermocouple | 1 |
6 | Ignition Needle | 1 |
7 | Burner Disc | 1 |
8 | Before Burning Baffle | 1 |
9 | Burner Outside Network | 1 |
10 | Burner Inner Network | 2 |
11 | Air Inlet Pipe Assembly | 1 |
12 | Safety Thermostat Bracket | 1 |
13 | Reset Thermostat | 1 |
14 | Fan | 1 |
15 | Motor | 1 |
16 | Air Inlet Grill | 1 |
17 | Fixing Plate | 1 |
18 | PCB Isolation Column | 3 |
19 | Power PCB | 1 |
20 | Fixing Plate For Gas Inlet Connector Nut | 2 |
21 | Control Valve Assembly | 1 |
21-1 | Gas Inlet Connector | 1 |
21-2 | Gas Escape Valve | 1 |
21-3 | Ball Valve | 1 |
21-4 | Gas Pipe | 1 |
21-5 | Gas Nozzle | 1 |
22 | Knob | 1 |
23 | Cord Power Supply | 1 |
24 | Nozzle Stents | 1 |
25 | Cable Fastener | 1 |
26 | Back Plate | 1 |
27 | Left Plate | 1 |
28 | Right Plate | 1 |
29 | Lower Plate | 1 |
30 | Height Controller | 1 |
31 | Front Plate | 1 |
32 | Pinching Screw | 1 |
33 | Bottom Stop Plate | 1 |
34 | HoseiRegulator Assembly | 1 |
Any modifi ation to the product or failure to follow recommended cal will void
the product warranty.
CUSTOMER SUPPORT:
Thank you for ordering our product.Should you have any questions,please feel
free to contact us by Email:
Aftermarket311@gmail.com
We always find ways to improve!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>