LifeSafety Power ADC-AC-X1100-2PSE Intelligent Door Controller User Guide
- June 14, 2024
- LifeSafety Power
Table of Contents
QUICK GUIDE ADC-AC-X1100-2PSE
090920_rev1
User Guide
Description
The ADC-AC-X1100-2PSE is a two door access control unit featuring dual voltage power and includes one prewired X1100. The 14”x 12”x 4.5” metal enclosure includes battery space.
Equipment List
- Pre installed AC power cord
- Power Supply 24VDC / 3A (model: FPV4)
- Secondary 12V supply (model: B100)
- Pre-installed X1100 controller
Accessories included
- AC power cord
- Battery harness
System Operation
The FPV4 power supply converts AC primary power to 24VDC for charging the
battery set and powering the X1100 controller, B100, locking device(s), and
24V auxiliary devices. The B100 is powered from the FPV4 Auxiliary terminals
and steps the 24V down to 12V to power any 12V auxiliary devices.
The battery set is charged by the red/black harness on the bottom edge of the
FPV4. The battery set MUST be two 12V batteries in series for a 24V battery
set. Observe polarity or damage to the system will occur.
Positive lock power is prewired to the X1100 lock relay Common terminals. The
lock positive should be wired to the NC (Fail Safe) or NO (Fail Secure)
terminal as appropriate. Each lock negative should be wired directly to the
FPV (-) terminal to minimize noise and surges in the system.
Terminal Output Ratings
**Max currents listed are for individual terminals – total current at 12V and 24V not to exceed max rating of supply
Board| Terminal| Voltage| Max Current**| Notes
FPV4| DC OUT| 24V| 1.5A| Output can be switched by FAI Input on FPV4
AUX OUT| 24V| 0.75A| Max Current includes current drawn by 8100
B100| DC OUT| 12V| 1.5A| For additional 12V devices
J2 (DC OUT)| 12V| 1.5A| For additional 12V devices
J5 (DC OUT)| 12V| 1.5A| For additional 12V devices
J1 (DC IN)| 24V| 0.75A| For additional 24V devices
J4 (DC IN)| 24V| 0.75A| For additional 24V devices
X1100| OUT1 (NO or NC)| 24V| 1.5A| Switched Lock Output – Ground at FPV4 (-)
Terminal
OUTS (NO or NC| 24V| 1.5A| Switched Lock Output – Ground at FPV4 (-) Terminal
ADC-AC-X1100-2PSE QUICK GUIDE
Wiring Diagram
September 2020
Read User Manual Online (PDF format)