F F DRL-60-230 Laser Distance Sensor User Manual

May 15, 2024
F F

F F DRL-60-230 Laser Distance Sensor

F -0DRL-60-230-Laser-Distance-Sensor-product

Specifications

  • Power Supply : 230 V
  • Maximum Load Current : Not specified
  • Detection Range : Adjustable
  • Brightness Level: Adjustable
  • Switch-on Time : Adjustable
  • Sensor Wave Length : Not specified
  • Security Beam Scattering: Not specified
  • Power Consumption: Not specified
  • Standby Power Consumption : Not specified
  • Working Temperature: Not specified

F &F Filipowski L.P.

Laser distance sensor, 230 V

Do not dispose of this device in the trash along with other waste!

  • According to the Law on Waste, electro coming from households free of charge and can give any amount to up to that end point of collection, as well as to store the occasion of the purchase of new equipment (in accordance with the principle of old-for-new, regard-less of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the environment and human health.

Purpose

  • The DRL-60-230 is a laser sensor designed to control lighting, especially in corridors and staircases.
  • As the control element here is a separated relay contact, this sensor can also be used for integration into any home automation system.
  • The principle of operation is to emit a light beam and measu-re the delay of returning light as a result of reflection from an obstacle. On this basis, it is possible to precisely determine the distance to the obstacle,
  • which is then compared with the set detection range.
  • The condition for switching on the light is the presence of an obstacle at a distance smaller than the set detection range and a brightness level below the value set on the sensor.
  • This solution is perfect for switching on lighting circuits for example on open stairs, where it is important that the sensor detects presence only on the stairs and ignores everything that happens outside.

Features

  • Laser distance sensor of the ToF (Time of Flight) type;
  • The detection range can be smoothly adjusted in the range of 0.1 to 2 m;
  • A brightness sensor that prevents the light from being switched on when the brightness level is high;
  • Adjustable time of keeping the light on;
  • Separated relay output for direct control of 230 V circuits, or integration into any home automation system;
  • Possibility of direct control of electrical circuits with a load of up to 8 A (AC-1);
  • Compact size, can be mounted in a ø60 mm box;
  • LED indicating the operating status of the sensor;
  • Thermal protection against exceeding the acceptable temperature inside the housing.

Mounting

  1. The location of the mounting of the sensor should be selected in such a way that no fixed obstacles such as floor, wall, staircase step, etc. can be found in the detection cone of the sensor at the assumed operating distance. The diameter of the detection cone, depending on the set operating distance, can be read from the following figure
    F -0DRL-60-230-Laser-Distance-Sensor-01Failure to observe safety distances may lead to unwanted sensor excitation.

  2. Do not mount the sensor with the front-facing a strong light source, as this may lead to incorrect operation of the distance and light intensity measurement system.

  3. Do not mount sensors opposite each other or mirrors, as this can lead to unwanted sensor excitation.

  4. Prepare a hole for the installation box ø60 mm. The minimum recommended depth of the box is 30 mm.

  5. The sensor consists of 2 elements connected together by magnets: mounting frame A and sensor B.
    F -0DRL-60-230-Laser-Distance-Sensor-2

  6. Attach the mounting frame to the box using screws or claws.

  7. Connect the DRL-60-230. For direct control of the lighting, the connection diagram shown later in this manual can be used. For integration with home automation controllers, follow the documentation of the devices to be integrated.

  8. Use the dials to set the operating parameters of the detector: detection range, level of brightness below which switching will occur and switching time of the light.

  9. Slide the detector into the box and press it onto the mounting frame. The magnets in the detector will prevent the detector from pulling out automatically.

Block diagram

F -0DRL-60-230-Laser-Distance-Sensor-3

Description of control terminals

The sensor is designed for a power supply of 165÷265 V AC.

F -0DRL-60-230-Laser-Distance-Sensor-5

Settings

F -0DRL-60-230-Laser-Distance-Sensor-6

F -0DRL-60-230-Laser-Distance-Sensor-7

Connection diagram

Direct connection of 230 V lighting

F -0DRL-60-230-Laser-Distance-Sensor-8

  • When it is necessary to control a load higher than 8 A, or a load with a high starting current, it is recommended to use external contactors or relays adapted to current surges (e.g. PP-1Z-LED 230 V). In this case, the DRL-60-230 switches an external relay to whose contacts the controlled load is connected.

Signalisation

  • The DRL-60-12 sensor is equipped with an LED on the front of the device, which indicates the operating status of the device:
    F -0DRL-60-230-Laser-Distance-Sensor-9

  • Sensor on standby, no obstacles in the detection area.
    F -0DRL-60-230-Laser-Distance-Sensor-10

  • An obstacle in the detection area has been detected. The light was not switched on because the brightness level was too highF -0DRL-60-230-Laser-Distance-Sensor-11

  • .An obstacle in the detection area has been detected. The light is on.
    F -0DRL-60-230-Laser-Distance-Sensor-12

  • Signaling that the acceptable temperature inside the sensor is exceeded. Sensor operation is blocked until the fault has been removed.

  • Too high temperature can be caused by connecting a too high load to the sensor.

  • The brightness level of the signal LED adjusts to the ambient brightness (high ambient brightness – high LED brightness level). When an overtemperature is indicated, the light flashes at maximum brightness.

Technical data

  • power supply 165÷265 V AC
  • maximum load current 8 A
  • detection range (adjustable) 0.1÷2.0 m
  • brightness level (adjustable) 2÷500 lx
  • switch-on time (adjustable) 0÷10 min.
  • detection
  • sensor ToF laser sensor
  • wave length 940 nm
  • security 1st class
  • beam scattering ±18°
  • power consumption
  • standby 0,5 W
  • on (relay on) 1 W
  • terminal 2.5 mm² screw terminals
  • tightening torque 0.4 Nm
  • working temperature -10÷45°C
  • continued on next page
  • dimensions
  • external 80×80×6,5 mm
  • internal (box) ø60 mm, depth= 30 mm
  • mounting flush-mounted
  • ingress protection IP30
  • The F&F products are covered by a warranty of the 24 months
  • from the date of purchase. Effective only with proof of purchase.
  • Contact your dealer or directly with us.

CE declaration

  • F&F Filipowski L.P. declares that the device is in conformity with the essential requirements of The Low Voltage Directive (LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/UE.
  • The CE Declaration of Conformity, along with the references to the standards in relation to which conformity is declared, can be found at www.fif.com.pl on the product page.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals