EQUINOX EQLED358 Avalanche Snow Machine User Manual

June 14, 2024
EQUINOX

EQUINOX EQLED358 Avalanche Snow Machine User Manual
Avalanche Snow Machine

Safety advice

WARNING:
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!

Electric Shock IconCAUTION!
TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!
Please note that damages caused by user modifications to this equipment are not subject to warranty.

  • Before your initial start-up, please make sure that there is no damage caused during transportation.
  • Should there be any damage, consult your dealer and do not use the equipment.
  • To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual

IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

  • Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution!
  • Never remove warning or informative labels from the unit.
  • Do not open the equipment and do not modify the unit.
  • Do not switch the equipment on and off in short intervals,as this will reduce the system’s life.
  • Only use the equipment indoors.
  • Do not expose to flammable sources, liquids or gases.
  • Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable.
  • Make sure that the available mains supply voltage is 240V AC, 50Hz.
  • Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically.
  • If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again.
  • This unit is not intended for fixed installation
  • If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation),  do not connect power or switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature.
  • If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Prolight dealer for service.
  • Only use fuses of same type and rating.
  • Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS.
  • This fixture is for professional use only – it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls.
  • WARRANTY: One year from date of purchase.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.

Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and/or property. Before filling the unit disconnect the mains. Never fill with hot liquids.

Only use high quality, water based snow fluid recommended by the manufacturer. Other snow fluids may cause clogging and void the guarantee.

Always make sure there is sufficient snow fluid in the tank. Operating this snow machine without snow fluid will cause damage to the pump.

Operate the unit only after you have familiarised yourself with its functions. Do not permit operation by persons not qualified

for operating the unit and always drain the tank and use the original packaging if the unit is to be transported.

Product overview & technical specifications

Avalanche Snow Machine

Designed for large events, the Avalanche from Equinox utilises a large, high output fan to project the snow flakes up to 10 metres into the air. Adjustable output, controllable from either the supplied wired remote control or on board DMX. Supplied complete with custom designed flight case for protection during transportation. The robust steel chassis with built in tilt mechanism allows the user to direct the output as required.

  • Output volume: 150m3 per minute (full on)
  • Fluid consumption: 540ml/min at 100% (approx.)
  • Control: Wired remote control and DMX

Specifications

|
---|---
Power consumption| 1500W (max.)
Power supply| 240V, 50Hz
Unit dimensions| 830 x 470 x 820mm
Unit weight| 28.8kg
Flight case dimensions with wheels| 1010 x 880 x 520mm
Flight case dimensions without wheels| 890 x 880 x 520mm
Flight case weight| 30kg
Total weight| 58.8kg
Order code| EQLED358

Product Overview
Product Overview
Flightcase included
Product Overview
Handheld Remote Control included

Technical specifications

Dimension
Dimension

  1. – Fluid pipe and intake unit 02 – Bracket adjustment knobs
  2. Bracket
  3. – Power switch
  4. – 3-Pin XLR output
  5. – 3-Pin XLR inputRemote control socket
  6.  – Dipswitches
  7. Resettable fuse 15A 250V
  8. – PowerCON input

In the box:
1 x fixture, 1 x remote control, 1 x flightcase with wheels,
1 x powerCON cable
& 1 x user manual

Operating instructions

Operation:

Place the unit on a level surface.

Always disconnect it from the mains supply before filling as fluid could be spilled.

Always fill the tank away from the unit to prevent fluid getting inside the main housing.

If fluid should get inside the main housing, disconnect the unit from the mains immediately and consult a technician.

Installation

Install the unit in a well-ventilated area. Use in an insufficiently ventilated room can lead to the condensation of the snow fluid. The resulting slippery surface can cause accidents. Keep a minimum distance of 1m around the unit.

Furthermore do not orientate the output aperture directly in the direction of the audience’s eyes.

In order to create the best effect, there should be a distance between the unit and the audience of at least 5m.

Only install the snow machine on fire resistant, scratch resistant and water resistant surfaces.

This unit is constructed for a free standing installation only. The unit can be used whilst in the base of the flightcase with the lid removed. Make sure all brakes are applied to the flightcase and the unit.

The operator must always make sure that the safety-relating and machine- technical installations are approved by an expert before operation for the first time and after any further changes are made.

The operator has to make sure that the safety-relating and machine-technical installations are approved by a qualified person once a year.

Important

Please make sure you connect a substantial fluid source as 5 litres of fluid will only produce a maximum of 10 minutes full on snow output. Do not allow the fluid source to run dry.

To prevent the unit from overheating it is advised after 20 minutes on continuous operation you stop the unit outputting snow for approx. 10 minutes so the unit can cool down.

At the end of each operation water must be run through the pump to prevent seizure

Fire IconDANGER OF FIRE!
When installing the unit, make sure there is no highly flammable material (decoration articles etc) within a minimum distance of 1m

DANGER TO LIFE!
Disconnect from the mains before starting maintenance

Only use quality snow fluids recommended by your dealer. You must not use substances which are classified as ‘DANGEROUS WORKING MATERIALS’ or ‘FLAMMABLE FLUIDS

Cleaning and maintenance:

We recommend a frequent cleaning of the unit. Please use a soft lint-free and moistened cloth.

Never use alcohol or solvents!

The fluids we recommend are non-hazardous to the environment and can be disposed of via the sewage system.

There are no serviceable parts inside this unit.

Maintenance and service operations are only to be carried out by authorised dealers.

Breaker reset:

In the event of a power failure, please reset the 15A breaker located below the PowerCON input. If the breaker trips after it has been reset, this usually indicates a component fault. Disconnect the unit from the mains power supply and contact your local dealer for more information.

Should you need any spare parts, only use genuine parts.

If defective, please dispose of the unusable unit in accordance with the current legal regulations.

Should you have any further questions, please contact your dealer.

Operation

Connect the unit to a mains power supply via a powerCON cable. Then turn the power switch to ON, the red indication light on the power switch will illuminate.

For manual control simply connect the remote control provided and follow the remote control operation instructions below.

Remote control operation:

Remote control operation

  1. – Output volume
  2. – In use indicator
  3. – Power indicator
  4. – ON/OFF switch

Ensure the remote control switch is off and the output volume rotary knob is turned counter-clockwise until it stops.

Connect the handheld remote control to the main unit via the remote control socket. Once the remote is connected the red power indicator will illuminate.

Press the switch on the handheld remote control to ON, the green in use indicator will illuminate.

When you are ready to disperse snow, turn the output volume rotary knob clockwise to the desired output. To stop the dispersion of snow turn the output volume rotary knob counter-clockwise until it stops.

Care should be taken to ensure the fluid level is maintained and the unit is not allowed to run dry of fluid. Isolate from the mains supply before disconnecting or reconnecting the fluid source.

 DMX mode:

Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising, controlling or creating a show. DMX addressing is facilitated via the dipswitches on the top of the unit.

Addressing

Each device occupies 1 channel. To ensure that the control signals are properly directed to each device the fixture requires addressing. This needs to be changed for every fixture by changing the dipswitches as set out in the table below. The starting address is defined as the first channel from which the device will respond to the controller. Please make sure that you do not have any overlapping channels in order to control each fixture correctly and independently from any other fixture on the DMX data link. If two, three, or more devices are addressed similarly, they will work similarly.

Occupation of the dipswitches:

Dipswitch number 1 2 3 4 5 6 7 8 9
DMX starting address 1 2 4 8 16 32 64 128 256
Fixture 1 – Channel 1 ON
--- --- --- --- --- --- --- --- --- ---
OFF
Fixture 2 – Channel 2 ON
--- --- --- --- --- --- --- --- --- ---
OFF
Fixture 3 – Channel 3 ON
--- --- --- --- --- --- --- --- --- ---
OFF
Fixture 4 – Channel 4 ON
--- --- --- --- --- --- --- --- --- ---
OFF

Controlling
After having addressed all devices, you may now start operating these via your controller.

1 channel mode

Channel Value Function
CH1 000-255 Snow output (0-100%)

DMX dipswitch quick reference chart

DMX DIPSWITCH SET
0 = OFF
1 = ON| #9| 0| 0| 0| 0| 0| 0| 0| 0| 1| 1| 1| 1| 1| 1| 1| 1
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---

8| 0| 0| 0| 0| 1| 1| 1| 1| 0| 0| 0| 0| 1| 1| 1| 1

7| 0| 0| 1| 1| 0| 0| 1| 1| 0| 0| 1| 1| 0| 0| 1| 1

6| 0| 1| 0| 1| 0| 1| 0| 1| 0| 1| 0| 1| 0| 1| 0| 1

1| #2| #3| #4| #5|

0| 0| 0| 0| 0| | | 32| 64| 96| 128| 160| 192| 224| 256| 288| 320| 352| 384| 416| 448| 480
1| 0| 0| 0| 0| 1| 33| 65| 97| 129| 161| 193| 225| 257| 289| 321| 353| 385| 417| 449| 481
0| 1| 0| 0| 0| 2| 34| 66| 98| 130| 162| 194| 226| 258| 290| 322| 354| 386| 418| 450| 482
1| 1| 0| 0| 0| 3| 35| 67| 99| 131| 163| 195| 227| 259| 291| 323| 355| 387| 419| 451| 483
0| 0| 1| 0| 0| 4| 36| 68| 100| 132| 164| 196| 228| 260| 292| 324| 356| 388| 420| 452| 484
1| 0| 1| 0| 0| 5| 37| 69| 101| 133| 165| 197| 229| 261| 293| 325| 357| 389| 421| 453| 485
0| 1| 1| 0| 0| 6| 38| 70| 102| 134| 166| 198| 230| 262| 294| 326| 358| 390| 422| 454| 486
1| 1| 1| 0| 0| 7| 39| 71| 103| 135| 167| 199| 231| 263| 295| 327| 359| 391| 423| 455| 487
0| 0| 0| 1| 0| 8| 40| 72| 104| 136| 168| 200| 232| 264| 296| 328| 360| 392| 424| 456| 488
1| 0| 0| 1| 0| 9| 41| 73| 105| 137| 169| 201| 233| 265| 297| 329| 361| 393| 425| 457| 489
0| 1| 0| 1| 0| 10| 42| 74| 106| 138| 170| 202| 234| 266| 298| 330| 362| 394| 426| 458| 490
1| 1| 0| 1| 0| 11| 43| 75| 107| 139| 171| 203| 235| 267| 299| 331| 363| 395| 427| 459| 491
0| 0| 1| 1| 0| 12| 44| 76| 108| 140| 172| 204| 236| 268| 300| 332| 364| 396| 428| 460| 492
1| 0| 1| 1| 0| 13| 45| 77| 109| 141| 173| 205| 237| 269| 301| 333| 365| 397| 429| 461| 493
0| 1| 1| 1| 0| 14| 46| 78| 110| 142| 174| 206| 238| 270| 302| 334| 366| 398| 430| 462| 494
1| 1| 1| 1| 0| 15| 47| 79| 111| 143| 175| 207| 239| 271| 303| 335| 367| 399| 431| 463| 495
0| 0| 0| 0| 1| 16| 48| 80| 112| 144| 176| 208| 240| 272| 304| 336| 368| 400| 432| 464| 496
1| 0| 0| 0| 1| 17| 49| 81| 113| 145| 177| 209| 241| 273| 305| 337| 369| 401| 433| 465| 497
0| 1| 0| 0| 1| 18| 50| 82| 114| 146| 178| 210| 242| 274| 306| 338| 370| 402| 434| 466| 498
1| 1| 0| 0| 1| 19| 51| 83| 115| 147| 179| 211| 243| 275| 307| 339| 371| 403| 435| 467| 499
0| 0| 1| 0| 1| 20| 52| 84| 116| 148| 180| 212| 244| 276| 308| 340| 372| 404| 436| 468| 500
1| 0| 1| 0| 1| 21| 53| 85| 117| 149| 181| 213| 245| 277| 309| 341| 373| 405| 437| 469| 501
0| 1| 1| 0| 1| 22| 54| 86| 118| 150| 182| 214| 246| 278| 310| 342| 374| 406| 438| 470| 502
1| 1| 1| 0| 1| 23| 55| 87| 119| 151| 183| 215| 247| 279| 311| 343| 375| 407| 439| 471| 503
0| 0| 0| 1| 1| 24| 56| 88| 120| 152| 184| 216| 248| 280| 312| 344| 376| 408| 440| 472| 504
1| 0| 0| 1| 1| 25| 57| 89| 121| 153| 185| 217| 249| 281| 313| 345| 377| 409| 441| 473| 505
0| 1| 0| 1| 1| 26| 58| 90| 122| 154| 186| 218| 250| 282| 314| 346| 378| 410| 442| 474| 506
1| 1| 0| 1| 1| 27| 59| 91| 123| 155| 187| 219| 251| 283| 315| 347| 379| 411| 443| 475| 507
0| 0| 1| 1| 1| 28| 60| 92| 124| 156| 188| 220| 252| 284| 316| 348| 380| 412| 444| 476| 508
1| 0| 1| 1| 1| 29| 61| 93| 125| 157| 189| 221| 253| 285| 317| 349| 381| 413| 445| 477| 509
0| 1| 1| 1| 1| 30| 62| 94| 126| 158| 190| 222| 254| 286| 318| 350| 382| 414| 446| 478| 510
1| 1| 1| 1| 1| 31| 63| 95| 127| 159| 191| 223| 255| 287| 319| 351| 383| 415| 447| 479| 511

DMX setup

Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” from 1- 511. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the chain starts at 107.

DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:
DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant.

To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the

DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in

a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a

DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output, see image below.

Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers.
Please quote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m
Cable
Note: DMX cable must be daisy chained and cannot be split.

Notice
Be sure to follow the diagrams below when making your own cables. Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour.

common
Connection
DMX-512 out 3-pin XLR
DMX-512 in 3-pin XLR
Connection

XLR Pin Configuration

Pin 1 = Ground
Pin 2 = Negative
Pin 3 = Postive

Special note:

Line termination:
When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour.

Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin – Order ref: CABL90, 5-pin – Order ref: CABL89)

Termination reduces signal transmission problems and interference. It is always advisable to connect a DMX terminal, (resistance 120 Ohm 1/4 W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture.

5-pin XLR DMX connectors:

Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.

5-pin XLR (female)
Pin 1 : GND (screen)
Pin 2 : Signal (-)
Pin 3: Signal (+)
Pin 4 : N/C
Pin 5 : N/C
Connection
3-pin XLR (male)
Pin 1 : GND (screen)
Pin 2: Signal (-)
Pin 3 : Signal (+)

3-pin XLR (female)
Pin 1 : GND (screen)
Pin 2 : Signal (-)
Pin 3 : Signal (+)
Connection
5-pin XLR (male)
Pin 1 : GND (screen)
Pin 2 : Signal (-)
Pin 3: Signal (+)
Pin 4 : N/C
Pin 5 : N/C

WEEE notice

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling.

Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EQUINOX User Manuals

Related Manuals