INTRODUCTION

Our chillers are mainly divided into compressor refrigeration and electronic refrigeration, both of which are highly efficient cooling methods with it’s own advantage. At the same time, both use microcomputer control systems that can accurately control and display the actual water temperature in the fish tank.

Our aquarium chillers are widely used in aquariums and hydroponics to provide a high-quality, cool and comfortable living environment for your axolotl, fish, coral reef and crystal shrimps. This chillers can effectively control the water temperature between 74-80F, which is the most comfortable temperature for various aquatic creatures.
As for hydroponics, water chillers can keep the needed nutrient solution in the ideal temperature range which makes it’s vital to successful hydroponic grows. Our aquarium chillers make it easy to maintain the perfect temperature in your hydroponic system, which will help to ensure a fruitful and healthy harvest for you!

WARRANTY:

If you have any other questions, please feel free to contact us via Amazon email 🙂
Our shop provides one year after-sales service. If you encounter any problems during use, you can contact us freely.
And if you encounter a machine failure after Amazon’s 30-day return time, you can also contact us in time, and we will provide you with a satisfactory solution.

Web IconUS STORE: Boshi Electronic Instrument

Web IconEmail: [email protected]

Web Icon We’ll reply within 24 hours

PRECAUTIONS FOR SAFE USE

Please be sure to read the safety instructions carefully before using the chiller to prevent harm, damage to you and your aquatic creatures, and damage to the machine.

Caution

For 160L and 300L chillers, please note:

  1. In order to avoid the impact of shaking during transportation on the compressor inside the chiller, please let the chiller stand for 24 hours before using it after receiving the goods.
  2. Itis normal for the compressor inside the machine to shake slightly. Please do not shake the chiller itself.
  3. The compressor will start three minutes after the temperature setting is completed, please wait patiently.

For 50L chiller, please note:

Temperature probe must be placed in the water to ensure the chiller can detect and cool the water normally.

Dangerous

  1. Please be sure to unplug the electrical equipment used in the fish tank before putting your hands into the water while installing.
  2. Please unplug the power cord when lightning strikes.
  3. Do not use wet hands to plug or unplug the power cord, otherwise it will cause electric shock or injury.
  4. Please use the power socket separately, do not share the same socket with other high-power electrical appliances at the same time, so as to avoid excessive current and cause fire.
  5. When not in use for a long time, please unplug the power plug to prevent short circuit and spontaneous combustion caused by device aging, etc.
  6. The socket should be placed higher than the fish tank, and pay attention to s avoid letting water flow to the socket along the power cord. The plug and socket should not be soaked by water during use.
  7. hen in use, the plug must be inserted into the bottom of the socket and kept firmly, otherwise it will cause the component to overheat and burn out due to poor contact, leading to dangerous accidents such as short circuit or fire.
  8. Do not allow children to operate the chiller alone to avoid electric shock or injury.

Warning

  1. Do not place the chiller in the position of high temperature, no ventilation, direct sunlight, large lampblack and moisture.
  2. Do not block air vents or put objects near them.
  3. Do not insert metal shavings, iron wires, needles and other foreign objects into the chiller.
  4. Do not disassemble the chiller by yourself.

Pay attention to

  1. Do not turn the chiller upside down while using.
  2. You must hold the handle of the plug and do not pull the power cord when  unplugging the plug, otherwise the power cord may be easily damaged.
  3. Please unplug the power cord, hold the bottom of the chiller with both hands when handling, and be careful not to drop the machine.
  4. Do not place the chiller next to electrical products such as TVs, speakers, etc., so as not to interfere with the normal operation of the chiller.
  5. Do not put in a high temperature environment (room temperature above 96F/36C, fish tank bottom cabinet, sealed place, etc.) to avoid slow cooling or  malfunction of the chiller.

PARAMETERS

Model AL-160 1   AL-300 AL-60
Rated power AC110V AC110V AC110V
Power 1/10HP 1/3HP 200W
Suitable pump 600-1500L/H 320L/H
Water volume < 160L 5300L 560L
Pipe diameter 12mm inner diameter pipe 8mm inner diameter
Cooling method Built-in compresor cooling Electronic cooling
Refrigerant R134a No
Machine size 340200300mm 290290320mm 140310230mm
Machine weight 13kg 17kg 5kg
Accessories Pipe joints2, fixing nuts2, throat hoops*2,sealing
rings2, water pump1, water pipe*1 Throat hoops2,water pump1, pipe*1

Accessories for 160L/300L chillers

  • Output and input attachment
    Accessories

  • Fixing nut

  • Hose clamps

  • Flat sealing ring

INSTALLATION & TESTING

Water Pipe Installation

For 160/300L chiller,

  1. Install the output and input attachment pieces, there is no distinction, choose freely.

  2. Install the fixing nut, water pipe joint, flat sealing ring on the pipe joint, make sure they are tight.
    Installation Instruction

  3. Cut the 3m water pipe into two sections according to the length you need, use two hose clamps to tighten.

For 50L chiller,

  1. There is no distinction between water inlet and outlet.
  2. Provide a 2m pipe, you can cut it into two pieces, connect them to water inlet and water outlet on the back of the chiller as you like. Buy a long pipe if needed.

Note for 50L chiller: Temperature probe must be placed in the water to ensure the chiller can detect and cool the water normally.

Testing

Please test the chiller carefully before installation.

  1. Put the pump in the tub or a good size pan, put the output back in the tub or pan.
  2. Power up the unit and check for leaks. Let it run and make sure it cools properly.
  3. Once the chiller has no leaks and everything works, install it where you need it.
  4. Note that the “cool” is displaying during operation (the “cool” is notdisplayed in standby mode), and the chiller will starts to work after setting about 3 minutes.

Try the following methods if leakage:

  1. Check if the flat gasket sealing ring is put at the right place.
  2. Try to add some vacuum grease to the water pipe connection.
  3. Contact us if still have water leakage problem after trying.

Chiller & Pump Installation

For 160/300L chiller,
Installation Instruction

For 50L chiller,

  1. Water inlet and outlet are on the back of the chiller, no distinctions between them.
  2. Temperature probe must be placed in the water.
    Installation Instruction

TEMP SETTING & CORRECTION

Temperature Setting

Temperature Setting

For example, we need to set temperature range between 75-79F:

  1. Set target temperature
    Press the SET key, adjust to 75, and then press RST key to return.

  2. Set temperature difference
    Long press the SET key until the F1 code appears, and then press the SET, press up or down to adjust to 4. So, the chiller will start to running at 79F and stop running at 75F.

Temperature Correction

Long press the SET key until the F1 code appears, and then press the  to enter in F2 code (temperature correction function), the default is O. If there is an error between the displayed temperature and the actual water temperature, first confirm the error value.

Example:

  1. Aquarium water temperature is 85F, the display shows 83F
    Actual error: 85-83 =2
    Operation method: Enter the code F2, press the set key, and then press the
    “ ’ key to adjust to 2 degrees.
    Aquarium water temperature is 83F, display shows 85F
    Actual error: 83-85 = -2
    Operation method: Enter the code F2, press the set key, and then press the
    “ ” key to adjust to -2 degrees.

CLEANING & MAINTENANCE

  1. Before cleaning and maintenance, please confirm that the power plug has been unplugged.

  2. Please use a clean and soft cloth with good water absorptivity to wipe top cover, shell and other parts of the chiller to keep the appearance clean.
    (Note: please do not use a wet cloth to wipe the operating panel, plug and power cord)

  3. Do not use corrosive liquid medicine or hard objects to clean the product. (It is forbidden to use detergent, gasoline, banana water, hard brush, etc.)

  4. Water is strictly prohibited inside the chiller, please do not immerse the chiller in water for cleaning .

  5. Please clean the chiller regularly for 2-3 months to avoid affecting the cooling effect due to clogging of the chiller inside.

Methods of cleaning the chiller:

  1. A 2: 3 vinegar bath (2 parts 100% distilled vinegar to 3 parts water) is safe and effective at removing calcium deposits, salt creep, other hard minerals that build up in the chiller over time.
  2. You can also circulate the vinegar mix, rather than a bath soak, with the feed pump using a 5 gallon bucket as the reservoir.

TROUBLESHOOTING

Malfunction Possible Causes Solutions
Not working at all Not connect to the correct
voltage socket Connect the power plug to the correct voltage socket

The power supply voltage
is connected correctly| The compressor has a3 minute  working time
Water does not
circulate| Adjust the set button up
and down in a short time,
temperature circulationdevice stops working| Please confirm whether
the circulation device is
working properly
Air in the water pipe| There should be no air
accumulation in the water
pipe, especially the water
pump. Please keep all the
circuits full of water
Twisted water pipe| Strongly twisted water pipes will cause no water flow, please pay attention to the smooth adjustment
Poor output effect| The height of circulation device to the surface of the fish tank is too high| Please confirm the position
and lift of the circulating device.
Lift refers to the capacity
of the circulating device
The water pipe is dirty,
the dirt blocks the water pipe| Please clean the water pipe
regularly to keep it unblocked
Twisted water pipe| Please confirm that all the
water pipes of the circulation
device are kept smooth
Poor cooling
effect or inability
to cool
| The ambient temperature
is too high| The ambient temperature
should be kept below 35
degrees Celsius with good
ventilation
---|---|---
The chiller is placed in a
closed cabinet| Place the chiller on the
desktop or flat ground to
ensure a good ventilation
environment
The huge water volume of
the fish tank exceeds the
cooling capacity| Reduce the water volume
or replace with a more
powerful chiller
Bending of water pipes causes
the circulating insufficient| Be careful not to bend
the water pipe
Wet ground| Condensed water droplets flow out| Wipe the water droplets on
the surface of the fish tank
and the water pipe
Abnormal sound| There is air in the pipe| There should be no air
accumulation in the water
pipe, especially the water
pump, and keep all the
circuits full of water
Chiller prevents position tilt| Please put the chiller on
a level surface
Display error| —(Display 3 lines) water temperature probe is abnormal| Replace the temperature
probe
The difference between the
displayed temperature and
the actual temperature is
too large| Replace the temperature
probe
Water leakage| Incorrect connection The   is too thick
pipe|

  1. Check the flat gasket sealing ring
  2. Add some grease