Univox CLS-5T Compact Loop System Installation Guide

June 14, 2024
univox

Univox CLS-5T Compact Loop System

Univox -CLS-5T -Compact -Loop -System -product mage

Product Information

Introduction
Thank you for purchasing Univox® CLS-5T loop amplifier. We hope you will be satisfied with the product! Please read this user guide carefully before installation and usage of the product. Univox CLS-5T is a modern loop amplifier designed for wireless listening through T-coil equipped hearing devices. The high-current output, essential for optimal signal broad-casting and wide range of operating voltages,110-240 VAC and 12-24 VDC, supports its suitability for a number of applications, from on board vehicles to large TV- lounges and meeting rooms. Audio quality is significantly enhanced, eliminating modulation distortion at high power output. The audio chain incorporates also features such as the Metal Loss Correction, to fine tune for the effects of metal loss, and the unique Dual Action AGC(automatic gain control) that restores the audio instantly after noise suppression. CLS-5T features an alert input which can be activated by vehicles on-board alarm, or – if installed in a TV-lounge – a doorbell or a telephone. CLS-5T is certified according to the ECE R10 automotive standard, and correctly installed provides compliance with all the requirements of IEC 60118-4

Connections and controls CLS-5T

Front panel

Univox -CLS-5T -Compact -Loop -System -fig \(1\)

Rear panel

Univox -CLS-5T -Compact -Loop -System -fig \(2\)

Univox -CLS-5T -Compact -Loop -System -fig \(3\)

Description

  1. On/Off. Yellow LED indicates mains power connection
  2. In LED – Green. Input 1 and 2. Indicates signal source connection
  3. Loop LED – Blue. Indicates that loop is transmitting
  4. Loop connection terminal, pin 1 and 2
  5. In 1. Balanced line input, pin 8, 9, 10
  6. Loop current adjustment
  7. In 2. RCA/Phono
  8. In 1, volume control
  9. 12-24VDC supply (see polarity below)
  10. 110-240VAC, external switching power supply
  11. Digital input, optical
  12. Digital input, coax
  13. Alert signal system, pin 3 through 7 – see pages 7-8 ’Connecting an alert signal’

Specifications

  • Product Name: Univox CLS-5T
  • Part Number: 212060
  • Power Supply Options: DC power supply connection (12 or 24VDC)
  • Power Source: External power adapter or 12-24VDC power source
  • Input Signal Sources: In 1, In 2
  • Loop Connection Terminal: Loop (4)
  • Alert Signal Triggers: External doorbell drive, External trigger, External switch
  • Website: www.univox.eu

Product Usage Instructions

User information
CLS-5T should be installed and adjusted by a qualified technician. No maintenance is normally required. In the event of malfunction, do not attempt to repair the amplifier yourself.

Mounting and Placement
The Univox CLS-5T can be wall-mounted or placed on a flat and stable surface. When wall-mounting, please refer to the template provided in the Installation Guide. The wires between the loop configuration and the driver should not exceed 10 meters and should be paired or twisted. It is important to ensure adequate ventilation for the amplifier by providing free space on all sides. CLS-5T can be wall-mounted (see template for wall mounting at the end of this Installation Guide) or placed on a flat and stable surface. The wires between the loop figuration and the driver should not exceed 10 meters and should be paired or twisted.
Important: The placement location must provide adequate unit ventilation.
The amplifier normally generates heat during operation and needs free space for plenty of ventilation on all sides.

Installation Setup

There are two power supply options available for the Univox CLS-5T:

  • 12-24VDC direct power source
  • 110-240VAC External switching power supply DC power supply connection

DC Power Supply Connection: Connect a 12 or 24VDC direct power source to the amplifier via a 5-8A external fuse. If using Unbalanced In 2, install a FGA-40HQ ground isolator (part no: 286022) between the loop amplifier input and the signal source to prevent serious errors.

  1. Connect the loop wire to the amplifier’s loop connection terminal, marked Loop (4.)
  2. Connect a suitable input signal source to one of the Inputs, In 1 or In 2
  3. Connect the amplifier to mains by using the external power adapter or a 12-24VDC power source (10.) via 2-p Molex connector (9.). Observe polarity. Yellow LED (1.) illuminated

Molex connector polarity

Mains Power Supply Connection: Connect the amplifier to mains power using the external power adapter or a 12-24VDC power source via a 2-p Molex connector. Observe the polarity indicated by the Yellow LED.

Default Settings

  1. Check that there is an input signal by ensuring the green LED In (2) is illuminated during program peaks.
  2. Adjust the magnetic field strength to 0dB (400mA/m) in the program peaks. Verify the settings accordingly.  Verify the  field strength with Univox® FSM field strength meter. Check the sound quality with the loop reciever, Univox® Listener? Some installations require adjustment of treble level. The treble control is located inside the CLS-5T (single control potentiometer inside the unit). When increasing the treble there is an increased risk of self-oscillation and distortion. Please contact Univox support for guidance.

Special Settings for TV Connection

  • Digital in (11-12.)
    Connect with optical or coax cable to TV models with digital input

  • RCA/phono (7.)
    Connect the TV’s audio output (AUDIO OUT or AUX OUT) to In 3 RCA/phono (7?)

To connect an alert signal system, follow these steps:

  1. External Doorbell Drive: Connect a +24VDC doorbell to Terminal 3-6 on the terminal block.
  2. External Trigger: Connect a 5-24V AC/DC signal to Terminal 4-5 on the terminal block.
  3. External Switch: Connect an external switch between Terminals 3-4 and 5-7. The acoustic indication will suppress the sound in the loop and initiate a broadband harmonic sound to cover most non-linear frequency hearing impairments.

Connecting an alert signal
An alert signal system can be triggered in three ways:

  1. External doorbell drive: +24VDC doorbell. Terminal 3-6 on the terminal block
  2. External trigger: 5-24V AC/DC. Terminal 4-5 on the terminal block
  3. External switch: Terminal 3-4 and 5-7 are shorted separately. The external switch is connected between 3-4 and 5-7

The acoustic indication supresses the sound in the loop and initiates a broadband harmonic sound that covers most of the non-linear frequency hearing impairments.

Loop Installation Guidance

For detailed loop installation guidance, please visit www.univox.eu/support /consultation-and-support/certify-installation/

  • The installation should initially be planned with a 2 x 1.5mm² paired wire. Connect the wires in series as a 2-turn loop. If the desired field strength is not achieved, connect the wires in parallel creating a 1-turn loop.In installations where a standard round wire is not suitable e.g. due to limited space, flat copper foil is recommended.
  • Venues with reinforced structures can reduce the coverage area significantly.
  • Analog signal cables should not be placed closely or in parallel to the loop wire.
  • Avoid dynamic microphones to reduce the risk of magnetic feedback.
  • The loop should not be installed closely to or directly on metal constructions or reinforced structures. The field strength might be reduced substantially.
  • If the shortest side of the loop area is longer than 10 meters, a figure eight loop configuration should be installed.
  • Verify that the overspill outside of the loop is acceptable. If not, a Univox® SLS system should be installed.
  • Relocate any electrical equipment that could create background magnetic field signals or interference with the loop system.
  • In order to avoid feedback from electronic instruments and dynamic microphones, do not install wire near a stage area.
  • A completely installed loop system should be tested with Univox® FSM field strength meter and certified according to the IEC 60118-4 standard.
  • Univox Certificate of conformity, including a measurement procedure checklist, is avaliable at: www.univox.eu/support/consultation-and-support/certify-installation/

System Check/Troubleshooting

  1. Ensure that the amplifier is connected to mains power (Yellow LED illuminated).
  2. Proceed to the next troubleshooting steps.
  3. Check that the amplifier is connected to the mains power (yellow LED illuminated).Proceed to step 2.
  4. Check the input connections. The cable between the amplifier and the signal source/s (TV, DVD, radio etc.) must be properly connected, (green LED “In” illuminated). Proceed to step 2.
  5. Check the loop cable connection, (blue LED). The LED is illuminated only if the amplifier is transmitting sound to the hearing aid and the system is working correctly. If you are not receiving an audio signal in your hearing aid, verify that the hearing aid is functioning properly and is set in T-position.

Safety

The equipment should be installed by an audio visual technician observing ‘good electrical and audio practice’ at all times and following all the instructions within this document. Only use the power adapter supplied with the unit. If the power adapter or cable is damaged, replace with a genuine Univox part. Power adapter must be connected to a mains outlet close to the amplifier and easily accessible. Connect the power to the amplifier before connecting to the network, otherwise there is a risk of sparking.  The installer is responsible for installing the product in a way that may not cause risk of fire, electrical malfunctions or danger for the user. Do not cover the power adapter or loop driver. Only operate the unit in a well ventilated, dry environment. Do not remove any covers as there is a risk of electric shock. There are no user serviceable parts inside. Refer servicing to qualified personnel. Please observe that the product warranty does not include faults caused by tampering with the product, carelessness, incorrect connection/mounting or maintenance. Bo Edin AB shall not be held responsible or liable for interference to radio or TV equipment, and/or to any direct, incidental or consequential damages or losses to any person or entity, if the equipment has been installed by unqualified personnel and/or if installation instructions stated in the product Installation Guide have not been strictly followed.

Warranty

This loop driver is supplied with a 5-year (return to base) warranty.

Misuse of the product in any way including but not limited to:

  • Incorrect installation
  • Connection to non-approved power adapter
  • Self oscillation resulting from feedback
  • Force majeure e.g. lightning strike
  • Ingress of liquid
  • Mechanical impact will invalidate the warranty.

Measuring devices
Univox® FSM Basic, Field Strength Meter
Professional instrument for measurement and certification of loop systems in accordance with IEC 60118-4.

Univox® Listener, testing device
Loop receiver for fast and simple check of the sound quality and basic level control of the loop. The installation guide is based on information avaliable at the time of printing and is subject to change without notice.

Maintenance and care
Under normal circumstances the product does not need any special maintenance. Should the unit become dirty, wipe it with a clean damp cloth. Do not use any solvents or detergents.

Service
If the product / system is not working properly after completing the troubleshooting procedure, please contact your local distributor od Bo Edin directly for further instructions. The appropriate Service form, available at www.univox.eu, should be completed before sending any products back to Bo Edin AB for technical consultation, repair or replacement.

Technical data
For additional information, please refer to product data sheet and CE certificate which can be downloaded from www.univox.eu/products. If required, other technical documents can be ordered from [email protected].

Environment
To prevent possible harm to the environment and human health, please dispose of the product responsibly by following statutory disposal regulations.

Technnical specifications CLS-5T

Induction loop output: RMS 125 ms

  • Power supply   110-240 VAC, external switching power supply 12-24 VDC as primary power or backup, 12 V will reduce output
  • Loop output
  • Max current 10 Arms
  • Max voltage   24 Vpp
  • Frequency range 55 Hz to 9870 Hz @ 1Ω and 100μH
  • Distortion    <1% @ 1Ω DC and 80μH
  • Connection   Phoenix screw terminal

Inputs

  • Digital   Optical/coax

  • In 1    Phoenix connector/balanced input/PIN 8/10 8 mV, 1.1 Vrms/5kΩ

  • In 2 RCA/phono, RCA – unbalanced input: 15 mV, 3,5 Vrms/5kΩ

  • Indication External door bell/telephone signal or trigger voltage can activate the built-in alerting system with tone generator in the loop.

  • Metal loss correction/treble control
    0 to +18 dB correction of high frequency attenuation – internal control

  • Loop current
    Loop current (6.)   Screwdriver adjusted

  • Indicators

  • Power connection  Yellow LED (1.)

  • Input    Green LED (2.)

  • Loop current   Blue LED (3.)

  • Size     WxHxD 210 mm x 45 mm x 130 mm

  • Weight (net/gross)  1.06 kg 1.22 kg

  • Part No   212060

Product is designed to meet the system requirements of IEC60118-4, when correctly designed, installed, commissioned and maintained. Specification data complied according to IEC62489-1. The installation guide is based on information available at the time of printing and is subject to change without notice.

FAQ

  1. Q: Can I install and adjust the CLS-5T myself?
    A: No, it is recommended that a qualified technician installs and adjusts the CLS-5T. Do not attempt to repair the amplifier yourself in case of malfunction.

  2. Q: Is any maintenance required for the CLS-5T?
    A: No, normally no maintenance is required for the CLS-5T.

  3. Q: What should I do if there is a malfunction?
    A: In case of malfunction, do not attempt to repair the amplifier yourself. Contact a qualified technician for assistance.

  4. Q: How far can the wires between the loop configuration and the driver be?
    A: The wires should not exceed 10 meters in length and should be paired or twisted.

  5. Q: Why is adequate ventilation important for the CLS-5T?
    A: The amplifier generates heat during operation, and sufficient ventilation on all sides ensures proper cooling and prevents overheating.

(Univox) Bo Edin AB Stockby Hantverksby 3, SE-181 75 Lidingö, Sweden

Hearing excellence since 1965

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

univox User Manuals

Related Manuals