Oase 6600 Eco Control Digital Pump Controller Instruction Manual

June 14, 2024
Oase

Eco Control
operating instruction

6600 Eco Control Digital Pump Controller

Oase 6600 Eco Control Digital Pump ControllerOase 6600 Eco Control Digital Pump Controller -
bagrauntOase 6600 Eco Control Digital
Pump Controller - tools

WARNING

  • This unit can be used by children aged 8  and above and by per- sons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved.
  • Do not allow children to play with the unit.
  • Only allow children to carry out cleaning and user maintenance under supervision.
  • Possible death or severe injury from electrocution! Before reaching into the water, always disconnect all units in the water that have a voltage of >12 V AC or >30 V DC from the power supply.

Safety information

Electrical connection

  • Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
  • A person is regarded as a qualified electrician if, due to his/her vocational education, knowledge and experience, he or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regulations.
  • For your own safety, please consult a qualified electrician.
  • The device may only be connected if the electrical data of the device and the power supply coincide. The device data is to be found on the device type plate, on the packaging or in this manual.

Safe operation

  • Never operate the unit if an electrical cable is defective!
  •  Never operate the unit if the housing is defective!
  • Never carry or pull the unit by the electrical cable.
  • Route cables such that they are protected from damage and do not present a tripping hazard.
  • Only open the unit housing or its attendant components if this is explicitly specified in the operating instructions.
  • Only carry out work on the unit that is described in this manual. If problems cannot be overcome, please contact an authorised customer service point or, if in doubt, the manufacturer.
  • Never carry out technical changes to the unit.
  • Only use original spare parts and accessories for the unit.

Information about these operating instructions

Welcome to OASE Living Water. You made a good choice with the purchase of this product Eco Control.
Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit.
Ensure that all work on and with this unit is only carried out in accordance with these instructions.
Adhere to the safety information for the correct and safe use of the unit.
Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new owner.

Symbols used in these instructions
The warning information is categorised by signal words, which indicate the extent of the hazard.
WARNING

  • Indicates a possibly hazardous situation.
  • Non-observance may lead to death or serious injuries.

NOTE
Information for the purpose of clarification or for preventing possible damage to assets or to the environment.

Scope of delivery

A Description
1 AquaMax Eco Control
2 Retaining frame for fastening the device to the wall, or for fitting it to

the ground stake or holding clip
3| Ground stake
4| Holding clip for fastening the device to the pump handle

Product Description

Eco Control can be used to control EGC-capable OASE pumps.
Features:

  • Connection to the EGC socket of the pump.
  •  Illuminated display.
  • Does not require a separate power supply.
  • Control of the pump capacity, switching the Seasonal Function Control (SFC) and Dynamic Function Control (DFC) on or off, selection of programmes.
  • Allows display of the pump status and malfunctions.

Intended use
Eco Control, referred to as “unit”, may only be used as specified in the following:

  • Connection to OASE pumps with EGC connection, that are suitable for control via this device.
  • Operation under observance of the technical data.

Installation and connection
Fastening the device to the pump How to proceed:
B

  1. Fit the holding clip onto the pump handle.
  2. Slide the device onto the holding clip.
  3. Align the device.

Installing the device with the ground stake How to proceed:

C

  1. Fully insert the ground stake into the ground.
  2. Slide the device onto the ground stake.
  3. Check its stability.

Fastening the device to the wall How to proceed:

 D

1. Remove the retaining frame and fasten it to the wall using suitable screws.
2. Fit the device into the retaining frame.
– Ensure that the device is properly engaged in the retaining frame.

Connect the unit
How to proceed:
E

  1. Remove the protection cap from the unit.
  2. Fit the plug connector and secure with the two screws (max. 2.0 Nm).
    – Ensure that the rubber seal is clean and fits exactly.
    – Replace the rubber seal if damaged.
    – Only connect the plug to the left-hand EGC socket.

NOTE
The device will be destroyed if water penetrates the EGC sockets.

  • Close the EGC sockets with EGC plugs or a protection cap.

Operation

Control system overview

Oase 6600 Eco Control Digital Pump Controller - Control system
overview

Description Function
1 Two-line display with backlighting
2 LED ON/OFF Indicates whether the pump is switched on or off.
3 ON/OFF button For switching the pump on or off.
4 Arrow keys For changing values in the menus or selecting other lines in the

menu.
5 Mode button| For selecting the next menu in the display.
The selection is continuous. It continues from the last menu to the first menu.
6 LED MODE| Indicates the pump status.

Status displays

The LEDs signal the following statuses:

LED Status Description
LED ON/OFF Green The pump is switched on.
Off The pump is switched off.
LED MODE Green Seasonal Function Control (SFC) and/or Dynamic Function

Control (DFC) is activated
Red flashing| Malfunction (—> Error messages)
Off| SFC and/or DFC is deactovated

Menu: AquaMax Eco Expert / AquaMax Eco Titanium pump
When the AquaMax Eco Expert pump is connected, the following menus and setting possibilities are available.

Description

Oase 6600 Eco Control Digital Pump Controller -
Description

  • Connected pump (e.g. AquaMax Eco Expert 21000)  The pump is switched off.
    Setting

  • Switch on the pump via the ON/OFF button.

  • Connected pump (e.g. AquaMax Eco Expert 21000)

  • The pump is switched on.

Operating modes

  • : The speed is shown as a percentage (SFC is deactivated).
  • : SFC is activated (it is not possible to adjust the speed).
    – SFC mode (MIN, MID, MAX)

Adjustment (only for SPEED)

  • Change the speed using the arrow keys.
    Min. speed, Max. speed

Only display

  • (Seasonal Flow Control)
    – : Activated
    – OFF: Deactivated

  •  SFC-MoDE (MIN, MID, MAX)
    – SFC deactivated: No display

  • Select the next display using the arrow keys.

Only display

  • Current power consumption of the pump in watts
    – Display precision: ±5 % of the max. pump capacity

  • Current speed of the pump in rpm
     Select next/previous display using the arrow keys.

Only display

  • Total pump operating time in hours
  • Pump serial number
  • SFC is switched on.

Setting

  • Switch off SFC using the arrow key.
  • SFC is s witched off.

Setting

  • Switch on SFC using the arrow key.

Menu: Aquarius Eco Expert pump
When the Aquarius Eco Expert pump is connected, the following menus and setting possibilities are available.

Description

Oase 6600 Eco Control Digital Pump Controller -
Description2

  • Connected pump (e.g. Aquarius 28000)
  • The pump is switched off.

Setting

  • Connected pump (e.g. Aquarius 28000)
  • The pump is switched off.

Setting

  • Switch on the pump via the ON/OFF button.
  •  Connected pump (e.g. Aquarius 28000)
  • The pump is switched on.

Operating modes

  • : The speed is shown as a percentage (DFC is deactivated).

  •  : DFC is activated (it is not possible to adjust the speed).
    – DFC mode (SCENE 1 … SCENE 12)
    Adjustment (only for )

  • Change the speed using the arrow keys.
    Min. speed, Max. speed

Only display

  • DFC (Seasonal Flow Control)
    – Activated
    – : Deactivated

  • (SCENE 1 … SCENE 12)
    – DFC deactivated: No display

  • Select the next display using the arrow keys.

Only display

  •  Current power consumption of the pump in watts
    – Display precision: ±5 % of the max. pump capacity

  • Current speed of the pump in rpm

  • Select next/previous display using the arrow keys.

Only display

  • Total pump operating time in hours
  • Pump serial number
  • DFC is switched off.

Setting

  • Switch on DFC
  • DFC is switched on, program 1 is selected

Setting

  • Program selection (SCENE 1 … SCENE 12) and switching DFC off using the arrow keys

Error messages
Once a malfunction has been remedied, the error message automatically disappears.

Error message Cause Remedy
The pump has run dry (dry run protection has tripped). – Flood the pump.

– Fully submerge the pump for operation in a pond.
– Vent the supply line.
– Remove any blockage from the supply line.
Filter housing clogged (dry run protection has tripped).| Clean the pump.
| Impeller unit is blocked (dry run protection has tripped).| Disconnect the power supply and remove obstacle. Then
switch the pump on again.
| Ambient temperature for dry installation is too high.| – Avoid exposure to direct sunlight.
– Note maximum water temperature of +35°C.
Water temperature too high| Note maximum water temperature of +35°C.
| Current consumption too high
– Impeller unit running sluggishly
– Excessively soiled water| Clean the pump.

Storage/overwintering

The unit is frost-proof to -20 °C. If lower temperatures are expected, the unit must be removed and put into storage.
How to correctly store the unit:

  • Protect the EGC plug from moisture and dirt.

Wear parts
The following components are wear parts and are excluded from the warranty:

  • EGC plug seal

Disposal

NOTE
Do not dispose of this unit with domestic waste.

  • Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system provided for this purpose.

Spare parts
The use of original parts from OASE ensures continued safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare parts.

Oase 6600 Eco Control Digital Pump Controller - qr
code

www.oase-livingwater.com/spareparts

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals