SCS 724 Workstation Monitor
Product Information
Specifications
- Product Name: SCS 724 Workstation Monitor
- Model: TB-9013
- Country of Origin: United States of America
- Compliance: Meets ANSI/ESD S20.20 and ESD Handbook ESD TR20.20 standards
Description
The SCS 724 Workstation Monitor is a reliable device that continuously monitors the path-to-ground integrity of two operators and one conductive or dissipative worksurface. It is specifically designed and tested for use with SCS Dual-Wire Wrist Straps and Worksurface Mats. Please note that using the equipment in any other manner not specified in the instructions may impair its protection and lead to an unsafe condition.
Features
- Continuous monitoring of path-to-ground integrity
- Supports two operators and one worksurface
- Compatible with SCS Dual-Wire Wrist Straps and Worksurface Mats
- Meets ANSI/ESD S20.20 and ESD Handbook ESD TR20.20 standards
Components
- 724 Workstation Monitor
- 732 Dual Operator Remote
- Dual Operator Remote Cable
- Power Adapter (North America)
- Monitor Ground Cord
- 2380D Mat Monitor Cord (with Diode)
- Two-Wire Terminal Block
- Long Mounting Screws (2)
- Short Mounting Screws (2)
- Cable Tie Mounts (2)
- Zip Ties (2)
- Certificate of Calibration
Theory of Operation
The SCS 724 Workstation Monitor operates based on the following components:
- Operator Remote Jack #1: Connect the dual-wire wrist cord of operator #1 here to monitor their connection to ground.
- Operator Remote Jack #2: Connect the dual-wire wrist cord of operator #2 here to monitor their connection to ground.
Product Usage Instructions
Installation
- Choose a suitable location for the 724 Workstation Monitor near the operators and worksurface.
- Securely mount the monitor using the provided long and short mounting screws.
- Connect the power adapter to the appropriate power source, depending on the model.
- Attach the dual operator remote to the monitor using the dual operator remote cable.
- Connect the monitor ground cord to a reliable ground point.
- Connect the mat monitor cord to the worksurface mat using the provided diode.
- Connect the two-wire terminal block to the monitor.
Operation
- Ensure that both operators are wearing SCS Dual-Wire Wrist Straps.
- Connect operator #1’s dual-wire wrist cord to Operator Remote Jack #1.
- Connect operator #2’s dual-wire wrist cord to Operator Remote Jack #2.
- Verify that the monitor is powered on and functioning properly.
Maintenance
To ensure the continued performance and reliability of the SCS 724 Workstation Monitor, follow these maintenance guidelines:
- Regularly inspect all connections and cables for damage or wear.
- Clean the monitor and accessories using a mild, non-abrasive cleanser.
- Calibrate the monitor annually or as recommended by SCS.
- Refer to the user manual for detailed maintenance instructions.
FAQ
Q: What does the SCS 724 Workstation Monitor continuously monitor?
A: The SCS 724 Workstation Monitor continuously monitors the path-to-
ground integrity of two operators and one conductive or dissipative
worksurface.
Q: What standards does the SCS 724 Workstation Monitor meet?
A: The SCS 724 Workstation Monitor meets the requirements of ANSI/ESD
S20.20 and recommendations of ESD Handbook ESD TR20.20.
Q: Can the SCS 724 Workstation Monitor be used with any other wrist straps
or worksurface mats?
A: No, the SCS 724 Workstation Monitor is specifically designed and
tested for use with SCS Dual-Wire Wrist Straps and Worksurface Mats. Using it
with other products may impair its protection and lead to an unsafe condition.
724 Workstation Monitor
Installation, Operation and Maintenance
Description
The SCS 724 Workstation Monitor continuously monitors the path-to-ground
integrity of two operators and one conductive or dissipative worksurface. It
has been designed and tested for use with SCS Dual-Wire Wrist Straps and
Worksurface Mats. If the equipment is used in a manner not specified in these
instructions, the protection provided by the equipment may be impaired.
Use in any other application has not been evaluated by SCS and may lead to an
unsafe condition.
The SCS 724 Workstation Monitor meets the requirements of ANSI/ESD S20.20 and recommendations of ESD Handbook ESD TR20.20 which includes “if the products that are being produced are of such value that knowledge of a continuous, reliable ground is needed, and then continuous monitoring should be considered or even required”.
The 724 Workstation Monitor is available in three models:
Item | Description |
---|
724| 724 Workstation Monitor,
North America Power Adapter
724MO| 724 Workstation
Monitor, No Power Adapter
The following accessories are available for the 724 Workstation Monitor:
Item | Description |
---|
770065| Verification Tester
724P| Power Adapter, 120VAC
Input, 25VDC Output, North America Plug
724-PSEU| Power Adapter,
100-240VAC Input, 24VDC Output, UK & Euro Plugs
732| Dual Operator Remote
733| Operator Remote
770037| Replacement Terminal
Block, Pack of 5
770735| Replacement Nylon Plug
for 733 Operator Remote, Pack of 20
3057| Standby Jack
2389| Mat Interconnect Cord, 10′
2380D| Mat Monitor Cord, with
Diode, 6′
Packaging
724 Workstation Monitor, North America
- 1 724 Workstation Monitor
- 1 732 Dual Operator Remote
- 1 Dual Operator Remote Cable
- 1 Power Adapter, North America
- 1 Monitor Ground Cord
- 1 2380D Mat Monitor Cord
- 1 Two-Wire Terminal Block
- 2 Long Mounting Screws
- 2 Short Mounting Screws
- 2 Cable Tie Mounts
- 2 Zip Ties
- 1 Certificate of Calibration
724MO Workstation Monitor, No Power Adapter
- 1 724 Workstation Monitor
- 1 732 Dual Operator Remote
- 1 Dual Operator Remote Cable
- 1 Monitor Ground Cord
- 1 2380D Mat Monitor Cord
- 1 Two-Wire Terminal Block
- 2 Long Mounting Screws
- 2 Short Mounting Screws
- 2 Cable Tie Mounts
- 2 Zip Ties
- 1 Certificate of Calibration
724K-WM11 Workstation Monitor Kit
- 1 724 Workstation Monitor
- 1 732 Dual Operator Remote
- 1 Dual Operator Remote Cable
- 1 Power Adapter, North America
- 1 Monitor Ground Cord
- 1 2380D Mat Monitor Cord
- 1 Two-Wire Terminal Block
- 2 Long Mounting Screws
- 2 Short Mounting Screws
- 2 Cable Tie Mounts
- 2 Zip Ties
- 1 2368 Elastic Dual-Wire Wristband
- 1 2360 Dual-Wire Wrist Cord
- 1 8811 Worksurface Mat Kit
- 1 Certificate of Calibration
Theory of Operation
The SCS 724 Workstation Monitor is designed to monitor the operation of the
wrist strap grounding systems of two operators. To accomplish this, it uses a
DC current source to measure a loop electrical resistance. The system uses a
special wristband and wrist cord that contain two independent elements.
The 724 Workstation Monitor employs two selectable test voltages (9 and 16
volts) and resistance limits (10 Megohms and 35 Megohms). It also monitors the
grounding of one worksurface mat. The Workstation Monitor contains a current-
limiting resistor. Resistance is monitored as the test voltage passes through
one side of the wristband, through the skin of the wearer under the band,
through the second side of the wristband, through the second conductor of the
wrist cord that contains a current-limiting resistor, and finally back to the
monitor.
NOTE: There is no power switch or power indication LED. LEDs will illuminate once a wrist strap is connected to the operator remote.
Features and Components
- A. Operator Remote Jack #1: Connect the dual-wire wrist cord of operator #1 here to monitor their connection to ground.
- B. Operator Remote Jack #2: Connect the dual-wire wrist cord of operator #2 here to monitor their connection to ground.
- C. Operator #1 Pass LED: Illuminates green when operator #1 is properly grounded.
- D. Operator #2 Pass LED: Illuminates green when operator #2 is properly grounded.
- E. Operator Fail High LED: Illuminates red when either operator #1 or #2 fail high. The buzzer will sound continuously when operator #1 is at fault, and it will sound intermittently when operator #2 is at fault.
- F. Operator Fail Low LED: Flashes yellow when either operator #1 or #2 fail low.
- G. Worksurface Mat Fail LED: Illuminates red and alarm sounds when the worksurface mat is not properly grounded.
- H. Operator Test Limit and Test Voltage Switches:
The operator test limits may be set to either 10 megohms or 35 megohms, and
the operator test voltage may be set to either 9V or 16V. The additional
ranges have been added to accommodate global electrical static discharge
requirements.
Selection of the operating parameters are left up to the user’s discretion.
OPERATOR MONITORING
The wrist strap monitoring function is activated by plugging a wrist strap
dual conductor ground cord into either one of the jacks on the SCS 732 or 733
Operator Remote. If the resistance of the wrist strap loop is within the
limits of the selected range (1.5 Megohms to 10 Megohms or 1.5 Megohms to 35
Megohms) on the Workstation Monitor, the cord, the wristband, and the contact
to the arm of the wearer, it is considered to be functioning correctly. At
this time, one of the (OK) green LEDs (1 or 2) will be illuminated on the
front of the monitor.
The wrist strap of the second operator is measured in the same way. Operators
are identified by the two (OK)green LEDs (1 & 2). However, the same high wrist
strap red LED (H) and low yellow (L) LED illuminate when a fault is detected.
The green LED that extinguishes identifies the operator that is experiencing
the fault condition.
If the resistance of the wrist strap loop is higher than the selected range
(10 Megohms or 35 Megohms) on the Workstation Monitor, an (OK) wrist strap
green LED (1 or 2) extinguishes, and a high wrist strap red LED (H)
illuminates with an audible alarm. This is an indication of a high resistance
in the wristband, or poor contact between arm and band. If the resistance in
the loop is under 1.5 Megohms, it is an indication of a low resistance meaning
one or both current-limiting resistors are bypassed. The low yellow LED (L)
will flash and an (OK) green LED (1 or 2) will remain illuminated.
OPERATOR TEST VOLTAGE
There is a concern about the voltage that is applied to an operator while they
are connected to a monitor.
Some of today’s electronic components are extremely sensitive to electrostatic
discharge from a person (less than 10 volts). The user should determine if
these voltages can damage the device being handled.
The following chart for the 724 Workstation Monitor illustrates the level of
voltage that will appear on the operator under various resistance conditions.
A low resistance condition also can be caused by touching a grounded object or
by standing on a conductive surface. This may trigger the low resistance alarm
on the 724 Workstation Monitor.
Condition| 9V-10
Megohms
| 9V-35
Megohms
| 16V-10
Megohms
| 16V-35
Megohms
---|---|---|---|---
No Skin Resistance| 0.9V| 0.9V| 1.6V| 1.6V
200K Ohm
Skin Resistance
|
1.0V
|
1.0V
|
1.8V
|
1.8V
Likely Case Before Alarm|
2.5V
|
3.6V
|
4.4V
|
6.4V
Worst Case Before Alarm|
4.5V
|
7.1V
|
8.0V
|
12.6V
Absolute Worst Case| 9.0V| 9.0V| 16.0V| 16.0V
AUDIBLE ALARM SETTINGS
For wrist strap malfunctions, the 724 Workstation
Monitor indicates a different tone for each operator – a continuous tone for
operator #1 and a fast chirping beep for operator #2. The volume of the wrist
strap alarm is adjusted by selection of the internal DIP switch 1. For
worksurface malfunctions, a slow chirping beep is made.
This alarm sound is turned on or off by selection of DIP switch 2. The DIP
switches are accessible through a slot located on the bottom side of the
monitor.
WORKSURFACE MONITORING
The 724 Workstation Monitor monitors its connection to ground and the
grounding of a worksurface. A loop resistance is measured from the monitor,
through the mat monitor cord to the worksurface, across the conductive layer
of the worksurface, through the grounding wire of the worksurface to an
electrical ground and finally back to the monitor through the monitor’s ground
wire. If the resistance of the loop exceeds 3.7 Megohms, the worksurface high
red LED (M) will illuminate and all green LEDs will be extinguished. If
audible alarm DIP switch 2 is in the ON position (Figure 5), the audible alarm
will activate. If no ESD worksurface is to be monitored, the mat monitor cord
and the ground wire of the 724 Workstation Monitor must be connected to an
electrical ground. This is done to ensure that the 724 Workstation Monitor is
providing a ground connection for the operators. Again, if the loop resistance
exceeds 3.7 Megohms, the worksurface high red LED (M) will illuminate and the
audible alarm will sound if enabled.
The ground wire from the worksurface and the ground wire from the 724
Workstation Monitor must be attached to separate electrical grounds. The
worksurface monitoring function is active whenever the monitor is powered.
Disconnect the mat monitor cord to prevent possible damage to the 724
Workstation Monitor before testing the resistance of the worksurface with a
high voltage megohmmeter.
Installation
- Remove the monitor from the carton and inspect for damage.
- Determine the mounting location of the 724 Workstation Monitor. The front panel should be visible to the operator(s). Use the included short screws if desired.
- Connect the 724 Workstation Monitor to the 732 Dual Operator Remote using the included cable.
- Determine the mounting location of the 732 Dual Operator Remote. The front panel should be accessible to the operator(s). Use the included long screws if desired.
- Locate the black two-wire terminal block that is packaged with the monitor. Use a small blade screwdriver to secure the mat monitor cord and ground cord to their respective terminals in the terminal block.
- The 724 Workstation Monitor may be grounded using either its North American power adapter or the included green monitor ground cord. See Figures 7 and 8.
- Plug the two-wire terminal block into the back of the 724 Workstation Monitor.
- Route the mat monitor cord from the back of the monitor to the grounded worksurface mat. Use the SCS 3034 or 3050 10mm Female Socket to secure the cord to the worksurface mat.
- If using the monitor ground cord, attach its ring terminal to a ground point. It is important that this ground cord is attached to a different ground point than that of the worksurface mat. The face plate screw of a grounded AC wall outlet may provide a convenient connection point.
- Connect the power adapter to the power jack located on the back of the monitor. Route the wire from the supply to a nearby AC outlet, and plug it into the outlet. Make sure the voltage and frequency match those listed on the power supply. The monitor is now powered.
NOTE: Worksurface must have a conductive layer. SCS continuous monitors are not recommended for use with homogeneous matting.
Operation
USING THE MONITOR
- Fit the wristband snugly onto your wrist.
- Connect the wrist cord to the wristband.
- Plug the wrist cord into the monitored jack labeled “1” on the 732 Dual Operator Remote. The corresponding operator LED will illuminate solid green on the 724 Workstation Monitor. This indicates that the operator is properly grounded.
- If this does not happen, examine the wrist cord for continuity or damage and your wristband to ensure that it fits securely. If you have dry skin, apply an approved dissipative hand lotion such as Menda Reztore™ ESD Hand Lotion.
FAULT CONDITIONS
- Red Wrist Strap LED (H) & Audible Alarm This indicates that a high resistance condition (greater than 10 Megohms or 35 Megohms) exists for an operator or wrist strap assembly. If two operators are connected to the monitor the high condition is with the operator whose green LED has extinguished. Check the operator for good contact between the wrist and band. Check the ground cord and connections for continuity. Some operators have difficulty in providing sufficient continuity to the wristband due to dry skin or arm hair. They may need to reposition the wristband on the arm or use an approved skin moisturizer such as Menda Reztore™ ESD Hand Lotion.
- Yellow Wrist Strap LED (L) & No Audible Alarm This indicates that a low resistance condition (less than 1.5 Megohms) exists between the operator and ground. One or both of the one megohm current-limiting resistors are being bypassed. A low resistance condition can be caused by touching a grounded object or by standing on a conductive surface.
- Red Worksurface LED (M)
This indicates that a high resistance condition (> 3.7 Megohms) exists across the conductive layer of the worksurface and/or the ground connections. Check the worksurface, ground cords and their connections for continuity. Note the audible alarm may also sound if enabled.
SCS 3057 STANDBY JACK
Since the activating switches are located in the SCS 732 and 733 Operator
Remotes, the normal operating procedure is for the operators to disconnect
their cords from the remotes when leaving the workstation.
However, an optional Standby Jack that allows the wrist cord to remain plugged
into the remotes is available.
Simply attach it to any convenient location then disconnect the cord from the
wristband and connect it to the Standby Jack. The green PASS LED on the 724
Workstation Monitor will illuminate upon connection. The yellow FAIL LOW LED
will slowly flash if the Standby Jack is grounded. It can be grounded by
attaching a ground wire to the screws or back plate. It can also be grounded
if the plate is attached to a grounded metal surface. The operator should
reconnect the wrist cord to their wristband upon returning to the workstation.
SCS 733 OPERATOR REMOTE
The SCS 733 Operator Remote is used to separate the two wrist strap jacks
featured on the 732 Dual Operator Remote. This provides a separation up to
approximately 10 feet away from the 724 Workstation Monitor. The 733 Operator
Remote is to be used in conjuction with the 732 Dual Operator Remote that is
supplied with the 724 Workstation Monitor.
See technical bulletin TB-9020 for installation instructions.
Calibration
Frequency of recalibration should be based on the critical nature of those ESD
sensitive items handled and the risk of failure for the ESD protective
equipment and materials. In general, SCS recommends that calibration
verification be performed annually.
Use the SCS 770065 Verification Tester to perform periodic testing of the 724
Workstation Monitor. The Verification Tester can be used on the shop floor
within a few minutes virtually eliminating downtime, verifying that the tester
is operating within tolerances.
See TB-9083 for more information.
Specifications
Default settings
Limited Warranty, Warranty Exclusions, Limit of Liability and RMA Request
Instructions
See the SCS Warranty –StaticControl.com/Limited-
Warranty.aspx
SCS – 926 JR Industrial Drive, Sanford, NC 27332
East: 919-718-0000 | West:
909-627-9634 • Website:
StaticControl.com
© 2022 DESCO INDUSTRIES INC
Employee Owned
References
- MENDA - 35660 Reztore® ESD Hand Lotion, Peach Scented, 8 oz, 12 Pack
- SCS - Static Control Solutions
- SCS - Limited Warranty and F.O.B. Point
- SCS - Limited Warranty and F.O.B. Point
- SCS - 2389 Interconnect Mat Cord, 10mm Studs, No Resistor, 10ft
- SCS - 3034
- SCS - 3050 SNAP 10MM FEMALE SOCKET, 8-PRONG, 10 PER PACK
- SCS - 2380D Mat Monitor Cord with Diode, 10mm Stud, 6ft
- SCS - 3057 Monitor Standby Jack
- SCS - 724-PSEU Adapter, 100-240 VAC In, 24VDC 0.25A Out, UK & Euro Plugs
- SCS - 724 Workstation Monitor, North America
- SCS - 724MO Workstation Monitor, No Power Adapter
- SCS - 724P Adapter, 120 VAC In, 25VDC 0.05A Out, N. America Plug
- SCS - 732 Dual Remote Wrist Strap Input Jack
- SCS - 733 Dual Conductor Remote, 724 Monitor Accessory
- SCS - 770037 Terminal Block for 724 Workstation Monitor, Pack of 5
- SCS - 770065 Verification Tester for 724 and 725 Monitors
- SCS - Dual-Wire Wrist Straps