MEAN WELL GST18A05-P1J 18W AC-DC Reliable Green Industrial Adaptor Owner’s Manual

June 14, 2024
MEAN WELL

MEAN-WELL-logo

MEAN WELL GST18A05-P1J 18W AC-DC Reliable Green Industrial Adaptor

Product Information

Specifications

  • Model : GST18A series
  • Input : Universal AC input / Full range
  • Output : DC voltage
  • Power : 18W (max.)
  • No load power consumption : < 0.075W
  • Protections : Short circuit / Overload / Over voltage
  • Working temperature : -30°C to +70°C
  • LED indicator for power on
  • Various DC plug quick adapter accessories available (Plug kit sold separately)
  • Warranty : 3 years

Description
The GST18A series is a reliable and efficient green industrial adaptor. It is designed for use in a wide range of applications, including consumer electronic devices, telecommunication devices, office facilities, and industrial equipment. The adaptor features a fully enclosed plastic case and a 3-pole AC inlet IEC320-C14. It has a no-load power consumption of less than 0.075W and complies with energy efficiency Level VI standards.

Model Encoding
The model encoding for the GST18A series is as follows:

  • DC plug type: P1J (Standard model, 2.1×5.5x11mm, C+, tuning fork type)
  • Output voltage: Varies based on the model (refer to the specifications section)

Product Usage Instructions

  • Step 1: Check the Input Voltage
    Before connecting the industrial adaptor, ensure that the input voltage matches the specifications. The GST18A series supports a universal AC input range of 85VAC to 264VAC.

  • Step 2: Connect the AC Power
    Plug the 3-pole AC inlet IEC320-C14 of the industrial adaptor into a suitable AC power source.

  • Step 3: Connect the DC Output
    Choose the appropriate DC plug from the various quick adapter accessories available. Connect the chosen DC plug to the outputport of the industrial adaptor.

  • Step 4: Power On
    Once the AC power and DC output are properly connected, the LED indicator on the industrial adaptor will light up, indicating that power is on.

FAQ

What are the protections provided by the GST18A series industrial adaptor?
The GST18A series provides protection against short circuits, overload, and over voltage.

What is the working temperature range of the industrial adaptor?
The industrial adaptor can operate in a wide temperature range of -30°C to +70°C.

Are there any certifications for the GST18A series?
Yes, the GST18A series has certifications such as UL62368-1, Bauart gepruft, BS EN/EN62368-1, R33100 RoHS, J62368-1, K60950-1 AS/NZS60950-1 GB4943.1 IS13252, MS IEC60950-1 IEC62368-1 (optional), and more.

Features

  • Global certificates
  • Universal AC input / Full range
  • 3 pole AC inlet IEC320-C14,Class 1 power unit
  • No load power consumption< 0.075W
  • Energy efficiency Level VI
  • Comply with EISA 2007/DoE,NRCan,Korea K-MEPS, AU/NZ MEPS,EU ErP and CoC Version 5
  • Protections: Short circuit / Overload / Over voltage
  • Fully enclosed plastic case
  • Pass LPS
  • -30~+70°C wide range working temperature
  • LED indicator for power on
  • Various DC plua quick adapter accessorv available (Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf)
  • 3 years warranty

Applications

  • Consumer electronic devices
  • Telecommunication devices
  • Office facilities
  • Industrial equipments

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

GST18A is a highly reliable, 18W desktop style single-output green adaptor series. This product is a class I power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from 85VAC to 264VAC. The entire series supplies different models with output voltages ranging between 5VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices. With the efficiency up to 89% and the extremely low no-load power consumption below 0.075W, GST18A is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea K-MEPS, EU ErP, and Code of Conduct(CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case.GST18A is certified for the international safety regulations.

Model EncodingMEAN-WELL-GST18A05-P1J-18W-AC-DC-Reliable-Green-Industrial-
Adaptor-fig- \(1\)

SPECIFICATION

ORDER NO.| GST18A05- P1J| GST18A07- P1J| GST18A09- P1J| GST18A12- P1J| GST18A15- P1J| GST18A18- P1J| GST18A24- P1J| GST18A28- P1J| GST18A48- P1J
---|---|---|---|---|---|---|---|---|---








OUTPUT

| SAFETY MODEL NO.| GST18A05| GST18A07| GST18A09| GST18A12| GST18A15| GST18A18| GST18A24| GST18A28| GST18A48
DC VOLTAGE Note.2| 5V| 7.5V| 9V| 12V| 15V| 18V| 24V| 28V| 48V
RATED CURRENT| 3.0A| 2.0A| 2.0A| 1.50A| 1.20A| 1.0A| 0.75A| 0.64A| 0.375A
CURRENT RANGE| 0 ~ 3.0A| 0 ~ 2.0A| 0 ~2.0A| 0 ~ 1.50A| 0 ~ 1.20A| 0 ~ 1.0A| 0 ~ 0.75A| 0 ~ 0.64A| 0 ~ 0.375A
RATED POWER (max.)| 15W| 15W| 18W| 18W| 18W| 18W| 18W| 18W| 18W
RIPPLE & NOISE (max.) **Note.3| 80mVp-p| 80mVp-p| 80mVp-p| 80mVp-p| 100mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p
VOLTAGE TOLERANCE Note.4| ±5.0%| ±5.0%| ±5.0%| ±3.0%| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±2.0%
LINE REGULATION Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION Note.6| ±5.0%| ±5.0%| ±5.0%| ±3.0%| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±2.0%
SETUP, RISE, HOLD UP TIME**| 1000ms, 30ms, 50ms/230VAC            1500ms, 30ms, 15ms/115VAC at full load




INPUT

| VOLTAGE RANGE Note.7| 85 ~ 264VAC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 81%| 85%| 85%| 86%| 87%| 88%| 88%| 88.5%| 89%
AC CURRENT| 0.5A / 115VAC           0.3A / 230VAC
INRUSH CURRENT (max.)| Cold start 35A / 115VAC           65A / 230VAC
LEAKAGE CURRENT(max.)| 0.75mA / 240VAC



PROTECTION

| ****

OVERLOAD

| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed


OVER VOLTAGE

| 110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short




ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% / ℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes















SAFETY & EMC

(Note. 9)

| SAFETY STANDARDS Note. 8| UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, BSMI CNS 14336-1 , CCC GB4943.1, PSE J62368-1, AS/NZS 60950.1,BIS IS13252, KC K60950-1, EAC TP TC 004 approved; SIRIM MS IEC62368-1 (optional) approved
WITHSTAND VOLTAGE| I/P-O/P:4242VDC , I/P-FG:2121VDC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH






EMC EMISSION

| Parameter| Standard| Test Level / Note


Conducted emission

| BS EN/EN55032(CISPR32),FCC PART 15/CISPR22 CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32| ****

Class B


Radiated emission

| BS EN/EN55032(CISPR32),FCC PART 15/CISPR22 CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32| ****

Class B

Harmonic current| BS EN/EN61000-3-2,GB9254| Class A
Voltage flicker| BS EN/EN61000-3-3| ——-







EMC IMMUNITY

| BS EN/EN55035
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 2, 3V/m
EFT bursts| BS EN/EN61000-4-4| Level 2, 1KV
Surge susceptibility| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line , 2KV/Line-FG
Conducted susceptibility| BS EN/EN61000-4-6| Level 2, 3V
Magnetic field immunity| BS EN/EN61000-4-8| Level 2, 3A/m
Voltage dips , interruption| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods


OTHERS

| MTBF| 3879.7K hrs min.       Telcordia SR-332 (Bellcore) ; 668.4K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION| 935436mm (LWH)
PACKING| 209g; 60pcs/13.5Kg/1.02CUFT


CONNECTOR

| PLUG| See page 4~5 ; Other type available by customer requested
CABLE| See page 4~5 ; Other type available by customer requested






NOTE

| 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.

3.Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1μf & 47μf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation.

5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 10% to 100% rated load.

7. Derating may be needed under low input voltage. Please check the derating curve for more details.

8. The demand for Malaysia safety is processed with the order no. GST18A -SIRIM by request. Please contact MEAN WELL for details.

9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on http://www.meanwell.com)

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Derating Curve

Static Characteristics

Mechanical SpecificationMEAN-WELL-GST18A05-P1J-18W-AC-DC-Reliable-Green-
Industrial-Adaptor-fig- \(4\) MEAN-WELL-GST18A05-P1J-18W-AC-DC-Reliable-Green-Industrial-Adaptor-fig-
\(5\)

DC output plug

Standard plug : P1JMEAN-WELL-GST18A05-P1J-18W-AC-DC-Reliable-Green-
Industrial-Adaptor-fig- \(6\)

DC plug changeable through:

  1. Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
  2. Quick adapter accessory (sold separately without MOQ)

Please refer to below table and online selection guide: https://www.meanwell.com/upload/pdf/DC_plug.pdf

Example quick adapter accessory:

MEAN-WELL-GST18A05-P1J-18W-AC-DC-Reliable-Green-Industrial-Adaptor-fig-
\(7\)

Optional DC plug :
(Available in customized cable or quick adapter)

MEAN-WELL-GST18A05-P1J-18W-AC-DC-Reliable-Green-Industrial-Adaptor-fig-
\(8\) MEAN-WELL-GST18A05
-P1J-18W-AC-DC-Reliable-Green-Industrial-Adaptor-fig-
\(9\) MEAN-WELL-GST18A05
-P1J-18W-AC-DC-Reliable-Green-Industrial-Adaptor-fig-
\(10\)

Installation Manual

Please refer to: http://www.meanwell.com/manual.html

Downloaded from Arrow.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals