OSRAM AM313830035 Sympl Switch
Product Information
Specifications
- Product Name: e:cue SYMPL Switch
- Brand: OSRAM
- Product Number: AM313830035
General Device Description
- The e:cue SYMPL Switch is a device that is designed to work with the e:cue SYMPL range. It is a system of interfaces for e:cue SYMPHOLIGHT only. The SYMPL Nodes provide various connection types such as DMX/RDM, DALI, digital inputs and outputs, etc. They operate in online mode, acting as device interfaces for SYMPHOLIGHT. All interactions are initiated and controlled by SYMPHOLIGHT. The connections between servers, Cores, and Nodes are made via Ethernet using e:net.
- To operate the SYMPL Nodes, a minimum SYMPHOLIGHT version of 2.0 is required. Earlier versions do not support the SYMPL Nodes. Please note that the e:cue Lighting Application Suite does not support the SYMPL Nodes. Additionally, it is important to mention that the e:cue SYMPL Switch is not hot-pluggable.
Delivery Content
- SYMPL Switch
- Safety instructions
- Welcome note (English)
Installation
Before installing the e:cue SYMPL Switch, ensure that the installation
conditions are met. This includes checking the environmental requirements,
mounting process, and ensuring proper Ethernet connection and power supply.
Installation Conditions
Make sure that the installation conditions are met before proceeding with
the installation of the e:cue SYMPL Switch.
Mounting Process
Follow these steps to mount the e:cue SYMPL Switch:
- Select a suitable location for mounting the switch.
- Securely attach the switch to the chosen location using appropriate mounting hardware.
Ethernet Connection
To establish an Ethernet connection for the e:cue SYMPL Switch, follow
these steps:
- Connect one end of an Ethernet cable to the Ethernet port on the switch.
- Connect the other end of the Ethernet cable to a compatible network device or network outlet.
Power Supply
The e:cue SYMPL Switch must be supplied with power using a separate
certified SELV Class 2 power supply. Follow these steps to connect the power
supply:
- Connect the power supply to the designated power input on the switch.
- Plug the power supply into a suitable power outlet.
Dismounting
If you need to dismount the e:cue SYMPL Switch, take appropriate measures
to protect the components against damage caused by electrostatic discharge
(ESD protection).
Product Specifications
The specifications for the e:cue SYMPL Switch are as follows:
- Product Number: AM313830035
- Dimensions: [insert dimensions]
- Illustration: [insert illustration]
Certifications
The e:cue SYMPL Switch has the following certifications:
- [insert certifications]
FAQ
-
Q: Where can I find the safety instructions for the e:cue SYMPL Switch?
A: The safety instructions can be found in a separate manual provided with the product. Please make sure to read them carefully before using the device. -
Q: What is the maximum length of each connected cable for the e:cue SYMPL Switch?
A: The maximum length of each connected cable is 30 meters. -
Q: Is the e:cue SYMPL Switch hot-pluggable?
A: No, the e:cue SYMPL Switch is not hot-pluggable. Please make sure to power down the device before connecting or disconnecting cables. -
Q: What version of SYMPHOLIGHT is required to operate the SYMPL Nodes?
A: A minimum SYMPHOLIGHT version of 2.0 or higher is required to operate the SYMPL Nodes. Earlier versions do not support them.
Information for Use
- Read the Setup Manual and the Safety instructions carefully. Subject to modification without prior notice. Typographical and other errors do not justify any claim for damages. All dimensions should be verified using an actual part. Modification of the product is prohibited.
- This manual is designed for electricians, system administrators, and product users.
- All product names mentioned in this manual are trademarks of their respective owners. Except for internal use, relinquishment of the instructions to a third party, duplication in any type or form – also extracts – as well as exploitation and / or communication of the contents is not permitted.
Security instructions
- Please read the safety instructions, provided in a separate manual, carefully. Make sure that the environmental, mounting, and installation prerequisites are met. This manual
- should be kept at a safe place and in reach of the device.
Symbols
- The exclamation mark warns about possible damage of the device itself or connected devices.
- The information symbol gives general hints and informs about handling and procedures for use of the device.
Instructions
- Connect cables and data only when the device is powered down.
- Before dismounting, appropriate measures must be taken to protect the respective components against damage caused by electrostatic discharge (ESD protection).
- The device must be supplied by a separate certified SELV Class 2 power supply.
- The maximum length of each connected cable is 30 m.
- If security instructions are missing, please contact the OSRAM support service to receive a new copy.
General device description
- The SYMPL Switch fits perfectly with the e:cue SMYPL range. e:cue SYMPL Nodes are a system of interfaces for e:cue SYMPHOLIGHT only. They provide various connection types like DMX/RDM, DALI, digital inputs and outputs etc. SYMPL Nodes always operate in online mode, as a device interface for SYMPHOLIGHT. All interactions are initiated and controlled by SYMPHOLIGHT. Connections between servers, Cores and Nodes are always made with e:net via Ethernet.
- The SYMPL Switch is a designed Ethernet switch for up to 5 devices. It features PoE to power the connected devices over Ethernet. With PoE the connected devices do not need an additional power supply.
- The SYMPL Switch is powered by an external power supply. It is easily mounted on standard 35 mm DIN rails, or with a key hole in the housing base on walls or on any stable vertical surface. The SYMPL Switch is a simple, reliable and easy to use switch solution for e:cue lighting control solutions with SYMPHOLIGHT
- To operate SYMPL Nodes a SYMPHOLIGHT version 2.0 or higher is mandatory. Earlier versions do not support the SYMPL Nodes. SYMPL Nodes are not supported by the e:cue Lighting Application Suite.
- e:cue SYMPL Switch is not hot-pluggable.
Delivery content
Delivery content of the e:cue SYMPL Switch – Product number AM313830035
- SYMPL Switch
- Safety instructions
- Welcome note (English)
Connectors and Interfaces
View from top:
- Ethernet ports 1 to 3
- e:net LEDs for ports 1 to 3 (Ethernet, LAN activity)
- Power LED
- e:net LEDs for ports 4 and 5 (Ethernet, LAN activity)
- Power supply (Vcc+, Vcc- left to right): 24 V DC. For PoE 48 V DC only.
- Ethernet ports 4 and 5
User interface: LEDs
The SYMPL Switch has six LEDs on the front panel. The six LEDs show the
basic states of the SYMPL Switch.
LEDs
- Power
- Off: no power.
- On: power supplied.
- Act/PoE
- Off: no link available.
- Green: link established; e:net link/ traffic. Red: PoE supplied.
- Orange: PoE supplied and e:net link/ traffic.
General remarks
Transport
Only transport the device in its original packaging. This protects the device
from damage.
Unpacking
- Only unpack the SYMPL Switch at its installation location. To protect the device against condensation water, unpack it and wait until all moisture remaining in the device has evaporated. Condensation can occur when the device is moved from a cold to a warm location. Keep the packaging for use in case of further transport.
- Inspect all parts for completeness regarding chapter “2.1 Delivery content” on page 08. If there is apparent damage to the device or parts are missing from the delivery scope, please contact the OSRAM support service.
Warranty regulations
Depending on the product, guaranty regulations are of different duration. The
warranty time is usually noted in the quote and in the order confirmation. See
“Services” “OSRAM Guarantee” at www.osram.com for
details. Legal warranty regulations apply in any case.
Maintenance and Repair
This device requires no maintenance.
- Before dismounting, appropriate measures must be taken to protect the respective components against damage caused by electrostatic discharge (ESD protection).
- Do not try to repair the device. Return it to your OSRAM distributor for replacement or repair.
Disposal
The proper disposal of packing materials and of the device is the
responsibility of the respective user and for his account; in all other
matters, the retrieval obligation for packing materials and the device is
subject to the statutory regulations.
Batteries and technical appliances must not be disposed of with domestic waste, but should be handed in at the appropriate collection and disposal points.
Support
In case of technical problems or questions regarding installation and repair
please contact:
OSRAM GmbH
- Customer Service
- Karl-Schurz-Str. 38
- 33100 Paderborn, Germany +49 5251 54648-0 support@ecue.com
Installation
- The installation of the SYMPL Switch consists of mounting the device, connections to e:net and to power supply.
- The sequence of cabling is not defined. Supply the SYMPL Switch with power after all cabling is completed; it starts booting.
- Connect cables and data only when the device is powered down.
- Each cable should not exceed a length of 30 m.
Installation conditions
- Installation position Terminals on top and bottom
- Horizontal spacing No spacing necessary
- Minimum vertical rail grid spacing 115 mm (90 + 25 mm)(excluding conduit)
- Recommended vertical rail grid spacing 160 mm (with 40 mm conduit)
- Installation location Indoor
Mounting process
The SYMPL Switch is designed to mount onto a 35mm DIN rail (EN 60715) in a
vertical position:
- Clip the device to the rail from top.
- Apply gentle pressure to the top front to snap it in place. The SYMPL Switch has been mounted successfully.
- You can also mount the SYMPL Switch on any flat surface.
- Use a 3 to 3.5mm screw for the hanger hole. For mechanical stability, mounting on a rail is recommended.
Ethernet connection
- The pin-assignment of the Ethernet ports correspond to RJ45 standards. You can use every common Ethernet component, like cable, splitters, and switches. Connect the SYMPL Switch at the designated Ethernet interfaces with patch cables (RJ45, CAT5).
- The Ethernet port of the SYMPL Node is not designed for inter-building connections with power and lighting transients. Use only intra-building networks to connect the SYMPL Nodes and Cores.
Power supply
Connect the SYMPL Switch to a certified NEC Class 2 24 V DC power supply unit.
To use PoE on any connected device, connect a NEC Class 2 48 V DC power supply
unit. Present power supply equates to the status “On” or running of the SYMPL
Node.
To connect the device to a power supply unit, use the provided 2-pole terminal
and lay the wires as stated on the front label. The voltage assignment is left
V+ and right V-.
Turn the power on when all cables are connected to the SYMPL Switch.
- When using PoE, the SYMPL Switch is not suited for powering over a DC power supply network. Use the provided, dedicated power supply unit in the control cabinet for supplying 48 V DC to the SYMPL Switch.
- The PoE ports are not galvanically isolated from ethernet data.
Dismounting
- Disconnect all attached cables. Dismount the e:cue SYMPL Switch from the rail by pulling the black DIN rail handle and unhitching the SYMPL Node. The dismounting is completed.
- Before dismounting, appropriate measures must be taken to protect the respective components against damage caused by electrostatic discharge (ESD protection).
Product specifications
-
Product number AM313830035
-
Dimensions (W x H x D) 53.5 x 90.5 x 62 mm/ 2.1 x 3.6 x 2.4 in (excl. fastening clip)
-
Weight 80 g
-
Power supply input 24 V DC (terminal plug)
wire gauge: 0.21 … 3.31 sqmm; or for PoE: 48 V DC only -
Power consumption 2 W (no PoE powered devices connected)
-
Operating temperature 0 … 50 °C / 32 … 122 °F
-
Storage temperature -10 … 70 °C / 14 … 158 °F
-
Operating / storage humidity 0 … 80% RH, non-condensing
-
Protection class IP20
-
Installation Indoor installation only, intra building communication only
-
Housing Self extinguishing blend PC/ABS UL E140692
-
Mounting on 35 mm DIN rail (EN 60715), 3 units; or with key hole on any stable vertical surface
-
Interfaces 5 x e:net 10/100 Mbit/s, RJ45
-
PoE-Ports PoE Mode B (PoE over spare wires) according to IEEE802.3af not galvanically isolated from Ethernet data Pmax = 13 W per PoE port
-
LEDs LEDs for Power and Ethernet activity /PoE
Certifications
- Conforms to UL Std. 62368-1
- Certified to CSA Std. C22.2 NO. 62368-1
Dimensions
All dimensions in mm
Illustration PoE
PoE capable devices:
- SYMPL dmx Node
- SYMPL e:pix Node
- SYMPL input Node
- SYMPL serial Node
- SYMPL relay Node
- SYMPL e:bus Node
- SYMPL pro Node
- Butler S2
Downloads and more information at:www.ecue.com and www.traxontechnologies.com
OSRAM GmbH
- Sales Operations
- Karl-Schurz-Str. 38
- 33100 Paderborn, Germany +49 5251 54648-0 support@ecue.com
- www.ecue.com
- Head office : Marcel-Breuer-Strasse 6 80807 Munich, Germany Phone +49 89 6213-0 Fax +49 89 6213-2020 www.osram.com
AM313830035
- e:cue SYMPL Switch Setup Manual (original issue)
- e:cue SYMPL Switch Installationsanleitung (Originalversion)
Edition
- 02.08.22 [EN_DE_SYMPL_Switch_Setup_v1p11]
Published by OSRAM GmbH
- Karl-Schurz-Strasse 38
- 33100 Paderborn, Germany
- ©2021 OSRAM GmbH, BU Digital
- All rights reserved / Alle Rechte vorbehalten
References
- e:cue Lighting Controls - Traxon e:cue Europe
- International Homepage of OSRAM | Light is OSRAM
- Deutsche Homepage | Licht ist OSRAM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>