TESLONG MS450S Pole Inspection Camera User Manual

June 14, 2024
TESLONG

TESLONG MS450S Pole Inspection Camera

Product Manual

  • MS450-NTC is a high-performance industrial endoscope with a 4.5-inch high definition color screen.
  • It is ergonomically designed so that users can control the main buttons with just 1 hand.
  • The snapshot and recording functions are supported; photos and videos can be saved on a TF memory card ( Micro-SD card).
  • This product is equipped with LED-assisted illumination and a small-diameter HD camera.
  • The camera uses a high-sensitivity chip to help this product perform in the dark.
  • The camera probe is interchangeable, it can connect to different probes with different sizes, dimensions, angles, or focal lengths.
  • Warning: This product is an industrial endoscope camera and is not intended for medical use or human examination.

Safety and Maintenance

  • DO NOT violently hit the camera probe, DO NOT imprudently pull the cable.
  • When used in an environment with sharp objects, be extra careful to prevent the probe’s waterproof protective layer from being scratched during usage.
  • The camera probe materials are not resistant to high temperatures. When checking the vehicle engine, please ensure that the temperature inside the engine is at the normal temperature.
  • This product is not suitable for people with limited physical, sensory or mental capabilities.
  • DO NOT allow children to touch or operate this device.
  • In case the device is damaged, DO NOT disassemble it by yourself. Please contact the seller or the agent where you bought it to get a repair service.

Battery Description

  • Please use a 5V household charger that meets safety regulations to charge this device.
  • If you have not used the device for a long time, please ensure that it is charged at least once every 3 months to prevent irreparable damage caused by excessive battery discharge.

Functions

TESLONG-MS450S-Pole-Inspection-Camera-FIG-1

  1. Camera probe connector.
  2. Snap: Take photos/start or end video recording.
  3. Light control: To adjust the LEDs brightness of the camera.
  4. Up and down selection button / Zoom in / Rotate 180°.
  5. Mode: Take Photos, video recording & playback.
  6. Enter: Confirm selection/freeze screen.
  7. Settings: Enter or exit the settings menu.
  8. Power: Press and hold for a few seconds to turn ON/OFF.TESLONG-MS450S-Pole-Inspection-Camera-FIG-2
  9. TF card slot
  10. Charging port
  11. Camera probe lock(Press this button to unlock and pull out the camera probe)
  12. Speaker
  13. Installation hole of Screen brake
  14. Reset
  15. Microphone

Take Photos

  • Press  and press to switch to the take photos to take a photo.

Video Recording

  • Press to switch to video recording mode, and press to start recording.

Instructions

  • Press & hold the Power button for a few seconds to turn the ON/OFF device.
  • Notice: Press this button to switch the front and side lenses. When connecting a dual-lens camera probe.
  • Press this button then pull out the Type-C plug of the probe from the monitor.
  • Note: Connect the camera probe then turn on the device. Restart the device if replacing the camera probe.
  • The device is equipped with a TF memory card(inserted]. Gently press to eject the card.

How to insert TF card

  • Power off the device first before inserting TF card.
  • Make sure the direction and the front and back sides are correct when inserting the TF card.
  • Do not use excessive pressure when inserting or removing the TF card to prevent damage to the card slot structure.
  • You can only take photos or record videos when a TF card is inserted into the device.

Language Settings

  • The default language is English, and the system supports English, Chinese, and German. French, Spanish, Italian, Russian, and Japanese. Setting path:
  • Press the button twice to enter the settings page.
  • Select the second item (Language).
  • Press up and down to select the language you need.
  • Pressm to save your choice.

Copy photo and video files to computer

TESLONG-MS450S-Pole-Inspection-Camera-FIG-13

  • You can use a TF card reader to copy data directly or use a type-C cable to connect to a computer for copying.

Specification Parameters

Screen

  • Screen: 4.5-inch HD Display
  • Screen resolution(Pixels): 854×480
  • Support probe resolution(Pixels): 1.0 Megapixel HD
  • Image Capturing resolution(Pixels): 1920×1080
  • Video Recording Resolution(Pixels): 1280×720
  • Port: Type-C charging port, TF memory card slot

Camera

TESLONG-MS450S-Pole-Inspection-Camera-FIG-17

Others

  • Operating Temperature: 32° F to 113°F (O”C to 45°C)
  • Power Source: 2500mAh Lithium Battery
  • Working Time: 3-4 hours
  • Charging Time: 3-4 hours

Packaging
Monitor, camera probe. Type-C charging cable, user manual, screen bracket Accessories-pick up hock, magnet, mirror (Note: 3.9mm NO accessories)