SmartCoode 10 Commercial Grade Lever GED2600 Instruction Manual
- June 8, 2024
- Weiser
Table of Contents
- 1 Prepare the door and check dimensions
- 2 Install the latch and strike
- 1 Install the exterior keypad, spindle, and interior assembly
- 4 Install levers
- 5 Test latch Operation
- 6 Prepare
- 7 Add user codes
- 8 OPTIONAL: Enable/Disable Programming Code
- 9 Test the lock and review lock functionality
- Reference Guide
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
68533, Rev 01
Installation and User Guide
Weiser
1-800-501-9471
www.weiserlock.com
1
Prepare the door and check dimensions
If drilling a new door, use the supplied template and the complete door drilling instructions available at www.weiserlock.com/doorprep.
**A**
Measure to confirm that the hole in the door is 2-1/8″ (54mm).
*If you are installing this lever below an existing lock or you plan to install a lock above this lever, make sure that the distance between holes is at least 6-1/2″ (165 mm).
**B**
Measure to confirm that the backset is either 2-3/8″ or 2-3/4″ (60
or 70 mm).
**C**
Measure to confirm that the hole in the door edge is 1″ (25 mm).
**D**
Measure to confirm that the door is between 1-3/8″ and 1-3/4″ (35 mm
and 44 mm) thick.
2
Install the latch and strike
**A**
Hold the latch in front of the door hole, with the latch face flush
against the door edge.
**B**
Are the latch holes centered in the door hole?
**C**
Is the door edge chiseled?
**D**
Install strike on the door frame.
1
Install the exterior keypad, spindle, and interior assembly
**A**
Install exterior keypad.
**B**
Install spindle.
**C**
OPTIONAL : Install exterior keypad.
**D**
Connect and secure the cable to interior assembly.
**E**
Install interior assembly and secure with mounting screws.
4
Install levers
**A**
Install exterior lever.
**B**
Insert key and turn 90′ clockwise.
**C**
Secure exterior lever.
**D**
Install interior lever.
**E**
Secure interior lever.
5
Test latch Operation
Close door, these latch operation and make adjustments as needed:
The small bolt of the latch should not enter the strike hole. If it enters the strike hole, reposition the strike.
If the latch is loose in the strike, adjust the strike tab so it grips the latch bolt better when the door is closed.
6
Prepare
**A**
Remove the interior cover.
**B**
Connect 9V battery.
**C**
Secure battery into the interior assembly.
**D**
Reinstall the battery cover.
7
Add user codes
Move swiftly during programming. if no digit is pressed for 10 seconds, the system will time out and you will need to restart the procedure.
**A**
Make sure the door is open.
Press and release the Program button using the Smartkey tool or a paper clip. You will hear two beeps.
**B**
Press 1. You will hear one short beep and the keypad will flash
green once.
**C**
Press Weiser.
**D**
Enter a User Code. It must be between 4 and 8 digits.
For security reasons, the first 4 digits of each user code must be unique. For example, you are unable to program a user code 1-2-3-4-5 as well as a user code 1-2-3-4-6.
**E**
Press Weiser.
**F**
You will hear one long beep and the keypad will flash green if
successful. if you hear three beeps and the keypad flashes red, it was
unsuccessful. Repeat from step A.
8
OPTIONAL: Enable/Disable Programming Code
Please note that once a Programming Code is enabled, the Program button is disabled.
**A**
A Programming Code enables you to make changes without needing to
access the Program button. This is Ideal for landlords to allow programming
from the outside, without access to the interior Program button.
Please note that once a Programming Code is enabled, the Program button Is disabled and can be used only to factory reset the lock.
**B**
Make sure the door is open. Press and release the Program button
suing the Smartkey tool or a paper clip. You will hear two beeps.
**C**
Press 3. You will hear one short beep and the keypad will flash
green.
**D**
Press Weiser.
**E**
Enter a Programming Code. It must be between 4 and 8 digits.
The Programming Code can not be the same as any user code.
**F**
Press Weiser.
**G**
Re-enter Programming Code.
**H**
Press Weiser. You will hear one long beep and the keypad will
flash green if successful. if you hear three beeps and the keypad flashes red,
it was unsuccessful. Repeat from step A.
9
Test the lock and review lock functionality
Unlocking the Door with a User Code
Unlocking the Door with a key
Turnpiece Functions – Choosing a Mode
Emergency Egress
The interior lever of this lock will always open the door when turned, regardless of whether it is locked or unlocked. This is to allow for a safe and easy exit in case of emergency.
Re-key the lock (if needed)
Reference Guide
Additional Programming Features
How to add permanent or one-time User Codes
-
1. 1. Make sure the door is open.
-
If you have not enabled a Programming Code. press and release the Program button. You will hear two beeps.
If you have enabled a Programming Code, enter your Programming Code, then press Welter. You will hear one short beep and the keypad will flash green. -
Press 1 to add a permanent user code that can be used for entry at all times, until deleted.
-
Press 7 to add a onetime user code. A onetime user code may be used only once. which will be deleted immediately after use (typically used in emergency cases when you need to give one-time access to a person).
You will hear one short beep and the keypad will flash green
4. Press Weiser.
5. Enter a new User Code. It must be between 4 and 8 digits. For security reasons, the first 4 digits of each user code must be unique. For example, you are unable to program a user code 4-8-1.5-1 as well as a user code 4+1-5-2.
6. Press WeiSCE.You will hear one tong beep and the keypad will flash green it successful. If you hear three beeps and the keypad flashes red. it was unsuccessful. Repeat from step 1.
How to enable/disable User Codes
User Codes are disabled (example: when you go on vacation). the lock can only
be operated by the key.
-
1. 1. Make sure the door is open.
-
If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps.
If you have enabled a Programming Code, enter your Programming Code, then press Weiser. You will hear one short beep and the keypad will flash green. -
Press 6. You will hear one short beep and the keypad will flash green.
-
Press Weiser. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step 1.
-
How to mute/unmute lock
If the lock is muted, you will not hear beeping during programming, normal operation, or system signals. You will still get a low battery alarm.
-
1. 1. Make sure the door is open.
-
If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps.
If you have enabled a Programming Code, enter your Programming Code, then press WOW. You will hear one short beep and the keypad will flash green. -
Press 5. You will hear one short beep and the keypad will flash green.
-
Press Weiser. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step 1.
-
How to delete individual User Codes
-
1. 1. Make sure the door Is open.
-
If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps.
If you have enabled a Programming Code, enter your Programming Code, then press WelSell You will hear one short beep and the keypad will flash green. -
Press 2 to delete a user code. You will hear one short beep and the keypad will flash green.
-
Press Weiser.
-
Enter the User Code you wish to delete. Press Weiser.
-
Enter the User Code Again.
-
Press Waft’. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red. It was unsuccessful. Repeat from step 1.
-
How to delete all User Codes
-
1. 1. Make sure the door is open.
-
If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps.
If you have enabled a Programming Code, enter your Programming Code. then press WelSer. You will hear one short beep and the keypad will flash green. -
Press 4 You will hear one short beep and the keypad will flash green.
-
Press Weiser.
-
Enter 9-9-9-9-9-9.
-
Press Weiser.
-
Enter 9-9-9-9-9-9
-
Press Weiler. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step 1.
-
How to change the auto-locking duration
-
1. 1. Make sure the door Is open.
If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps.
If you have enabled a Programming Code, enter your Programming Code. then press We see You will hear one short beep and the keypad will flash green.- Press a You will hear one short beep and the keypad will flash green.
- Press Weiser.
- Enter delay time between 1.99 seconds.
- Press Weller. You will hear one long beep and the keypad will flash green If successful. If you hear three beeps and the keypad flashes red. It was unsuccessful. Repeat from step 1.
How to enable/disable turnplece functionality
A feature for property managers
If the turnplece is disabled, the lock will always auto-lock after each entry.
The turnplece will rotate but will not activate passage mode. User code or the
key will always be required for entry.
-
1. 1. Make sure the door is open.
-
If you have not enabled a Programming Code, press and release the Program button. You will hear two beeps.
If you have enabled a Programming Code, enter your Programming Code, then press Weiser You will hear one short beep and the keypad will flash green. -
Press 9. You will hear one long beep and the keypad will flash green.
-
Press Weiler. You will hear one long beep and the keypad will flash green if successful. If you hear three beeps and the keypad flashes red, it was unsuccessful. Repeat from step 1.
-
Factory Reset
A factory reset will delete all codes associated with the lock.
-
1. 1. Make sure the door Is open and unlocked.
- Press and hold the Program button for 30 seconds using the Smartfler tool or a paper clip. You will hear one long beef).
- Press and release the Program button. You will hear one short beep.
- Test with an existing User Code, the lock should not work.
Troubleshooting
Keypad Is not responding.
Check battery.
Desired user code cannot be programmed.
For security reasons, the first 4 digits of each user code must be unique. For
example, you are unable to program a user code 4-8-1-5-1 as well as a user
code 4-8-1.5-2.
Key cannot be removed when unlocked.
This is a feature to ensure the door Is always locked and the key Is removed
(storeroom function). To remove the key. return the key to a vertical position
to remove.
Emergency egress function
This lock has an emergency egress function which allows you to exit by turning
the lever on the Inside. regardless of whether it Is In Auto-lock or Passage
mode.
Regulatory Compliance
This product complies with standards established by the following regulatory bodies: • Federal Communications Commission (FCC) • Industry Canada
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: ( 1 ) this device may not cause harmful
interference, and ( 2 ) this device must accept any interference received,
including interference that may cause undesired operation. This equipment has
been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the Instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
IMPORTANT! Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
Industry Canada
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1 )this device may not cause interference, and ( 2 )this device must accept any interference, including interference that may cause undesired operation of the device.
Important Safeguards
-
1. 1. Read all instructions in their entirety.
- Familiarize yourself with all warning and caution statements.
- Remind all users of safety precautions.
- Protect your user codes and programming code.
- Dispose of used batteries according to local laws and regulations.
CAUTION: Prevent unauthorized entry. Since anyone with access to the back panel can change the user codes, you must restrict access to the back panel and routinely check the user codes to ensure they have not been altered without your knowledge. The use of a program code can help protect your system’s settings.
WARNING: This Manufacturer advises that no lock can provide complete security
by itself. This lock may be defeated by forcible or technical means, or evaded
by entry elsewhere on the property. No lock can substitute for caution,
awareness of your environment, and common sense. Builder’s hardware is
available in multiple performance grades to suit the application. In order to
enhance security and reduce risk, you should consult a qualified locksmith or
other security professional.
© 2019 Spectrum Brands, Inc.