WEISER 68533 Universal Better Than Wax Toilet Seal User Guide
- June 14, 2024
- Weiser
Table of Contents
- 68533 Universal Better Than Wax Toilet Seal
- Prts In The Box
- Prepare the door and check dimensions
- Install the latch and strike
- Install the exterior keypad, spindle, and interior assembly
- Install levers
- Test latch operation
- Install battery
- Add user codes
- OPTIONAL: Enable / Disable Programming Code
- Test the lock and review lock functionality
- Additional Programming Features
- Troubleshooting
- Important Safeguards
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SMART CODE™ 10
COMMERCIAL GRADE LEVER
Installation and User Guide
68533 Universal Better Than Wax Toilet Seal
Required tools
Ruler | Phillips head screwdriver |
---|---|
Additional Tools (depending on application)
Hammer | Wood block | Flathead screwdriver |
---|---|---|
Weiser
1-800-501-9471
wwwweiserlock.com
Prts In The Box
Prepare the door and check dimensions
If drilling a new door, use the supplied template and the complete door
drilling instructions available at
www.weiserlock.com/doorprep.
A. Measure to confirm that the hole in the door is 2-1/8″ (54 mm).
*If you are installing this lever below an existing lock or you plan to installa lock above this lever, make sure that the distance between holes is at least 6-1/2″ (165 mm).
B. Measure to confirm that the backset is either 2-3/8″ or 2-3/4″ (60 or 70
mm).
C. Measure to confirm that the hole in the door edge is 1″ (25 mm).
D. Measure to confirm that the door is between 1-3/8″ and 1-3/4° (35 mm and 44 mm) thick.
Install the latch and strike
A. Hold the latch in front of the door hole, with the latch face flush against the door edge.
B. Are the latch holes centered in the door hole?
C. Is the door edge chiseled?
D. Install strike on the door frame.
Install the exterior keypad, spindle, and interior assembly
A. Install exterior keypad.
B. Install spindle.
C. OPTIONAL: Install security set screw.
For commercial use: Installing the security set screw will lock the interior
cover and prevent easy access to the battery and reset button.
Interior assembly
D. Connect and secure cable to interior assembly.
E. Install interior assembly and secure with mounting screws.
Install levers
A. Install exterior lever.
B. Insert key and turn 90° clockwise.
C. Secure exterior lever.
D. Install interior lever.
E. Secure interior lever.
Test latch operation
Close door, test latch operation and make adjustments as needed:
The small bolt of the latch should not enter the strike hole. If it enters the
strike hole, reposition strike.
If latch is loose in the strike, adjust the strike tab so it grips the latch boit better when the door is closed.
Install battery
A. Remove interior cover.
If you installed the security screw in step 3C, you will need to remove it to
install the battery.
B. Connect 9V battery.
C. Secure battery into interior assembly.
D. Reinstall battery cover.
Add user codes
Move swiftly during programming. If no digit is pressed for 10 seconds, the
system will time out and you will need to restart the procedure.
A. Make sure the door is open.
Press and release the Program button using the SmartKey™ tool or a paper clip.
You will hear two beeps.
B. Press 1. You will hear one short beep and the keypad will flash green once.
C. Press Weiser.
D. Enter a User Code. It must be between 4 and 8 digits.
For security reasons, the first 4 digits of each user code must be unique. For
example, you are unable to programa user code 1-2-3-4-5 as well asa user code
1-2-3-4-6.
E. Press Weiser.
F. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step A.
OPTIONAL: Enable / Disable Programming Code
Please note that once a Programming Code is enabled, the Program button is
disabled.
A. A Programming Code enables you to make changes without needing to access
the Program button. This is ideal for landlords to allow programming from the
outside, without access to the interior Program button.
Please note that once a Programming Code is enabled, the Program button is
disabled and can be used only to factory reset the lock.
B. Make sure the door is open. Press and release the Program button using the
SmartKey™ tool or a paper clip. You will hear two beeps.
C. Press 3. You will hear one short beep and the keypad will flash green.
D. Press Weiser.
E. Enter a Programming Code. It must be between 4 and 8 digits.
The Programming Code cannot be the same as any user code.
F. Press Weiser.
G. Re-enter Programming Code.
H. Press Weiser. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad fiashes red, it was unsuccessful. Repeat from step A.
Test the lock and review lock functionality
Unlocking the Door with a User Code
Confirm that the code(s) added in previous step can unlock the door.
Enter user code.
The tock will beep twice to indicate that it unlocked.
Tip: You can press the Weiser button before entering your user code to
light up the keypad at night.
Unlocking the Door with a Key
a. To unlock using a key, turn the key clockwise to the horizontal position
then turn the lever to open the door.
b. To remove the key, turn the key back to the vertical position.
Turnpiece Functions – Choosing a Mode
Auto-lock mode
Key or code is needed for entry from the outside.
OR
Passage mode
Stays unlocked, allowing entry without a key or code.
Emergency Egress
The Interior lever of this lock will always open the door when turned,
regardless of whether it is locked or unlocked. This Is to allow for a safe
and easy exit in case of emergency.
Re-key the lock (if needed)
- IMPORTANT: Remove lever before re-keying.
- Re-key the lock to work with your existing key. See the supplied SmartKey™ Re-key instructions for more information.
Reference Guide
GED2600 at a Glance
System Signals
Use Cases | Sound | Light |
---|---|---|
Correct user code entered to unlock door | 2 short beeps | 2 short green flashes |
Lock auto-locks | 1 long beep | 1 long red flash |
Turnpiece rotated to unlock position | 2 short beeps | None |
Turnpiece rotated to locked position | 1 long beep | None |
Low battery alarm | 10 short beeps | 10 short red flashes |
3 incorrect user codes entered | 15 long beeps | 15 long red flashes |
Entering factory reset mode after Program button is pressed and held for 30
seconds.| 1 long beep| None
Entering programming mode after pressing and releasing Program button| 2
beeps| None
Successful programming| 1 long beep| 1 long green flash
Unsuccessful programming| 3 short beeps| 3 short red flashes
Additional Programming Features
How to add permanent or one-time User Codes
- Make sure the door is open.
- If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps. If you have enabled a Programming Code, enter your Programming Code, then press Weiser. You will hear one short beep and the keypad will flash green.
- Press 1 to add a permanent user code that can be used for entry at all times, until deleted. Press 7 to add a one-time user code. A one-time user code may be used only once, which wili be deleted immediately after use (typically used in emergency cases when you need to give one-time access to a person). You will hear one short beep and the keypad will flash green.
- Press Weiser.
- Enter anew User Code. It must be between 4 and 8 digits. For security reasons, the first 4 digits of each user code must be unique. For example, you are unable to program a user code 4-8-1-5-1 as well as a user code 4-8-1-5-2.
- Press Weiser. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step 1.
How to enable/disable User Codes
If User Codes are disabled (example: when you go on vacation), the lock can
only be operated by the key.
- Make sure the door is open.
- If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps. If you have enabled a Programming Code, enter your Programming Code, then press Weiser. You will hear one short beep and the keypad will flash green.
- Press 6. You will hear one short beep and the keypad will flash green.
- Press Weiser. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step 1.
How to mute/unmute lock
If the lock is muted, you will not hear beeping during programming, normal
operation, or system signals.
You will still get a low battery alarm.
- Make sure the door is open.
- If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps. If you have enabled a Programming Code, enter your Programming Code, then press Weiser. You will hear one short beep and the keypad will flash green.
- Press 5. You will hear one short beep and the keypad will flash green.
- Press Weiser. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step 1.
How to delete individual User Codes
-
Make sure the door is open.
-
If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps.
If you have enabled a programed Code, enter your Programming Code, then press Weiser. You will hear one short beep and the keypad will flash green. -
Press 2 to delete a user code.
You will hear one short beep and the keypad will flash green. -
Press Weiser.
-
Enter the User Code you wish to delete.
Press Weiser. -
Enter the User Code Again.
-
Press Weiser . You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step 1.
How to delete all User Codes
-
Make sure the door is open.
-
If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps.
If you have enabled a Programming Code, enter your Programming Code, then press Weiser. You will hear one short beep and the keypad will flash green. -
Press 4. You will hear one short beep and the keypad will flash green.
-
Press Weiser.
-
Enter 9-9-9-9-9-9.
-
Press Weiser.
-
Enter 9-9-9-9-9-9.
-
Press Weiser . You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step 1.
How to change the auto-locking duration
-
Make sure the door is open.
If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps.
If you have enabled a Progra We Code, enter your Programming Code, then press Weiser. You will hear one short beep and the keypad will flash green. -
Press 8. You will hear one short beep and the keypad wiil flash green.
-
Press Weiser.
-
Enter delay time between 1-99 seconds.
-
Press Weiser. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step 1.
How to enable/disable turnpiece functionality
A feature for property managers
If the turnpiece is disabled, the lock will always auto-lock after each entry.
The turnpiece will rotate but will not activate passage mode. User code or key
will always be required for entry.
-
Make sure the door is open.
-
If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps.
If you have enabled a Programe] Code, enter your Programming Code, then press Weiser. You will hear one short beep and the keypad will flash green. -
Press 9. You will hear one long beep and the keypad will flash green.
-
Press Weiser. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step 1.
Factory Reset
A factory reset will delete all codes associated with the lock.
- Make sure the door is open and unlocked.
- Press and hold the Program button for 30 seconds using the SmartKey™ tool ora paper clip. You will hear one long beep.
- Press and release the Program button. You will hear one short beep.
- Test with an existing User Code, the lock should not work.
Troubleshooting
Keypad is not responding.
Check battery.
Desired user code cannot be programmed.
For security reasons, the first 4 digits of each user code must be unique. For
example, you are unable to program a user code 4-8-1-5-1 as well as a user
code 4-8-1-5-2.
Key cannot be removed when unlocked.
This is a feature to ensure the door is always locked and the key is removed
(store room function). To remove the key, return the key to vertical position
to remove.
Emergency egress function
This lock has an emergency egress function which allows you to exit by turning
the lever on the inside, regardless of whether it is in Auto-lock or Passage
mode. This lock has an emergency egress function which allows you to exit by
turning the lever on the inside, regardless of whether it is in Auto-lock or
Passage mode.
Regulatory Compliance
This product complies with standards established by the following regulatory bodies:
- Federal Communications Commission (FCC)
- Industry Canada
Fcc
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which thereceiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
IMPORTANT! Changes or modifications not expressly approved by the
manufacturer could void the user’s authority to operate the equipment.
Industry Canada
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
Important Safeguards
- Read all instructions in their entirety.
- Familiarize yourself with all warning and caution statements.
- Remind all users of safety precautions.
- Protect your user codes and programming code.
- Dispose of used batteries according to local laws and regulations.
CAUTION: Prevent unauthorized entry. Since anyone with access to the back
panel can change the user codes, you must restrict access to the back panel
and routinely check the user codes to ensure they have not been altered
without your knowledge. The use of a program code can help protect your
system’s settings.
WARNING: This Manufacturer advises that no lock can provide complete
security by itself. This lock may be defeated by forcible or technical means,
or evaded by entry elsewhere on the property. No lock can substitute for
caution, awareness of your environment, and common sense. Builder’s hardware
is available in multiple performance grades to suit the application. In order
to enhance security and reduce risk, you should consult a qualified locksmith
or other security professional.
© 2019 Spectrum Brands, Inc.