EQUINOX EQLED008B FUSION SPOT MKIII Moving Head Camera User Manual

June 13, 2024
EQUINOX

EQUINOX-LOGO

EQUINOX EQLED008B FUSION SPOT MKIII Moving Head Camera

EQUINOX-EQLED008B-FUSION-SPOT-MKIII-Moving-Head-Camera-
PRODUCT

Product Information:

EQUINOX FUSION SPOT MKIII

The EQUINOX FUSION SPOT MKIII is a compact and lightweight lighting fixture designed for indoor use only. It features various control modes including sound active, auto, master/slave, and DMX-512 modes. The fixture offers 7 gobos + open and 7 colors + open options. It also includes electronic dimming functionality ranging from 0 to 100%. The unit operates on a specific voltage and requires proper grounding for safety.

Technical Specifications:

  • Control: Sound active, Auto, Master/slave, and DMX-512
    modes

  • DMX Channels: 1CH/8CH/10CH

  • Gobos: 7 Gobos + open

  • Colors: 7 Colors + Open

  • Electronic dimming: 0-100%

  • Voltage: [Specify voltage]

  • Fuse: [Specify fuse information]

  • Power consumption: [Specify power consumption]

  • Light source: [Specify light source]

  • Dimension: [Specify dimensions]

  • Weight: [Specify weight]

  • Pan/Tilt: [Specify pan/tilt information]

  • Power sockets: [Specify power socket details]

  • XLR sockets: [Specify XLR socket details]

Product Usage Instructions

Safety Instructions

Before using the EQUINOX FUSION SPOT MKIII, please read and follow the safety instructions provided in the user manual. These instructions include important information about installation, usage, and maintenance.

It’s essential to keep the user guide for future reference. If you sell or transfer the unit to another user, make sure they receive this user guide as well. Before operating the unit, carefully check for any transportation damage.

Ensure that the voltage and frequency of the power supply match the power requirements of the unit. Ground the yellow/green conductor to earth to prevent electric shock. The unit should only be used indoors in a dry location with adequate ventilation.

During operation, avoid touching any power cables as high voltage may cause electric shock. To prevent electrical shock or fire, do not expose the unit to rain or moisture. Wait at least five minutes after switching off before opening the unit. Replace the housing and lenses if visibly damaged.

Features & Technical Specifications

The EQUINOX FUSION SPOT MKIII offers several features and technical specifications:

  • Control: Sound active, Auto, Master/slave, and DMX-512 modes
  • DMX Channels: 1CH/8CH/10CH
  • Gobos: 7 Gobos + open
  • Colors: 7 Colors + Open
  • Electronic dimming: 0-100%
  • Compact size and light-weight
  • Voltage: [Specify voltage]
  • Fuse: [Specify fuse information]
  • Power consumption: [Specify power consumption]
  • Light source: [Specify light source]
  • Dimension: [Specify dimensions]
  • Weight: [Specify weight]
  • Pan/Tilt: [Specify pan/tilt information]
  • Power sockets: [Specify power socket details]
  • XLR sockets: [Specify XLR socket details]

How To Set The Unit – Control Panel

The EQUINOX FUSION SPOT MKIII features a control panel with various buttons and functions. Follow the instructions below to set up the unit:

DMX Address Setting

To set the DMX address:

  1. Press the MENU button to select “ADDR”.
  2. Press the ENTER button, and the display will blink.
  3. Use the DOWN and UP buttons to choose the desired address.
  4. Press the ENTER button to confirm the address selection.
  5. To go back to the main menu without any changes, press the MENU button again.
  6. To return to the main menu after one second or wait for one minute, press and hold the MENU button.

Channel Mode Selection

To select the channel mode:

  1. Press the MENU button to select “CHND”.
  2. Press the ENTER button, and the display will blink.
  3. Use the DOWN and UP buttons to select the desired channel mode – (1 Channel), (8 Channel), or (10 Channel).
  4. Press the ENTER button to confirm the channel mode.
  5. To go back to the main menu without any changes, press the MENU button again.
  6. To return to the main menu after one second or wait for one minute, press and hold the MENU button.

Master Mode or Slave Mode Selection

To select the master mode or slave mode:

  1. Press the MENU button to select “MAST”.
  2. Press the ENTER button, and the display will blink.
  3. Use the DOWN and UP buttons to select the desired mode – Master Mode or Slave Mode.
  4. Press the ENTER button to confirm the selected mode.
  5. To go back to the main menu without any changes, press the MENU button again.
  6. To return to the main menu after one second or wait for one minute, press and hold the MENU button.

Please refer to the user manual for additional functions and settings of the EQUINOX FUSION SPOT MKIII.

Safety Instruction

Please read the instructions carefully as they include important information about installation, usage and maintenance.

WARNING

Please keep this User Guide for future consultation. If you sell the unit to another user be sure that they also receive this.
Unpack and check carefully that there is no transportation damage before using the unit.

  • Before operating, ensure that the voltage and frequency of the power supply match the power requirements of the unit.

  • It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.

  • The unit is for indoor use only. Use only in a dry location.

  • The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.

  • Disconnect the mains power before replacement or servicing.

  • Make sure there are no flammable materials close to the unit while operating as they may cause a fire hazard.

  • Always use a safety cable when installing this unit. Do not carry the unit with its head only, always carry it using the base.

  • The maximum ambient temperature is: 40℃. Don’t operate it where the temperature is higher than this.

  • In the event of a serious operating problem stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.

  • Do not touch any power cables during operation as the high voltage may cause an electric shock.
    Warning

  • To prevent or reduce the risk of electrical shock or fire, do not expose maintenance. the unit to rain or moisture.

  • Do not open the unit within five minutes after switching off.

  • The housing and lenses must be replaced if they are visibly damaged.

Installation

The unit should be mounted via its screw holes onto the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Make sure that the structure to which you are attaching the unit to is secure and is able to support a weight of 10 times of the unit’s weight. Always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture.
The equipment must be installed by professionals and it must be installed in a place where is out of the reach of people and no one can pass by or under it.

Features & Technical Specifications

  • Control: Sound active, Auto, Master/slave and DMX-512 modes
  • DMX Channels: 1CH/8CH/10CH
  • Gobos: 7 Gobos + open
  • Colors: 7 Colors + Open
  • Electronic dimming: 0-100%
  • Compact size and light-weight
    • Voltage: 100V~240V, 50/60Hz
    • Fuse: T 2.5A
    • Power consumption: 41W
    • Light source: 1 x 12W white LED
    • Dimension: 159 x 147 x 265mm
    • Weight: 2.5 kg
    • Pan/Tilt: 540°/190°
    • Power sockets: IEC IN
    • XLR sockets: 3-pin XLR IN/OUT

How To Set The Unit

1 Control panel

Display
Shows the various menus and selected functions

Button

MENU Selects the programming functions
DOWN To go backward in the selected functions
UP To go forward in the selected functions
ENTER Confirms the selected functions

Mains input
Connection to the power supply.

DMX input/output
For DMX 512 linking. Use a 3-pin XLR cables to link to the controller or to other units.

Main Functions

To select any of the given functions, press the MENU button up to where the required function is showing on the display. Select the function by pressing the ENTER button and the display will blink. Use the DOWN and UP buttons to change the mode. Once the required mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes, press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

The main functions are as below:









Menu

| ADDR| 001-512
---|---|---
CHND| 1CH/8CH/10CH


SLMD

| MAST
SL1
SL2



SHND

| SH1
SH2
SH3
SH4


SOUN

| ON
OFF
SENS| 000-100


LED

| ON
OFF
DISP→INVERT
|

PAN INVERT

| YES
---|---|---
NO

TILT INVERT

| YES
NO
TEST| Self-Test
VER| Software Version
RSET| RSET

DMx Address Setting
Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to choose the address to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Channel Mode
Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to select the (1 Channel) mode, (8 Channel) mode or (10 Channel) mode.
Once the mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Master Mode or Slave Mode
Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to select the (Slave 1), (Slave 2) or (Master) mode. Once the mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Show Mode
Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to select the (show 1) or (show 2) or (show 3) or (show 4) mode. Once the mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Sound Mode
Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to select the (sound on) or (sound off) mode. Once the mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Sound Sensitivity
Press the MENU and use the UP and DOWN buttons to select and select the sound sensitivity between value 0 and 100. Press the ENTER button for confirmation after value selection. To go back to the functions without any changes press the MENU button again.

Led Display
Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to select the (Led display on) or (Led display off) mode. Once the mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Display Inversion
Press the MENU button to select . Press the ENTER button to change the mode d5 IP (display normal), it will be automatically saved after 8 seconds. Press the ENTER button again to select the mode (display inversion). To go back to the functions press the MENU button. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.
. Display normal mode is for floor standing the unit.
Display inversion mode is for hanging the unit upside down.

Pan Inversion
Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to select the (normal) or (pan inversion) mode. Once the mode has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Tilt Inversion
Press the MENU button to select . Press the ENTER button and the display will blink. Use the DOWN and UP buttons to select the .
(normal) or (tilt inversion) mode. Once the mode has been selected, press the ENTER button to confirm. To go back to the functions without any change press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Auto-Test
Press the MENU button to select . Press the ENTER button and the unit will run a self-test with its built-in programs. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button for one second or wait for one minute to go back to the main menu.

Software version
Press the MENU button up to when the . is blinking on the display.
Pressing ENTER button and the display will show the version of software of the unit. To go back to the functions press the MENU button.

Reset
Press the MENU button to select . Press the ENTER button and all channels of the unit will return to their standard position.

How To Control The Unit

  1. Master/slave built-in preprogram function
  2. Universal DMX controller

There is no need to turn the unit off when you change the DMX address as new DMX address setting will take effect at once. Every time you turn the unit on, it will show “ “on the display and move all the motors to their ‘home’ position and you may hear some noises for about 20 seconds.
After that the unit will be ready to receive a DMX signal or run the built in programs.

Master/Slave Built In Preprogrammed Function
By linking the units in master/slave connection, the first unit will control the other units to give an automatic, sound activated, synchronized light show. This function is good when you want an instant show. You have to set the first unit as master and select show 1, show 2, show 3 or show 4 from the Show Mode. The other unigts must be set to either Slave 1 (normal) or Slave 2 (2 light show) mode. A DMX cable between the units for daisy chaining is needed.
2-light show
In slave mode, Slave 1 means the unit works normally and Slave 2 means 2-light show. In order to create a great light show, you can set Slave 2 on the second unit to get a random mirror image of master unit includes pan and tilt inversion.

DMX Controller
By using a universal DMX controller to control the units, you will need to set a DMX address from 1 to 512 so that the units can receive a DMX signal. Press the MENU button until , is showing on the display.
Press the ENTER button and the display will blink. Use the DOWN and UP buttons to change the DMX-512 address. Once the address has been selected, press the ENTER button to confirm. To go back to the functions without any changes press the MENU button again. Press and hold the MENU button one second or wait for one minute to go back to the main menu.

Please refer to the below diagram to address your first 4 units :

Channel

mode

| Unit 1

Address

| Unit 2

Address

| Unit 3

Address

| Unit 4

Address

---|---|---|---|---
1 channel| 1| 2| 3| 4
8 channel| 1| 9| 17| 25
10 channel| 1| 11| 21| 31

DMX 512 Configuration

1 CHANNEL MODE

Channel Function Value




1

| Random shows| 248-255
Show 4| 188-247
Show 3| 128-187
Show 2| 068-127
Show 1| 008-067
Blackout| 000-007

8 CHANNEL MODE

Channel Function Value Percent / Setting
1 Pan 000-255 Pan 0°~ 540°
2 Tilt 000-255 Tilt 0°~ 190°
000-007 White
008-014 Light Blue
015-021 Pink
022-028 Orange
029-035 Green
3 Colour 036-042

043-049

| Blue Yellow
| | 050-056| Red
| | 057-127| Split colors
| | 128-189| Color Scroll Fast to Slow
| | 190-193| Stop
| | 194-255| Color Scroll Slow to Fast
| | 000-007| Gobo 1 (Open)
---|---|---|---
| | 008-015| Gobo 2
| | 016-023| Gobo 3
| | 024-031| Gobo 4
| | 032-039| Gobo 5
| | 040-047| Gobo 6
| | 048-055| Gobo 7
| | 056-063| Gobo 8
| | 064-071| Gobo 1 Shake
| | 072-079| Gobo 2 Shake
| | 080-087| Gobo 3 Shake
4| Gobo| 088-095

096-103

| Gobo 4 Shake

Gobo 5 Shake

| | 104-111| Gobo 6 Shake
| | 112-119| Gobo 7 Shake
| | 120-127| Gobo 8 Shake
| | 128-189| Gobo Scroll, Fast to Slow
| | 190-193| Stop
| | 194-255| Gobo Scroll , Slow to Fast
| | 120-127| Gobo 8 Shake
| | 128-189| Gobo Scroll, Fast to Slow
| | 190-193| Stop
| | 194-255| Gobo Scroll , Slow to Fast
| | 000-007| Close
| | 008-015| Open
| | 016-131| Strobe Slow->Fast
| | 132-139| Open
5| Shutter| 140-181

182-189

| Fast Close Slow Open Open
| | 190-231| Fast Open Slow Close
| | 232-239| Open
| | 240-247| Random Strobe
| | 248-255| Open
6| Pan/Tilt Speed| 000-255| Fast -> Slow
| | 000-069| Null
---|---|---|---
| | 070-079| Blackout while Pan/Tilt Move
| | 080-089| Null
| | 090-099| Blackout when Color changes
7| Function| 100-109

110-119

| Null

Blackout when Gobo changes

| | 120-199| Null
| | 200-209| Reset All
| | 210-249| Null
| | 250-255| Sound Active
8| Dimmer| 000-255| 0~100%

10 CHANNEL MODE

Channel Function Value Percent / Setting
1 Pan1 000 – 255 Pan 0°~ 540°
2 Pan Fine 000 – 255 0~100%
3 Tilt 000-255 Tilt 0°~ 190°
4 Tilt Fine 000-255 0~100%
000-007 White
5 Colour 008-014

015-021

| Light Blue Pink
| | 022-028| Orange
---|---|---|---
029-035| Green
036-042| Blue
043-049| Yellow
050-056| Red
057-127| Split colors
128-189| Color Scroll Fast to Slow
190-193| Stop
194-255| Color Scroll Slow to Fast
| | 000-007| Gobo 1 (Open)
| | 008-015| Gobo 2
| | 016-023| Gobo 3
| | 024-031| Gobo 4
| | 032-039| Gobo 5
| | 040-047| Gobo 6
| | 048-055| Gobo 7
| | 056-063| Gobo 8
| | 064-071| Gobo 1 Shake
6| Gobo| 072-079| Gobo 2 Shake
| | 080-087| Gobo 3 Shake
| | 088-095| Gobo 4 Shake
| | 096-103| Gobo 5 Shake
| | 104-111| Gobo 6 Shake
| | 112-119| Gobo 7 Shake
| | 120-127| Gobo 8 Shake
| | 128-189| Gobo Scroll, Fast to Slow
| | 190-193| Stop
| | 194-255| Gobo Scroll , Slow to Fast
| | 000-007| Close
| | 008-015| Open
| | 016-131| Strobe Slow->Fast
| | 132-139| Open
7| Shutter| 140-181

182-189

| Fast Close Slow Open Open
| | 190-231| Fast Open Slow Close
| | 232-239| Open
| | 240-247| Random Strobe
| | 248-255| Open
8| Pan/Tilt Speed| 000-255| Fast -> Slow
| | 000-069| Null
9| Function| 070-079

080-089

| Blackout while Pan/Tilt Move Null
| | 090-099| Blackout when Color changes
| | 100-109| Null
---|---|---|---
110-119| Blackout when Gobo changes
120-199| Null
200-209| Reset All
210-249| Null
250-255| Sound Active
10| Dimmer| 000-255| 0~100%

Troubleshooting

Following are a few common problems that may occur during operation and some suggestions for easy troubleshooting:

  • The unit does not work, no light and the fan does not work
    1. Check the connection of the power and the main fuse.
  • Not responding to DMX controller
    1. DMX LED should be on. If not, check DMX cables to see if linked correctly.
    2. If the DMX address is showing but no response to the controller, check the address settings and DMX polarity.
    3. Try another DMX controller.
  • No response to the sound
    1. Make sure the unit is not receiving a DMX signal.
    2. Check the microphone to see if it is good by tapping it. The microphone is located on the bottom plate of the unit.

Fixture Cleaning

The cleaning of external optical lenses must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause a greater accumulation of dirt on the unit’s optics.
Clean with a soft cloth using normal glass cleaning fluid or mild soapy water.

  • Always dry the parts carefully.
  • Clean the external optics at least every 20 days.

www.prolight.co.uk

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals