MEAN WELL NPP-750 Series 750W High Reliable Ultra Wide Output Range Battery Charger & Power Supply 2-in-1 Owner’s Manual

June 14, 2024
MEAN WELL

MEAN WELL NPP-750 Series 750W High Reliable Ultra Wide Output Range

Battery Charger & Power Supply 2-in-1

Product View

 Features

  • Multi-function single unit battery charger or power supply operation modes selectable
  • Output voltage and current adjustable via potentiometer
  • 3-stage charging curve for charging mode
  • -30~+70°C wide operating temperature
  • Multiple protections: Short circuit / Over load / Over voltage / Over temperature
  • Thermal controlled DC fan for noise reduction
  • Remote ON-OFF control
  • Comply with 62368-1+60335-1/-2-29 dual certification
  • Suitable for lead-acid (Pb) batteries|
  • Carry handle accessory available (Order NO.: Carry handle, sold separately)
  • 3 years warranty

 Applications

  • Radio system backup solution
  • Electric scooter charger
  • Camping car • Buses • Heavy duty truck Specialty vehicles
  • Surveillance system
  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment

GTIN CODE

MW Search: https://www.meanwe com/serviceGTIN.aspx

Description

NPP-750 is a miniaturized dual-purpose charger and power supply. In addition to being used as a three- stage charger for lead-acid batteries, it can also be used as a constant voltage output power supply to drive general load. The operating mode can be quickly switched by plugging or unplugging a connector on the front panel. Other features include: ultra-wide voltage output, adjustable voltage via VR on the panel (10.5~21V, 21~42V, 42~80V), adjustable charging current (50~100%), built-in intelligent fan with variable speed based on temperature to reduce noise and extend fan lifetime, -30~+70° C wide operating temperature, suitability for use in different environments, built-in remote ON/OFF control, compliance to IEC/EN/UL62368-1 and household EN60335-1/-2-29 dual safety, multiple built-in protections, and 3-year warranty. The NPP-750 is truly an intelligent, safe, and reliable universal dual- purpose charger and power supply with outstanding cost performance.

Model Encoding

MEAN -WELL- NPP-750 -Series -750W -High -Reliable -Ultra
-Wide -Output -Range -Battery -Charger & -Power -Supply -2-in-1-
FIG-2

SPECIFICATION for Battery Charger mode (Default)

MODEL NPP-750-12 NPP-750-24 NPP-750-48






OUTPUT

| BOOST CHARGE VOLTAGE(Vboost)(default)| 14.4V| 28.8V| 57.6V
FLOAT CHARGE VOLTAGE(Vfloat)(default)| 13.8V| 27.6V| 55.2V


VOLTAGE ADJUSTABLE RANGE

| 10.5 ~ 21V| 21 ~ 42V| 42 ~ 80V
By built-in potentionmeter
MAX. OUTPUT CURRENT(CC)| 43A| 22.5A| 11.3A
CURRENT ADJUSTABLE RANGE

Note.3

| 21.5 ~ 43A| 11.25 ~ 22.5A| 5.65 ~ 11.3A
By built-in potentionmeter
MAX. POWER| 722.4W| 756W| 759.36W
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.4| 150 ~ 500AH| 80 ~ 260AH| 40 ~ 130AH




INPUT

| VOLTAGE RANGE| Note.5| 90 ~ 264VAC           127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.)| Note.6| 92%| 93%| 93%
AC CURRENT (Typ.)| 8.7A/115VAC           4A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A at 230VAC



PROTECTION

| SHORT CIRCUIT| Note.7| Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover


OVER VOLTAGE

| 21.5 ~ 26V| 43 ~ 52V| 82 ~ 100V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down O/P voltage, recovers automatically after temperature goes down



FUNCTION

| CHARGING STAGE| 3 stage only
CHARGER OK SIGNAL| The TTL signal out, Charger OK = H(4.5 ~ 5.5V) ; Charger failure or protection status =L( -0.5 ~ +0.5V)
BATTERY FULL SIGNAL| The TTL signal out, Battery full = H(4.5 ~ 5.5V ); Charging = L(-0.5 ~ +0.5V)
REMOTE CONTROL| Open : Charger stop charging            Short : Charger normal work
FAN ON/OFF CONTROL| Depends on internal temperature




ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes











SAFETY & EMC

(Note 8)

| SAFETY STANDARDS| CB IEC62368-1,IEC60335-1/2-29, Dekra BS EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH




EMC EMISSION

| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–






EMC IMMUNITY

| Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2, 3V/m
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2, 3Vrms
Magnetic Field| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

95% interruptions 250 periods


OTHERS

| MTBF| 883.5K hrs min.       Telcordia SR-332 (Bellcore) ; 95.7K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION| 23015867mm (LWH)
PACKING| 1.84Kg; 4pcs/ 9Kg / 1.63CUFT







NOTE

| 1.   Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.

2.   All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

3.   Float charge voltage(Vfloat) adjustable via potentiomerter in battery charger mode.

4.   This is MEAN WELL’s suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.

5.   Derating may be needed under low input voltages. Please check the derating curve for more details.

6.   The efficiency is measured at 16.8V charge voltage(12V model), 33.6V charge voltage(24V model), 67.2V charge voltage(48V model).

7.   This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.                                     

8.   The charger is considered a component which will be installed into a final equipment. All the radiation tests require an additional 13 26 30 NIZN magnetic

clasp or magnetic ring to the output line for CLASS B and without NIZN magnetic clasp or magnetic ring for CLASS A. The final equipment must be

re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on http://www.meanwell.com)

9.   The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

SPECIFICATION for Power Sunnly mode /Selectable via nin? & 4 iumper of 14nins connector on nanell.

MODEL NPP-750-12 NPP-750-24 NPP-750-48








OUTPUT

| DC VOLTAGE| 14.4V| 28.8V| 57.6V


VOLTAGE ADJUSTABLE RANGE

| 10.5 ~ 21V| 21 ~ 42V| 42 ~ 80V
By built-in potentionmeter
CURRENT ADJUSTABLE RANGE| 21.5 ~ 43A| 11.25 ~ 22.5A| 5.65 ~ 11.3A
RATED CURRENT| 43A| 22.5A| 11.3A
RATED POWER| 722.4W| 756W| 759.36W
RIPPLE & NOISE(max.)| 180mVp-p| 300mVp-p| 480mVp-p
VOLTAGE TOLERANCE| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±0.5%
SETUP, RISE TIME| 1800ms, 60ms/230VAC at full load
HOLD UP TIME (Typ.)| 16ms/230VAC at 75% load 10ms/230VAC at full load




INPUT

| VOLTAGE RANGE Note.3| 90 ~ 264VAC           127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.)| 92%| 93%| 93%
AC CURRENT (Typ.)| 8.7A/115VAC           4A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A at 230VAC




PROTECTION

| ****

OVERLOAD

| 105 ~ 115% rated output power
Protection type : Constant current limiting, unit will shutdown after 5 sec, re-power on to recover
SHORT CIRCUIT| Protection type : Constant current limiting, unit will shutdown after 5 sec, re-power on to recover


OVER VOLTAGE

| 21.5 ~ 26V| 43 ~ 52V| 82 ~ 100V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down O/P voltage, recovers automatically after temperature goes down


FUNCTION

| REMOTE CONTROL| Open : Power OFF            Short : Power ON
DC OK| The TTL signal out, DC OK = H(4.5 ~ 5.5V) ; Power supply failure or protection = L(-0.5 ~ +0.5V)
FAN SPEED CONTROL| Depends on internal temperature




ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes











SAFETY & EMC

(Note 4)

| SAFETY STANDARDS| CB IEC62368-1,IEC60335-1/2-29, Dekra BS EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH




EMC EMISSION

| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–





EMC IMMUNITY

| Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2, 3V/m
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2, 3Vrms
Magnetic Field| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

95% interruptions 250 periods


OTHERS

| MTBF| 883.5K hrs min.       Telcordia SR-332 (Bellcore) ; 95.7K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION| 23015867mm (LWH)
PACKING| 1.84Kg; 4pcs/ 9Kg / 1.63CUFT







NOTE

| 1.   Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.

2.   All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

3.   Derating may be needed under low input voltages. Please check the derating curve for more details.                                    

4.   The PSU is considered a component which will be installed into a final equipment. All the radiation tests require an additional 13 26 30 NIZN magnetic

clasp or magnetic ring to the output line for CLASS B and without NIZN magnetic clasp or magnetic ring for CLASS A. The final equipment must be

re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on http://www.meanwell.com)

5.   The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block DiagramMEAN -WELL- NPP-750 -Series -750W -High -Reliable -Ultra
-Wide -Output -Range -Battery -Charger & -Power -Supply -2-in-1-
FIG-3

Derating CurveMEAN -WELL- NPP-750 -Series -750W -High -Reliable -Ultra
-Wide -Output -Range -Battery -Charger & -Power -Supply -2-in-1-
FIG-4

Function Manual

.Charging Curve

State NPP-750-12 NPP-750-24 NPP-750-48
Constant Current

43A

|

22.5A

|

11.3A

Vboost| 14.4V| 28.8V| 57.6V
Vfloat| 13.8V| 27.6V| 55.2V

Suitable for lead-acid batteries (flooded, Gel and AGM)

V O x I O must be less than or equal to the rated power. Please refer to derating curve

Charger OK / DC OK Signal

Charger OK / DC OK signal is a TTL level signal. The maximum sourcing current is 10mA.

Charger OK / DC OK signal Charger status
“High” : 4.5 ~ 5.5V Work normally
“Low” : -0.5 ~ 0.5V Failure or protection function activated

MEAN -WELL- NPP-750 -Series -750W -High -Reliable -Ultra -Wide -Output
-Range -Battery -Charger & -Power -Supply -2-in-1- FIG-8

Remote ON-OFF Control

**** The NPP-750 can be turned ON/OFF by using the “Remote Control” function.

Between pin7 remote ON-OFF and pin8 +12Vaux Charger status
Short ( Pin 7 = 10.8 ~ 13.2V) ON (Default)
Open ( Pin 7 = -0.5 ~ 0.5V) OFF

Mechanical Specification

MEAN -WELL- NPP-750 -Series -750W -High -Reliable -Ultra -Wide -Output
-Range -Battery -Charger & -Power -Supply -2-in-1-
FIG-10 Connector Pin No. Assignment : HRS DF11-14DP-2DS or equivalent

Pin No. Assignment Mating Housing Terminal
1,2,11~14 NC

HRS DF11-14DS

or equivalent

|

HRS DF11-**SC

or equivalent

3,4| Battery Charger or

Power Supply mode selectable

5| Battery Full
6| Charger OK (Charger mode) or

DC OK (Power supply mode)

7| Remote ON-OFF
8| +12V-AUX
9,10| GND-AUX

LED Status Table

LED Indicator Status
Green Float stage (stage 3) or full charged
Red Charging (stage 1 or stage 2)
No Light Abnormal

Power supply mode
LED Indicator| Status
Green| Normal working
No Light| Abnormal

Control Pin No. Assignment : HRS DF11-14DP-2DS or equivalent

Pin No. Function Description
1,2,11~14 NC —–

3,4

| Battery charger / Power supply| Open: Battery charger, Color of LED loading indicator: Reference to battery charger. Short: Power supply, Color of LED loading indicator :Green.

5

|

Battery Full

| Battery Full Signal, referenced to GND-AUX(Pin 9 & 10).

The Signal is a TTL level signal. The maximum sourcing current is 10mA and only for output.(Note.2) Low (-0.5 ~ 0.5V) : When the battery is charging.

High (4.5 ~ 5.5V) : When the battery is full.

6

|

Charger OK / DC OK

| Charger OK / DC OK Signal, referenced to GND-AUX(Pin 9 & 10).

The Signal is a TTL level signal. The maximum sourcing current is 10mA and only for output.(Note.2) Low (-0.5 ~ 0.5V) : When the charger fails or the protect function is activating.

High (4.5 ~ 5.5V) : When the charger is working properly.

7

|

Remote ON-OFF

| Remote charger ON/OFF Function.

The charger can turn the output ON/OFF by dry contact between Remote ON-OFF and +12V-AUX.(Note.2) Short (10.8 ~ 13.2V) : Charger ON ; Open(-0.5 ~ 0.5V) : Charger OFF ; The maximum input voltage is 13.2V.

8| +12V-AUX| It is controlled by the Remote ON-OFF control.
9,10| GND-AUX| The signal return is isolated from the output terminal. (+V & -V)

Note1 : Non-isolated signal, referenced to [GND(signal)]. Note2: Isolated signal, referenced to GND-AUX

Accessory List

Battery Charger or Power Supply mode of pin 3 and pin 4 mating pin along with NPP-750 (Standard accessory)

MEAN -WELL- NPP-750 -Series -750W -High -Reliable -Ultra -Wide -Output
-Range -Battery -Charger & -Power -Supply -2-in-1-
FIG-11

Carry handle (Optional accessory, battery charger and pull handle should be ordered seperately)

HANDLEMEAN -WELL- NPP-750 -Series -750W -High -Reliable -Ultra -Wide
-Output -Range -Battery -Charger & -Power -Supply -2-in-1-
FIG-13

FOOT PAD

INSTALLATION

Please refer to : http://www.meanwell.com/manual.html

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals