Univox PLS-7 Induction Loop Amplifier Owner’s Manual

June 14, 2024
univox

Univox PLS-7 Induction Loop Amplifier

Univox-PLS-7-Induction-Loop-Amplifier-PRODUCT

Features

  • Dante PoE input for additional network audio (option)
  • High dynamic performance through linearized switching
  • High power – 100 Vpp & 20/2×10 Arms
  • Parametric metal loss compensation
  • Built-in system diagnostics
  • Fan-free convection cooling
  • Automatic safe mode
  • 50-100 V high voltage speaker input
  • High slew rate audio IC internally used
  • Fast-action AGC with an exceptional constant and stable linear output
  • Low-frequency masking filter – voice enhancement
  • Voltage peak indicator
  • Fault monitor indication LED
  • ULD supported for easy project planning
  • 5-year warranty

High-efficient linearized switching loop amplifier

Univox PLS-7 and its phased array sibling SLS-7 are powerful induction loop amplifiers designed for very large-area loop installations. PLS-7 delivers up to 100Vpp/20 Arms while the SLS-7 drives up to 100 Vpp and 10 Arms per channel. With wide dynamic response from complementary balanced outputs, PLS/SLS-7 drivers provide excellent dynamics with top audio quality. Our ground-breaking filter bank eliminates any Class-D associated non-linearity or interference. Due to la Class-D low heat dissipation, the drivers claim no extra ventilation space in your AV rack. Developed on Univox linear switching technology, with electronic transformers and fan-free design, PLS-7 and SLS-7 are two new long-life reliable products from Univox.

Intelligent system monitoring
Apart from the self-diagnostic system, PLS/SLS-7 features continuous monitoring of the input and output logic, warning for any inconsistency within the loop function. A built-in output relay allows for easy connection to a smart mixer or a monitor computer.

Enhanced metal loss compensation

  • Univox PLS/SLS linear tech series is equipped with a unique Parametric MLC (Metal Loss Compensation) control, enabling system frequency response correction in environments where the signal strength is strongly influenced by the surrounding metal.

Univox-PLS-7-Induction-Loop-Amplifier-FIG-1

Coverage

PLS-7 Free Field Moderate metal loss* High metal loss**
1:1 ratio Approx. 600 m2*** Approx. 50 m2*** Not recommended
1:2 ratio Approx. 1.200 m2 *** Approx. 100 m2 *** Not recommended
Figure 8 Approx. 4.200 m2 Approx. 2.300 m2 Approx. 1.000 m2
SLS-7 Free Field Moderate metal loss* High metal loss**
--- --- --- ---
Max coverage Approx. 4.200 m2 Approx. 2.000 m2 Approx. 1.000 m2
Low spill**** Approx. 1.200 m2 **** Approx. 100 m2 **** Not recommended
  • 4.5 dB attenuation, max 7 m loop segment width
  • 8 dB attenuation, max 4 m segment width
  • The larger coverage area is limited by the max 6 dB field strength variation stated by IEC 60118-4
  • SLS standard loop design (2m wide loop segments with cancellation segments)

Technical specifications

Univox PLS-7 Univox SLS-7

Induction Loop Output RMS 125 ms

  • Max drive voltage 100 Vpp 100 Vpp
  • Max drive current 20 Arms 2×10 Arms

Power

  • Power supply 110-240 VAC primary switched class VI electronic power supply
  • Power consumption, idle 137 mA 126 mA
  • @1.10 Ohm impedance load 80 W 45 W

Back panel interface

Input 1

  • Balanced XLR
  • Dip switch programmable: Low Cut Filter@150 Hz – Flat/Speech;
  • Line/Mic; Phantom Power +12 VDC On/Off
  • Sensitivity: -55 dBu (1.5 mVrms) to +10 dBu (2.6 Vrms)
  • Dante RJ45 Ethernet input PoE (option)

Input 2

  • Balanced Phoenix Screw Terminal Block
  • Dip switch programmable: Low Cut Filter@150 Hz – Flat/Speech; Line/50-100 V connection On/Off; Override On/Off
  • (Input 3 signals higher than -6 dB above AGC-knee overrides all other input signals)
  • Line sensitivity: -15 dBu (50 mVrms) to +20.6 dBu (8.3 Vrms)

Input 3

  • Unbalanced RCA or Phoenix Screw Terminal Block
  • Sensitivity: -24dBu (30 mVrms) to +16.2dBu (5 Vrms)

Monitor control

  • Recessed trim potentiometer for 10 W speaker and 3.5 mm front panel headphone output.
  • Phoenix Screw Terminal Block

Loop error

  • Speaker monitor output; 24 V power output; Relay output to the mixer
  • Phoenix Screw Terminal Block

Front panel interface

Input 1-3

  • Recessed trim pots; 4 LED input level indicators (-18 dB to +12 dB)

Parametric Metal Loss Control

  • Recessed trim pot, adjustable gain slope from 0 to 4 dB/octave;
  • Switchable frequency knee point (100 Hz, 500 Hz,1 kHz, 2 kHz)

System diagnostics

  • Checks Input connection, AGC, Pre and Power driver and Loop conductor with a pulsed 1.6kHz signal (built-in signal generator)
  • On/Off switch to operate the system, single LED indication
  • Loop current control Recessed trim pot; 4 LED output level indicator (0-9 dB)
  • Peak indicator LED indicates clipping due to voltage saturation
  • Loop fault indicator LED indicates an error in the loop function
  • Temp indicator Automatic safe mode activated
  • Monitor output 3.5 mm jack to monitor loop with headphones
  • The power indicator LED indicates the correct connection to a power supply

Other Functions

  • Frequency response: 75-6800 Hz
  • Distortion, power loop driver: < 0.05 %
  • Distortion, system: < 0.15 %
  • Dual action AGC: Dynamic Range: > 50-70 dB (+1.5 dB)
  • Attack time:   2-500 ms, Release time: 0.5-20 dB/s
  • Cooling: Fan-free convection cooling
  • IP class: IP20
  • Size: 1U/19 ” rack mount. Width 430 mm, Depth 146 mm, Height 44 mm (excl. rubber feet)
  • Weight (net): 2.30 kg 2.31 kg
  • Mounting options: Rackmount (brackets included), wall mount or freestanding (rubber feet pre-mounted)

Part No

  • 217700/217710 (Dante) 227000/227710 (Dante)

For the complete manual and certificate, please refer to univox.eu.

CONTACT

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals